961 resultados para LEACH Mobile Enhanced protocol
Resumo:
In this paper, we propose an original method to geoposition an audio/video stream with multiple emitters that are at the same time receivers of the mixed signal. The obtained method is suitable when a list of positions within a known area is encoded with precision tailored to the visualization capabilities of the target device. Nevertheless, it is easily adaptable to new precision requirements, as well as parameterized data precision. This method extends a previously proposed protocol, without incurring in any performance penalty.
Resumo:
Porosity development of mesostructured colloidal silica nanoparticles is related to the removal of the organic templates and co-templates which is often carried out by calcination at high temperatures, 500-600 °C. In this study a mild detemplation method based on the oxidative Fenton chemistry has been investigated. The Fenton reaction involves the generation of OH radicals following a redox Fe3+/Fe2+ cycle that is used as catalyst and H2O2 as oxidant source. Improved material properties are anticipated since the Fenton chemistry comprises milder conditions than calcination. However, the general application of this methodology is not straightforward due to limitations in the hydrothermal stability of the particular system under study. The objective of this work is three-fold: 1) reducing the residual Fe in the resulting solid as this can be detrimental for the application of the material, 2) shortening the reaction time by optimizing the reaction temperature to minimize possible particle agglomeration, and finally 3) investigating the structural and textural properties of the resulting material in comparison to the calcined counterparts. It appears that the Fenton detemplation can be optimized by shortening the reaction time significantly at low Fe concentration. The milder conditions of detemplation give rise to enhanced properties in terms of surface area, pore volume, structural preservation, low Fe residue and high degree of surface hydroxylation; the colloidal particles are stable during storage. A relative particle size increase, expressed as 0.11%·h-1, has been determined.
Resumo:
Patients’ bowel dysfunction is a major factor that weakens the results of surgical care as it can cause pain and weaken patients’ rehabilitation. Bowel dysfunction is a common postoperative problem, yet most incidents remain undocumented. The nursing profession has a significant role in enhancing the bowel function postoperatively. However, studies of postoperative bowel function after hepatectomy are scarce and somewhat incongruous. Enhanced recovery protocols are innovative models of care aiming for better outcomes of surgical care. Enhanced recovery protocols can improve gastrointestinal function after surgery, yet patients are also known to be satisfied with their care. The aim was to investigate if postoperative bowel function day varies between patients in terms of age, gender, ASA score, type of surgery, histology, patients’ experienced pain and experienced satisfaction three days after discharge and three months after operation in patients undergoing hepatectomy. The goal was to produce information for basis of scientific research, to give nurses in clinical setting more tools to work with hepatectomy patients undergoing enhanced recovery protocol and to produce information to nurse managers to use in process management of patients undergoing enhanced recovery protocol. The design of this study is descriptive. Data was collected retrospectively from hepatectomy patients (n = 134) undergoing enhanced recovery protocol within the first year of enhanced recovery protocol implementation. The data was based on registers and analyzed statistically. Mean age of patients was 62 years and mean day of discharge was 4. Main (n = 72) histology of the patients was colorectal liver metastases. Mean bowel function day was 3. Most of the patients were very satisfied or satisfied with the care three days after discharge (99%) and three months (90%) after operation. Most of the patients (72%) experienced moderate pain three days after discharge, but three months after operation 47% of the patients did not experience pain and 48% experienced moderate pain. There were no statistically significant differences in bowel function between different age groups, genders, ASA score groups or histologies. Neither were there statistically significant differences in postoperative bowel function in terms of experienced satisfaction or pain. There were statistically significant differences in postoperative bowel function between different types of surgery (p < 0.01). Nurses should take into consideration hepatectomy patients’ type of surgery and pay special attention in supporting major open hepatectomy patients’ postoperative bowel function. Nurses should educate patients undergoing major open hepatectomy about prolonged postoperative bowel function.
