970 resultados para Knee-joint angle
Resumo:
OBJECTIVES: To determine clinical and ultrasonographic predictors of joint replacement surgery across Europe in primary osteoarthritis (OA) of the knee. METHODS: This was a 3-year prospective study of a painful OA knee cohort (from a EULAR-sponsored, multicentre study). All subjects had clinical evaluation, radiographs and ultrasonography (US) at study entry. The rate of knee replacement surgery over the 3-year follow-up period was determined using Kaplan-Meier survival data analyses. Predictive factors for joint replacement were identified by univariate log-rank test then multivariate analysis using a Cox proportional-hazards regression model. Potential baseline predictors included demographic, clinical, radiographic and US features. RESULTS: Of the 600 original patients, 531 (88.5%), mean age 67+/-10 years, mean disease duration 6.1+/-6.9 years, had follow-up data and were analysed. During follow-up (median 3 years; range 0-4 years), knee replacement was done or required for 94 patients (estimated event rate of 17.7%). In the multivariate analysis, predictors of joint replacement were as follows: Kellgren and Lawrence radiographic grade (grade > or =III vs <III, hazards ratio (HR) = 4.08 (95% CI 2.34 to 7.12), p<0.0001); ultrasonographic knee effusion (> or =4 mm vs <4 mm) (HR = 2.63 (95% CI 1.70 to 4.06), p<0.0001); knee pain intensity on a 0-100 mm visual analogue scale (> or =60 vs <60) (HR = 1.81 (95% CI 1.15 to 2.83), p=0.01) and disease duration (> or =5 years vs <5 years) (HR=1.63 (95% CI 1.08 to 2.47), p=0.02). Clinically detected effusion and US synovitis were not associated with joint replacement in the univariate analysis. CONCLUSION: Longitudinal evaluation of this OA cohort demonstrated significant progression to joint replacement. In addition to severity of radiographic damage and pain, US-detected effusion was a predictor of subsequent joint replacement.
Resumo:
Introduction: The posterior inclination of the tibial component is an important factor that can affect the success of total knee arthroplasty. It can reduce the posterior impingement and thus increase the range of flexion, but it may also induce instability in flexion, anterior impingement between the polyethylene of postero-stabilizing knee prosthesis, and anterior conflict with the cortical bone and the stem. Although the problem is identified, there is still a debate on the ideal inclination angle and the surgical technique to avoid an excessive posterior inclination. The aim of this study was to predict the effect of a posterior inclination of the tibial component on the contact pattern on the tibial insert, using a numerical musculoskeletal model of the knee joint. Methods: A 3D finite element model of the knee joint was developed to simulate an active and loaded squat movement after total knee arthroplasty. Flexion was actively controlled by the quadriceps muscle and muscle activations were estimated from EMG data and were synchronized by a feedback algorithm. Two inclinations of the tibial tray were considered: a posterior inclination of 0° or 10°. During the entire range of flexion, the following quantities were calculated: the tibiofemoral and patello-femoral contact force, and the contact pattern on polyethylene insert. The antero-posterior displacement of the contact pattern was also measured. Abaqus 6.7 was used for all analyses. Results: The tibio-femoral and patello-femoral contact forces increased during flexion and reached respectively 4 and 7 BW (bodyweight) at 90° of flexion. They were slightly affected by the inclination of the tibial tray. Without posterior inclination, the contact pattern on the tibial insert remained centered. The contact pressure was lower than 5 MPa below 60° of flexion, but exceeded 20 MPa at 90° of flexion. The posterior inclination displaced the contact point posteriorly by 2 to 4 mm. Conclusion: The inclination of the tibial tray displaced the contactpattern towards the posterior border of the tibial insert. However, even for 10° of inclination, the contact center remained far from the posterior border (12 mm). There was no instability predicted for this movement.
Resumo:
Accurate measurement of knee kinematics during functional activities suffers mainly from soft tissue artifact (STA): the combination of local surface deformations and rigid movement of markers relative to the underlying bone (also called rigid STA movement: RSTAM). This study proposes to assess RSTAM on the thigh, shank, and knee joint and to observe possible features between subjects. Nineteen subjects with knee arthroplasty were asked to walk on a treadmill while a biplane fluoroscopic system (X-rays) and a stereophotogrammetric system (skin markers) recorded their knee movement. The RSTAM was defined as the rigid movement of the cluster of skin markers relative to the prosthesis. The results showed that RSTAM amplitude represents approximately 80-100% of the STA. The vertical axis of the anatomical frame of the femur was influenced the most by RSTAM. Combined with tibial error, internal/external rotation angle and distraction-compression were the knee kinematics parameters most affected by RSTAM during the gait cycle, with average rms values of 3.8° and 11.1 mm. This study highlighted higher RSTAM during the swing phase particularly in the thigh segment and suggests new features for RSTAM such as the particular shape of some RSTAM waveforms and the absence of RSTAM in certain kinematics during the gait phases. The comparison of coefficient of multiple correlations showed some similarities of RSTAM between subjects, while some correlations were found with gait speed and BMI. These new insights could potentially allow the development of new methods of compensation to avoid STA.
