918 resultados para Maximum design load


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Congress established a legal imperative to restore the quality of our surface waters when it enacted the Clean Water Act in 1972. The act requires that existing uses of coastal waters such as swimming and shellfishing be protected and restored. Enforcement of this mandate is frequently measured in terms of the ability to swim and harvest shellfish in tidal creeks, rivers, sounds, bays, and ocean beaches. Public-health agencies carry out comprehensive water-quality sampling programs to check for bacteria contamination in coastal areas where swimming and shellfishing occur. Advisories that restrict swimming and shellfishing are issued when sampling indicates that bacteria concentrations exceed federal health standards. These actions place these coastal waters on the U.S. Environmental Protection Agencies’ (EPA) list of impaired waters, an action that triggers a federal mandate to prepare a Total Maximum Daily Load (TMDL) analysis that should result in management plans that will restore degraded waters to their designated uses. When coastal waters become polluted, most people think that improper sewage treatment is to blame. Water-quality studies conducted over the past several decades have shown that improper sewage treatment is a relatively minor source of this impairment. In states like North Carolina, it is estimated that about 80 percent of the pollution flowing into coastal waters is carried there by contaminated surface runoff. Studies show this runoff is the result of significant hydrologic modifications of the natural coastal landscape. There was virtually no surface runoff occurring when the coastal landscape was natural in places such as North Carolina. Most rainfall soaked into the ground, evaporated, or was used by vegetation. Surface runoff is largely an artificial condition that is created when land uses harden and drain the landscape surfaces. Roofs, parking lots, roads, fields, and even yards all result in dramatic changes in the natural hydrology of these coastal lands, and generate huge amounts of runoff that flow over the land’s surface into nearby waterways. (PDF contains 3 pages)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Shellfish bed closures along the North Carolina coast have increased over the years seemingly concurrent with increases in population (Mallin 2000). More and faster flowing storm water has come to mean more bacteria, and fecal indicator bacterial (FIB) standards for shellfish harvesting are often exceeded when no source of contamination is readily apparent (Kator and Rhodes, 1994). Could management reduce bacterial loads if the source of the bacteria where known? Several potentially useful methods for differentiating human versus animal pollution sources have emerged including Ribotyping and Multiple Antibiotic Resistance (MAR) (US EPA, 2005). Total Maximum Daily Load (TMDL) studies on bacterial sources have been conducted for streams in NC mountain and Piedmont areas (U.S. EPA, 1991 and 2005) and are likely to be mandated for coastal waters. TMDL analysis estimates allowable pollutant loads and allocates them to known sources so management actions may be taken to restore water to its intended uses (U.S. EPA, 1991 and 2005). This project sought first to quantify and compare fecal contamination levels for three different types of land use on the coast, and second, to apply MAR and ribotyping techniques and assess their effectiveness for indentifying bacterial sources. Third, results from these studies would be applied to one watershed to develop a case study coastal TMDL. All three watershed study areas are within Carteret County, North Carolina. Jumping Run Creek and Pettiford Creek are within the White Oak River Basin management unit whereas the South River falls within the Neuse River Basin. Jumping Run Creek watershed encompasses approximately 320 ha. Its watershed was a dense, coastal pocosin on sandy, relic dune ridges, but current land uses are primarily medium density residential. Pettiford Creek is in the Croatan National Forest, is 1133 ha. and is basically undeveloped. The third study area is on Open Grounds Farm in the South River watershed. Half of the 630 ha. watershed is under cultivation with most under active water control (flashboard risers). The remaining portion is forested silviculture.