995 resultados para Microwave frequencies


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Strong magnetoelectric (ME) interaction was exhibited at both dc and microwave frequencies in a lead-free multiferroic particulate composites of Na0.5Bi0.5TiO3 (NBT) and MnFe2O4 (MFO) multiferroic, which were prepared by sol-gel route. The room temperature permeability measurements were carried out in the frequency range of 1 MHz-1 GHz. A systematic study of structural, magnetic and ME properties were undertaken. The room temperature ferromagnetic resonance (FMR) was studied. Strong ME coupling is demonstrated in 70NBT-30MFO composite by an electrostatically tunable FMR field shift up to 428 Oe (at E = 4 kV/cm), which increases to a large value of 640 Oe at E = 8 kV/cm. Furthermore, these lead-free multiferroic composites exhibiting electrostatically induced magnetic resonance field at microwave frequencies provide great opportunities for electric field tunable microwave devices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[Es]Actualmente ninguna área científica es ajena a la revolución de la nanociencia; las nanopartículas atraen el interés de muchos investigadores desde el punto de vista de la ciencia fundamental y para sus aplicaciones tecnológicas. Las nanopartículas ofrecen la posibilidad de fabricar sensores que sean capaces de detectar desde un virus hasta concentraciones de substancias patógenas que no pueden ser detectadas por los métodos convencionales. Hoy en día existes 82 tratamientos contra el cáncer basadas en la utilización de nanopartículas y los materiales composite con nanopartículas se utilizan como medio de protección frente la radiación del rango de microondas. En la rama de ciencias ambientales, las nanopartículas metálicas sirven como materiales anticontaminantes. En este trabajo se ha estudiado la estructura y las propiedades magnéticas de las nanopartículas de FeNi preparadas mediante el método de explosión eléctrica de hilo. Con la técnica de Rayos–X(DRX) se ha determinado que las nanopartículas se cristalizan en un sistema cúbico FCC con un parámetro de celda de 3.596 Å, también, se ha obtenido el tamaño de dominio coherente que es de 35 nm. La muestra se ha sometido a un programa de temperatura controlada para seguir la evolución de la estructura cristalina y del tamaño del cristal, tanto en atmósfera oxidante como en vacío. Para el aprendizaje de los microscopios utilizados en este trabajo, se ha asistido al curso “Fundamentos de microscopia electrónica de barrido y microanálisis” impartido por SGIker de la UPV/EHU. Se han empleado los microscopios electrónicos SEM y TEM para obtener imágenes de gran resolución de la muestra y analizar su contenido elemental. Partiendo de las imágenes sacadas por el SEM se ha calculado el valor medio del tamaño de las partículas de la muestra, 58 nm. Mediante el Mastersizer 2000 se ha medido el tamaño de las partículas y/o agregados por método de difracción láser, disgregando la muestra todo lo posible hasta conseguir el tamaño medio que se aproxime al de una sola partícula, 100nm. Por último, para la caracterización magnética se ha servido del VSM que mide el momento magnético de una muestra cuando ésta vibra en presencia de un campo magnético estático, consiguiendo una imanación de saturación de 125 emu/g. Hemos fabricado y caracterizado las nanopartículas magnéticas de hierro-níquel y los resultados obtenidos han sido enviados a un congreso especializado de ciencia de materiales (ISMANAM - 2013, Italia).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method for investigating the dynamics of atomic magnetic moments in current-carrying magnetic point contacts under bias is presented. This combines the nonequilibrium Green's function (NEGF) method for evaluating the current and the charge density with a description of the dynamics of the magnetization in terms of quasistatic thermally activated transitions between stationary configurations. This method is then implemented in a tight-binding (TB) model with parameters chosen to simulate the main features of the electronic structures of magnetic transition metals. We investigate the domain wall (DW) migration in magnetic monoatomic chains sandwiched between magnetic leads, and for realistic parameters find that collinear arrangement of the magnetic moments of the chain is always favorable. Several stationary magnetic configurations are identified, corresponding to a different number of Bloch walls in the chain and to a different current. The relative stability of these configurations depends on the geometrical details of the junction and on the bias; however, we predict transitions between different configurations with activation barriers of the order of a few tens of meV. Since different magnetic configurations are associated with different resistances, this suggests an intrinsic random telegraph noise at microwave frequencies in the I-V curves of magnetic atomic point contacts at room temperature. Finally, we investigate whether or not current-induced torques are conservative.