952 resultados para Localização de falhas (Engenharia)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The performance of algorithms for fault location i n transmission lines is directly related to the accuracy of its input data. Thus, fa ctors such as errors in the line parameters, failures in synchronization of oscillographic recor ds and errors in measurements of voltage and current can significantly influence the accurac y of algorithms that use bad data to indicate the fault location. This work presents a new method ology for fault location in transmission lines based on the theory of state estimation in or der to determine the location of faults more accurately by considering realistic systematic erro rs that may be present in measurements of voltage and current. The methodology was implemente d in two stages: pre-fault and post- fault. In the first step, assuming non-synchronized data, the synchronization angle and positive sequence line parameters are estimated, an d in the second, the fault distance is estimated. Besides calculating the most likely faul t distance obtained from measurement errors, the variance associated with the distance f ound is also determined, using the errors theory. This is one of the main contributions of th is work, since, with the proposed algorithm, it is possible to determine a most likely zone of f ault incidence, with approximately 95,45% of confidence. Tests for evaluation and validation of the proposed algorithm were realized from actual records of faults and from simulations of fictitious transmission systems using ATP software. The obtained results are relevant to show that the proposed estimation approach works even adopting realistic variances, c ompatible with real equipments errors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

With the heavy use of bearings in various segments of the industry, there are a large number of necessary interruptions in industrial processes to perform maintenance on these devices, with the case study wind turbines. The growth of the wind energy sector, encouraged to conduct research that helps to solve this problem. To contribute to predictive maintenance has been carried out a signal analysis using techniques which allow detection and location of the problem in order to prevent accidents caused and losses due to unexpected equipment failures, whereas low system rotation complicates the detection of the failure. To work around this problem, there was the indication of standard signals for defects in the bearings, making diagnosis of possible failures. With this diagnosis can be performed predictive maintenance, identifying the failure of the system that were tested, such as the introduction of grains of sand in the bearing, wear on the outer race of the bearing and bearing rust. By processing signals it is possible to construct graphs developing a mapping of defects by different peaks in the frequency band.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nesta dissertação são analisados métodos de localização baseados na rede, com destaque para os métodos de correlação de assinaturas de rádio-frequência (DCM - Database Correlation Methods). Métodos baseados na rede não requerem modificações nos terminais móveis (MS - Mobile Stations), sendo portanto capazes de estimar a localização de MS legados, i.e., sem suporte específico a posicionamento. Esta característica, associada a alta disponibilidade e precisão dos métodos DCM, torna-os candidatos viáveis para diversas aplicações baseadas em posição, e em particular para a localização de chamadas para números de emergência - polícia, defesa civil, corpo de bombeiros, etc. - originadas de telefones móveis celulares. Duas técnicas para diminuição do tempo médio para produção de uma estimativa de posição são formuladas: a filtragem determinística e a busca otimizada utilizando algoritmos genéticos. Uma modificação é realizada nas funções de avaliação utilizadas em métodos DCM, inserindo um fator representando a inacurácia intrínseca às medidas de nível de sinal realizadas pelos MS. As modificações propostas são avaliadas experimentalmente em redes de telefonia móvel celular de segunda e terceira gerações em ambientes urbanos e suburbanos, assim como em redes locais sem fio em ambiente indoor. A viabilidade da utilização de bancos de dados de correlação (CDB - Correlation Database) construídos a partir de modelagem de propagação é analisada, bem como o efeito da calibração de modelos de propagação empíricos na precisão de métodos DCM. Um dos métodos DCM propostos, utilizando um CDB calibrado, teve um desempenho superior ao de vários outros métodos DCM publicados na literatura, atingindo em área urbana a precisão exigida dos métodos baseados na rede pela regulamentação FCC (Federal Communications Commission) para o serviço E911 (Enhanced 911 ).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste trabalho é contribuir com o desenvolvimento de uma técnica baseada em sistemas inteligentes que possibilite a localização exata ou aproximada do ponto de origem de uma Variação de Tensão de Curta Duração (VTCD) (gerada por uma falta) em um sistema de distribuição de energia elétrica. Este trabalho utiliza um Phase-Locked Loop (PLL) com o intuito de detectar as faltas. Uma vez que a falta é detectada, os sinais de tensão obtidos durante a falta são decompostos em componentes simétricas instantâneas por meio do método proposto. Em seguida, as energias das componentes simétricas são calculadas e utilizadas para estimar a localização da falta. Nesta pesquisa, são avaliadas duas estruturas baseadas em Redes Neurais Artificiais (RNAs). A primeira é projetada para classificar a localização da falta em um dos pontos possíveis e a segunda é projetada para estimar a distância da falta ao alimentador. A técnica aqui proposta aplica-se a alimentadores trifásicos com cargas equilibradas. No desenvolvimento da mesma, considera-se que há disponibilidade de medições de tensões no nó inicial do alimentador e também em pontos esparsos ao longo da rede de distribuição. O banco de dados empregado foi obtido através de simulações de um modelo de alimentador radial usando o programa PSCAD/EMTDC. Testes de sensibilidade empregando validação-cruzada são realizados em ambas as arquiteturas de redes neurais com o intuito de verificar a confiabilidade dos resultados obtidos. Adicionalmente foram realizados testes com faltas não inicialmente contidas no banco de dados a fim de se verificar a capacidade de generalização das redes. Os desempenhos de ambas as arquiteturas de redes neurais foram satisfatórios e demonstram a viabilidade das técnicas propostas para realizar a localização de faltas em redes de distribuição.