959 resultados para MEASURING METHODS


Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To compare three different methods of falls reporting and examine the characteristics of the data missing from the hospital incident reporting system. DESIGN: Fourteen-month prospective observational study nested within a randomized controlled trial. SETTING: Rehabilitation, stroke, medical, surgical, and orthopedic wards in Perth and Brisbane, Australia. PARTICIPANTS: Fallers (n5153) who were part of a larger trial (1,206 participants, mean age 75.1 � 11.0). MEASUREMENTS: Three falls events reporting measures: participants’ self-report of fall events, fall events reported in participants’ case notes, and falls events reported through the hospital reporting systems. RESULTS: The three reporting systems identified 245 falls events in total. Participants’ case notes captured 226 (92.2%) falls events, hospital incident reporting systems captured 185 (75.5%) falls events, and participant selfreport captured 147 (60.2%) falls events. Falls events were significantly less likely to be recorded in hospital reporting systems when a participant sustained a subsequent fall, (P5.01) or when the fall occurred in the morning shift (P5.01) or afternoon shift (P5.01). CONCLUSION: Falls data missing from hospital incident report systems are not missing completely at random and therefore will introduce bias in some analyses if the factor investigated is related to whether the data ismissing.Multimodal approaches to collecting falls data are preferable to relying on a single source alone.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An optical diagnostic system consisting of the Michelson interferometer with the image processor has been developed for the study of the kinetics of the thermal capillary convection. The capillary convection, surface deformation, surface wave and the velocity field in a rectangular cavity with different temperature's sidewalls have been investigated by optical interference method and PIV technique. In order to calculate the surface deformation from the interference fringe, Fourier transformation is used to grating analysis. The quantitative results of the surface deformation and surface wave have been calculated from the interference fringe pattern.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper reviews the methods for measuring the economic cost of conflict. Estimating the economic costs of conflict requires a counterfactual calculation, which makes this a very difficult task. Social researchers have resorted to different estimation methods depending on the particular effect in question. The method used in each case depends on the units being analyzed (firms, sectors, regions or countries), the outcome variable under study (aggregate output, market valuation of firms, market shares, etc.) and data availability (a single cross-section, time series or panel data). This paper reviews existing methods used in the literature to assess the economic impact of conflict: cost accounting, cross-section methods, time series methods, panel data methods, gravity models, event studies, natural experiments and comparative case studies. The paper ends with a discussion of cost estimates and directions for further research.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An improved optical self-heterodyne method utilizing a distributed Bragg reflector (DBR) tunable laser and an optical fiber ring interferometer is presented in this paper. The interference efficiency can be increased by 7 dB compared with the scheme using the conventional Mach-Zehnder interferometer. The unsteady process that the beating frequency experiences in each tuning period is investigated. According to the measurement results, the wavelength and optical power of the tunable laser will be steady when the square-wave frequency is lower than 300 kHz. It has been shown that when a square-wave voltage is applied to the phase section of the tunable laser, the laser linewidths vary in a wide range, and are much larger than that under dc voltage tuning. The errors caused by the variations in the linewidth of the beat signal and optical power can be eliminated using the proposed calibration procedures, and the measurement accuracy can, therefore, be significantly improved. Experiments show that the frequency responses obtained using our method agree well with the data provided by the manufacturer, and the improved optical self-heterodyne method is as accurate as the intensity noise technique.