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An analysis of a modified series-L/parallel-tuned Class-E power amplifier is presented, which includes the effects that a shunt capacitance placed across the switching device will have on Class-E behaviour. In the original series L/parallel-tuned topology in which the output transistor capacitance is not inherently included in the circuit, zero-current switching (ZCS) and zero-current derivative switching (ZCDS) conditions should be applied to obtain optimum Class-E operation. On the other hand, when the output transistor capacitance is incorporated in the circuit, i.e. in the modified series-L/parallel-tuned topology, the ZCS and ZCDS would not give optimum operation and therefore zero-voltage-switching (ZVS) and zero-voltage-derivative switching (ZVDS) conditions should be applied instead. In the modified series-L/parallel-tuned Class-E configuration, the output-device inductance and the output-device output capacitance, both of which can significantly affect the amplifier's performance at microwave frequencies, furnish part, if not all, of the series inductance L and the shunt capacitance COUT, respectively. Further, when compared with the classic shunt-C/series-tuned topology, the proposed Class-E configuration offers some advantages in terms of 44% higher maximum operating frequency (fMAX) and 4% higher power-output capability (PMAX). As in the classic topology, the fMAX of the proposed amplifier circuit is reached when the output-device output capacitance furnishes all of the capacitance COUT, for a given combination of frequency, output power and DC supply voltage. It is also shown that numerical simulations agree well with theoretical predictions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bodyworn antennas are found in a wide range of medical, military and personal communication applications, yet reliable communication from the surface of the human body still presents a range of engineering challenges. At UHF and microwave frequencies, bodyworn antennas can suffer from reduced efficiency due to electromagnetic absorption in tissue, radiation pattern fragmentation and variations in feed-point impedance. The significance and nature of these effects are system specific and depend on the operating frequency, propagation environment and physical constraints on the antenna itself. This paper describes how numerical electromagnetic modelling techniques such as FDTD (finite-difference time-domain) can be used in the design of bodyworn antennas. Examples are presented for 418 MHz, 916 .5 MHz and 2 . 45 GHz, in the context of both biomedical signalling and wireless personal-area networking applications such as the Bluetooth(TM)* wireless technology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Poly(o-toluidine) (PoT) and poly(o-toluidine co aniline) were prepared by using ammonium persulfate initiator, in the presence of 1M HCI. It was dried under different conditions: room temperature drying (48 h), oven drying (at 50°C for 12 h), or vacuum drying (under vacuum, at room temperature for 16 h). The dielectric properties, such as dielectric loss, conductivity, dielectric constant, dielectric heating coefficient, loss tangent, etc., were studied at microwave frequencies. A cavity perturbation technique was used for the study. The dielectric properties were found to be related to the frequency and drying conditions. Also, the copolymer showed better properties compared to PoT alone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Polypyrrole/poly (vinyl chloride) semi-interpenenzrtirtg networks of different compositions are prepared using anunonitun per sulfate initiator at room temperature in pellet.form and lilrrt form and their dielectric properties are studied at different microwave frequencies. An HP 8510 Vector network analyzer interfaced with a computer is used. The cavity-perturbation technique is employed for the study

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This 'study' deals with a preliminary study of automatic beam steering properly in conducting polyaniline . Polyaniline in its undoped and doped .state was prepared from aniline by the chemical oxidative polymerization method. Dielectric properties of the samples were studied at S-band microwave frequencies using cavity perturbation technique. It is found that undoped po/vanihne is having greater dielectric loss and conductivity contpared with the doped samples. The beam steering property is studied using a perspex rod antenna and HP 85/OC vector network analyzer. The shift in the radiated beam is studied for different do voltages. The results show that polyaniline is a good nutterial far beam steering applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article reports a new in vitro bile analysis based on the measurement of the dielectric properties at microwave frequencies. The measurements were made using rectangular cavity perturbation technique at the S-band of microwave frequency with the different samples of bile obtained from healthy persons as well as from patients. It is observed that an appreciable change in the dielectric properties of patient’s samples with the normal healthy samples and these measurements were in good agreement with clinical analysis. These results prove an alternative in-vitro method of detecting bile abnormalities based on the measurement of the dielectric properties of bile samples using microwaves without surgical procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

