987 resultados para Mean deviation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To quantify the interobserver variability of abdominal aortic aneurysm (AAA) neck length and angulation measurements. MATERIALS AND METHODS: A total of 25 consecutive patients scheduled for endovascular AAA repair underwent follow-up 64-row computed tomographic (CT) angiography in 0.625-mm collimation. AAA neck length and angulation were determined by four blinded, independent readers. AAA neck length was defined as the longitudinal distance between the first transverse CT slice directly distal to the lowermost renal artery and the first transverse CT slice that showed at least a 15% larger outer aortic wall diameter versus the diameter measured directly below the lowermost renal artery. Infrarenal AAA neck angulation was defined as the true angle between the longitudinal axis of the proximal AAA neck and the longitudinal axis of the AAA lumen as analyzed on three-dimensional CT reconstructions. RESULTS: Mean deviation in aortic neck length determination was 32.3% and that in aortic neck angulation was 32.1%. Interobserver variability of aortic neck length and angulation measurements was considerable: in any reader combination, at least one measurement difference was outside the predefined limits of agreement. CONCLUSIONS: Assessment of the longitudinal extension and angulation of the infrarenal aortic neck is associated with substantial observer variability, even if measurement is carried out according to a standardized protocol. Further studies are mandatory to assess dedicated technical approaches to minimize variance in the determination of the longitudinal extension and angulation of the infrarenal aortic neck.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to evaluate the precision of central hip arthroscopy in the assessment and treatment of pincer-type femoroacetabular impingement (FAI) avoiding the posterolateral portal, with its close proximity to the main arterial blood supply of the femoral head, the medial circumflex femoral artery. METHODS: Seven human cadaveric hips underwent arthroscopic trimming of the acetabular labrum and rim along a preoperatively defined 105 degrees arc of resection for treatment of a presumed pincer-type lesion. After the arthroscopic procedure, all specimens were dissected and measured for evaluation of the location, quantity, and quality of the area undergoing resection. RESULTS: The difference between the actual and planned arc of resection was 18.7 degrees +/- 4.7 degrees (range, 2 degrees to 34 degrees). This was mainly because of a lack of accuracy in the presumed posterior starting point (PSP), with a mean deviation of 19 degrees +/- 3.4 degrees (range, 10 degrees to 36 degrees). Correlation analysis showed that variance in the arc of resection was mainly dependent on the PSP (r = 0.739, P = .058). CONCLUSIONS: Central hip arthroscopy is a feasible option in treating anterosuperior pincer-type FAI by use of the anterior and anterolateral portals only. This cadaveric study showed that there is a significant risk of underestimating the actual arc of resection compared with the planned arc of resection for posterosuperior pincer-type lesions because of the modest accuracy in determining the PSP of the resection. CLINICAL RELEVANCE: Accurate preoperative planning and arthroscopic identification of anatomic landmarks at the acetabular side are crucial for the definition of the appropriate starting and ending points in the treatment of pincer-type FAI. Whereas anterosuperior pincer-type lesions can be addressed very precisely with our technique, the actual resection of posterosuperior lesions averaged 19 degrees less than the planned resection, which may have clinical implications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry. Materials and methods: An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guided implant treatment. For the assessment of accuracy meta-regression analysis was performed. Complication rates are descriptively summarized. Results: From 3120 titles after the literature search, eight articles met the inclusion criteria regarding accuracy and 10 regarding the clinical performance. Meta-regression analysis revealed a mean deviation at the entry point of 1.07 mm (95% CI: 0.76-1.22 mm) and at the apex of 1.63 mm (95% CI: 1.26-2 mm). No significant differences between the studies were found regarding method of template production or template support and stabilization. Early surgical complications occurred in 9.1%, early prosthetic complications in 18.8% and late prosthetic complications in 12% of the cases. Implant survival rates of 91-100% after an observation time of 12-60 months are reported in six clinical studies with 537 implants mainly restored immediately after flapless implantation procedures. Conclusion: Computer-guided template-based implant placement showed high implant survival rates ranging from 91% to 100%. However, a considerable number of technique-related perioperative complications were observed. Preclinical and clinical studies indicated a reasonable mean accuracy with relatively high maximum deviations. Future research should be directed to increase the