(PDF contains 4 pages)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The three-stage low-pressure model steam turbine at the Institute of Thermal Turbomachinery and Machinery Laboratory (ITSM) was used to study the impact of three different steam inlet temperatures on the homogeneous condensation process and the resulting wetness topology. The droplet spectrum as well as the particle number concentration were measured in front of the last stage using an optical-pneumatic probe. At design load, condensation starts inside the stator of the second stage. A change in the steam inlet temperature is able to shift the location of condensation onset within the blade row up- or downstream and even into adjoining blade passages, which leads to significantly different local droplet sizes and wetness fractions due to different local expansion rates. The measured results are compared to steady three-dimensional computational fluid dynamics calculations. The predicted nucleation zones could be largely confirmed by the measurements. Although the trend of measured and calculated droplet size across the span is satisfactory, there are considerable differences between the measured and computed droplet spectrum and wetness fractions. © IMechE 2013 Reprints and permissions: sagepub.co.uk/ journalsPermissions.nav.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

一体化反应器由于投资少、占地小、管理运行方便等优点而备受青睐。但现有的一体化反应器大都适用于处理中低浓度废水,耐受负荷普遍偏低。本课题研制出新型高效的厌氧好氧一体化生物反应器,旨在通过反应器结构优化、高效微生物载体研制、配合高效微生物菌剂技术处理中高浓度有机废水,实现高效和低耗,降低设备造价,提高反应器运行稳定性。 首先开展了菌剂对废水的适配试验。采用15种不同的微生物菌剂,以葡萄糖配水、中药提取废水、啤酒废水、氨氮配水为基质,分别测定了微生物菌剂的耗氧速率和厌氧比产甲烷速率,以其为指标比较了各菌剂对废水的适配性。根据结果选择活性高的14#、8#、10#菌剂,在试验室进行了菌剂对废水的连续处理试验,取得良好的处理效果,为菌剂在厌氧好氧一体化生物反应器的小试、中试中的应用奠定了基础。 经小试研究后,又对厌氧好氧一体化生物反应器进行了处理发酵废水的中试研究。试验结果表明,反应器启动快,系统有机负荷2.72 kgCODm-3d-1时整个反应器去除率保持在84.5%~93.19%,在30多天内一次启动成功。冲击负荷试验中,系统总有机负荷最高可达到8.88 kgCODm-3d-1,系统去除率稳定在88.10%~96.88%,说明反应器处理效率高,抗冲击能力强。稳定运行期间,COD去除率可达90%以上,各项指标都能达到国家排放标准。 此外,对反应器配套系统高效菌剂、高分子复合颗粒载体进行了研究。结果显示,菌剂与反应器适配良好,各功能区形成了丰富、高活性的微生物,厌氧区颗粒污泥TS高达83.9 gL-1,VS/TS为56.9%~57.4%,比产甲烷活性为280~350 mLCH4 gvss-1d-1;好氧区固定化微生物TS高达1.921 gL-1,VS/TS为94.02~94.30%。对载体性能的研究表明,此高分子复合颗粒载体密度适中,易于流化,不易流失;粗糙多空,易于挂膜;且无生物毒害作用,稳定安全,是一种优良的生物载体。反应器各功能区对废水的降解过程分析,说明了反应器、菌剂、载体适配良好,在其协同作用下,实现了污染物的高效降解。 The integrated reactors were popular because of their characteristics such as little investment, small occupation of land, convenient of manage and running etc. But the present integrated reactors were mostly applied for treating wastewater of low concentration, the load tolerance was generally on the low side. A new type integrated anaerobic-aerobic bio-reactor was developed, which was conducted to treating organic wastewater of middle or high concentration by optimization of reactor structure, development of efficient microbe carrier and adaptation of high active microbial blends, to achieve high efficiency and low consume, reduce equipment cost, enhance running stabilization of reactor. The adaptability test of microbial blends on different wastewater was carried on firstly. Oxygen consumption rate and anaerobic specific activity of methane producing of 15 different microbial blends were measured separately taking glucose artificial wastewater, Chinese herb extracting wastewater, brewery wastewater and ammonia nitrogen artificial wastewater as substrate, by which the adaptabilities of different microbial blends to wastewater were compared. According to the results high active microbial blends 14#, 8# and 10# were selected and used in the continuous treatment of wastewater in the laboratory and had obtained good effect, which had laid a foundation for application microbial blends to small scale test and pilot test of integrated anaerobic-aerobic bio-reactor. After the small scale test, the pilot test of the integrated anaerobic-aerobic bio-reactor treating fermentation wastewater was carried on. The test results showed fast initiation of the reactor. When system organic load reached 2.72 kgCODm-3d-1the COD removal rate of the reactor was stable between 84.5%~93.19% and it initiated successfully in more than 30 days at a time. In the load shock test the maximum organic load of system could reach to 8.88 kgCODm-3d-1 and the COD removal rate could be stable between 88.10%~96.88% which indicated that the reactor was efficient for treating wastewater and had strong resistance to shock load. At stable running period the COD removal rate of the reactor was over 90% and each index of wastewater could reach to the national discharge standards. In addition, the high active microbial blends and the macromolecule compound granule carrier, the matching system of the reactor was studied. It showed that the microbial blends adapted well to the reactor and abundant and high active microbes were formed in each functional field. The TS of granule sludge in anaerobic field was as high as 83.9 gL-1, the VS/TS was 56.9%~57.4%, the specific activity of methane producing was 280~350 mLCH4 gvss-1d-1. And the TS of immobilized biological granule was as high as 1.921 gL-1, the VS/TS was 94.02%~94.30%. Study on the carrier showed that the self-made macromolecular compound granule carrier was moderate of density, easy of fluidization, unease of running off, rough and porous, easy of films fixation, no bio-toxic, stable and safe, was a kind of superior carrier. Analysis of degradation process in each functional field confirmed the reactor, microbial blends and carriers were in good adaptation and wastewater was decontaminated by their cooperation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

