923 resultados para Maxillofacial prosthesis implantation
Resumo:
INTRODUCTION: Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE: To describe our initial experience of the percutaneous treatment of MR with the MitraClip device. METHODS: We describe the first six MitraClip cases performed in this institution (mean age 58.5 ± 13.1 years), with functional MR grade 4+ and New York Heart Association (NYHA) heart failure class III or IV (n=3), with a mean follow-up of 290 ± 145 days. RESULTS: Procedural success (MR ≤ 2+) was 100%. Total procedure time was 115.8 ± 23.7 min, with no in-hospital adverse events and discharge between the fourth and eighth day, and consistent improvement in the six-minute walk test (329.8 ± 98.42 vs. 385.33 ± 106.95 m) and in NYHA class (three patients improved by two NYHA classes). During follow-up there were two deaths, in two of the four patients who had been initially considered for heart transplantation. CONCLUSION: In patients with functional MR the MitraClip procedure is safe, with both a high implantation and immediate in-hospital success rate. A longer follow-up suggests that the clinical benefit decreases or disappears completely in patients with more advanced heart disease, namely those denied transplantation or on the heart transplant waiting list.
Resumo:
We reviewed our surgery registry, to identify predictive risk factors for operative results, and to analyse the long-term survival outcome in octogenarians operated for primary isolated aortic valve replacement (AVR). A total of 124 consecutive octogenarians underwent open AVR from January 1990 to December 2005. Combined procedures and redo surgery were excluded. Selected variables were studied as risk factors for hospital mortality and early neurological events. A follow-up (FU; mean FU time: 77 months) was obtained (90% complete), and Kaplan-Meier plots were used to determine survival rates. The mean age was 82+/-2.2 (range: 80-90 years; 63% females). Of the group, four patients (3%) required urgent procedures, 10 (8%) had a previous myocardial infarction, six (5%) had a previous coronary angioplasty and stenting, 13 patients (10%) suffered from angina and 59 (48%) were in the New York Heart Association (NYHA) class III-IV. We identified 114 (92%) degenerative stenosis, six (5%) post-rheumatic stenosis and four (3%) active endocarditis. The predicted mortality calculated by logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) was 12.6+/-5.7%, and the observed hospital mortality was 5.6%. Causes of death included severe cardiac failure (four patients), multi-organ failure (two) and sepsis (one). Complications were transitory neurological events in three patients (2%), short-term haemodialysis in three (2%), atrial fibrillation in 60 (48%) and six patients were re-operated for bleeding. Atrio-ventricular block, myocardial infarction or permanent stroke was not detected. The age at surgery and the postoperative renal failure were predictors for hospital mortality (p value <0.05), whereas we did not find predictors for neurological events. The mean FU time was 77 months (6.5 years) and the mean age of surviving patients was 87+/-4 years (81-95 years). The actuarial survival estimates at 5 and 10 years were 88% and 50%, respectively. Our experience shows good short-term results after primary isolated standard AVR in patients more than 80 years of age. The FU suggests that aortic valve surgery in octogenarians guarantees satisfactory long-term survival rates and a good quality of life, free from cardiac re-operations. In the era of catheter-based aortic valve implantation, open-heart surgery for AVR remains the standard of care for healthy octogenarians.
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.
Resumo:
The indication for pulmonary artery banding is currently limited by several factors. Previous attempts have failed to produce adjustable pulmonary artery banding with reliable external regulation. An implantable, telemetrically controlled, battery-free device (FloWatch) developed by EndoArt SA, a medical company established in Lausanne, Switzerland, for externally adjustable pulmonary artery banding was evaluated on minipigs and proved to be effective for up to 6 months. The first human implant was performed on a girl with complete atrioventricular septal defect with unbalanced ventricles, large patent ductus arteriosus and pulmonary hypertension. At one month of age she underwent closure of the patent ductus arteriosus and FloWatch implantation around the pulmonary artery through conventional left thoracotomy. The surgical procedure was rapid and uneventful. During the entire postoperative period bedside adjustments (narrowing or release of pulmonary artery banding with echocardiographic assessment) were repeatedly required to maintain an adequate pressure gradient. The early clinical results demonstrated the clinical benefits of unlimited external telemetric adjustments. The next step will be a multi-centre clinical trial to confirm the early results and adapt therapeutic strategies to this promising technology.
