984 resultados para Low processing temperature


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The performance of the 500 KHz planar-coil inductively coupled plasma source was studied. The global electrical characteristics of the discharge, distributions of the induced electromagnetic fields, plasma density, potential, and electron temperature were investigated. Achieved high plasma density and low electron temperature implied that the studied plasma source was promising for industrial applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background Little evidence is available about the association between temperature and cerebrovascular mortality in China. This study aims to examine the effects of ambient temperature on cerebrovascular mortality in different climatic zones in China. Method We obtained daily data on weather conditions, air pollution and cerebrovascular deaths from five cities (Beijing, Tianjin, Shanghai, Wuhan, and Guangzhou) in China during 2004-2008. We examined city-specific associations between ambient temperature and the cerebrovascular mortality, while adjusting for season, long-term trends, day of the week, relative humidity and air pollution. We examined cold effects using a 1°C decrease in temperature below a city-specific threshold, and hot effects using a 1°C increase in temperature above a city-specific threshold. We used a meta-analysis to summarize the cold and hot effects across the five cities. Results Beijing and Tianjin (with low mean temperature) had lower thresholds than Shanghai, Wuhan and Guangzhou (with high mean temperature). In Beijing, Tianjin, Wuhan and Guangzhou cold effects were delayed, while in Shanghai there was no or short induction. Hot effects were acute in all five cities. The cold effects lasted longer than hot effects. The hot effects were followed by mortality displacement. The pooled relative risk associated with a 1°C decrease in temperature below thresholds (cold effect) was 1.037 (95% confidence interval (CI): 1.020, 1.053). The pooled relative risk associated with a 1°C increase in temperature above thresholds (hot effect) was 1.014 (95% CI: 0.979, 1.050). Conclusion Cold temperatures are significantly associated with cerebrovascular mortality in China, while hot effect is not significant. People in colder climate cities were sensitive to hot temperatures, while people in warmer climate cities were vulnerable to cold temperature.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Studies on melt rheological properties of blends of low density polyethylene (LDPE) with selected grades of linear low density polyethylene (LLDPE), which differ widely in their melt flow indices, are reported, The data obtained in a capillary rheometer are presented to describe the effects of blend composition and shear rate on flow behavior index, melt viscosity, and melt elasticity. In general, blending of LLDPE I that has a low melt flow index (2 g/10 min) with LDPE results in a decrease of its melt viscosity, processing temperature, and the tendency of extrudate distortion, depending on blending ratio. A blending ratio around 20-30% LLDPE I seems optimum from the point of view of desirable improvement in processability behavior. On the other hand, blending of LLDPE II that has a high melt flow index (10 g/10 min) with LDPE offers a distinct advantage in increasing the pseudoplasticity of LDPE/LLDPE II blends.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Astaxanthin is a powerful antioxidant with various health benefits such as prevention of age-related macular degeneration and improvement of the immune system, liver and heart function. To improve the post-harvesting stability of astaxanthin used in food, feed and nutraceutical industries, the biomass of the high astaxanthin producing alga Haematococcus pluvialis was dried by spray- or freeze-drying and under vacuum or air at − 20 °C to 37 °C for 20 weeks. Freeze-drying led to 41 higher astaxanthin recovery compared to commonly-used spray-drying. Low storage temperature (− 20 °C, 4 °C) and vacuum-packing also showed higher astaxanthin stability with as little as 12.3 ± 3.1 degradation during 20 weeks of storage. Cost-benefit analysis showed that freeze-drying followed by vacuum-packed storage at − 20 °C can generate AUD600 higher profit compared to spray-drying from 100 kg H. pluvialis powder. Therefore, freeze-drying can be suggested as a mild and more profitable method for ensuring longer shelf life of astaxanthin from H. pluvialis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fe-doped tungsten oxide thin films with different concentrations (0 to 2.6 at%) were synthesized on glass and alumina substrates at room temperature using DC reactive sputtering and subsequently annealed at 300oC for 1 hour in air. The alumina substrate has pre-printed interdigitated Pt-electrodes for gas sensing measurements. The effects of Fe-doping on the film structure and morphology, electronic and optical properties for gas sensing were investigated. The grain size of the different films on the alumina and Pt regions of the substrate vary only slightly between 43-57 nm with median size of about 50 nm. Raman spectra showed that the integrated intensity of W=O to O–W–O bands increases with increasing Fe concentrations and this indicated an increase in the number of defects. From XPS the different concentrations of the Fe-doped films were 0.03 at%, 1.33 at% and 2.6 at%. All the films deposited on glass substrate have shown similar visible transmittance (about 70%) but the optical band gap of the pure film decreased form 3.30 eV to 3.15 eV after doping with 2.6 at% Fe. The Fe-doped WO3 film with the highest Fe concentration (2.6 at% Fe) has shown an enhanced gas sensing properties to NO2 at relatively lower operating temperature (150oC) and this can be attributed to the decrease in the optical band gap and an increase in the number of defects compared to the pure WO3 film.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ceramic matrix composites of Al2O3-SiC-(Al,Si) have been fabricated by directed melt oxidation of aluminum alloys into SiC particulate preforms. The proportions of Al2O3, alloy, and porosity in the composite can be controlled by proper selection of SLC particle size and the processing temperature. The wear resistance of composites was evaluated in pin-on-disk experiments against a hard steel substrate. Minimum wear rate comparable to conventional ceramics such as ZTA is recorded for the composition containing the highest fraction of alloy, owing to the development of a thin and adherent tribofilm with a low coefficient of friction.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Co(II)TPP(Py) complex was used as an efficient dioxygen carrier for the radical polymerization of 1,1-diphenylethylene (DPE), which has a low ceiling temperature, at ambient temperature and low oxygen pressure. The mechanism of polymerization is discussed' on the basis of kinetic data, W-vis, ESR, and H-1 NMR studies. The rate of polymerization (RP) and number-average molecular weights (M) of poly(1,1-diphenylethylene peroxide) (PDPEP) are higher and the polydispersity is lower than in 2,2'-azobis(isobutyronitrile) (AIBN) initiated polymerization. PDPEP was further. used as a macroinitiator for the polymerization of MMA. The polymerization obeys classical kinetics. The K-2 value of the PDPEP has been determined from the slope of R-P(2) VS [M](2)[I], which reveals that it can also be used at higher temperature for the polymerization. An "active" PMMA was also synthesized, containing initiating segments in the polymer backbone.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Long, laminar plasma jets at atmospheric pressure of pure argon and a mixture of argon and nitrogen with jet length up to 45 fi,Hes its diameter could be generated with a DC are torch by! restricting the movement of arc root in the torch channel. Effects of torch structure, gas feeding, and characteristics of power supply on the length of plasma jets were experimentally examined. Plasma jets of considerable length and excellent stability could be obtained by regulating the generating parameters, including are channel geometry gas flow I ate, and feeding methods, etc. Influence of flow turbulence at the torch,nozzle exit on the temperature distribution of plasma jets was numerically simulated. The analysis indicated that laminar flow plasma with very low initial turbulent kinetic energy will produce a long jet, with low axial temperature gradient. This kind of long laminar plasma jet could greatly improve the controllability for materials processing, compared with a short turbulent are let.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In selecting an excess temperature at which to operate a power plant cooling system it has been customary to consider only thermal stresses and to use the ratio of the number of organisms killed to the number of organisms entrained. This frequently leads to the selection of a low excess temperature, AT, which, in turn, requires a large volume flow of cooling water. When mortalities due to physical and chemical stresses are included and the total number of entrained organisms killed is taken as the measure of the environmental damage, it becomes evident that the choice of a low excess temperature is seldom, if ever, best.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Neste trabalho foi estudado o tratamento simultâneo por biofiltração de emissões de compostos orgânicos voláteis, COV e gás sulfídrico, H2S, em estações de tratamento de despejos industriais, de refinaria de petróleo, ETDI. A biofiltração dos gases emanados da EDTI mostrou ser uma técnica de alta eficiência, atingindo valores de 95 a 99 % para tratamento simultâneo de COV e H2S em concentrações de 1000 e 100 ppmv, respectivamente. Foram realizados testes em 95 dias consecutivos de operação, em uma planta piloto instalada na Superintendência da Industrialização do Xisto, SIX, em São Mateus do Sul, Paraná, de março a agosto de 2006. O biofiltro foi do tipo fluxo ascendente, com 3,77 m3 de leito orgânico, composto de turfa, carvão ativado, lascas de madeira, serragem brita fina além de outros componentes menores. Foi realizada inoculação biológica com lodo filtrado de estação de tratamento de esgoto sanitário. As vazões de gás aplicadas variaram de 85 a 407 m3/h, resultando em taxas de carga de massa de 11,86 a 193,03 g de COV/h.m3 de leito e tempos de residência de 24 segundos a 6,5 minutos, com tempo ótimo de 1,6 minutos. A capacidade máxima de remoção do sistema encontrada, nas condições testadas, foi de 15 g de COV/h. m3, compatível com os valores encontrados na literatura para depuração biológica de COV na escala praticada. Também foi verificada a redução de componentes específicos de BTX, demonstrando boa degradabilidade dos compostos orgânicos. Finalmente o biofiltro demonstrou boa robustez biológica diante dos desvios operacionais intencionalmente provocados, tais como falta de umidade do leito, baixa temperatura, alta vazão, falta de carga de COV e baixo pH do leito. Depois de retomada a condição de operação estável, a biofiltração rapidamente atingiu o estado de equilíbrio, assegurando o uso eficiente e confiável da técnica no tratamento de gases de EDTI na indústria do hidrocarbonetos ou em refinarias de petróleo.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effect of the growth temperature on the surface and interface quality for the GaN/AlN multiquantum well (MQW) layer grown by metal-organic vapour chemical deposition is investigated. The obtained GaN/AlN MQW structure is almost coherent to the underlying AlGaN layer at improved growth conditions. With a relatively low growth temperature, the GaN/AlN MQW growth rate increases, the surface roughness reduces considerably and no macro steps are observed, resulting in a better periodicity of MQW.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Mass Analyzed Low Energy Dual Ion Beam Epitaxy (MALE-DIBE) system has been designed and constructed in our laboratory. We believe that the system, which was installed and came into full operation in 1988, is the first facility of this kind. With our system we have carried out studies, for the first time, on compound synthesis of GaN and CoSi2 epitaxial thin films. RHEED and AES results show that GaN films, which were deposited on Si and sapphire substrates, are monocrystalline and of good stoichiometry. To our knowledge, GaN film heteroepitaxially grown on Si. which is more lattice-mismatched than GaN on sapphire, has not been reported before by other authors. RBS and TEM investigations indicated a rather good crystallinity of CoSi2 with a distinct interface between CoSi2 and the Si substrate. The channelling minimum yield chi(min) from the Co profile is approximately 4%. The results showed that the DIBE system with simultaneous arrival of two beams at the target is particularly useful in the formation of novel compounds at a relatively low substrate temperature.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A direct ion beam deposition system designed for heteroepitaxy at a low substrate temperature and for the growth of metastable compounds has been constructed and tested. The system consists of two mass-resolved low-energy ion beams which merge at the target with an incident energy range 50-25 000 eV. Each ion beam uses a Freeman ion source for ion production and a magnetic sector for mass filtering. While a magnetic quadrupole lens is used in one beam for ion optics, an electrostatic quadrupole lens focuses the other beam. Both focusing approaches provide a current density more than 100-mu-A/cm2, although the magnetic quadrupole gives a better performance for ion energies below 200 eV. The typical current of each beam reaches more than 0.3 mA at 100 eV, with a ribbon beam of about 0.3-0.5 x 2 cm2. The target is housed in an ultrahigh vacuum chamber with a base pressure of 1 x 10(-7) Pa and a typical pressure of 5 x 10(-6) Pa when a noncondensable beam like argon is brought into the chamber. During deposition, the target can be heated to 800-degrees-C and scanned mechanically with an electronic scanning control unit. The dual beam system has been used to grow GaN using a Ga+ and a N+ beam, and to study the oxygen and hydrogen ion beam bombardment effects during carbon ion beam deposition. The results showed that the simultaneous arrival of two beams at the target is particularly useful in compound formation and in elucidation of growth mechanisms.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The para-sexiphenyl (p-6P) monolayer film induces weak epitaxy growth (WEG) of disk-like organic semiconductors, and their charge mobilities are increased dramatically to the level of the corresponding single crystals [Wang et al., Adv. Mater. 2007, 19, 2168]. The growth behavior and morphology of p-6P monolayer film play decisive roles on WEG. Here, we investigated the growth behavior of p-6P submonolayer film as a function of the substrate temperature. Its growth exhibited two different mechanisms at high and low substrate temperature.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The harsh environment presented by engines, particularly in the exhaust systems, often necessitates the use of robust and therefore low bandwidth temperature sensors. Consequently, high frequencies are attenuated in the output. One technique for addressing this problem involves measuring the gas temperature using two sensors with different time-constants and mathematically reconstructing the true gas temperature from the resulting signals. Such a technique has been applied in gas turbine, rocket motor and combustion research. A new reconstruction technique based on difference equations has been developed and its effectiveness proven theoretically. The algorithms have been successfully tested and proven on experimental data from a rig that produces cyclic temperature variations. These tests highlighted that the separation of the thermocouple junctions must be very small to ensure that both sensors are subjected to the same gas temperatures. Exhaust gas temperatures were recorded by an array of thermocouples during transient operation of a high performance two-stroke engine. The results show that the increase in bandwidth arising from the dual sensor technique allowed accurate measurement of exhaust gas temperature with relatively robust thermocouples. Finally, an array of very fine thermocouples (12.5 - 50 microns) was used to measure the in-cycle temperature variation in the exhaust.