960 resultados para Medical Monitoring


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Food labelling on food packaging has the potential to have both positive and negative effects on diets. Monitoring different aspects of food labelling would help to identify priority policy options to help people make healthier food choices. A taxonomy of the elements of health-related food labelling is proposed. A systematic review of studies that assessed the nature and extent of health-related food labelling has been conducted to identify approaches to monitoring food labelling. A step-wise approach has been developed for independently assessing the nature and extent of health-related food labelling in different countries and over time. Procedures for sampling the food supply, and collecting and analysing data are proposed, as well as quantifiable measurement indicators and benchmarks for health-related food labelling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper outlines a step-wise framework for monitoring foods and beverages provided or sold in publicly funded institutions. The focus is on foods in schools, but the framework can also be applied to foods provided or sold in other publicly funded institutions. Data collection and evaluation within this monitoring framework will consist of two components. In component I, information on existing food or nutrition policies and/or programmes within settings would be compiled. Currently, nutrition standards and voluntary guidelines associated with such policies/programmes vary widely globally. This paper, which provides a comprehensive review of such standards and guidelines, will facilitate institutional learnings for those jurisdictions that have not yet established them or are undergoing review of existing ones. In component II, the quality of foods provided or sold in public sector settings is evaluated relative to existing national or sub-national nutrition standards or voluntary guidelines. Where there are no (or only poor) standards or guidelines available, the nutritional quality of foods can be evaluated relative to standards of a similar jurisdiction or other appropriate standards. Measurement indicators are proposed (within ‘minimal’, ‘expanded’ and ‘optimal’ approaches) that can be used to monitor progress over time in meeting policy objectives, and facilitate comparisons between countries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The liberalization of international trade and foreign direct investment through multilateral, regional and bilateral agreements has had profound implications for the structure and nature of food systems, and therefore, for the availability, nutritional quality, accessibility, price and promotion of foods in different locations. Public health attention has only relatively recently turned to the links between trade and investment agreements, diets and health, and there is currently no systematic monitoring of this area. This paper reviews the available evidence on the links between trade agreements, food environments and diets from an obesity and non-communicable disease (NCD) perspective. Based on the key issues identified through the review, the paper outlines an approach for monitoring the potential impact of trade agreements on food environments and obesity/NCD risks. The proposed monitoring approach encompasses a set of guiding principles, recommended procedures for data collection and analysis, and quantifiable ‘minimal’, ‘expanded’ and ‘optimal’ measurement indicators to be tailored to national priorities, capacity and resources. Formal risk assessment processes of existing and evolving trade and investment agreements, which focus on their impacts on food environments will help inform the development of healthy trade policy, strengthen domestic nutrition and health policy space and ultimately protect population nutrition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INFORMAS (International Network for Food and Obesity/non-communicable diseases Research, Monitoring and Action Support) aims to monitor and benchmark the healthiness of food environments globally. In order to assess the impact of food environments on population diets, it is necessary to monitor population diet quality between countries and over time. This paper reviews existing data sources suitable for monitoring population diet quality, and assesses their strengths and limitations. A step-wise framework is then proposed for monitoring population diet quality. Food balance sheets (FBaS), household budget and expenditure surveys (HBES) and food intake surveys are all suitable methods for assessing population diet quality. In the proposed ‘minimal’ approach, national trends of food and energy availability can be explored using FBaS. In the ‘expanded’ and ‘optimal’ approaches, the dietary share of ultra-processed products is measured as an indicator of energy-dense, nutrient-poor diets using HBES and food intake surveys, respectively. In addition, it is proposed that pre-defined diet quality indices are used to score diets, and some of those have been designed for application within all three monitoring approaches. However, in order to enhance the value of global efforts to monitor diet quality, data collection methods and diet quality indicators need further development work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design and synthesis of molecularly or supramolecularly defined interfacial architectures have seen in recent years a remarkable growth of interest and scientific research activities for various reasons. On the one hand, it is generally believed that the construction of an interactive interface between the living world of cells, tissue, or whole organisms and the (inorganic or organic) materials world of technical devices such as implants or medical parts requires proper construction and structural (and functional) control of this organism–machine interface. It is still the very beginning of generating a better understanding of what is needed to make an organism tolerate implants, to guarantee bidirectional communication between microelectronic devices and living tissue, or to simply construct interactive biocompatibility of surfaces in general. This exhaustive book lucidly describes the design, synthesis, assembly and characterization, and bio-(medical) applications of interfacial layers on solid substrates with molecularly or supramolecularly controlled architectures. Experts in the field share their contributions that have been developed in recent years.