垃圾卫生填埋是国内外城市垃圾的主要处置方法。垃圾渗滤液是渗入填埋场垃圾的降水混合垃圾降解过程中产生的物质而形成的混合物,是垃圾填埋场向环境排放的主要污染物。渗滤液由于其所含高浓度有机和无机污染物,且其中很多物质有生物毒性或难生物降解,难于治理。特别是到填埋晚期,渗滤液中高浓度的氨氮更是增加了治理的难度。渗滤液场外硝化-原位反硝化是填埋场氮管理的新途径。本文利用从环境中筛选出优势硝化功能菌对渗滤液中的高浓度氨氮进行生物硝化,经硝化后的渗滤液回灌至以垃圾柱模拟的生物反应器填埋场,在填埋场内实现原位反硝化。 上述目标通过以下两部分来实现: 第一部分:渗滤液场外硝化。首先从污水厂的硝化污泥中富集并筛选出硝化功能菌,在模拟氨氮废水中优化。将驯化的硝化功能菌接种于连续式完全混合反应器(CSTR)进行高氨氮渗滤液硝化研究。在200余天的连续运行中,反应器硝化和有机物去除效果良好。在最大氨氮负荷和有机物负荷分别为0.65 g N l-1 d-1 和3.84 g COD l-1 d-1时,氨氮和COD去除率分别高于99%和57%。实验过程中发现,游离氨(FA)和溶解氧(DO)浓度对反应器中亚硝酸盐的积累影响很大。 第二部分:渗滤液原位反硝化。本文利用一个垃圾填充柱模拟生物反应器填埋场,研究了硝化渗滤液回灌对垃圾降解的影响,和回灌的硝化渗滤液中TON(总氧化态氮)对填埋场生物反应器产甲烷作用的影响。最后利用变性梯度凝胶电泳(DGGE)分析了硝化渗滤液回灌对垃圾填埋场菌群结构的影响。结果表明:回灌的TON被完全还原,反硝化为主要反应,最大TON负荷为28.6 mg N kg-1 TS d-1。当垃圾柱TON负荷大于11.4 mg N kg-1 TS d-1时,出现了产甲烷抑制,抑制作用随TON负荷的增加而加强。在此过程中,反硝化逐渐代替产甲烷作用成为填埋场内垃圾降解的主要反应,且更多产生的是清洁的氮气,而非温室气体甲烷。直到实验结束时,回灌硝化渗滤液的垃圾柱的甲烷产量仅相当于对照的2.5%,并且回灌的硝化渗滤液还加速了填埋场垃圾的降解与稳定。通过DGGE进行菌群结构分析发现,由于TON对填埋场的长期作用,反硝化菌增多而产甲烷菌减少。 Landfill still remains the chief method for MSW management around the world. Leachate is a mixture of rainfall permeating through landfill and organic and inorganic matters generated during decomposition of the wastes in the landfills, characterized as highly complicated and refractory wastewater. Ex-situ nitrification and sequential in-situ denitrification represents a novel approach to nitrogen management at landfills. In the present paper, nitrification was carried out in a continuous stirred tank reactor (CSTR) inoculated with nitrifying bacteria which were isolated from municipal WWTP of Chengdu city. The nitrified leachate from CSTR was recirculated to a lab-scale municipal solid waste (MSW) column where in-situ denitrification took place. The above object was achived through two parts as following: First, ex-situ nitification of leachate. After acclimated in simulated wastewater for 3 month, nitrifying bacteria isolated from WWTP nitrifying sludge were added to the CSTR for nitrification. The results over 200 days showed that the maximum nitrogen loading rate (NLR) and the maximum organic loading rate (OLR) was 0.65 g N l-1 d-1 and 3.84 g COD l-1 d-1, respectively. The ammonia and COD removal was over 99% and 57%, respectively. Moreover, the effects of free ammonia (FA) and dissolved oxygen (DO) on nitrification were investigated. Second, in-situ denitrification was studied in a municipal solid waste (MSW) column. Variation of nitrified leachate and its effects on the decomposition of municipal solid waste (MSW) were studied in a lab-scale MSW column to which nitrified leachate was recirculated. Additionally, DGGE was employed to investigate the microbial community of both MSW columns. The results suggested: complete reduction of total oxidized nitrogen (TON) was obtained with maximum TON load of 28.6 mg N kg-1 TS d-1 and denitrification was the main reaction responsible. Methanogenesis inhibition was observed while TON load was over 11.4 mg N kg-1 TS d-1 and the inhibition was enhanced with the increase of TON load. Denitrification gradually took over methanogenesis to become the main reaction responsible for decomposition of MSW while nitrogen gas, a clean byproduct, was generated instead. Till the end of the experiment, the average weekly methane production in the denitrification column was as low as 2.5% of that of the control, and the rate of decompition and stability of MSW was accelerated by the recirculation of the nitrified leachate.Owing to long term exposure of nitrified leachate to landfill, denitrifying bacteria increased and methanogen decreased.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Charpy impact fracture behaviour of unnotched specimens of phenolphthalein polyether ketone (PEK-C) was studied over a temperature range from room temperature to 220 degrees C by using an instrumented impact tester. The load-time and energy-time curves of PEK-C at different temperatures were recorded. From these curves, some important parameters, such as the maximum impact load, the maximum stress, the total impact energy, the crack initiation energy, the crack propagation energy etc., were obtained and their temperature dependences of PEK-C were investigated. The point of 100 percent maximum load on the load-time trace was shown to be the yield point. Two parameters, the ductile ratio (D.R.) and the ductility index (D.I.) were applied to characterize the ductility of PEK-C and their relationships to the relaxation processes were discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper examines the influence of exit separation, exit availability and seating configuration on aircraft evacuation efficiency and evacuation time. The purpose of this analysis is to explore how these parameters influence the 60-foot exit separation requirement found in aircraft certification rules. The analysis makes use of the airEXODUS evacuation model and is based on a typical wide-body aircraft cabin