Resumo:
Introdução: A cintigrafia óssea é um dos exames mais frequentes em Medicina Nuclear. Esta modalidade de imagem médica requere um balanço apropriado entre a qualidade de imagem e a dose de radiação, ou seja, as imagens obtidas devem conter o número mínimo de contagem necessárias, para que apresentem qualidade considerada suficiente para fins diagnósticos. Objetivo: Este estudo tem como principal objetivo, a aplicação do software Enhanced Planar Processing (EPP), nos exames de cintigrafia óssea em doentes com carcinoma da mama e próstata que apresentam metástases ósseas. Desta forma, pretende-se avaliar a performance do algoritmo EPP na prática clínica em termos de qualidade e confiança diagnóstica quando o tempo de aquisição é reduzido em 50%. Material e Métodos: Esta investigação teve lugar no departamento de Radiologia e Medicina Nuclear do Radboud University Nijmegen Medical Centre. Cinquenta e um doentes com suspeita de metástases ósseas foram administrados com 500MBq de metilenodifosfonato marcado com tecnécio-99m. Cada doente foi submetido a duas aquisições de imagem, sendo que na primeira foi seguido o protocolo standard do departamento (scan speed=8 cm/min) e na segunda, o tempo de aquisição foi reduzido para metade (scan speed=16 cm/min). As imagens adquiridas com o segundo protocolo foram processadas com o algoritmo EPP. Todas as imagens foram submetidas a uma avaliação objetiva e subjetiva. Relativamente à análise subjetiva, três médicos especialistas em Medicina Nuclear avaliaram as imagens em termos da detetabilidade das lesões, qualidade de imagem, aceitabilidade diagnóstica, localização das lesões e confiança diagnóstica. No que respeita à avaliação objetiva, foram selecionadas duas regiões de interesse, uma localizada no terço médio do fémur e outra localizada nos tecidos moles adjacentes, de modo a obter os valores de relação sinal-ruído, relação contraste-ruído e coeficiente de variação. Resultados: Os resultados obtidos evidenciam que as imagens processadas com o software EPP oferecem aos médicos suficiente informação diagnóstica na deteção de metástases, uma vez que não foram encontradas diferenças estatisticamente significativas (p>0.05). Para além disso, a concordância entre os observadores, comparando essas imagens e as imagens adquiridas com o protocolo standard foi de 95% (k=0.88). Por outro lado, no que respeita à qualidade de imagem, foram encontradas diferenças estatisticamente significativas quando se compararam as modalidades de imagem entre si (p≤0.05). Relativamente à aceitabilidade diagnóstica, não foram encontradas diferenças estatisticamente significativas entre as imagens adquiridas com o protocolo standard e as imagens processadas com o EPP software (p>0.05), verificando-se uma concordância entre os observadores de 70.6%. Todavia, foram encontradas diferenças estatisticamente significativas entre as imagens adquiridas com o protocolo standard e as imagens adquiridas com o segundo protocolo e não processadas com o software EPP (p≤0.05). Para além disso, não foram encontradas diferenças estatisticamente significativas (p>0.05) em termos de relação sinal-ruído, relação contraste-ruído e coeficiente de variação entre as imagens adquiridas com o protocolo standard e as imagens processadas com o EPP. Conclusão: Com os resultados obtidos através deste estudo, é possível concluir que o algoritmo EPP, desenvolvido pela Siemens, oferece a possibilidade de reduzir o tempo de aquisição em 50%, mantendo ao mesmo tempo uma qualidade de imagem considerada suficiente para fins de diagnóstico. A utilização desta tecnologia, para além de aumentar a satisfação por parte dos doentes, é bastante vantajosa no que respeita ao workflow do departamento.
Resumo:
OBJECTIVES To evaluate the initial results of a prostate cancer screening program using mobile units in Brazil. METHODS Since 2004, we have conducted a program of prostate cancer screening using mobile units across 231 municipalities from 6 Brazilian states. RESULTS A total of 17 571 men were evaluated by clinical history, digital rectal examination (DRE), and serum free and total prostate-specific antigen (PSA) levels. The recommendations for biopsy were a PSA level of >= 4.0 ng/mL, DRE findings suspicious for cancer, or a PSA level of 2.5-4.0 ng/mL with a percent-free PSA level <15%. The biopsy protocol included 12 biopsy cores from the peripheral zone, 2 from the transition zone, and additional sampling of suspicious areas. The cumulative cancer detection rate was 3.7%. The main indication for biopsy was a PSA level of >= 4.0 ng/mL (51.2%), with a positive predictive value (PPV) of 44.1%. Another 19.7% of biopsied men had suspicious DRE findings with a normal PSA level (PPV 23.5%). A percent-free PSA level of <15% in men with a PSA level of 2.5-4.0 ng/mL and normal DRE findings yielded a PPV of 31.1%. The PPV was greater (70.9%) for the 7.1% of men with both suspicious DRE findings and a PSA level of >4.0 ng/mL. Most cancers were Stage T1-T2 (93.4%), and the percentage of Gleason score of >= 7 was 32.5%. The proportion of insignificant cancers according to Epstein`s criteria was 13.5%. CONCLUSIONS A mobile prostate cancer screening unit enabled an underserved population to gain access to specialized care through the public healthcare system. The cancer detection rate in this population was similar to those from international studies. UROLOGY 76: 1052-1057, 2010. (C) 2010 Published by Elsevier Inc.