number of clinical studies with longer observation periods and to improve the systems in terms of perioperative handling, accuracy and prosthetic complications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within ±1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study evaluated sources of within- and between-subject variability in standard white-on-white (W-W) perimetry and short-wavelength automated perimetry (SWAP). The Influence of staircase strategy on the fatigue effect in W-W perimetry was investigated for a 4 dB single step, single reversal strategy; a variable step size, single reversal dynamic strategy; and the standard 4-2 dB double reversal strategy. The fatigue effect increased as the duration of the examination Increased and was greatest in the second eye for all strategies. The fatigue effect was lowest for the 4dB strategy, which exhibited the shortest examination time and was greatest for the 4-2 dB strategy, which exhibited the longest examination time. Staircase efficiency was lowest for the 4 dB strategy and highest for the dynamic strategy which thus offers a reduced examination time and low inter-subject variability. The normal between-subject variability of SWAP was determined for the standard 4-2 dB double reversal strategy and the 3 dB single reversal FASTPAC strategy and compared to that of W-W perimetry, The decrease in sensitivity with Increase in age was greatest for SWAP. The between-subject variability of SWAP was greater than W-W perimetry. Correction for the Influence of ocular media absorption reduced the between-subject variability of SWAP, The FASTPAC strategy yielded the lowest between-subject variability In SWAP, but the greatest between-subject variability In WoW perimetry. The greater between-subject variability of SWAP has profound Implications for the delineation of visual field abnormality, The fatigue effect for the Full Threshold strategy in SWAP was evaluated with conventional opaque, and translucent occlusion of the fellow eye. SWAP exhibited a greater fatigue effect than W-W perimetry. Translucent occlusion reduced the between-subject variability of W-W perimetry but Increased the between-subject variability of SWAP. The elevation of sensitivity was greater with translucent occlusion which has implications for the statistical analysis of W-W perimetry and SWAP. The influence of age-related cataract extraction and IOL implantation upon the visual field derived by WoW perimetry and SWAP was determined. Cataract yielded a general reduction In sensitivity which was preferentially greater in SWAP, even after the correction of SWAP for the attenuation of the stimulus by the ocular media. There was no correlation between either backward or forward light scatter and the magnitude of the attenuation of W-W or SWAP sensitivity. The post-operative mean deviation in SWAP was positive and has ramifications for the statistical Interpretation of SWAP. Short-wavelength-sensitive pathway isolation was assessed as a function of stimulus eccentricity using the two-colour Increment threshold method. At least 15 dB of SWS pathway Isolation was achieved for 440 nm, 450 nm and 460 nm stimuli at a background luminance of 100 cdm-2, There was a slight decrease In SWS pathway Isolation for all stimulus wavelengths with increasing eccentricity which was not of clinical significance. Adopting a 450 nm stimulus may reduce between-subject variability In SWAP due to a reduction In ocular media absorption and macular pigment absorption.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background - An evaluation of standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP) for the central 10–2 visual field test procedure in patients with age-related macular degeneration (AMD) is presented in order to determine methods of quantifying the central sensitivity loss in patients at various stages of AMD. Methods - 10–2 SAP and SWAP Humphrey visual fields and stereoscopic fundus photographs were collected in 27 eyes of 27 patients with AMD and 22 eyes of 22 normal subjects. Results - Mean Deviation and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post hoc analysis revealed overlap of functional values among stages. In SWAP, indices of focal loss were more sensitive to detecting differences in AMD from normal. SWAP defects were greater in depth and area than those in SAP. Central sensitivity (within 1°) changed by -3.9 and -4.9 dB per stage in SAP and SWAP, respectively. Based on defect maps, an AMD Severity Index was derived. Conclusions - Global indices of focal loss were more sensitive to detecting early stage AMD from normal. The SWAP sensitivity decline with advancing stage of AMD was greater than in SAP. A new AMD Severity Index quantifies visual field defects on a continuous scale. Although not all patients are suitable for SWAP examinations, it is of value as a tool in research studies of visual loss in AMD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Presentation Purpose:To determine methods of quantifying the sensitivity loss in the central 10o visual field in a cross section of patients at various stages of age-related macular degeneration (AMD). Methods:Standard and short-wavelength