section involving two pairs of Type-A exits located at either end of the section with a maximum permissible loading of 220 passengers located between the exits. The analysis reveals that there is a complex relationship between exit separation and evacuation efficiency. A main finding of this work is that for the cabin section examined, with a maximum passenger load of 220 and under certification conditions, exit separations up to 170ft will result in approximately constant total evacuation times and average personal evacuation times. This practical exit separation threshold is decreased to 114ft if another combination of exits is selected. While other factors must also be considered when determining maximum allowable exit separations, these results suggest it is not possible to mandate a maximum exit separation without taking into consideration exit type, exit availability and aircraft configuration.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For many coastal regions of the world, it has been common practice to apply seaweed to the land as a soil improver and fertilizer. Seaweed is rich in arsenosugars and has a tissue concentration of arsenic up to 100 micro/g g(-1). These arsenic species are relatively nontoxic to humans; however, in the environment they may accumulate in the soil and decompose to more toxic arsenic species. The aim of this study was to determine the fate and biotransformation of these arsenosugars in soil using HPLC-ICP-MS analysis. Data from coastal soils currently manured with seaweeds were used to investigate if arsenic was accumulating in these soils. Long-term application of seaweed increased arsenic concentrations in these soils up to 10-fold (0.35 mg of As kg(-1) for nonagronomic peat, 4.3 mg of As kg(-1) for seaweed-amended peat). The biotransformation of arsenic was studied in microcosm experiments in which a sandy (machair) soil, traditionally manured with seaweed, was amended with Laminaria digitata and Fucus vesiculosus. In both seaweed species, the arsenic occurs in the form of arsenosugars (85%). The application of 50 g of seaweed to 1 kg of soil leads to an increase of arsenic in the soils, and the dominating species found in the soil pore water were dimethylarsinic acid (DMA(V)) and the inorganic species arsenate (As(V)) and arsenite (As(III)) after the initial appearance of arsenosugars. A proposed decomposition pathway of arsenosugars is discussed in which the arsenosugars are transformed to DMA(V) and further to inorganic arsenic without appreciable amounts of methylarsonic acid (MA(V)). Commercially available seaweed-based fertilizers contain arsenic concentration between 10 and 50 mg kg(-1). The arsenic species in these fertilizers depends on the manufacturing procedure. Some contain mainly arsenosugars while others contain mainly DMA(V) and inorganic arsenic. With the application rates suggested by the manufacturers, the application of these fertilizers is 2 orders of magnitude lower than the maximum permissible sewage sludge load for arsenic (varies from 0.025 kg ha(-1) yr(-1) in Styria, Austria, to 0.7 kg ha(-1) yr(-1) in the U.K.), while a direct seaweed application would exceed the maximum arsenic load by at least a factor of 2.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Demand Side Management (DSM) programmes are designed to shift electrical loads from peak times. Demand Response (DR) algorithms automate this process for controllable loads. DR can be implemented explicitly in terms of Peak to Average Ratio Reduction (PARR), in which case the maximum peak load is minimised over a prediction horizon by manipulating the amount of energy given to controllable loads at different times. A hierarchical predictive PARR algorithm is presented here based on Dantzig-Wolfe decomposition. © 2013 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trabalho Final de Mestrado elaborado no Laboratório Nacional de Engenharia Civil (LNEC) para a obtenção do grau de Mestre em Engenharia Civil pelo Instituto Superior de Engenharia de Lisboa no âmbito do protocolo de cooperação entre o ISEL e o LNEC

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study envisaged herein contains the numerical investigations on Perforated Plate (PP) as well as numerical and experimental investigations on Perforated Plate with Lining (PPL) which has a variety of applications in underwater engineering especially related to defence applications. Finite element method has been adopted as the tool for analysis of PP and PPL. The commercial software ANSYS has been used for static and free vibration response evaluation, whereas ANSYS LS-DYNA has been used for shock analysis. SHELL63, SHELL93, SOLID45, SOLSH190, BEAM188 and FLUID30 finite elements available in the ANSYS library as well as SHELL193 and SOLID194 available in the ANSYS LS-DYNA library have been made use of. Unit cell of the PP and PPL which is a miniature of the original plate with 16 