Resumo:
Recent literature has highlighted that the flexibility of walking barefoot reduces overload in individuals with knee osteoarthritis (OA). As such, the aim of this study was to evaluate the effects of inexpensive, flexible, non-heeled footwear (Moleca (R)) as compared with a modern heeled shoes and walking barefoot on the knee adduction moment (KAM) during gait in elderly women with and without knee OA. The gait of 45 elderly women between 60 and 70 years of age was evaluated. Twenty-one had knee OR graded 2 or 3 according to Kellgren and Lawrence`s criteria, and 24 who had no OA comprised the control group (CG). The gait conditions were: barefoot, Moleca (R), and modern heeled shoes. Three-dimensional kinematics and ground reaction forces were measured to calculate KAM by inverse dynamics. For both groups, the Moleca (R) provided peak KAM and KAM impulse similar to barefoot walking. For the OA group, the Moleca (R) reduced KAM even more as compared to the barefoot condition during midstance. On the other hand, the modern heeled shoes increased this variable in both groups. Inexpensive, flexible, and non-heeled footwear provided loading on the knee joint similar to a barefoot gait and significant overload decreases in elderly women with and without knee OA, compared to modern heeled shoes. During midstance, the Moleca (R) also allowed greater reduction in the knee joint loads as compared to barefoot gait in elderly women with knee OA, with the further advantage of providing external foot protection during gait. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
ackground Following incomplete spinal cord injury (iSCI), descending drive is impaired, possibly leading to a decrease in the complexity of gait. To test the hypothesis that iSCI impairs gait coordination and decreases locomotor complexity, we collected 3D joint angle kinematics and muscle parameters of rats with a sham or an incomplete spinal cord injury. Methods 12 adult, female, Long-Evans rats, 6 sham and 6 mild-moderate T8 iSCI, were tested 4 weeks following injury. The Basso Beattie Bresnahan locomotor score was used to verify injury severity. Animals had reflective markers placed on the bony prominences of their limb joints and were filmed in 3D while walking on a treadmill. Joint angles and segment motion were analyzed quantitatively, and complexity of joint angle trajectory and overall gait were calculated using permutation entropy and principal component analysis, respectively. Following treadmill testing, the animals were euthanized and hindlimb muscles removed. Excised muscles were tested for mass, density, fiber length, pennation angle, and relaxed sarcomere length. Results Muscle parameters were similar between groups with no evidence of muscle atrophy. The animals showed overextension of the ankle, which was compensated for by a decreased range of motion at the knee. Left-right coordination was altered, leading to left and right knee movements that are entirely out of phase, with one joint moving while the other is stationary. Movement patterns remained symmetric. Permutation entropy measures indicated changes in complexity on a joint specific basis, with the largest changes at the ankle. No significant difference was seen using principal component analysis. Rats were able to achieve stable weight bearing locomotion at reasonable speeds on the treadmill despite these deficiencies. Conclusions Decrease in supraspinal control following iSCI causes a loss of complexity of ankle kinematics. This loss can be entirely due to loss of supraspinal control in the absence of muscle atrophy and may be quantified using permutation entropy. Joint-specific differences in kinematic complexity may be attributed to different sources of motor control. This work indicates the importance of the ankle for rehabilitation interventions following spinal cord injury.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Background: The goal of this study was to determine if increasing strength in primary knee extensors and flexors would directly affect net knee joint moments during a common functional task in persons with knee osteoarthritis. Methods: An exploratory single sample clinical trial with pre-post treatment measures was used to study volunteers with clinical diagnosis of mild knee osteoarthritis (OA) in one knee. Subjects participated in an individually supervised training program 3 times a week for eight weeks consisting of progressive resistive exercises for knee extensors and knee flexors. Pre and post training outcome assessments included: 1. Net internal knee joint moments, 2. Electromyography of primary knee extensors and flexors, and 3. Self-report measures of knee pain and function. The distribution of lower extremity joint moments as a percent of the total support moment was also investigated. Findings: Pain, symptoms, activities of daily life, quality of life, stiffness, and function scores showed significant improvement following strength training. Knee internal valgus and hip internal rotation moments showed increasing but non-statistically significant changes post-training. There were no significant differences in muscle co-contraction activation of the Quadriceps and Hamstrings. Interpretation: While exercise continues to be an important element of OA management, the results of this study suggest improvements in function, pain, and other symptoms, as a result of strength training may not be causally related to specific biomechanical changes in net joint moments. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Semiquantitative assessment of the knee by expert magnetic resonance imaging readers is a powerful research tool for understanding the natural history of osteoarthritis (OA). Several reliable semiquantitative scoring systems have been applied to large observational cross-sectional and longitudinal epidemiologic studies and interventional clinical trials. Such evaluations have enabled understanding of the relevance of disease in structures within the knee joint to explain pain and progression of OA. Compositional imaging of cartilage has added to our ability to detect early degeneration before morphologic changes are present, which may help to prevent the permanent morphologic changes commonly seen in knee OA.