automated perimetry (SAP and SWAP) visual fields were collected using program 10-2 of the Humphrey Field Analyzer, in 44 eyes of 27 patients with AMD and 41 eyes of 22 normal subjects. Stereoscopic fundus photographs were graded by two independent observers and the stage of disease determined. Global indices were compared for their ability to delineate the normal visual field from early stages of AMD and to differentiate between stages. Results:Mean Deviation (MD) and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post-hoc analysis revealed overlap of functional values between stages. Global indices of focal loss, PSD and local spatial variability (LSV) were the most sensitive to detecting differences between normal subjects and early stage AMD patients, in SAP and SWAP, respectively. Overall, defects were confined to the central 5°. SWAP defects were consistently greater in depth and area than those in SAP. The most vulnerable region of the 10° field to sensitivity loss with increasing stage of AMD was the central 1°, in which the sensitivity decline was -4.8dB per stage in SAP and -4.9dB per stage in SWAP. Based on the pattern deviation defect maps, a severity index of AMD visual field loss was derived. Threshold variability was considerably increased in late stage AMD eyes. Conclusions:Global indices of focal loss were more sensitive to the detection of early stage AMD from normal. The sensitivity decline with advancing stage of AMD was greater in SWAP compared to SAP, however the trend was not strong across all stages of disease. The less commonly used index LSV represents relatively statistically unmanipulated summary measure of focal loss. A new severity index is described which is sensitive to visual field change in AMD, measures visual field defects on a continuous scale and may serve as a useful measure of functional change in AMD in longitudinal studies. Keywords: visual fields • age-related macular degeneration • perimetry

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Presentation Purpose:To relate structural change to functional change in age-related macular degeneration (AMD) in a cross-sectional population using fundus imaging and the visual field status. Methods:10 degree standard and SWAP visual fields and other standard functional clinical measures were acquired in 44 eyes of 27 patients at various stages of AMD, as well as fundus photographs. Retro-mode SLO images were captured in a subset of 29 eyes of 19 of the patients. Drusen area, measured by automated drusen segmentation software (Smith et al. 2005) was correlated with visual field data. Visual field defect position was compared to the position of the imaged drusen and deposits using custom software. Results:The effect of AMD stage on drusen area within the 6000µm was significant (One-way ANOVA: F = 17.231, p < 0.001), however the trend was not strong across all stages. There were significant linear relationships between visual field parameters and drusen area. The mean deviation (MD) declined by 3.00dB and 3.92dB for each log % drusen area for standard perimetry and SWAP, respectively. The visual field parameters of focal loss displayed the strongest correlations with drusen area. The number of pattern deviation (PD) defects increased by 9.30 and 9.68 defects per log % drusen area for standard perimetry and SWAP, respectively. Weaker correlations were found between drusen area and visual acuity, contrast sensitivity, colour vision and reading speed. 72.6% of standard PD defects and 65.2% of SWAP PD defects coincided with retinal signs of AMD on fundus photography. 67.5% of standard PD defects and 69.7% of SWAP PD defects coincided with deposits on retro-mode images. Conclusions:Perimetry exhibited a stronger relationship with drusen area than other measures of visual function. The structure-function relationship between visual field parameters and drusen area was linear. Overall the indices of focal loss had a stronger correlation with drusen area in SWAP than in standard perimetry. Visual field defects had a high coincidence proportion with retinal manifestations of AMD.Smith R.T. et al. (2005) Arch Ophthalmol 123:200-206.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Presentation Purpose:To examine the correlation of central visual field loss and progression of structural changes in the macular area in age-related macular degeneration (AMD). Methods:Central 10° standard and short-wavelength automated perimetry (SWAP) visual fields were acquired in 39 eyes of 24 patients with AMD using a Humphrey Field Analyzer. Stereoscopic fundus photographs were graded1 by two independent observers and the stage of disease determined2. Custom software mapped perimetric data onto fundus images in order to relate structural changes to functional loss. Results:Mean deviation (MD) in standard perimetry changed from 0.04 dB at stage 1 to -12.39 dB at stage 4 (r2=0.48, p<0.001). The group mean SWAP MD was -5.26 dB at stage 1 and increased to -17.08 dB at stage 4 (r2=0.53, p<0.001). Pattern standard deviation (PSD) also increased with advancing stage in standard perimetry; 1.32 dB to 8.67 dB at stage 1 and 4, respectively (r2=0.54, p<0.001). In SWAP, PSD increased from 2.86 dB to 5.63 dB at stage 1 and stage 4 (r2=0.43, p<0.001). Defect frequency was greater in SWAP than standard perimetry. Early stage defects occurred with the greatest frequency at eccentricities of 3.2° and 5.1° in standard perimetry and at 4.2° in SWAP. Late stage defects were most frequent at 1° eccentricity in standard perimetry and at 1° and 9° in SWAP. MD declined with increasing affected retinal area over the central 3000µm; by 0.20 dB (r2=0.67, p<0.001) and 0.18 dB (r2=0.49, p<0.001) per % increase in defect area for standard perimetry and SWAP respectively. 