perforations have been used. Based upon the convergence characteristics, the utility of SHELL63 element for the analysis of PP and PPL, and the required mesh density are brought out. The effect of perforation, geometry and orientation of perforation, boundary conditions and lining plate are investigated for various configurations. Stress concentration and deflection factor are also studied. Based on these investigations, stadium geometry perforation with horizontal orientation is recommended for further analysis.Linear and nonlinear static analysis of PP and PPL subjected to unit normal pressure has been carried out besides the free vibration analysis. Shock analysis has also been carried out on these structural components. The analytical model measures 0.9m x 0.9m with stiffener of 0.3m interval. The influence of finite element, boundary conditions, and lining plate on linear static response has been estimated and presented. Comparison of behavior of PP and PPL in the nonlinear strain regime has been made using geometric nonlinear analysis. Free vibration analysis of the PP and PPL has been carried out ‘in vacuum’ condition and in water backed condition, and the influence of water backed condition and effect of perforation on natural frequency have been investigated.Based upon the studies on the vibration characteristics of NPP, PP and PPL in water backed condition and ‘in vacuum’ condition, the reduction in the natural frequency of the plate in immersed condition has been rightly brought out. The necessity to introduce the effect of water medium in the analysis of water backed underwater structure has been highlighted.Shock analysis of PP and PPL for three explosives viz., PEK, TNT and C4 has been carried out and deflection and stresses on plate as well as free field pressure have been estimated using ANSYS LS-DYNA. The effect of perforations and the effect of lining plate have been predicted. Experimental investigations of the measurement of free field pressure using PPL have been conducted in a shock tank. Free field pressure has been measured and has been validated with finite element analysis results. Besides, an experiment has been carried out on PPL, for the comparison of the static deflection predicted by finite element analysis.The distribution of the free field pressure and the estimation of differential pressure from experimentation and the provision for treating the differential pressure as the resistance, as a part of the design load for PPL, has been brought out.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Warships are generally sleek, slender with V shaped sections and block coefficient below 0.5, compared to fuller forms and higher values for commercial ships. They normally operate in the higher Froude number regime, and the hydrodynamic design is primarily aimed at achieving higher speeds with the minimum power. Therefore the structural design and analysis methods are different from those for commercial ships. Certain design guidelines have been given in documents like Naval Engineering Standards and one of the new developments in this regard is the introduction of classification society rules for the design of warships.The marine environment imposes subjective and objective uncertainties on ship structure. The uncertainties in loads, material properties etc.,. make reliable predictions of ship structural response a difficult task. Strength, stiffness and durability criteria for warship structures can be established by investigations on elastic analysis, ultimate strength analysis and reliability analysis. For analysis of complicated warship structures, special means and valid approximations are required.Preliminary structural design of a frigate size ship has been carried out . A finite element model of the hold model, representative of the complexities in the geometric configuration has been created using the finite element software NISA. Two other models representing the geometry to a limited extent also have been created —- one with two transverse frames and the attached plating alongwith the longitudinal members and the other representing the plating and longitudinal stiffeners between two transverse frames. Linear static analysis of the three models have been carried out and each one with three different boundary conditions. The structural responses have been checked for deflections and stresses against the permissible values. The structure has been found adequate in all the cases. The stresses and deflections predicted by the frame model are comparable with those of the hold model. But no such comparison has been realized for the interstiffener plating model with the other two models.Progressive collapse analyses of the models have been conducted for the three boundary conditions, considering geometric nonlinearity and then combined geometric and material nonlinearity for the hold and the frame models. von Mises — lllyushin yield criteria with elastic-perfectly plastic stress-strain curve has been chosen. ln each case, P-Delta curves have been generated and the ultimate load causing failure (ultimate load factor) has been identified as a multiple of the design load specified by NES.Reliability analysis of the hull module under combined geometric and material nonlinearities have been conducted. The Young's Modulus and the shell thickness have been chosen as the variables. Randomly generated values have been used in the analysis. First Order Second Moment has been used to predict the reliability index and thereafter, the probability of failure. The values have been compared against standard values published in literature.