983 resultados para Low-pass filter
Resumo:
A water desaturation zone develops around a tunnel in water-saturated rock when the evaporative water loss at the rock surface is larger than the water flow from the surrounding saturated region of restricted permeability. We describe the methods with which such water desaturation processes in rock materials can be quantified. The water retention characteristic theta(psi) of crystalline rock samples was determined with a pressure membrane apparatus. The negative water potential, identical to the capillary pressure, psi, below the tensiometric range (psi < -0.1 MPa) can be measured with thermocouple psychrometers (TP), and the volumetric water contents, theta, by means of time domain reflectometry (TDR). These standard methods were adapted for measuring the water status in a macroscopically unfissured granodiorite with a total porosity of approximately 0.01. The measured water retention curve of granodiorite samples from the Grimsel test site (central Switzerland) exhibits a shape which is typical for bimodal pore size distributions. The measured bimodality is probably an artifact of a large surface ratio of solid/voids. The thermocouples were installed without a metallic screen using the cavity drilled into the granodiorite as a measuring chamber. The water potentials observed in a cylindrical granodiorite monolith ranged between -0.1 and -3.0 MPa; those near the wall in a ventilated tunnel between -0.1 and -2.2 MPa. Two types of three-rod TDR Probes were used, one as a depth probe inserted into the rock, the other as a surface probe using three copper stripes attached to the surface for detecting water content changes in the rock-to-air boundary. The TDR signal was smoothed with a low-pass filter, and the signal length determined based on the first derivative of the trace. Despite the low porosity of crystalline rock these standard methods are applicable to describe the unsaturated zone in solid rock and may also be used in other consolidated materials such as concrete.
Resumo:
La diabetes mellitus es una enfermedad que se caracteriza por la nula o insuficiente producción de insulina, o la resistencia del organismo a la misma. La insulina es una hormona que ayuda a que la glucosa llegue a los tejidos periféricos y al sistema nervioso para suministrar energía. Actualmente existen dos tipos de terapias aplicada en tejido subcutáneo: mediante inyección múltiple realizada con plumas, y la otra es mediante infusión continua de insulina por bomba (CSII). El mayor problema de esta terapia son los retardos por la absorción, tanto de los carbohidratos como de la insulina, y los retardos introducidos por el sensor subcutáneo de glucosa que mide la glucosa del líquido intersticial, lo deseable es controlar la glucosa en sangre. Para intentar independizar al paciente de su enfermedad se está trabajando en el desarrollo del páncreas endocrino artificial (PEA) que dotaría al paciente de una bomba de insulina, un sensor de glucosa y un controlador, el cual se encargaría de la toma de decisiones de las infusiones de insulina. Este proyecto persigue el diseño de un regulador en modo de funcionamiento en CL, con el objetivo de conseguir una regulación óptima del nivel de glucosa en sangre. El diseño de dicho regulador va a ser acometido utilizando la teoría del control por modelo interno (IMC). Esta teoría se basa en la idea de que es necesario realimentar la respuesta de un modelo aproximado del proceso que se quiere controlar. La salida del modelo, comparada con la del proceso real nos da la incertidumbre del modelo de la planta, frente a la planta real. Dado que según la teoría del modelo interno, estas diferencias se dan en las altas frecuencias, la teoría IMC propone un filtro paso bajo como regulador en serie con la inversa del modelo de la planta para conseguir el comportamiento deseado. Además se pretende implementar un Predictor Smith para minimizar los efectos del retardo de la medida del sensor. En el proyecto para conseguir la viabilidad del PEA se ha adaptado el controlador IMC clásico utilizando las ganancias estáticas de un modelo de glucosa, a partir de la ruta subcutánea de infusión y la vía subcutánea de medida. El modo de funcionamiento del controlador en SCL mejora el rango de normoglucemia, necesitando la intervención del paciente indicando anticipadamente el momento de las ingestas al controlador. El uso de un control SCL con el Predictor de Smith mejora los resultados pues se añade al controlador una variable sobre las ingestas con la participación del paciente. ABSTRACT. Diabetes mellitus is a group of metabolic diseases in which a person has high blood sugar, due to the body does not produce enough insulin, or because cells do not respond to the insulin produced. The insulin is a hormone that helps the glucose to reach to outlying tissues and the nervous system to supply energy. There are currently two types of therapies applied in subcutaneous tissue: the first one consists in using the intensive therapy with an insulin pen, and the other one is by continuous subcutaneous insulin infusion (CSII). The biggest problems of this therapy are the delays caused by the absorption of carbohydrates and insulin, and the delays introduced by the subcutaneous glucose sensor that measures glucose from interstitial fluid, it is suitable to control glucose blood. To try to improve these patients quality of life, work is being done on the development of an artificial endocrine pancreas (PEA) consisting of a subcutaneous insulin pump, a subcutaneous glucose sensor and an algorithm of glucose control, which would calculate the bolus that the pump would infuse to patient. This project aims to design a controller for closed-loop therapy, with the objective of obtain an optimal regulation of blood glucose level. The design of this controller will be formed using the theory of internal model control (IMC). This theory is based on the uncertainties given by a model to feedback the system control. Output model, in comparison with the actual process gives the uncertainty of the plant model, compared to the real plant. Since the theory of the internal model, these differences occur at high frequencies, the theory proposes IMC as a low pass filter regulator in series with the inverse model of the plant to get the required behavior. In addition, it will implement a Smith Predictor to minimize the effects of the delay measurement sensor. The project for the viability of PEA has adapted the classic IMC controller using the gains static of glucose model from the subcutaneous infusion and subcutaneous measuring. In simulation the SemiClosed-Loop controller get on the normoglycemia range, requiring patient intervention announce the bolus priming connected to intakes. Using an SCL control with the Smith Predictor improves the outcome because a variable about intakes is added to the controller through patient intervention.