41% of defects were associated with structural changes on the retina in standard perimetry and 43% in SWAP. Conclusions:Sensitivity decreased with advancing stage of AMD, with a greater effect demonstrated in SWAP compared to standard perimetry. The central field became less uniform as stage increased. SWAP defects occurred at similar locations but were deeper and wider than corresponding defects in standard perimetry. Central loss in SWAP is a sensitive marker of functional progression in AMD.1. Bird et al. (1995) Surv Ophthalmol 39:367-3742. van Leeuwen et al. (2003) Arch Ophthalmol 121:519-526

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The tear film, cornea and lens dictate the refractive power of the eye and the retinal image quality is principally defined by diffraction, whole eye wavefront error, scatter, and chromatic aberration. Diffraction and wave aberration are fundamentally pupil diameter dependent; however scatter can be induced by refractive surgery and in the normal ageing eye becomes an increasingly important factor defining retinal image quality. The component of visual quality most affected by the tear film, refractive surgery and multifocal contact and intraocular lenses is the wave aberration of the eye. This body of work demonstrates the effects of each of these anomalies on the visual quality of the eye. When assessing normal or borderline self-diagnosed dry eye subjects using aberrometry, combining lubricating eye drops and spray does not offer any benefit over individual products. However, subjects perceive a difference in comfort for all interventions after one hour. Total higher order aberrations increase after laser assisted sub-epithelial keratectomy performed using a solid-state laser on myopes, but this causes no significant decrease in contrast sensitivity or increase in glare disability. Mean sensitivity and reliability indices for perimetry were comparable to pre-surgery results. Multifocal contact lenses and intraocular lenses are designed to maximise vision when the patient is binocular, so any evaluation of the eyes individually is confounded by reduced individual visual acuity and visual quality. Different designs of aspheric multifocal contact lenses do not provide the same level of visual quality. Multifocal contact lenses adversely affect mean deviation values for perimetry and this should be considered when screening individuals with multifocal contact or intraocular lenses. Photographic image quality obtained through a multifocal contact or intraocular lens appears to be unchanged. Future work should evaluate the effect of these anomalies in combination; with the aim of providing the best visual quality possible and supplying normative data for screening purposes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To determine whether curve-fitting analysis of the ranked segment distributions of topographic optic nerve head (ONH) parameters, derived using the Heidelberg Retina Tomograph (HRT), provide a more effective statistical descriptor to differentiate the normal from the glaucomatous ONH. Methods: The sample comprised of 22 normal control subjects (mean age 66.9 years; S.D. 7.8) and 22 glaucoma patients (mean age 72.1 years; S.D. 6.9) confirmed by reproducible visual field defects on the Humphrey Field Analyser. Three 10°-images of the ONH were obtained using the HRT. The mean topography image was determined and the HRT software was used to calculate the rim volume, rim area to disc area ratio, normalised rim area to disc area ratio and retinal nerve fibre cross-sectional area for each patient at 10°-sectoral intervals. The values were ranked in descending order, and each ranked-segment curve of ordered values was fitted using the least squares method. Results: There was no difference in disc area between the groups. The group mean cup-disc area ratio was significantly lower in the normal group (0.204 ± 0.16) compared with the glaucoma group (0.533 ± 0.083) (p < 0.001). The visual field indices, mean deviation and corrected pattern S.D., were significantly greater (p < 0.001) in the glaucoma group (-9.09 dB ± 3.3 and 7.91 ± 3.4, respectively) compared with the normal group (-0.15 dB ± 0.9 and 0.95 dB ± 0.8, respectively). Univariate linear regression provided the best overall fit to the ranked segment data. The equation parameters of the regression line manually applied to the normalised rim area-disc area and the rim area-disc area ratio data, correctly classified 100% of normal subjects and glaucoma patients. In this study sample, the regression analysis of ranked segment parameters method was more