Resumo:
PRINCIPLES: This retrospective study analyzes the long-term results of endoscopic and surgical treatment of vesico-ureteral reflux in children. METHODS: A cohort of 130 patients, 67 girls and 63 boys with a mean age of 30 months were treated either by endoscopic subureteral collagen injection (SCIN) in 92 and by Cohen reimplantation surgery in 123 refluxing ureteral units. Mean follow-up was 4.2 years varying from 1 to 8.7 years. Reflux recurrence, urinary tract infection (UTI) and renal function were evaluated. RESULTS: After SCIN reflux was absent in 64% at 6 months. 20% of the initially 92 refluxing ureters were injected twice. After one or two injections reflux was absent in 71%. In 21% recurrent reflux was of grade I or II, not requiring further treatment. UTI was observed in 27%. After Cohen ureteral reimplantation reflux was absent in 96% at 6 months. UTI was observed in 23%. Renal function at diagnosis and follow-up was compared in children with bilateral grade III reflux only. In patients treated with SCIN it was normal in 77% preoperatively and in 90% at follow-up. In patients treated by open surgery it was normal in 47% preoperatively and in 76% at follow-up. CONCLUSION: For high-grade vesico-ureteral reflux re-implantation surgery remains the gold standard. SCIN is indicated for low and medium grade reflux. Recurrent bacteriuria was observed more often after SCIN and pyelonephritis more often after open surgery. The renal function seems to be preserved with both techniques.
Resumo:
PURPOSE: Incisional hernia (IH) is one of the most frequent postoperative complications. Of all patients undergoing IH repair, a vast amount have a hernia which can be defined as a large incisional hernia (LIH). The aim of this study is to identify the preferred technique for LIH repair. METHODS: A systematic review of the literature was performed and studies describing patients with IH with a diameter of 10 cm or a surface of 100 cm2 or more were included. Recurrence hazards per year were calculated for all techniques using a generalized linear model. RESULTS: Fifty-five articles were included, containing 3,945 LIH repairs. Mesh reinforced techniques displayed better recurrence rates and hazards than techniques without mesh reinforcement. Of all the mesh techniques, sublay repair, sandwich technique with sublay mesh and aponeuroplasty with intraperitoneal mesh displayed the best results (recurrence rates of <3.6%, recurrence hazard <0.5% per year). Wound complications were frequent and most often seen after complex LIH repair. CONCLUSIONS: The use of mesh during LIH repair displayed the best recurrence rates and hazards. If possible mesh in sublay position should be used in cases of LIH repair.
Resumo:
OBJECTIVES: To learn upon incidence, underlying mechanisms and effectiveness of treatment strategies in patients with central airway and pulmonary parenchymal aorto-bronchial fistulation after thoracic endovascular aortic repair (TEVAR). METHODS: Analysis of an international multicentre registry (European Registry of Endovascular Aortic Repair Complications) between 2001 and 2012 with a total caseload of 4680 TEVAR procedures (14 centres). RESULTS: Twenty-six patients with a median age of 70 years (interquartile range: 60-77) (35% female) were identified. The incidence of either central airway (aorto-bronchial) or pulmonary parenchymal (aorto-pulmonary) fistulation (ABPF) in the entire cohort after TEVAR in the study period was 0.56% (central airway 58%, peripheral parenchymal 42%). Atherosclerotic aneurysm formation was the leading indication for TEVAR in 15 patients (58%). The incidence of primary endoleaks after initial TEVAR was n = 10 (38%), of these 80% were either type I or type III endoleaks. Fourteen patients (54%) developed central left bronchial tree lesions, 11 patients (42%) pulmonary parenchymal lesions and 1 patient (4%) developed a tracheal lesion. The recognized mechanism of ABPF was external compression of the bronchial tree in 13 patients (50%), the majority being due to endoleak formation, further ischaemia due to extensive coverage of bronchial feeding arteries in 3 patients (12%). Inflammation and graft erosion accounted for 4 patients (30%) each. Cumulative survival during the entire study period was 39%. Among deaths, 71% were attributed to ABPF. There was no difference in survival in patients having either central airway or pulmonary parenchymal ABPF (33 vs 45%, log-rank P = 0.55). Survival with a radical surgical approach was significantly better when compared with any other treatment strategy in terms of overall survival (63 vs 32% and 63 vs 21% at 1 and 2 years, respectively), as well as in terms of fistula-related survival (63 vs 43% and 63 vs 43% at 1 and 2 years, respectively). CONCLUSIONS: ABPF is a rare but highly lethal complication after TEVAR. The leading mechanism behind ABPF seems to be a continuing external compression of either the bronchial tree or left upper lobe parenchyma. In this setting, persisting or newly developing endoleak formation seems to play a crucial role. Prognosis does not differ in patients with central airway or pulmonary parenchymal fistulation. Radical bronchial or pulmonary parenchymal repair in combination with stent graft removal and aortic reconstruction seems to be the most durable treatment strategy.
Resumo:
Objetivos: Identificar predictores de recuperación de la función ventricular izquierda y comparar los hallazgos ecocardiográficos en pacientes con estenosis aórtica crítica sometidos a reemplazo quirúrgico de la válvula aórtica (RVA) o implantación de válvula aórtica transcatéter (TAVI). Métodos: Cuarenta y cuatro pacientes tratados con RVA se compararon con 34 pacientes con TAVI, los datos ecocardiográficos fueron retrospectivamente obtenidos antes de la intervención y previo al alta. Resultados: Se analizaron retrospectivamente pacientes tratados en la FCI - IC desde 2009 - 2015 (n = 78 pacientes, con una media de edad 70,29 ± 11,63, EuroSCORE logístico 3,75 (3-8,55) en RVA y 20,4 (15 , 47-23,32) en TAVI. Ambos grupos mostraron una disminución en los gradientes de la válvula aórtica, más en pacientes de TAVI, con un gradiente transaórtico pico (24,5 vs 18,5, p = 0,001) y medio (14 vs 10, p = 0,002) En comparación con RVA, TAVI presentó un mayor número de pacientes con insuficiencia aórtica paravalvular (47,1% frente a 2,3% p = 0.000). En total, el 61,5% presentó mejoría precoz de la función ventricular, el predictor en severo compromiso de la función del ventrículo izquierdo fue un alto índice de masa ventricular izquierda. Conclusiones: La implantación transcatéter de válvula aórtica es una alternativa al reemplazo quirúrgico de la válvula aórtica en pacientes con estenosis aórtica y alto riesgo quirúrgico. La recuperación postoperatoria precoz de la función ventricular izquierda en pacientes con severo compromiso de la función ventricular estuvo asociada a alto índice de masa ventricular izquierda.
Resumo:
Osseointegrated implants in craniofacial reconstructions improve prostheses retention and stability and comfort and safety for a patient. According to biomechanical principles, the treatment success regarding osseointegration maintenance depends on an adequate surgical technique associated to a retention system that provides favorable tension distribution to implants. Furthermore, patient expectation, esthetics, function, and anatomic limitations must be evaluated during treatment planning. Therefore, the aims of this study were to present available retention systems to implant-supported craniofacial prosthesis and to highlight the advantages, indications, and limitations. A literature review was conducted through a MEDLINE search. Sixteen articles and 2 textbooks met the inclusion criteria and were included in the review. It was concluded that the success of craniofacial rehabilitation with implants depends on an adequate surgical technique and an adequate selection of a retention system.
Resumo:
Although tumors of minor salivary glands are rare, the pleomorphic adenoma is the most common pathology among the benign neoplasm and can be found with high prevalence in the junction between hard palate and soft palate. The treatment of choice for most of maxillary tumors is surgical through either a total or partial maxillectomy. However, surgical defects caused by such type of treatment lead to both clinical and psychologic disorders for the patient. The immediate oral rehabilitation using interim palate obturator after maxillectomy provides optimization on the healing process, recovers the stomatognathic functions after surgery, and avoids psychosocial sequelae for the patients. This clinical report aimed to present the rehabilitation with immediate palate obturator of a patient who underwent a partial maxillectomy due to a hard palate pleomorphic adenoma of minor salivary glands. We report the clinical importance of the prosthetic rehabilitation and the improvements on both quality of life and stomatognathic functions of this patient. It can be concluded that the immediate rehabilitation of the patient after partial maxillectomy by using an interim palate obturator was a great option and provided clinical benefits in the immediate postoperative period, improving the patient's quality of life, allowing the patient's reinsertion into society, and reducing the surgical treatment sequelae.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The health of a peri-implant tissue is a critical factor for the long-term success of treatment with extraoral implants. However, infection and inflammation may occur and lead to implant loss and prostheses failure. Therefore, some postsurgical care as hygiene with soap and water, soft toothbrush, and Superfloss type dental floss and medication with anti-inflammatory and antibiotic are suggested to avoid complications. In addition, a thin and smooth layer of subcutaneous tissue in the peri-implant area should be preserved during implant insertion to favor the assistance recommended in this phase.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)