101 resultados para Loggers
Resumo:
We used Satellite Relay Data Loggers to obtain the first dive profiles for critically endangered leatherback turtles outside the nesting season. As individuals moved from the Caribbean out into the Atlantic, key aspects of their diving behaviour changed markedly, in line with theoretical predictions for how dive duration should vary with foraging success. In particular, in the Atlantic, where foraging success is expected to be higher, dives became much longer than in the Caribbean. The deepest-ever dive profile recorded for a reptile was obtained in the oceanic Atlantic, with a 54-min dive to 626 m on 26 August 2002. However, dives were typically much shallower (generally
Resumo:
Temperature loggers were attached to the carapace of green turtles (Chelonia mydas) at Ascension Island and Cyprus and to loggerhead turtles (Caretta caretta) at Cyprus, in order to record the ambient temperature experienced by individuals during the internesting interval, i.e. the period between consecutive clutches being laid. Internesting intervals were relatively short (10-14 days) and mean ambient temperatures relatively warm (27-28degreesC), compared to previous observations for these species nesting in Japan, although a single internesting interval versus temperature relationship described all the data for these two species from the different areas. The implication is that water temperature has both a common and a profound effect on the length of the internesting interval for these two species: internesting intervals are shorter when the water is warmer. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
For many decades it has been accepted that marine turtle hatchlings from the same nest generally emerge from the sand together. However, for loggerhead turtles (Caretta caretta) nesting on the Creek Island of Kefalonia, a more asynchronous pattern of emergence has been documented. By placing temperature loggers at the top and bottom of nests laid on Kefalonia during 1998, we examined whether this asynchronous emergence was related to the thermal conditions within nests. Pronounced thermal variation existed not only between, but also within, individual nests. These within-nest temperature differences were related to the patterns of hatchling emergence, with hatchlings from nests displaying large thermal ranges emerging over a longer time-scale than those characterised by more uniform temperatures. In many egg-laying animals, parental care of the offspring may continue while the eggs are incubating and also after they have hatched. Consequently, the importance of the nest site for determining incubation conditions may be reduced since the parents themselves may alter the local environment. By contrast, in marine turtles, parental care ceases once the eggs have been laid and the nest site covered. The positioning of the nest site, in both space and time, may therefore have profound effects for marine turtles by affecting, for example, the survival of the eggs and hatchlings as well as their sex (Janzen and Paukstis 1991).
Resumo:
Seabirds are central place foragers during the breeding season and, as marine food resources are often patchily distributed, flexibility in foraging behaviour may be important in maintaining prey delivery rates to chicks. We developed a methodological approach using a combination of GPS data loggers and temperature-depth recorders that allowed us to describe the behaviour of surface-feeding seabirds. Specifically, we tested whether differences in foraging behaviour of black-legged kittiwakes Rissa tridactyla could be linked with reproductive success by comparing 2 consecutive years at 2 sites. At Rathlin Island (Northern Ireland) during 2010, foraging differed markedly from that during 2009 and from that at Lambay Island (Republic of Ireland) during both years. Birds exhibited foraging trips of greater duration, travelled a greater total distance, spent more time in transit and spent longer recuperating on the surface of the water. This notable shift was associated with a decline in breeding success, with greater loss of eggs to predation and lower prey delivery rates, resulting in the starvation of 15 % of chicks. We suggest that food resources were reduced or geographically less accessible during 2010, with suitable foraging areas located further from the colony. Birds did not invest greater amounts of time attempting to catch prey. Thus, our results indicate that kittiwakes at Rathlin modulated their foraging behaviour not by increasing foraging effort through feeding more intensively within prey patches but by extending their range to increase the probability of encountering more profitable prey patches. © Inter-Research 2012.