effective than conventional ranked segment analysis, in which glaucoma patients were misclassified in approximately 50% of cases. Further investigation in larger samples will enable the calculation of confidence intervals for normality. These reference standards will then need to be investigated for an independent sample to fully validate the technique. Conclusions: Using a curve-fitting approach to fit ranked segment curves retains information relating to the topographic nature of neural loss. Such methodology appears to overcome some of the deficiencies of conventional ranked segment analysis, and subject to validation in larger scale studies, may potentially be of clinical utility for detecting and monitoring glaucomatous damage. © 2007 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To investigate whether regional long-term changes in peripapillary retinal flow, measured by scanning laser Doppler flowmetry (SLDF), occur in patients with primary open angle glaucoma (POAG). Methods: 31 healthy volunteers (mean age: 65 8.3 years) and 33 POAG patients (mean age: 71.2 7.6 years) were followed up every 4 months for 16 months. Using SLDF, three images of the superior and inferior optic nerve head were obtained for each subject. A 1010-pixel frame was used to measure blood flow, volume and velocity in the four quadrants of the peripapillary retina. Central 24-2 visual field testing was carried out at each visit. Repeated measures analysis of covariance was used to assess change over time between the normal and POAG groups for the SLDF parameters. Univariate linear regression analysis for mean deviation and glaucoma change probability (GCP) analysis were used to identify visual field progression. Results: Blood volume, flow and velocity measured in the inferior nasal quadrant of the peripapillary retina decreased significantly over time for the POAG group compared to the normal group (p=0.0073, 0.0097, 0.0095 respectively). Overall, 2 glaucoma patients showed a significantly deteriorating MD slope, while 7 patients showed visual field progression with GPA. All of the patients progressing with GPA, showed change in the superior hemifield and, of those, 14% showed change in the inferior hemifield. Conclusion: Glaucoma patients showed a decrease in blood flow, volume and velocity in the inferior nasal peripapillary retina. A regional variation in microvascular retinal capillary blood flow may provide insight into the pathogenesis of glaucomatous optic neuropathy. Keywords: 331 blood supply • 554 retina • 624 visual fields

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: Previous investigations have demonstrated a relative vascular autoregulatory inefficiency of the inferior compared to the superior retina in healthy subjects breathing increased CO2. The purpose of this study was to determine whether the superior and inferior visual field sensitivities of healthy eyes are similarly affected during mild hypercapnia. DESIGN: Experimental study. METHODS: Visual field analysis (Humphrey Field Analyser; SITA standard 24-2 program) was carried out on one randomly selected eye of 22 subjects (mean age, 27.7 ± 5 years) during normal room air breathing and isoxic hypercapnia. The Student paired t-tests were used to compare the visual field indices mean deviation (MD) and pattern standard deviation (PSD) for each breathing condition. A secondary, sectoral analysis of mean pointwise sensitivity was performed for each condition. In each case a P value of <.01 was considered statistically significant (Bonferroni corrected). RESULTS: Visual field MD was -0.23 ± 0.95dB during room air breathing and -0.49 ± 1.04dB during hypercapnia (P = .034). Sectoral pointwise mean sensitivity deteriorated by 0.46dB (P = .006) in the upper visual hemifield during hypercapnia, whereas no significant difference was observed for the lower hemifield (P = .331). CONCLUSIONS: The upper visual hemifield exhibited a significantly greater degree of deterioration in pointwise visual field mean sensitivity compared to the lower hemifield during hypercapnic conditions. This suggests that the upper visual hemifield and hence inferior retina is more susceptible to insult during hypercapnia than the superior retina in healthy individuals. A regional susceptibility of inferior retinal function to altered vascular or metabolic effects may account for the earlier and more frequent inferior nerve fibre damage associated with glaucomatous optic neuropathy. © 2003 by Elsevier Science Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Vigabatrin (VGB) is an anti-epileptic medication which has been linked to peripheral constriction of the visual field. Documenting the natural history associated with continued VGB exposure is important when making decisions about the risk and benefits associated with the treatment. Due to its speed the Swedish Interactive Threshold Algorithm (SITA) has become the algorithm of choice when carrying out Full Threshold automated static perimetry. SITA uses prior distributions of normal and glaucomatous visual field behaviour to estimate threshold sensitivity. As the abnormal model is based on glaucomatous behaviour this algorithm has not been validated