944 resultados para MICROFLUIDIC CHIPS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a light sheet based imaging flow cytometry technique for simultaneous counting and imaging of cells on a microfluidic platform. Light sheet covers the entire microfluidic channel and thus omits the necessity of flow focusing and point scanning based technology. Another advantage lies in the orthogonal detection geometry that totally cuts-off the incident light, thereby substantially reducing the background in the detection. Compared to the existing state-of-art techniques the proposed technique shows marked improvement. Using fluorescently-coated Saccharomyces cerevisiae cells we have recorded cell counting with throughput as high as 2,090 cells/min in the low flow rate regime and were able to image the individual cells on-the-go. Overall, the proposed system is cost-effective and simple in channel geometry with the advantage of efficient counting in operational regime of low laminar flow. This technique may advance the emerging field of microfluidic based cytometry for applications in nanomedicine and point of care diagnostics. Microsc. Res. Tech. 76:1101-1107, 2013. (c) 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method to study the air bubble dynamics and to burst the air bubbles formed on the electrode– electrolyte interface in a parallel gate electrode fluidic channel is demonstrated. Upon application of a voltage across the electrodes,volume of water contained between them begins to electrolyzing depending on the conductivity, as well as it boils due to heating effect. This results in bubble formation within. These bubbles grow in radius with higher potential difference applied across the electrodes. As an approach towards removing these bubbles, an alternating current is applied at low potential difference of a 5 volts and high frequency at few megahertz. The alternating electric field had a heating effect on the bubbles where the energy input due to current heats up water and bursts the bubble. The bubbles of size up to 480μm were burst at 2500 V/m using this approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microfluidic/optofluidic microscopy is a versatile modality for imaging and analyzing properties of cells/particles while they are in flow. In this paper, we demonstrate the integration of fused silica microfluidics fabricated using femtosecond laser machining into optofluidic imaging systems. By using glass for the sample stage of our microscope, we have exploited its superior optical quality for imaging and bio-compatibility. By integrating these glass microfluidic devices into a custom-built bright field microscope, we have been able to image red blood cells in flow with high-throughputs and good fidelity. In addition, we also demonstrate imaging as well as detection of fluorescent beads with these microfluidic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Morphological changes in cells associated with disease states are often assessed using clinical microscopy. However, the changes in chemical composition of cells can also be used to detect disease conditions. Optical absorption measurements carried out on single cells using inexpensive sources, detectors can help assess the chemical composition of cells; thereby enable detection of diseases. In this article, we present a novel technique capable of simultaneously detecting changes in morphology and chemical composition of cells. The presented technique enables characterization of optical absorbance-based methods against microscopy for detection of disease states. Using the technique, we have been able to achieve a throughput of about 1000 cells per second. We demonstrate the proof-of-principle by detecting malaria in a given blood sample. The presented technique is capable of detecting very lower levels of parasitemia within time scales comparable to antigen-based rapid diagnostic tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we present a novel approach to throughput enhancement in miniaturized microfluidic microscopy systems. Using the presented approach, we demonstrate an inexpensive yet high-throughput analytical instrument. Using the high-throughput analytical instrument, we have been able to achieve about 125,880 cells per minute (more than one hundred and twenty five thousand cells per minute), even while employing cost-effective low frame rate cameras (120 fps). The throughput achieved here is a notable progression in the field of diagnostics as it enables rapid quantitative testing and analysis. We demonstrate the applicability of the instrument to point-of-care diagnostics, by performing blood cell counting. We report a comparative analysis between the counts (in cells per mu l) obtained from our instrument, with that of a commercially available hematology analyzer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the fabrication of microfluidc-nanofluidic channels on Si incorporated with embedded metallic interconnects. The device aids the study of motion of dispersed particles relative to the fluid under the influence of spatially uniform electric field. Optical lithography in combination with focused ion beam technique was used to fabricate the microfluidic-nanofluidic channels, respectively. Focused ion beam technique was also used for embedding the electrodes in the nanochannel. Gold contact pads were deposited using sputtering. The substrate was finally anodically bonded to a glass substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SAW devices were fabricated on c-axis oriented ZnO films grown on Si substrates. Effects of film thickness on the film microstructure and acoustic frequencies were studied. Both Rayleigh and Sezawa mode waves were detected on the devices, and their resonant frequencies were found to decrease with increase in film thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SAW devices were fabricated on c-axis oriented ZnO films grown on Si substrates. Effects of film thickness on the film microstructure and acoustic frequencies were studied. Both Rayleigh and Sezawa mode waves were detected on the devices, and their resonant frequencies were found to decrease with increase in film thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A label-free protein microfluidic array for immunoassays based on the combination of imaging ellipsometry and an integrated microfluidic system is presented. Proteins can be patterned homogeneously on substrate in array format by the microfluidic system simultaneously. After preparation, the protein array can be packed in the microfluidic system which is full of buffer so that proteins are not exposed to denaturing conditions. With simple microfluidic channel junction, the protein microfluidic array can be used in serial or parallel format to analyze single or multiple samples simultaneously. Imaging ellipsometry is used for the protein array reading with a label-free format. The biological and medical applications of the label-free protein microfluidic array are demonstrated by screening for antibody–antigen interactions, measuring the concentration of the protein solution and detecting five markers of hepatitis B.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combined detection system involving simultaneous LIF and contactless-conductometric measurements at the same place of the microfluidic chip was described. The LIF measurement was designed according to the confocal principle and a moveable contactless-conductivity detector was used in (CD)-D-4. Both measurements were mutually independent and advantageous in analyses of mixtures. Various experimental parameters affecting the response were examined and optimized. The performances were demonstrated by simultaneous detection of Rhodamine B. And the results showed that the combined detection system could be used sensitively and reliably. (C) 2008 Yong Yu. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The uniqThe unique lamellar chips formed in turning–machining of a Vit 1 bulk metallic glass (BMG) are found to be due to repeated shearband formation in the primary shear zone (PSZ). A coupled thermomechanical orthogonal cutting model, taking into account force, free volume and energy balance in the PSZ, is developed to quantitatively characterize lamellar chip formation. Its onset criterion is revealed through a linear perturbation analysis. Lamellar chip formation is understood as a self-sustained limit-cycle phenomenon: there is autonomous feedback in stress, free volume and temperature in the PSZ. The underlying mechanism is the symmetry breaking of free volume flow and source, rather than thermal instability. These results are fundamentally useful for machining BMGs and even for understanding the physical nature of inhomogeneous flow in BMGs.ue lamellar chips formed in turning–machining of a Vit 1 bulk metallic glass (BMG) are found to be due to repeated shearband.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(dimethylsiloxane) (PDMS) is usually considered as a dielectric material and the PDMS microchannel wall can be treated as an electrically insulated boundary in an applied electric field. However, in certain layouts of microfluidic networks, electrical leakage through the PDMS microfluidic channel walls may not be negligible, which must be carefully considered in the microfluidic circuit design. In this paper, we report on the experimental characterization of the electrical leakage current through PDMS microfluidic channel walls of different configurations. Our numerical and experimental studies indicate that for tens of microns thick PDMS channel walls, electrical leakage through the PDMS wall could significantly alter the electrical field in the main channel. We further show that we can use the electrical leakage through the PDMS microfluidic channel wall to control the electrolyte flow inside the microfluidic channel and manipulate the particle motion inside the microfluidic channel. More specifically, we can trap individual particles at different locations inside the microfluidic channel by balancing the electroosmotic flow and the electrophoretic migration of the particle.