889 resultados para Method Evaluation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Utilising computed tomography scans to allow a virtual analysis of three-dimensional reconstructions of the femur, this project confirms that the traditional 1952 Trotter and Gleser stature estimation equations are inapplicable for a contemporary Queensland population. Therefore, this study introduces modern stature estimation equations for femoral length and fragmentary femoral remains using Bayesian statistics for application in forensic anthropological casework. In addition, it was found that caution needs to be applied when comparing estimated stature to reported stature on the missing persons database due to inaccuracy in Queensland drivers' licences.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Any government deciding to invoke widespread change in its higher education sector through implementation of new policies impacts on every institution and all staff and students, often in both the time taken up and the heightened emotions caused. The central phenomenon that this study addresses is the process and consequences of policy changes in higher education in Australia. The aim of this article is to record the research design through the perspective (evaluation research), theoretical framework (program evaluation) and methods (content analysis, descriptive statistical analysis and bibliometric analysis) applied to the investigation of the 2003 federal government higher education reform package. This approach allows both the intended and unintended consequences arising from the policy implementation of three national initiatives focused on learning and teaching in higher education in Australia to surface. As a result, this program evaluation, also known in some disciplines as policy implementation analysis, will demonstrate the applicability of illuminative evaluation as a methodology and reinforce how program evaluation will assist and advise future government reform and policy implementation, and will serve as a legacy for future evaluative research.Any government deciding to invoke widespread change in its higher education sector through implementation of new policies impacts on every institution and all staff and students, often in both the time taken up and the heightened emotions caused. The central phenomenon that this study addresses is the process and consequences of policy changes in higher education in Australia. The aim of this article is to record the research design through the perspective (evaluation research), theoretical framework (program evaluation) and methods (content analysis, descriptive statistical analysis and bibliometric analysis) applied to the investigation of the 2003 federal government higher education reform package. This approach allows both the intended and unintended consequences arising from the policy implementation of three national initiatives focused on learning and teaching in higher education in Australia to surface. As a result, this program evaluation, also known in some disciplines as policy implementation analysis, will demonstrate the applicability of illuminative evaluation as a methodology and reinforce how program evaluation will assist and advise future government reform and policy implementation, and will serve as a legacy for future evaluative research.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Photographic and image-based dietary records have limited evidence evaluating their performance and use among adults with a chronic disease. This study evaluated the performance of a mobile phone image-based dietary record, the Nutricam Dietary Assessment Method (NuDAM), in adults with type 2 diabetes mellitus (T2DM). Criterion validity was determined by comparing energy intake (EI) with total energy expenditure (TEE) measured by the doubly-labelled water technique. Relative validity was established by comparison to a weighed food record (WFR). Inter-rater reliability was assessed by comparing estimates of intake from three dietitians. Ten adults (6 males, age=61.2±6.9 years, BMI=31.0±4.5 kg/m2) participated. Compared to TEE, mean EI was under-reported using both methods, with a mean ratio of EI:TEE 0.76±0.20 for the NuDAM and 0.76±0.17 for the WFR. There was moderate to high correlations between the NuDAM and WFR for energy (r=0.57), carbohydrate (r=0.63, p<0.05), protein (r=0.78, p<0.01) and alcohol (rs=0.85, p<0.01), with a weaker relationship for fat (r=0.24). Agreement between dietitians for nutrient intake for the 3-day NuDAM (ICC = 0.77-0.99) was marginally lower when compared with the 3-day WFR (ICC=0.82-0.99). All subjects preferred using the NuDAM and were willing to use it again for longer recording periods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple cconversence technique is applied to obtain accurate estimates of critical temperatures and critical it\ponmts of a few two- and threpdiniensional king models. When applied to the virial series for hard spheres and hard discs, this method predicts a divergence of the equation-of-state at the density of closest packing.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A restriction analysis of PCR (PCR-REA) amplified apxIVA gene has been suggested as an alternative method for serotyping of Actinobacillus pleuropneumoniae by Jaglic et al. [Jaglic, Z., Svastova, P., Rychlik, I., Nedbalcova, K., Kucerova, Z., Pavlik, I., Bartos, M., 2004. Differentiation of Actinobacillus pleuropneumoniae by PCR-REA based on sequence variability of the apxIVA gene and by ribotyping. Vet. Microbiol. 103, 63-69]. The current study investigated whether this alternative method could distinguish between the reference strains of serovars 13-15 and the value of the method when applied to 47 field isolates representing serovars 1-3, 5, 7-9, 12 and 15 as well as non-typable isolates. The reference strains of serovars 13 and 14 had the same sized product after the apxIVA PCR, while the product for serovar 15 was of different size compared to all the other serovar reference strains. The CfoI digest profiles of the reference serovars 13 and 14 strains were different from each other and from all other serovars. The HpaII digest profiles of these two serovars were very similar to each other, but both were distinctively different from the other serovar profiles. The CfoI digest profile of serovar 15 strain was very similar to the serovars 3 and 12 strains except for two faint extra bands for serovar 15. The HpaII digest profiles of serovars 12 and 15 reference strains were identical. The PCR-REA method correctly recognized the serovar of 21 of 43 field isolates. It was concluded that the method was a useful additional tool to support, but could not replace, conventional serotyping.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