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Numerous studies have proven an effect of a probable climate change on the hydrosphere’s different subsystems. In the 21st century global and regional redistribution of water has to be expected and it is very likely that extreme weather phenomenon will occur more frequently. From a global view the flood situation will exacerbate. In contrast to these discoveries the classical approach of flood frequency analysis provides terms like “mean flood recurrence interval”. But for this analysis to be valid there is a need for the precondition of stationary distribution parameters which implies that the flood frequencies are constant in time. Newer approaches take into account extreme value distributions with time-dependent parameters. But the latter implies a discard of the mentioned old terminology that has been used up-to-date in engineering hydrology. On the regional scale climate change affects the hydrosphere in various ways. So, the question appears to be whether in central Europe the classical approach of flood frequency analysis is not usable anymore and whether the traditional terminology should be renewed. In the present case study hydro-meteorological time series of the Fulda catchment area (6930 km²), upstream of the gauging station Bonaforth, are analyzed for the time period 1960 to 2100. At first a distributed catchment area model (SWAT2005) is build up, calibrated and finally validated. The Edertal reservoir is regulated as well by a feedback control of the catchments output in case of low water. Due to this intricacy a special modeling strategy has been necessary: The study area is divided into three SWAT basin models and an additional physically-based reservoir model is developed. To further improve the streamflow predictions of the SWAT model, a correction by an artificial neural network (ANN) has been tested successfully which opens a new way to improve hydrological models. With this extension the calibration and validation of the SWAT model for the Fulda catchment area is improved significantly. After calibration of the model for the past 20th century observed streamflow, the SWAT model is driven by high resolution climate data of the regional model REMO using the IPCC scenarios A1B, A2, and B1, to generate future runoff time series for the 21th century for the various sub-basins in the study area. In a second step flood time series HQ(a) are derived from the 21st century runoff time series (scenarios A1B, A2, and B1). Then these flood projections are extensively tested with regard to stationarity, homogeneity and statistical independence. All these tests indicate that the SWAT-predicted 21st-century trends in the flood regime are not significant. Within the projected time the members of the flood time series are proven to be stationary and independent events. Hence, the classical stationary approach of flood frequency analysis can still be used within the Fulda catchment area, notwithstanding the fact that some regional climate change has been predicted using the IPCC scenarios. It should be noted, however, that the present results are not transferable to other catchment areas. Finally a new method is presented that enables the calculation of extreme flood statistics, even if the flood time series is non-stationary and also if the latter exhibits short- and longterm persistence. This method, which is called Flood Series Maximum Analysis here, enables the calculation of maximum design floods for a given risk- or safety level and time period.