Resumo:
Posterolateral corner (PLC) injuries of the knee are uncommon injury patterns that may result in significant degrees of functional disability. When surgery is necessary to address this injury a good knowledge of anatomy and a good surgical exposure is the mainstay. This report reviews the complex anatomy of the posterolateral corner (PLC) of knee and describes the osteotomy of Gerdy tubercle as a technical variant to approach this anatomical region. This surgical step allowing a good mobilisation of the multiple layers of ilio-tibial tract from distal to proximal makes an excellent exposure of the PLC structures with absence of morbidity.
Resumo:
The intra-articular osteoid osteoma (10-13% of the cases) is often difficult to identify. They present frequent atypical clinical signs and radiological images that eventually lead to inadequate treatment. For example, it has been observed that this pathology leads to inappropriate arthroscopies (up to 40%). Meniscal tear and then osteochondritis were initially suspected on a patient with an intra-articular osteoid osteoma at the tibia level. For the treatment, any damage of the cartilage has to be avoided. Thermoablation with radiofrequency is the treatment of choice
Resumo:
Stress radiographs have been recommended in order to obtain a better objective quantification of abnormal compartment knee motion. This tool has showed to be superior in quantifying a posterior cruciate ligament (PCL) lesion compared to clinical or arthrometer evaluation. Different radiographic techniques have been described in literature to quantify posterior pathological laxity. In this study we evaluated the total amount of posterior displacement (PTD) and side to side difference (SSD), before and after surgical reconstruction of PCL or PCL and posterolateral complex (PLC), using two different stress radiography techniques (Telos stress and kneeling view). Twenty patients were included in this study. We found a statistical significant difference about both total PTD and SSD among the two techniques preoperatively and at follow-up, with greatest values occurring using the kneeling view. Although stress radiographies has been introduced to allow an objective quantification of laxity in ligamentous injured knee, we believe that further studies on a large numbers of subjects are required to define the relationship between PTD values, measured with stress knee radiography, particularly using kneeling view, and ligamentous knee injury, in order to obtain a real useful tool in the decision making process, as well as to evaluate the outcome after ligamentous surgery.
Resumo:
Introduction: Enchondromas are among the most current benign bone tumours. Malignant degeneration is extremely rare (<1%) and generally presents as a low grade chondrosarcoma. For localized grade 1 lesions, the treatment of choice is curettage. Wide excision and reconstruction is generally not necessary, unless locally advanced or more aggressive behaviour is suspected at presentation. Case report: A healthy 72 yo male presented with pain and recurrent knee joint effusion. X-rays show a classical central distal metaphyseal enchondroma of the femur associated with subtle osteolysis of the lateral condyle. MRI confirms the presence of a locally aggressive chondromatous lesion based in a classical enchondroma. Core needle biopsy revealed a grade 1 chondrosarcoma, which was in contrast to the radiological aggressiveness of the lesion. Total body CT-scan did not reveal metastatic disease. A wide resection was planned, as a high-grade lesion and joint contamination was suspected. We performed an extra-articular knee resection and reconstruction with a hinged modular total knee megaprosthesis. The definitive histology was grade 1 chondrosarcoma, the surgical margins were wide. The evolution was favourable and the patient was able to perform all his activities of daily living independently without pain at 6 weeks postop. Knee flexion reached 90°. The oncologic screening at 18 months did not show local or distant recurrence. Conclusion: Joints near a benign tumour that suddenly become symptomatic or present an effusion might indicate a malignant transformation. Wide resection and prosthetic reconstruction remains an effective treatment option even in low grade cartilaginous lesions if (1) the adjacent joint is contaminated, or (2) joint-sparing surgery would result in a severe functional impairment of the limb.
Resumo:
Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.