HIV/AIDS is one of the most destructive epidemics in ever recorded history claims an estimated 2.4 –3.3 million lives every year. Even though there is no treatment for this pandemic Elisa and Western Blot tests are the only tests currently available for detecting HIV/AIDS. This article proposes a new method of detecting HIV/AIDS based on the measurement of the dielectric properties of blood at the microwave frequencies. The measurements were made at the S-band of microwave frequency using rectangular cavity perturbation technique with the samples of blood from healthy donors as well as from HIV/AIDS patients. An appreciable change is observed in the dielectric properties of patient samples than with the normal healthy samples and these measurements were in good agreement with clinical results. This measurement is an alternative in vitro method of diagnosing HIV/AIDS using microwaves.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Novel thermo-reversible zinc sulphonated ionomers based on styrene butadiene rubber (SBR), and high styrene rubber (HSH) were synthesized by sulphonation followed by neutralization with zinc. The sulphonate content of the ionomer was estimated by using x-ray fluorescence spectroscopy. Presence of sulphonate groups has been confirmed by FTIR and FTNMR spectra. The TGA results show improvement in the thermo~oxidative stability of the modified rubber. Both DSC and DMTA studies show that the incorporation of the ionic groups affect the glass rubber transition of the base polymer. lntroduction ol ionic functionality in to the base material improved the physical properties. Retention of the improved physical properties of the novel ionomers even after three repeated cycles of mixing and molding may be considered as the evidence for the reprocessability of the ionomer. Effect of particulate fillers (HAF black, silica and zinc stearate) on the properties of the zinc sulphonated styrene butadiene rubber ionomer has been evaluated. Incorporation of tillers results in improvement in mechanical properties. Zinc stearate plays the dual role of reinforcement and plasticization. The evaluation of dielectric properties of zinc sulphonated styrene butadiene rubber iorpmers at microwave frequencies reveal that the materials show conductivity at semiconductor level. The real and imaginary parts of the complex permittivity increases with increase in ionic functionality. Use of the 38.5 ZnS-SBR ionomer as a compatibiliser for obtaining the technologically compatible blends from the immiscible SBR/NBR system has been discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A dual band RFID applications in 800 900 MHz and 2400 MHz band is presented. The Asymmetric Coplanar Strip (ACS) fed antenna consists of inverted L shaped monopole with a capacitive loading to provide necessary impedance matching and current distribution. The antenna has wide bandwidth from 790 MHz tol050 MHz and from 2350 MHz to 2640 MHz coving the RFID UHF and Microwave frequencies. The uniplanar antenna having overall dimensions of 48 mm x 14 mm is printed on one side of a substrate of dielectric constant 4.4 and height 1.6 mm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nickel–rubber nanocomposites were synthesized by incorporating ferromagnetic nickel nanoparticles in a natural rubber as well as neoprene rubber matrix. Complex dielectric permittivity and magnetic permeability of these composites were evaluated in the X-band microwave frequencies at room temperature using cavity perturbation technique. The dielectric loss in natural rubber is smaller compared to neoprene rubber. A steady increase in the dielectric permittivity is observed with increase in the content of nickel in both the composites. The magnetic permeability exhibits a steady decrease with increase in frequency and magnetic loss shows a relaxation at 8 GHz. The suitability of these composites as microwave absorbers is modeled based on the reflection loss which is dependant on the real and imaginary components of the complex dielectric permittivity and magnetic permeability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In 2007, the Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF) was operated for a nine-month period in the Murg Valley, Black Forest, Germany, in support of the Convective and Orographically-induced Precipitation Study (COPS). The synergy of AMF and COPS partner instrumentation was exploited to derive a set of high-quality thermodynamic and cloud property profiles with 30 s resolution. In total, clouds were present 72% of the time, with multi-layer mixed phase (28.4%) and single-layer water clouds (11.3%) occurring most frequently. A comparison with the Cloudnet sites Chilbolton and Lindenberg for the same time period revealed that the Murg Valley exhibits lower liquid water paths (LWPs; median = 37.5 g m−2) compared to the two sites located in flat terrain. In order to evaluate the derived thermodynamic and cloud property profiles, a radiative closure study was performed with independent surface radiation measurements. In clear sky, average differences between calculated and observed surface fluxes are less than 2% and 4% for the short wave and long wave part, respectively. In cloudy situations, differences between simulated and observed fluxes, particularly in the short wave part, are much larger, but most of these can be related to broken cloud situations. The daytime cloud radiative effect (CRE), i.e. the difference of cloudy and clear-sky net fluxes, has been analysed for the whole nine-month period. For overcast, single-layer water clouds, sensitivity studies revealed that the CRE uncertainty is likewise determined by uncertainties in liquid water content and effective radius. For low LWP clouds, CRE uncertainty is dominated by LWP uncertainty; therefore refined retrievals, such as using infrared and/or higher microwave frequencies, are needed.