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study reported here is part of a large project for evaluation of the Thermo-Chemical Accumulator (TCA), a technology under development by the Swedish company ClimateWell AB. The studies concentrate on the use of the technology for comfort cooling. This report concentrates on measurements in the laboratory, modelling and system simulation. The TCA is a three-phase absorption heat pump that stores energy in the form of crystallised salt, in this case Lithium Chloride (LiCl) with water being the other substance. The process requires vacuum conditions as with standard absorption chillers using LiBr/water. Measurements were carried out in the laboratories at the Solar Energy Research Center SERC, at Högskolan Dalarna as well as at ClimateWell AB. The measurements at SERC were performed on a prototype version 7:1 and showed that this prototype had several problems resulting in poor and unreliable performance. The main results were that: there was significant corrosion leading to non-condensable gases that in turn caused very poor performance; unwanted crystallisation caused blockages as well as inconsistent behaviour; poor wetting of the heat exchangers resulted in relatively high temperature drops there. A measured thermal COP for cooling of 0.46 was found, which is significantly lower than the theoretical value. These findings resulted in a thorough redesign for the new prototype, called ClimateWell 10 (CW10), which was tested briefly by the authors at ClimateWell. The data collected here was not large, but enough to show that the machine worked consistently with no noticeable vacuum problems. It was also sufficient for identifying the main parameters in a simulation model developed for the TRNSYS simulation environment, but not enough to verify the model properly. This model was shown to be able to simulate the dynamic as well as static performance of the CW10, and was then used in a series of system simulations. A single system model was developed as the basis of the system simulations, consisting of a CW10 machine, 30 m2 flat plate solar collectors with backup boiler and an office with a design cooling load in Stockholm of 50 W/m2, resulting in a 7.5 kW design load for the 150 m2 floor area. Two base cases were defined based on this: one for Stockholm using a dry cooler with design cooling rate of 30 kW; one for Madrid with a cooling tower with design cooling rate of 34 kW. A number of parametric studies were performed based on these two base cases. These showed that the temperature lift is a limiting factor for cooling for higher ambient temperatures and for charging with fixed temperature source such as district heating. The simulated evacuated tube collector performs only marginally better than a good flat plate collector if considering the gross area, the margin being greater for larger solar fractions. For 30 m2 collector a solar faction of 49% and 67% were achieved for the Stockholm and Madrid base cases respectively. The average annual efficiency of the collector in Stockholm (12%) was much lower than that in Madrid (19%). The thermal COP was simulated to be approximately 0.70, but has not been possible to verify with measured data. The annual electrical COP was shown to be very dependent on the cooling load as a large proportion of electrical use is for components that are permanently on. For the cooling loads studied, the annual electrical COP ranged from 2.2 for a 2000 kWh cooling load to 18.0 for a 21000 kWh cooling load. There is however a potential to reduce the electricity consumption in the machine, which would improve these figures significantly. It was shown that a cooling tower is necessary for the Madrid climate, whereas a dry cooler is sufficient for Stockholm although a cooling tower does improve performance. The simulation study was very shallow and has shown a number of areas that are important to study in more depth. One such area is advanced control strategy, which is necessary to mitigate the weakness of the technology (low temperature lift for cooling) and to optimally use its strength (storage).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 9-month study of four relocatable school buildings, each retro-fitted with small reverse cycle air conditioners (ACs), was conducted to investigate their effectiveness in heating and cooling the classrooms. A comparison with data from previous studies found the energy used by the ACs for heating these temporary classrooms was only 19–20% of the energy used by individual gas heaters installed in permanent classrooms. When equipment efficiencies were considered, the AC units supplied 20–27% less energy to heat the classrooms. The possible reasons for this reduction in supplied energy are explored in this paper. CO2 emissions for the AC units in heating mode, however, were calculated to be 16% greater than for individual gas heaters. The AC units were also used for cooling and on an average the total annual energy consumption for heating and cooling was found to be 11.6 kWh m−2. Responses to a small survey of staff and students about the use and operation of the conditioners are presented. Their responses were more favourable than the predictions of comfort levels in the classrooms using the Predicted Mean Vote–Predicted Percentage of Dissatisfaction (PMV–PPD) model, which indicated “uncomfortable” conditions on average summer days at 3:00 p.m. and average winter days at 10:00 a.m. Background noise levels in the classrooms with the air conditioners in use were above the recommended maximum design level of 45 dB(A); levels of up to 65 dB(A) were measured.