974 resultados para Microscopy of materials


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine the subbasal nerve density and tortuosity at 5 corneal locations and to investigate whether these microstructural observations correlate with corneal sensitivity. Method: Sixty eyes of 60 normal human subjects were recruited into 1 of 3 age groups, group 1: aged ,35 years, group 2: aged 35–50 years, and group 3: aged .50 years. All eyes were examined using slit-lamp biomicroscopy, noncontact corneal esthesiometry, and slit scanning in vivo confocal microscopy. Results: The mean subbasal nerve density and the mean corneal sensitivity were greatest centrally (14,731 6 6056 mm/mm2 and 0.38 6 0.21 millibars, respectively) and lowest in the nasal mid periphery (7850 6 4947 mm/mm2 and 0.49 6 0.25 millibars, respectively). The mean subbasal nerve tortuosity coefficient was greatest in the temporal mid periphery (27.3 6 6.4) and lowest in the superior mid periphery (19.3 6 14.1). There was no significant difference in mean total subbasal nerve density between age groups. However, corneal sensation (P = 0.001) and subbasal nerve tortuosity (P = 0.004) demonstrated significant differences between age groups. Subbasal nerve density only showed significant correlations with corneal sensitivity threshold in the temporal cornea and with subbasal nerve tortuosity in the inferior and nasal cornea. However, these correlations were weak. Conclusions: This study quantitatively analyzes living human corneal nerve structure and an aspect of nerve function. There is no strong correlation between subbasal nerve density and corneal sensation. This study provides useful baseline data for the normal living human cornea at central and mid-peripheral locations

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose The aim of this work is to develop a more complete understanding of the in vivo histology of the human palpebral conjunctiva and tarsal plate. Methods. The upper eyelids of 11 healthy human volunteer subjects were everted, and laser scanning confocal microscopy was used to examine the various tissue layers of the palpebral conjunctiva and tarsal plate. Results The superficial and basal epithelial layers are composed of cells with gray cytoplasm and thick, light gray borders.Nuclei can not be seen. The stroma has a varied appearance; fibrous tissue is sometimes observed, interspersed with dark,amorphous lacunae, and crevases. Numerous single white or gray cells populate this tissue, and fine blood vessels are seen traversing the field. Occasional conjunctival microcysts and Langerhans cells are observed. The tarsal plate is dark and amorphous, and meibomian gland acini with convoluted borders are clearly observed. Acini are composed of an outer lining of large cuboidal cells, and differentiated secretory cells can be seen within the acini lumen. Conclusions Laser scanning confocal microscopy is capable of studying the human palpebral conjunctiva, tarsal plate, and acini of meibomian glands in vivo. The observations presented here may provide useful supplementary anatomical information relating to the morphology of this tissue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim of this work is to develop a more complete qualitative and quantitative understanding of the in vivo histology of the human bulbar conjunctiva. Methods: Laser scanning confocal microscopy (LSCM) was used to observe and measure morphological characteristics of the bulbar conjunctiva of 11 healthy human volunteer subjects. Results: The superficial epithelial layer of the bulbar conjunctiva is seen as a mass of small cell nuclei. Cell borders are sometimes visible. The light grey borders of basal epithelial cells are clearly visible, but nuclei can not be seen. The conjunctival stroma is comprised of a dense meshwork of white fibres, through which traverse blood vessels containing cellular elements. Orifices at the epithelial surface may represent goblet cells that have opened and expelled their contents. Goblet cells are also observed in the deeper epithelial layers, as well as conjunctival microcysts and mature forms of Langerhans cells. The bulbar conjunctiva has a mean thickness of 32.9 1.1 mm, and a superficial and basal epithelial cell density of 2212 782 and 2368 741 cells/ mm2, respectively. Overall goblet and mature Langerhans cell densities are 111 58 and 23 25 cells/mm2, respectively. Conclusions: LSCM is a powerful technique for studying the human bulbar conjunctiva in vivo and quantifying key aspects of cell morphology. The observations presented here may serve as a useful marker against which changes in conjunctival morphology due to disease, surgery, drug therapy or contact lens wear can be assessed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Raman spectroscopy has been used to study the arsenate minerals haidingerite Ca(AsO3OH)•H2O and brassite Mg(AsO3OH)•4H2O. Intense Raman bands in haidingerite spectrum observed at 745 and 855 cm-1 are assigned to the (AsO3OH)2- ν3 antisymmetric stretching and ν1 symmetric stretching vibrational modes. For brassite two similarly assigned intense bands are found at 809 and 862 cm-1. The observation of multiple Raman bands in the (AsO3OH)2- stretching and bending regions suggests that the arsenate tetrahedrons in the crystal structures of both minerals studied are strongly distorted. Broad Raman bands observed at 2842 cm-1 for haidingerite and 3035 cm-1 for brassite indicate strong hydrogen bonding of water molecules in the structure of these minerals. OH…O hydrogen bond lengths were calculated from the Raman spectra based on empiric relations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

User needs and wants dictate the way in which products are designed, produced, used and disposed of. Western society in particular has become very consumer driven and the waste resulting from such activity has the potential to be disastrous. The creation of emotional attachment with possessions is one way of approaching sustainable consumer-product relationships. The aim of this research was to gain a deeper understanding of the interaction and emotional attachment that consumers have and develop with their products. It outlines literature relating to consumer emotion and experience in relation to products, and how pleasurable product user relationships can be prolonged. It is evident from the literature that the roles of materials in the emotional attachment consumers have with products needed to be further explored. A study was conducted to determine consumers. concepts of six materials currently used in product design. This involved participants being given a Concept Prompt Probe with textual prompts to assist in discussion about the materials in question. The discussions between the 15 participant groups of two people, one male and one female, were then transcribed and coded ready for analysis. The study findings demonstrate consumers. concepts of the six materials. The findings show both physical and emotional consumer concepts of the materials. It is, however, the interaction of these concepts that is the most significant finding of this research. Each material concept is not only judged emotionally by consumers in its own right but in relation to other concepts as well. The interaction of the consumers. concepts of materials can considerably effect the emotional judgement made about the material and the appropriateness of its application. This research makes a significant contribution to knowledge regarding the effect materials have on the consumers by identifying how materials can prompt emotional judgements and thereby alter the product user experience.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the capabilities of laser scanning confocal microscopy (LSCM) for undertaking qualitative and quantitative investigations of the response of the bulbar conjunctiva to contact lens wear. Methods: LSCM was used to observe and measure morphological characteristics of the bulbar conjunctiva of 11 asymptomatic soft contact lens wearers and 11 healthy volunteer subjects (controls). Results: The appearance of the bulbar conjunctiva is consistent with known histology of this tissue based on light and electron microscopy. The thickness of the bulbar conjunctival epithelium of lens wearers (30.9 ± 1.1 μm) was less than that of controls (32.9 ± 1.1 μm) (P < 0.0001). Superficial and basal bulbar conjunctival epithelial cell densities in contact lens wearers were 91% and 79% higher, respectively, than that in controls (P < 0.0001). No difference was observed in goblet and Langerhans cell density between lens wearers and controls. Conjunctival microcysts were observed in greater numbers, and were larger in size, in lens wearers compared with controls. Conclusions: The effects of contact lens wear on the human bulbar conjunctiva can be investigated effectively at a cellular level using LSCM. The observations in this study suggest that contact lens wear can induce changes in the bulbar conjunctiva such as epithelial thinning and accelerated formation and enlargement of microcysts, increased epithelial cell density, but has no impact on goblet or Langerhans cell density.