Resumo:
Marine Protected Areas (MPAs) are an important conservation tool. For marine predators, recent research has focused on the use of Species Distribution Models (SDMs) to identify proposed sites. We used a maximum entropy modelling approach based on static and dynamic oceanographic parameters to determine optimal feeding habitat for black-legged kittiwakes (Rissa tridactyla) at two colonies during two consecutive breeding seasons (2009 and 2010). A combination of Geographic Positioning System (GPS) loggers and Time-Depth Recorders (TDRs) attributed feeding activity to specific locations. Feeding areas were <30 km from the colony, <40 km from land, in productive waters, 25–175m deep. The predicted extent of optimal habitat declined at both colonies between 2009 and 2010 coincident with declines in reproductive success. Whilst the area of predicted optimal habitat changed, its location was spatially stable between years. There was a close match between observed feeding locations and habitat predicted as optimal at one colony (Lambay Island, Republic of Ireland), but a notable mismatch at the other (Rathlin Island, Northern Ireland). Designation of an MPA at Rathlin may, therefore, be less effective than a similar designation at Lambay perhaps due to the inherent variability in currents and sea state in the North Channel compared to the comparatively stable conditions in the central Irish Sea. Current strategies for designating MPAs do not accommodate likely future redistribution of resources due to climate change. We advocate the development of new approaches including dynamic MPAs that track changes in optimal habitat and non-colony specific ecosystem management.
Resumo:
Predator–prey interactions are fundamental in the evolution and structure of ecological communities. Our understanding, however, of the strategies used in pursuit and evasion remains limited. Here, we report on the hunting dynamics of the world's fastest land animal, the cheetah, Acinonyx jubatus. Using miniaturized data loggers, we recorded fine-scale movement, speed and acceleration of free-ranging cheetahs to measure how hunting dynamics relate to chasing different sized prey. Cheetahs attained hunting speeds of up to 18.94 m s-1 and accelerated up to 7.5 m s-2 with greatest angular velocities achieved during the terminal phase of the hunt. The interplay between forward and lateral acceleration during chases showed that the total forces involved in speed changes and turning were approximately constant over time but varied with prey type. Thus, rather than a simple maximum speed chase, cheetahs first accelerate to decrease the distance to their prey, before reducing speed 5–8 s from the end of the hunt, so as to facilitate rapid turns to match prey escape tactics, varying the precise strategy according to prey species. Predator and prey thus pit a fine balance of speed against manoeuvring capability in a race for survival.
Resumo:
How animals manage time and expend energy has implications for survivorship. Being able to measure key metabolic costs of animals under natural conditions is therefore an important tool in behavioral ecology. One method for estimating activity-specific metabolic rate is via derived measures of acceleration, often 'overall dynamic body acceleration' (ODBA), recorded by an instrumented acceleration logger. ODBA has been shown to correlate well with rate of oxygen consumption (V ?o) in a range of species during activity in the laboratory. This study devised a method for attaching acceleration loggers to decapod crustaceans and then correlated ODBA against concurrent respirometry readings to assess accelerometry as a proxy for activity-specific energy expenditure in a model species, the American lobster Homarus americanus. Where the instrumented animals exhibited a sufficient range of activity levels, positive linear relationships were found between V ?o and ODBA over 20min periods at a range of ambient temperatures (6, 13 and 20°C). Mixed effect linear models based on these data and morphometrics provided reasonably strong predictive power for estimating activity-specific V ?o from ODBA. These V ?o-ODBA calibrations demonstrate the potential of accelerometry as an effective predictor of behavior-specific metabolic rate of crustaceans in the wild during periods of activity. © 2013 Elsevier Inc.
Resumo:
Acceleration data loggers can be used to construct time-energy budgets or identify specific behaviours in free living animals. Within a marine context such devices have been largely deployed on vertebrates with comparatively little attention paid to commercially important invertebrates such as cephalopod molluscs. Here we tested the utility of tri-axial accelerometers to tease apart six discrete behaviours in the common cuttlefish Sepia officinalis. By considering depth profiles in conjunction with body pitch and roll and overall dynamic body acceleration we were able to make distinctions between resting at the seabed, active swimming, mating, post-coital panting and active manoeuvring along the seabed. © 2012 Marine Biological Association of the United Kingdom.
Resumo:
Background
Product adherence is a pivotal issue in the development of effective vaginal microbicides to reduce sexual transmission of HIV. To date, the six Phase III studies of vaginal gel products have relied primarily on self-reporting of adherence. Accurate and reliable methods for monitoring user adherence to microbicide-releasing vaginal rings have yet to be established.
Methods
A silicone elastomer vaginal ring prototype containing an embedded, miniature temperature logger has been developed and tested in vitro and in cynomolgus macaques for its potential to continuously monitor environmental temperature and accurately determine episodes of ring insertion and removal.
Results
In vitro studies demonstrated that DST nano-T temperature loggers encapsulated in medical grade silicone elastomer were able to accurately and continuously measure environmental temperature. The devices responded quickly to temperature changes despite being embedded in different thickness of silicone elastomer. Prototype vaginal rings measured higher temperatures compared with a subcutaneously implanted device, showed high sensitivity to diurnal fluctuations in vaginal temperature, and accurately detected periods of ring removal when tested in macaques.
Conclusions
Vaginal rings containing embedded temperature loggers may be useful in the assessment of product adherence in late-stage clinical trials.
Resumo:
The popularity of tri-axial accelerometer data loggers to quantify animal activity through the analysis of signature traces is increasing. However, there is no consensus on how to process the large data sets that these devices generate when recording at the necessary high sample rates. In addition, there have been few attempts to validate accelerometer traces with specific behaviours in non-domesticated terrestrial mammals.
Resumo:
Facilities managers have a host of skills to sustain the functionality of complex buildings, often not provided by them directly, but by the team of specialists they draw upon to effectively plan for the future, whether the resource be money, space or technology. Building intelligence presents a challenge in terms of understanding a wholly new approach to the building management. This paper asks if the intelligent building of today meets the needs of the facilities management team. Does it enable them to manage their asset more effectively? New technologies are converging that will enable a radically new approach to maintenance, enabling remote smart sensing or remote condition based monitoring (CBM). Some of the design and economic issues that arise from this radically new approach to managing built assets are highlighted and the possibilities for a maintenance environment, where wires, power cables and data loggers become a thing of the past, is described.
Resumo:
The collection of wind speed time series by means of digital data loggers occurs in many domains, including civil engineering, environmental sciences and wind turbine technology. Since averaging intervals are often significantly larger than typical system time scales, the information lost has to be recovered in order to reconstruct the true dynamics of the system. In the present work we present a simple algorithm capable of generating a real-time wind speed time series from data logger records containing the average, maximum, and minimum values of the wind speed in a fixed interval, as well as the standard deviation. The signal is generated from a generalized random Fourier series. The spectrum can be matched to any desired theoretical or measured frequency distribution. Extreme values are specified through a postprocessing step based on the concept of constrained simulation. Applications of the algorithm to 10-min wind speed records logged at a test site at 60 m height above the ground show that the recorded 10-min values can be reproduced by the simulated time series to a high degree of accuracy.
Resumo:
Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.
Resumo:
As condições de ambiente térmico e aéreo, no interior de instalações para animais, alteram-se durante o dia, devido à influência do ambiente externo. Para que análises estatísticas e geoestatísticas sejam representativas, uma grande quantidade de pontos distribuídos espacialmente na área da instalação deve ser monitorada. Este trabalho propõe que a variação no tempo das variáveis ambientais de interesse para a produção animal, monitoradas no interior de instalações para animais, pode ser modelada com precisão a partir de registros discretos no tempo. O objetivo deste trabalho foi desenvolver um método numérico para corrigir as variações temporais dessas variáveis ambientais, transformando os dados para que tais observações independam do tempo gasto durante a aferição. O método proposto aproximou os valores registrados com retardos de tempo aos esperados no exato momento de interesse, caso os dados fossem medidos simultaneamente neste momento em todos os pontos distribuídos espacialmente. O modelo de correção numérica para variáveis ambientais foi validado para o parâmetro ambiental temperatura do ar, sendo que os valores corrigidos pelo método não diferiram pelo teste Tukey, a 5% de probabilidade dos valores reais registrados por meio de dataloggers.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)