Resumo:
A 41-year-old man with cleft palate presented with a wide dehiscence and missing teeth. Six implants had been placed for fabrication of an overdenture, which was unsatisfactory. A bar was waxed and cast for connection to the implants; precision attachments were placed laterally for retention. A fixed partial denture was fabricated, and milled crowns were fabricated at the molar region to provide a guiding plane for insertion of a removable palatal obturator. Good swallowing and speech outcomes were achieved. This technique provided functional and esthetic benefits, enhanced oral hygiene, and improved the psychological condition of the patient.
Resumo:
The growth of direct marketing has been attributed to rapid advances in technology and the changing market context. The fundamental ability of direct marketers to communicate with consumers and to elicit a response, combined with the ubiquitous nature and power of mobile digital technology, provides a synergy that will increase the potential for the success of direct marketing. The aim of this paper is to provide an analytical framework identifying the developments in the digital environment from e-marketing to m-marketing, and to alert direct marketers to the enhanced capabilities available to them.
Resumo:
Conferência - 16th International Symposium on Wireless Personal Multimedia Communications (WPMC)- Jun 24-27, 2013
Resumo:
Future industrial control/multimedia applications will increasingly impose or benefit from wireless and mobile communications. Therefore, there is an enormous eagerness for extending currently available industrial communications networks with wireless and mobility capabilities. The RFieldbus European project is just one example, where a PROFIBUS-based hybrid (wired/wireless) architecture was specified and implemented. In the RFieldbus architecture, interoperability between wired and wireless components is achieved by the use specific intermediate networking systems operating at the physical layer level, i.e. operating as repeaters. Instead, in this paper we will focus on a bridge-based approach, which presents several advantages. This concept was introduced in (Ferreira, et al., 2002), where a bridge-based approach was briefly outlined. Then, a specific Inter-Domain Protocol (IDP) was proposed to handle the Inter-Domain transactions in such a bridge-based approach (Ferreira, et al., 2003a). The major contribution of this paper is in extending these previous works by describing the protocol extensions to support inter-cell mobility in such a bridge-based hybrid wired/wireless PROFIBUS networks.
Resumo:
The IEEE 802.15.4/ZigBee protocols are gaining increasing interests in both research and industrial communities as candidate technologies for Wireless Sensor Network (WSN) applications. In this paper, we present an open-source implementation of the IEEE 802.15.4/Zigbee protocol stack under the TinyOS operating system for the MICAz motes. This work has been driven by the need for an open-source implementation of the IEEE 802.15.4/ZigBee protocols, filling a gap between some newly released complex C implementations and black-box implementations from different manufacturers. In addition, we share our experience on the challenging problem that we have faced during the implementation of the protocol stack on the MICAz motes. We strongly believe that this open-source implementation will potentiate research works on the IEEE 802.15.4/Zigbee protocols allowing their demonstration and validation through experimentation.
Resumo:
This paper describes how to extend the access to remote experiments from mobile devices, aiming to better engage digital native students who expect a more interactive and ubiquitous access mode. The extension is based on features of HTML5 and the jQuery Mobile framework, which allow accessing the experiments from different operating systems via the browser or native applications. As a result, users have a richer interaction mode with the experiments, which includes access from simple hand-held devices such as smartphones and PDAs. Extending the access to remote experiments, from simple devices, enables its use in other educational stages, such as high schools, where teachers struggle to engage students in STEM learning. By enabling students to use their everyday "technological companions", e.g. cellular phones, to access remote experiments, we seek to increase the educational value of this technology-enhanced learning resource.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
In this paper a new method for self-localization of mobile robots, based on a PCA positioning sensor to operate in unstructured environments, is proposed and experimentally validated. The proposed PCA extension is able to perform the eigenvectors computation from a set of signals corrupted by missing data. The sensor package considered in this work contains a 2D depth sensor pointed upwards to the ceiling, providing depth images with missing data. The positioning sensor obtained is then integrated in a Linear Parameter Varying mobile robot model to obtain a self-localization system, based on linear Kalman filters, with globally stable position error estimates. A study consisting in adding synthetic random corrupted data to the captured depth images revealed that this extended PCA technique is able to reconstruct the signals, with improved accuracy. The self-localization system obtained is assessed in unstructured environments and the methodologies are validated even in the case of varying illumination conditions.