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Occupational standards concerning allowable concentrations of chemical compounds in the ambient air of workplaces have been established in several countries worldwide. With the integration of the European Union (EU), there has been a need of establishing harmonised Occupational Exposure Limits (OEL). The European Commission Directive 95/320/EC of 12 July 1995 has given the tasks to a Scientific Committee for Occupational Exposure Limits (SCOEL) to propose, based on scientific data and where appropriate, occupational limit values which may include the 8-h time-weighted average (TWA), short-term limits/excursion limits (STEL) and Biological Limit Values (BLVs). In 2000, the European Union issued a list of 62 chemical substances with Occupational Exposure Limits. Of these, 25 substances received a "skin" notation, indicating that toxicologically significant amounts may be taken up via the skin. For such substances, monitoring of concentrations in ambient air may not be sufficient, and biological monitoring strategies appear of potential importance in the medical surveillance of exposed workers. Recent progress has been made with respect to formulation of a strategy related to health-based BLVs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The high priority of monitoring workers exposed to nitrobenzene is a consequence of clear findings of experimental carcinogenicity of nitrobenzene and the associated evaluations by the International Agency for Research on Cancer. Eighty male employees of a nitrobenzene reduction plant, with potential skin contact with nitrobenzene and aniline, participated in a current medical surveillance programme. Blood samples were routinely taken and analysed for aniline, 4-aminodiphenyl (4-ADP) and benzidine adducts of haemoglobin (Hb) and human serum albumin (HSA). Also, levels of methaemoglobin (Met-Hb) and of carbon monoxide haemoglobin (CO-Hb) were monitored. Effects of smoking were straightforward. Using the rank sum test of Wilcoxon, we found that very clear-cut and statistically significant smoking effects (about 3-fold increases) were apparent on CO-Hb (P = 0.00085) and on the Hb adduct of 4-ADP (P = 0.0006). The mean aniline-Hb adduct level in smokers was 1.5 times higher than in non-smokers; the significance (P = 0.05375) was close to the 5% level. The strongest correlation was evident between the Hb and HSA adducts of aniline (rs = 0.846). Less pronounced correlations (but with P values < 0.02) appeared between aniline-Hb and 4-ADP-Hb adducts (rs = 0.388), between 4-ADP and 4-ADP-HSA adducts (rs = 0.373), and between 4-ADP-Hb and aniline-HSA adducts (rs = 0.275). In view of the proposal for additional use of the aniline-HSA adduct for biological monitoring, particularly in cases of acute overexposures or poisonings, the strong correlation of the Hb and HSA conjugates is noteworthy; the ratio aniline-HSA:aniline-Hb was 1:42 for the entire cohort.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we present research adapting a state of the art condition-invariant robotic place recognition algorithm to the role of automated inter- and intra-image alignment of sensor observations of environmental and skin change over time. The approach involves inverting the typical criteria placed upon navigation algorithms in robotics; we exploit rather than attempt to fix the limited camera viewpoint invariance of such algorithms, showing that approximate viewpoint repetition is realistic in a wide range of environments and medical applications. We demonstrate the algorithms automatically aligning challenging visual data from a range of real-world applications: ecological monitoring of environmental change, aerial observation of natural disasters including flooding, tsunamis and bushfires and tracking wound recovery and sun damage over time and present a prototype active guidance system for enforcing viewpoint repetition. We hope to provide an interesting case study for how traditional research criteria in robotics can be inverted to provide useful outcomes in applied situations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Procedural sedation and analgesia (PSA) is used to attenuate the pain and distress that may otherwise be experienced during diagnostic and interventional medical or dental procedures. As the risk of adverse events increases with the depth of sedation induced, frequent monitoring of level of consciousness is recommended. Level of consciousness is usually monitored during PSA with clinical observation. Processed electroencephalogram-based depth of anaesthesia (DoA) monitoring devices provide an alternative method to monitor level of consciousness that can be used in addition to clinical observation. However, there is uncertainty as to whether their routine use in PSA would be justified. Rigorous evaluation of the clinical benefits of DoA monitors during PSA, including comprehensive syntheses of the available evidence, is therefore required. One potential clinical benefit of using DoA monitoring during PSA is that the technology could improve patient safety by reducing sedation-related adverse events, such as death or permanent neurological disability. We hypothesise that earlier identification of lapses into deeper than intended levels of sedation using DoA monitoring leads to more effective titration of sedative and analgesic medications, and results in a reduction in the risk of adverse events caused by the consequences of over-sedation, such as hypoxaemia. The primary objective of this review is to determine whether using DoA monitoring during PSA in the hospital setting improves patient safety by reducing the risk of hypoxaemia (defined as an arterial partial pressure of oxygen below 60 mmHg or percentage of haemoglobin that is saturated with oxygen [SpO2] less than 90 %). Other potential clinical benefits of using DoA monitoring devices during sedation will be assessed as secondary outcomes. Methods/design Electronic databases will be systematically searched for randomized controlled trials comparing the use of depth of anaesthesia monitoring devices with clinical observation of level of consciousness during PSA. Language restrictions will not be imposed. Screening, study selection and data extraction will be performed by two independent reviewers. Disagreements will be resolved by discussion. Meta-analyses will be performed if suitable. Discussion This review will synthesise the evidence on an important potential clinical benefit of DoA monitoring during PSA within hospital settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dorsiflexion (DF) of the foot plays an essential role in both controlling balance and human gait. Electromyography and Sonomyography can provide information on several aspects of muscle function. The aim was to describe a new method for real-time monitoring of muscular activity, as measured using EMG, muscular architecture, as measured using SMG, force, as measured using dynamometry, and kinematic parameters, as measured using IS during isometric and isotonic contractions of the foot DF. The present methodology may be clinically relevant because it involves a reproducible procedure which allows the function and structure of the foot DF to be monitored.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The care processes of healthcare providers are typically considered as human-centric, flexible, evolving, complex and multi-disciplinary. Consequently, acquiring an insight in the dynamics of these care processes can be an arduous task. A novel event log based approach for extracting valuable medical and organizational information on past executions of the care processes is presented in this study. Care processes are analyzed with the help of a preferential set of process mining techniques in order to discover recurring patterns, analyze and characterize process variants and identify adverse medical events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To develop a set of Australian recommendations for the monitoring and treatment of ankylosing spondylitis (AS) through systematic literature review combined with the opinion of practicing rheumatologists. Methods: A set of eight questions, four in each domain of monitoring and treatment, were formulated by voting and the Delphi method. The results of a systematic literature review addressing each question were presented to the 23 participants of the Australian 3E meeting. All participants were clinical rheumatologists experienced in the daily management of AS. Results: After three rounds of breakout sessions to discuss the findings of the literature review, a set of recommendations was finalized after discussion and voting. The category of evidence and strength of recommendation were determined for each proposal. The level of agreement among participants was excellent (mean 84%, range 64-100%). Conclusions: The 12 recommendations developed from evidence and expert opinion provide guidance for the daily management of AS patients. For most recommendations, we found a paucity of supportive evidence in the literature highlighting the need for additional clinical studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Female athletes, in response to intensive training, competition stress and a lean, athletic physique, are at increased risk of altered hypothalamic-pituitary ovarian (HPO) axis function associated with menstrual cycle disturbance and reduced secretion of the ovarian hormones estrogen and progesterone. Because there is evidence suggesting possible detrimental effects on skeletal health associated with deficiencies in these hormones, a suitable means to asses ovarian hormone concentrations in at risk athletes is needed. The aim of this study was to evaluate a simple, economical means to monitor the ovarian hormone production in athletes, in the setting of intensive training. METHODS: Subjects comprised 14 adolescent rowers, 12 lightweight rowers, and two groups of 10 matched control subjects. Ovarian function was monitored during the competition season by estimation of urinary excretion of estrone glucuronide (E1G) and pregnanediol glucuronide (PdG), enabling the menstrual cycles to be classified as ovulatory or anovulatory. RESULTS: Results indicated 35% and 75% of schoolgirl and lightweight rowers had anovulatory menstrual cycles, respectively. These findings were highlighted by significantly lower excretion of E1G and PdG during phases of intensive training in both the lightweight and schoolgirl rowers, compared with the control subjects. CONCLUSION: It was concluded that the urinary E1G and PdG assays were an effective means to assess the influence of intense training on ovarian hormone concentrations in at risk athletes. It is recommended that this technique be applied more widely as a means of early detection of athletes with low estrogen and progesterone levels, in an attempt to avoid detrimental influences on skeletal health.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Early detection of (pre-)signs of ulceration on a diabetic foot is valuable for clinical practice. Hyperspectral imaging is a promising technique for detection and classification of such (pre-)signs. However, the number of the spectral bands should be limited to avoid overfitting, which is critical for pixel classification with hyperspectral image data. The goal was to design a detector/classifier based on spectral imaging (SI) with a small number of optical bandpass filters. The performance and stability of the design were also investigated. The selection of the bandpass filters boils down to a feature selection problem. A dataset was built, containing reflectance spectra of 227 skin spots from 64 patients, measured with a spectrometer. Each skin spot was annotated manually by clinicians as "healthy" or a specific (pre-)sign of ulceration. Statistical analysis on the data set showed the number of required filters is between 3 and 7, depending on additional constraints on the filter set. The stability analysis revealed that shot noise was the most critical factor affecting the classification performance. It indicated that this impact could be avoided in future SI systems with a camera sensor whose saturation level is higher than 106, or by postimage processing.