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The expectations of citizens from the Information Technologies (ITs) are increasing as the ITs have become integral part of our society, serving all kinds of activities whether professional, leisure, safety-critical applications or business. Hence, the limitations of the traditional network designs to provide innovative and enhanced services and applications motivated a consensus to integrate all services over packet switching infrastructures, using the Internet Protocol, so as to leverage flexible control and economical benefits in the Next Generation Networks (NGNs). However, the Internet is not capable of treating services differently while each service has its own requirements (e.g., Quality of Service - QoS). Therefore, the need for more evolved forms of communications has driven to radical changes of architectural and layering designs which demand appropriate solutions for service admission and network resources control. This Thesis addresses QoS and network control issues, aiming to improve overall control performance in current and future networks which classify services into classes. The Thesis is divided into three parts. In the first part, we propose two resource over-reservation algorithms, a Class-based bandwidth Over-Reservation (COR) and an Enhanced COR (ECOR). The over-reservation means reserving more bandwidth than a Class of Service (CoS) needs, so the QoS reservation signalling rate is reduced. COR and ECOR allow for dynamically defining over-reservation parameters for CoSs based on network interfaces resource conditions; they aim to reduce QoS signalling and related overhead without incurring CoS starvation or waste of bandwidth. ECOR differs from COR by allowing for optimizing control overhead minimization. Further, we propose a centralized control mechanism called Advanced Centralization Architecture (ACA), that uses a single state-full Control Decision Point (CDP) which maintains a good view of its underlying network topology and the related links resource statistics on real-time basis to control the overall network. It is very important to mention that, in this Thesis, we use multicast trees as the basis for session transport, not only for group communication purposes, but mainly to pin packets of a session mapped to a tree to follow the desired tree. Our simulation results prove a drastic reduction of QoS control signalling and the related overhead without QoS violation or waste of resources. Besides, we provide a generic-purpose analytical model to assess the impact of various parameters (e.g., link capacity, session dynamics, etc.) that generally challenge resource overprovisioning control. In the second part of this Thesis, we propose a decentralization control mechanism called Advanced Class-based resource OverpRovisioning (ACOR), that aims to achieve better scalability than the ACA approach. ACOR enables multiple CDPs, distributed at network edge, to cooperate and exchange appropriate control data (e.g., trees and bandwidth usage information) such that each CDP is able to maintain a good knowledge of the network topology and the related links resource statistics on real-time basis. From scalability perspective, ACOR cooperation is selective, meaning that control information is exchanged dynamically among only the CDPs which are concerned (correlated). Moreover, the synchronization is carried out through our proposed concept of Virtual Over-Provisioned Resource (VOPR), which is a share of over-reservations of each interface to each tree that uses the interface. Thus, each CDP can process several session requests over a tree without requiring synchronization between the correlated CDPs as long as the VOPR of the tree is not exhausted. Analytical and simulation results demonstrate that aggregate over-reservation control in decentralized scenarios keep low signalling without QoS violations or waste of resources. We also introduced a control signalling protocol called ACOR Protocol (ACOR-P) to support the centralization and decentralization designs in this Thesis. Further, we propose an Extended ACOR (E-ACOR) which aggregates the VOPR of all trees that originate at the same CDP, and more session requests can be processed without synchronization when compared with ACOR. In addition, E-ACOR introduces a mechanism to efficiently track network congestion information to prevent unnecessary synchronization during congestion time when VOPRs would exhaust upon every session request. The performance evaluation through analytical and simulation results proves the superiority of E-ACOR in minimizing overall control signalling overhead while keeping all advantages of ACOR, that is, without incurring QoS violations or waste of resources. The last part of this Thesis includes the Survivable ACOR (SACOR) proposal to support stable operations of the QoS and network control mechanisms in case of failures and recoveries (e.g., of links and nodes). The performance results show flexible survivability characterized by fast convergence time and differentiation of traffic re-routing under efficient resource utilization i.e. without wasting bandwidth. In summary, the QoS and architectural control mechanisms proposed in this Thesis provide efficient and scalable support for network control key sub-systems (e.g., QoS and resource control, traffic engineering, multicasting, etc.), and thus allow for optimizing network overall control performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de doutoramento, Informática (Engenharia Informática), Universidade de Lisboa, Faculdade de Ciências, 2015

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica Ramo de Manutenção e Produção

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Eletrotécnica e de Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores