918 resultados para Minimum lactate and Cooper test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Spoken Dialog Challenge 2010 was an exercise to investigate how different spoken dialog systems perform on the same task. The existing Let's Go Pittsburgh Bus Information System was used as a task and four teams provided systems that were first tested in controlled conditions with speech researchers as users. The three most stable systems were then deployed to real callers. This paper presents the results of the live tests, and compares them with the control test results. Results show considerable variation both between systems and between the control and live tests. Interestingly, relatively high task completion for controlled tests did not always predict relatively high task completion for live tests. Moreover, even though the systems were quite different in their designs, we saw very similar correlations between word error rate and task completion for all the systems. The dialog data collected is available to the research community. © 2011 Association for Computational Linguistics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of the contra-rotating Wells turbine installed in the LIMPET wave power station is compared to the predicted performance from theoretical analysis and model tests. A reasonable agreement was found between the predicted and measured turbine damping characteristic, however the turbine efficiency was found to be poorly predicted. It is postulated that this is due to the unsteady nature and mal-distribution of flow through the LIMPET turbine, which were not considered in the predictions. It is suggested that the reduced performance of the contra-rotating Wells turbine makes biplane or monoplane Wells turbines with guide vanes better solutions for OWC's.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated the effect of statistics anxiety and attitudes on first year psychology students’ predicted and actual statistics class test scores. A total of 52 students completed the Statistics Anxiety Rating Scale and estimated their class test scores one week before their test at the end of first year. Regression models were conducted with the six attitude and anxiety subscales as predictors and the predicted and actual test scores as criterion variables. The results showed that computation self concept and fear of asking for help accounted for 37% of the variance in predicted test scores. However, when actual test scores were analysed the significant predictors were worth of statistics and interpretation anxiety, which accounted for 20% of the variance. These results suggested that while statistics anxiety does influence students’ perceptions of their competence it appears to have less effect on their actual performance. Results also suggested that students were unaware of their own statistical competence. Remedial action is required to address the level of statistics anxiety experienced by first year undergraduate psychology students, as it appears to result in unrealistic assessments of their ability and has detrimental effects on their statistics self-efficacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Lung clearance index (LCI) derived from sulfur hexafluoride (SF6) multiple breath washout (MBW) is a sensitive measure of lung disease in people with cystic fibrosis (CF). However, it can be time-consuming, limiting its use clinically. Aim: To compare the repeatability, sensitivity and test duration of LCI derived from washout to 1/30th (LCI1/30), 1/20th (LCI1/20) and 1/10th (LCI1/10) to ‘standard’ LCI derived from washout to 1/40th initial concentration (LCI1/40). Methods: Triplicate MBW test results from 30 clinically stable people with CF and 30 healthy controls were analysed retrospectively. MBW tests were performed using 0.2% SF6 and a modified Innocor device. All LCI end points were calculated using SimpleWashout software. Repeatability was assessed using coefficient of variation (CV%). The proportion of people with CF with and without abnormal LCI and forced expiratory volume in 1 s (FEV1) % predicted was compared. Receiver operating characteristic (ROC) curve statistics were calculated. Test duration of all LCI end points was compared using paired t tests. Results: In people with CF, LCI1/40 CV% (p=0.16), LCI1/30 CV%, (p=0.53), LCI1/20 CV% (p=0.14) and LCI1/10 CV% (p=0.25) was not significantly different to controls. The sensitivity of LCI1/40, LCI1/30 and LCI1/20 to the presence of CF was equal (67%). The sensitivity of LCI1/10 and FEV1% predicted was lower (53% and 47% respectively). Area under the ROC curve (95% CI) for LCI1/40, LCI1/30, LCI1/20, LCI1/10 and FEV1% predicted was 0.89 (0.80 to 0.97), 0.87 (0.77 to 0.96), 0.87 (0.78 to 0.96), 0.83 (0.72 to 0.94) and 0.73 (0.60 to 0.86), respectively. Test duration of LCI1/30, LCI1/20 and LCI1/10 was significantly shorter compared with the test duration of LCI1/40 in people with CF (p<0.0001) equating to a 5%, 9% and 15% time saving, respectively. Conclusions: In this study, LCI1/20 was a repeatable and sensitive measure with equal diagnostic performance to LCI1/40. LCI1/20 was shorter, potentially offering a more feasible research and clinical measure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a unique environment whose features are able to satisfy requirements for both virtual maintenance and virtual manufacturing through the conception of original virtual reality (VR) architecture. Virtual Reality for the Maintainability and Assemblability Tests (VR_MATE) encompasses VR hardware and software and a simulation manager which allows customisation of the architecture itself as well as interfacing with a wide range of devices employed in the simulations. Two case studies are presented to illustrate VR_MATE's unique ability to allow for both maintainability tests and assembly analysis of an aircraft carriage and a railway coach cooling system respectively. The key impact of this research is the demonstration of the potentialities of using VR techniques in industry and its multiple applications despite the subjective character within the simulation. VR_MATE has been presented as a framework to support the strategic and operative objectives of companies to reduce product development time and costs whilst maintaining product quality for applications which would be too expensive to simulate and evaluate in the real world.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We previously demonstrated in pigs with acute liver failure (ALF) that albumin dialysis using the molecular adsorbents recirculating system (MARS) attenuated a rise in intracranial pressure (ICP). This was independent of changes in arterial ammonia, cerebral blood flow and inflammation, allowing alternative hypotheses to be tested. The aims of the present study were to determine whether changes in cerebral extracellular ammonia, lactate, glutamine, glutamate, and energy metabolites were associated with the beneficial effects of MARS on ICP. Three randomized groups [sham, ALF (induced by portacaval anastomosis and hepatic artery ligation), and ALF+MARS] were studied over a 6-hour period with a 4-hour MARS treatment given beginning 2 hours after devascularization. Using cerebral microdialysis, the ALF-induced increase in extracellular brain ammonia, lactate, and glutamate was significantly attenuated in the ALF+MARS group as well as the increases in extracellular lactate/pyruvate and lactate/glucose ratios. The percent change in extracellular brain ammonia correlated with the percent change in ICP (r(2) = 0.511). Increases in brain lactate dehydrogenase activity and mitochondrial complex activity for complex IV were found in ALF compared with those in the sham, which was unaffected by MARS treatment. Brain oxygen consumption did not differ among the study groups. Conclusion: The observation that brain oxygen consumption and mitochondrial complex enzyme activity changed in parallel in both ALF- and MARS-treated animals indicates that the attenuation of increased extracellular brain ammonia (and extracellular brain glutamate) in the MARS-treated animals reduces energy demand and increases supply, resulting in attenuation of increased extracellular brain lactate. The mechanism of how MARS reduces extracellular brain ammonia requires further investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work aims at deciphering the processes that control the nutrient distribution along the EEZ (Exclusive Economic Zone of India) of the west coast of India and to bring out its linkage with primary and secondary productivity. This work assume utmost importance as very few studies have hitherto focused entirely on the EEZ of the west coast of India to address the biochemical responses brought about by monsoons. The present study examines the seasonal variations in physicochemical parameters and associated primary biological responses along the west coast of India. This study targets to measure and understand the shelf ocean exchange in a typical coastal upwelling region of the southeast Arabian Sea, and the influence of convective mixing along the northern part of the west coast of India. The study focuses more directly on coastal upwelling along the southwest coast of India, within the EEZ. The effects of coastal upwelling, eddy formation and the offshore advection are apparent in the present investigation. This has consequences to fisheries and climate, in energy transfer to the food chain and the increased sequestering of carbon in the ocean. The study also focuses on the Oxygen Minimum Zone (OMZ) and dentrification observed along the EEZ of the west coast of India on a seasonal scale. In the study, an attempt is also made to demarcate the geographical boundaries of the denitrification zone in the EEZ of India and on the nature and magnitude of these variations, on a seasonal and inter annual scales