for VGB recipients. We aim to assess the clinical utility of the SITA algorithm for accurately mapping VGB attributed field loss. Methods: The sample comprised one randomly selected eye of 16 patients diagnosed with epilepsy, exposed to VGB therapy. A clinical diagnosis of VGB attributed visual field loss was documented in 44% of the group. The mean age was 39.3 years∈±∈14.5 years and the mean deviation was -4.76 dB ±4.34 dB. Each patient was examined with the Full Threshold, SITA Standard and SITA Fast algorithm. Results: SITA Standard was on average approximately twice as fast (7.6 minutes) and SITA Fast approximately 3 times as fast (4.7 minutes) as examinations completed using the Full Threshold algorithm (15.8 minutes). In the clinical environment, the visual field outcome with both SITA algorithms was equivalent to visual field examination using the Full Threshold algorithm in terms of visual inspection of the grey scale plots, defect area and defect severity. Conclusions: Our research shows that both SITA algorithms are able to accurately map visual field loss attributed to VGB. As patients diagnosed with epilepsy are often vulnerable to fatigue, the time saving offered by SITA Fast means that this algorithm has a significant advantage for use with VGB recipients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Scientific education has been passing by redefinitions, contestations and new contributions from the research on science teaching. One contribution is the idea of science and technology literacy, allowing the citizens not only knowing science but also understand aspects on the construction and motivation of scientific and technological research. In accordance with this idea, there is the Science-Technology-Society (STS) studies which, since the 1970s, has been contributing for science teaching and learning according to the comprehension of the relationships with society in the Western countries of the North. In Brazil, this approach began to gain projection from the 1990s when the first essays on the theme were published. Currently, there is a clear influence of this approach on the national curriculum guidelines, especially for the area of Natural Sciences, and also on the textbooks chosen by the High School National Program (Programa Nacional do Ensino Médio). However, there seems to be a gap in relation to the discussion on the specific curricular component seen in college on this approach. Thus, this study aims at adopting the approach STS, face to the preparation of complimentary educational material on acid and bases concepts studied in the course of General Chemistry of the Natural Sciences graduation program. To this end, it was performed a bibliographical research aiming at making the state-of-the-art in in these concepts in specific literature to science teaching. It is divided in two stages: systematic study (with sixteen journals chosen according to Qualis-Capes and an unsystematic study with direct search in databases and references in the papers of the systematic study. The studies had their content analyzed and the categories chosen a priori were the level of education, the acid-base theory adopted, and the strategy/theoretical frame of reference adopted. A second stage aimed at identifying attitudes and beliefs on STS (Science-Technology-Society) and CSE (Chemistry-Society-Environment) of students in the teacher and technologist training course in three diferent institutions: UTFPR, UFRN and IFRN. In this study, it was used two questionnaires, composed of a Likert scale, semantic differential scale and open questions. The quantitative data reliability was estimated through Cronbach’s alpha method, and tha data were treated according to classic statistics, using the mean as the centrality measures, and the mean deviation as dispersion. The qualitative data were treated according to the content analysis with categories taken from the reading of answers. In the third stage, it was analyzed the presence of STS and CSE content in chapters on acid and bases concepts of nine General Chemistry textbooks, frequently used in graduation programs in public institutions of the state of Rio Grande do Norte. The results showed that there are few proposals of acid and bases teaching, and they are generally aimed at High School or at instrumentation for teaching courses, and no course for General Chemistry. The student’s attitudes and beliefs show the presence of a positivist point of view based on the concept of Science and Technology neutrality and the salvation of its mediation. The books analysis showed just a few content on STS and CSE are found in the studied chapters, and they are generally presented disjointedly in relation to the rest of the main text. In the end, as suggestion to solve the absence of proposals STS in General Chemistry books, as well as the student’s positivist attitudes, it was developed some educational material to be used in the course of General Chemistry at College. The material is structured to introduce a historical view of the concepts preparation, present the use of materials, the industrial and technological processes, and social and environmental consequences of this activities