Resumo:
The thesis will show how to equalise the effect of quantal noise across spatial frequencies by keeping the retinal flux (If-2) constant. In addition, quantal noise is used to study the effect of grating area and spatial frequency on contrast sensitivity resulting in the extension of the new contrast detection model describing the human contrast detection system as a simple image processor. According to the model the human contrast detection system comprises low-pass filtering due to ocular optics, addition of light dependent noise at the event of quantal absorption, high-pass filtering due to the neural visual pathways, addition of internal neural noise, after which detection takes place by a local matched filter, whose sampling efficiency decreases as grating area is increased. Furthermore, this work will demonstrate how to extract both the optical and neural modulation transfer functions of the human eye. The neural transfer function is found to be proportional to spatial frequency up to the local cut-off frequency at eccentricities of 0 - 37 deg across the visual field. The optical transfer function of the human eye is proposed to be more affected by the Stiles-Crawford -effect than generally assumed in the literature. Similarly, this work questions the prevailing ideas about the factors limiting peripheral vision by showing that peripheral optical acts as a low-pass filter in normal viewing conditions, and therefore the effect of peripheral optics is worse than generally assumed.
Resumo:
A range of physical and engineering systems exhibit an irregular complex dynamics featuring alternation of quiet and burst time intervals called the intermittency. The intermittent dynamics most popular in laser science is the on-off intermittency [1]. The on-off intermittency can be understood as a conversion of the noise in a system close to an instability threshold into effective time-dependent fluctuations which result in the alternation of stable and unstable periods. The on-off intermittency has been recently demonstrated in semiconductor, Erbium doped and Raman lasers [2-5]. Recently demonstrated random distributed feedback (random DFB) fiber laser has an irregular dynamics near the generation threshold [6,7]. Here we show the intermittency in the cascaded random DFB fiber laser. We study intensity fluctuations in a random DFB fiber laser based on nitrogen doped fiber. The laser generates first and second Stokes components 1120 nm and 1180 nm respectively under an appropriate pumping. We study the intermittency in the radiation of the second Stokes wave. The typical time trace near the generation threshold of the second Stokes wave (Pth) is shown at Fig. 1a. From the number of long enough time-traces we calculate statistical distribution between major spikes in time dynamics, Fig. 1b. To eliminate contribution of high frequency components of spikes we use a low pass filter along with the reference value of the output power. Experimental data is fitted by power law,
Resumo:
Synchronization plays an important role in telecommunication systems, integrated circuits, and automation systems. Formerly, the masterslave synchronization strategy was used in the great majority of cases due to its reliability and simplicity. Recently, with the wireless networks development, and with the increase of the operation frequency of integrated circuits, the decentralized clock distribution strategies are gaining importance. Consequently, fully connected clock distribution systems with nodes composed of phase-locked loops (PLLs) appear as a convenient engineering solution. In this work, the stability of the synchronous state of these networks is studied in two relevant situations: when the node filters are first-order lag-lead low-pass or when the node filters are second-order low-pass. For first-order filters, the synchronous state of the network shows to be stable for any number of nodes. For second-order filter, there is a superior limit for the number of nodes, depending on the PLL parameters. Copyright (C) 2009 Atila Madureira Bueno et al.
Resumo:
We compare the performance of two different low-storage filter diagonalisation (LSFD) strategies in the calculation of complex resonance energies of the HO2, radical. The first is carried out within a complex-symmetric Lanczos subspace representation [H. Zhang, S.C. Smith, Phys. Chem. Chem. Phys. 3 (2001) 2281]. The second involves harmonic inversion of a real autocorrelation function obtained via a damped Chebychev recursion [V.A. Mandelshtam, H.S. Taylor, J. Chem. Phys. 107 (1997) 6756]. We find that while the Chebychev approach has the advantage of utilizing real algebra in the time-consuming process of generating the vector recursion, the Lanczos, method (using complex vectors) requires fewer iterations, especially for low-energy part of the spectrum. The overall efficiency in calculating resonances for these two methods is comparable for this challenging system. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
A linearly tunable low-voltage CMOS transconductor featuring a new adaptative-bias mechanism that considerably improves the stability of the processed-signal common,mode voltage over the tuning range, critical for very-low voltage applications, is introduced. It embeds a feedback loop that holds input devices on triode region while boosting the output resistance. Analysis of the integrator frequency response gives an insight into the location of secondary poles and zeros as function of design parameters. A third-order low-pass Cauer filter employing the proposed transconductor was designed and integrated on a 0.8-mum n-well CMOS standard process. For a 1.8-V supply, filter characterization revealed f(p) = 0.93 MHz, f(s) = 1.82 MHz, A(min) = 44.08, dB, and A(max) = 0.64 dB at nominal tuning. Mined by a de voltage V-TUNE, the filter bandwidth was linearly adjusted at a rate of 11.48 kHz/mV over nearly one frequency decade. A maximum 13-mV deviation on the common-mode voltage at the filter output was measured over the interval 25 mV less than or equal to V-TUNE less than or equal to 200 mV. For V-out = 300 mV(pp) and V-TUNE = 100 mV, THD was -55.4 dB. Noise spectral density was 0.84 muV/Hz(1/2) @1 kHz and S/N = 41 dB @ V-out = 300 mV(pp) and 1-MHz bandwidth. Idle power consumption was 1.73 mW @V-TUNE = 100 mV. A tradeoff between dynamic range, bandwidth, power consumption, and chip area has then been achieved.
Resumo:
This paper describes a high senstivity low cost capacitive strain gage sensor. The theory, design, and sensor construction details are presented. It consists of eight capacitive sensors connected in two full bridges. The capacitive strain gage sensor structure was designed in order to produce high sensitivity and low dependence with temperature. By using a simple signal conditioning circuit constituted by a differential amplifier, a band-pass filter, and a precision rectifier the device can measure forces with resolution of 0.009 N and precision of 98.7%. It is rugged, presents linear response, and good repeatability. It presents sensitivity of 8.7 V/N and fall time of 12 ms.
Resumo:
This paper is on the use and performance of M-path polyphase Infinite Impulse Response (IIR) filters for channelisation, conventionally where Finite Impulse Response (FIR) filters are preferred. This paper specifically focuses on the Discrete Fourier Transform (DFT) modulated filter banks, which are known to be an efficient choice for channelisation in communication systems. In this paper, the low-pass prototype filter for the DFT filter bank has been implemented using an M-path polyphase IIR filter and we show that the spikes present at the stopband can be avoided by making use of the guardbands between narrowband channels. It will be shown that the channelisation performance will not be affected when polyphase IIR filters are employed instead of their counterparts derived from FIR prototype filters. Detailed complexity and performance analysis of the proposed use will be given in this article.
Resumo:
Amorphous SiC tandem heterostructures are used to filter a specific band, in the visible range. Experimental and simulated results are compared to validate the use of SiC multilayered structures in applications where gain compensation is needed or to attenuate unwanted wavelengths. Spectral response data acquired under different frequencies, optical wavelength control and side irradiations are analyzed. Transfer function characteristics are discussed. Color pulsed communication channels are transmitted together and the output signal analyzed under different background conditions. Results show that under controlled wavelength backgrounds, the device sensitivity is enhanced in a precise wavelength range and quenched in the others, tuning or suppressing a specific band. Depending on the background wavelength and irradiation side, the device acts either as a long-, a short-, or a band-rejection pass filter. An optoelectronic model supports the experimental results and gives insight on the physics of the device.
Resumo:
This work proposes a fully-digital interface circuit for the measurement of inductive sensors using a low-cost microcontroller (µC) and without any intermediate active circuit. Apart from the µC and the sensor, the circuit just requires an external resistor and a reference inductance so that two RL circuits with a high-pass filter (HPF) topology are formed. The µC appropriately excites such RL circuits in order to measure the discharging time of the voltage across each inductance (i.e. sensing and reference) and then it uses such discharging times to estimate the sensor inductance. Experimental tests using a commercial µC show a non-linearity error (NLE) lower than 0.5%FSS (Full-Scale Span) when measuring inductances from 1 mH to 10 mH, and from 10 mH to 100 mH.
Resumo:
The present study proposes to apply magnitude-squared coherence (MSC) to the somatosensory evoked potential for identifying the maximum driving response band. EEG signals, leads [Fpz'-Cz'] and [C3'-C4'], were collected from two groups of normal volunteers, stimulated at the rate of 4.91 (G1: 26 volunteers) and 5.13 Hz (G2: 18 volunteers). About 1400 stimuli were applied to the right tibial nerve at the motor threshold level. After applying the anti-aliasing filter, the signals were digitized and then further low-pass filtered (200 Hz, 6th order Butterworth and zero-phase). Based on the rejection of the null hypothesis of response absence (MSC(f) > 0.0060 with 500 epochs and the level of significance set at a = 0.05), the beta and gamma bands, 15-66 Hz, were identified as the maximum driving response band. Taking both leads together ("logical-OR detector", with a false-alarm rate of a = 0.05, and hence a = 0.0253 for each derivation), the detection exceeded 70% for all multiples of the stimulation frequency within this range. Similar performance was achieved for MSC of both leads but at 15, 25, 35, and 40 Hz. Moreover, the response was detected in [C3'-C4'] at 35.9 Hz and in [Fpz'-Cz'] at 46.2 Hz for all members of G2. Using the "logical-OR detector" procedure, the response was detected at the 7th multiple of the stimulation frequency for the series as a whole (considering both groups). Based on these findings, the MSC technique may be used for monitoring purposes.
Resumo:
Dye exclusion tests are used to determine the number of live and dead cells. These assays are based on the principle that intact plasma membranes in live cells exclude specific dyes, whereas dead cells do not. Although widely used, the trypan blue (TB) exclusion assay has limitations. The dye can be incorporated by live cells after a short exposure time, and personal reliability, related to the expertise of the analyst, can affect the results. We propose an alternative assay for evaluating cell viability that combines the TB exclusion test and the high sensitivity of the flow cytometry technique. Previous studies have demonstrated the ability of TB to emit fluorescence when complexed with proteins. According to our results, TB/bovine serum albumin and TB/cytoplasmic protein complexes emit fluorescence at 660 nm, which is detectable by flow cytometry using a 650-nm low-pass band filter. TB at 0.002% (w/v) was defined as the optimum concentration for distinguishing unstained living cells from fluorescent dead cells, and fluorescence emission was stable for 30 min after cell treatment. Although previous studies have shown that TB promotes green fluorescence quenching, TB at 0.002% did not interfere with green fluorescence in human live T-cells stained with anti-CD3/fluorescein isothiocyanate (FITC) monoclonal antibody. We observed a high correlation between the percentage of propidium iodide+CD3/FITC+ and TB+CD3/FITC+ cells, as well as similar double-stained cell profiles in flow cytometry dot-plot graphs. Taken together, the results indicate that a TB exclusion assay by flow cytometry can be employed as an alternative tool for quick and reliable cell viability analysis.
Resumo:
With continually increasing demands for improvements to atmospheric and planetary remote-sensing instrumentation, for both high optical system performance and extended operational lifetimes, an investigation to access the effects of prolonged exposure of the space environment to a series of infrared interference filters and optical materials was promoted on the NASA LDEF mission. The NASA Long Duration Exposure Facility (LDEF) was launchd by the Space Shuttle to transport various science and technology experiments both to and from space, providing investigators with the opportunity to study the effects of the space environment on materials and systems used in space-flight applications. Preliminary results to be discussed consist of transmission measurements obtained and processed from an infrared spectrophotometer both before (1983) and after (1990) exposure compared with unexposed control specimens, together with results of detailed microscopic and general visual examinations performed on the experiment. The principle lead telluride (PbTe) and Zinc Sulphide (ZnS) based multilayer filters selected for this preliminary investigation consist of : an 8-12µm low pass edge filter, a 10.6µm 2.5% half bandwidth (HBW) double half-wave narrow bandpass filter, and a 10% HBW triple half-wave wide bandpass filter at 15µm. Optical substrates of MgF2 and KRS-5 (T1BrI) will also be discussed.
Resumo:
Chebyshev optical-filter algorithms for low-cost microcomputers have been improved. An offset ripple is now used for better transmission/matching in low-pass stacks. A prototype for narrowband filters is now more general and nearer practicability.