For any construction activity in expansive soils, determination of swelling pressure/heave is an essential step. Though many attempts have been made to develop laboratory procedures by using the laboratory one-dimensional oedometer to determine swelling pressure of expansive soils, they are reported to yield varying results. The main reason for these variations could be heterogeneous moisture distribution of the sample over its thickness. To overcome this variation the experimental procedure should be such that the soil gets fully saturated. Attempts were made to introduce vertical sand drains in addition to the top and bottom drains. In this study five and nine vertical sand drains were introduced to experimentally find out the variations in the swell and swelling pressure. The variations in the moisture content at middle, top, and bottom of the sample in the oedometer test are also reported. It is found that swell-load method is better as compared to zero-swell method. Further, five number of vertical sand drains are found to be sufficient to obtain uniform moisture content distribution.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Among different methods, the transmission-line or the impedance tube method has been most popular for the experimental evaluation of the acoustical impedance of any termination. The current state of method involves extrapolation of the measured data to the reflecting surface or exact locations of the pressure maxima, both of which are known to be rather tricky. The present paper discusses a method which makes use of the positions of the pressure minima and the values of the standing-wave ratio at these points. Lippert's concept of enveloping curves has been extended. The use of Smith or Beranek charts, with their inherent inaccuracy, has been altogether avoided. The existing formulas for the impedance have been corrected. Incidentally, certain other errors in the current literature have also been brought to light.Subject Classification: 85.20.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The paper deals with an exact analysis of standing waves in an impedance tube with mean flow. A method is offered for the experimental evaluation of the various wave parameters. Navier–Stokes equations have been solved for evaluating the volume velocity taking into account mean flow, viscosity, etc. The engine exhaust system has been characterized as an acoustic source with an acoustic pressure and internal impedance. A method is suggested for the evaluation of these hypothetical parameters using the exhaust pipe as an impedance tube.Subject Classification: [43]85.20; [43]20.40.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The paper deals with a method for the evaluation of exhaust muffers with mean flow. A new set of variables, convective pressure and convective mass velocity, have been defined to replace the acoustic variables. An expression for attenuation (insertion loss) of a muffler has been proposed in terms of convective terminal impedances and a velocity ratio, on the lines of the one existing for acoustic filters. In order to evaluate the velocity ratio in terms of convective variables, transfer matrices for various muffler elements have been derived from the basic relations of energy, mass and momentum. Finally, the velocity ratiocum-transfer matrix method is illustrated for a typical straight-through muffler.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The transmission-line or the impedance-tube method for the measurement of the acoustic impedance of any termination involves a search for various minima and maxima of pressure. For this purpose, arrangement has to be made for the microphone to travel along the length of the impedance tube, and this complicates the design of the tube considerably. The present paper discusses a method which consists in evaluating the tube attenuation factor at any convenient frequency by making use of measured SPL's at two (or more) fixed locations with a rigid termination, calculating the tube attenuation factor and wave number at the required frequency of interest with or without mean flow (as applicable), and finally evaluating the impedance of the given termination by measuring and using SPL's at three (or more) fixed locations. Thus, the required impedance tube is considerably smaller in length, simpler in design, easier to manufacture, cheaper in cost and more convenient to use. The design of the tube is also discussed. Incidentally, it is also possible to evaluate the impedance at any low frequency without having to use a larger impedance tube.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have evaluated techniques of estimating animal density through direct counts using line transects during 1988-92 in the tropical deciduous forests of Mudumalai Sanctuary in southern India for four species of large herbivorous mammals, namely, chital (Axis axis), sambar (Cervus unicolor), Asian elephant (Elephas maximus) and gaur (Bos gauras). Density estimates derived from the Fourier Series and the Half-Normal models consistently had the lowest coefficient of variation. These two models also generated similar mean density estimates. For the Fourier Series estimator, appropriate cut-off widths for analysing line transect data for the four species are suggested. Grouping data into various distance classes did not produce any appreciable differences in estimates of mean density or their variances, although model fit is generally better when data are placed in fewer groups. The sampling effort needed to achieve a desired precision (coefficient of variation) in the density estimate is derived. A sampling effort of 800 km of transects returned a 10% coefficient of variation on estimate for chital; for the other species a higher effort was needed to achieve this level of precision. There was no statistically significant relationship between detectability of a group and the size of the group for any species. Density estimates along roads were generally significantly different from those in the interior af the forest, indicating that road-side counts may not be appropriate for most species.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method has been suggested to accurately determine the DBTT of diffusion aluminide bond coats. Micro-tensile testing of free-standing coating samples has been carried out. The DBTT was determined based on the variation of plastic strain-to-fracture with temperature. The positive features of this method over the previously reported techniques are highlighted. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In each stage of product development, we need to take decisions, by evaluating multiple product alternatives based on multiple criteria. Classical evaluation methods like weighted objectives method assumes certainty about information available during product development. However, designers often must evaluate under uncertainty. Often the likely performance, cost or environmental impacts of a product proposal could be estimated only with certain confidence, which may vary from one proposal to another. In such situations, the classical approaches to evaluation can give misleading results. There is a need for a method that can aid in decision making by supporting quantitative comparison of alternatives to identify the most promising alternative, under uncertain information about the alternatives. A method called confidence weighted objectives method is developed to compare the whole life cycle of product proposals using multiple evaluation criteria under various levels of uncertainty with non crisp values. It estimates the overall worth of proposal and confidence on the estimate, enabling deferment of decision making when decisions cannot be made using current information available.