871 resultados para Intra-subject alignment
Resumo:
Most external assessments of cervical range of motion assess the upper and lower cervical regions simultaneously. This study investigated the within and between days reliability of the clinical method used to bias this movement to the upper cervical region, namely measuring rotation of the head and neck in a position of full cervical flexion. Measurements were made using the Fastrak measurement system and were conducted by one operator. Results indicated high levels of within and between days repeatability (range of ICC2,1 values: 0.85-0.95). The ranges of axial rotation to right and left, measured with the neck positioned in full flexion, were approximately 56% and 50%, respectively of total cervical rotation, which relates well to the proportional division of rotation in the upper and lower cervical regions. These results suggest that this method of measuring rotation would be appropriate for use in subject studies where movement dysfunction is present in the upper cervical region, such as those with cervicogenic headache. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Given the dynamic nature of cardiac function, correct temporal alignment of pre-operative models and intraoperative images is crucial for augmented reality in cardiac image-guided interventions. As such, the current study focuses on the development of an image-based strategy for temporal alignment of multimodal cardiac imaging sequences, such as cine Magnetic Resonance Imaging (MRI) or 3D Ultrasound (US). First, we derive a robust, modality-independent signal from the image sequences, estimated by computing the normalized crosscorrelation between each frame in the temporal sequence and the end-diastolic frame. This signal is a resembler for the left-ventricle (LV) volume curve over time, whose variation indicates di erent temporal landmarks of the cardiac cycle. We then perform the temporal alignment of these surrogate signals derived from MRI and US sequences of the same patient through Dynamic Time Warping (DTW), allowing to synchronize both sequences. The proposed framework was evaluated in 98 patients, which have undergone both 3D+t MRI and US scans. The end-systolic frame could be accurately estimated as the minimum of the image-derived surrogate signal, presenting a relative error of 1:6 1:9% and 4:0 4:2% for the MRI and US sequences, respectively, thus supporting its association with key temporal instants of the cardiac cycle. The use of DTW reduces the desynchronization of the cardiac events in MRI and US sequences, allowing to temporally align multimodal cardiac imaging sequences. Overall, a generic, fast and accurate method for temporal synchronization of MRI and US sequences of the same patient was introduced. This approach could be straightforwardly used for the correct temporal alignment of pre-operative MRI information and intra-operative US images.
Resumo:
RESUMO: Introdução: A relação cinemática entre as articulações do CAO apresenta grande importância na função do MS, e é por isso cada vez mais investigada e descrita. O posicionamento da omoplata ganha um importante papel para compreender as DCAO. É indiscutível o importante papel da omoplata na dinâmica do MS, bem como o posicionamento escapular como parâmetro clínico de disfunção do CAO. Todos estes factores criam a necessidade de desenvolver instrumentos de avaliação da posição da articulação ET. A grande maioria dos testes de avaliação, restringem a sua avaliação às disfunções da articulação GU, não integrando uma avaliação mais dinâmica e interactiva que respeite os pressupostos teóricos inerentes ao REU. È importante também que os métodos de avaliação sejam de fácil aplicabilidade clínica e que avaliem fidedignamente e com validade os outcomes. Objectivos: Contribuir para o desenvolvimento de uma metodologia de avaliação da omoplata em diferentes amplitudes do MS, através do estudo da validade concorrente, da fidedignidade intra e inter-observador. Metodologia: A amostra foi constituída por 20 elementos seleccionados por conveniência, entre o corpo de discentes da ESS-IPS, sem história de disfunção do CAO. Foi realizada uma análise cinemática ao MS de cada sujeito, usando um aparelho de análise por varrimento electromagnético, o FOB. Em cada sujeito foram ainda medidas, as distâncias escapulares em estudo, usando a fita métrica. Cada método de medição foi constituído por dois momento (teste e reteste), em cada momento, as medidas eram recolhidas por dois investigadores distintos. Resultados e Discussão: Foram considerados como positivos os resultados que se apresentassem acima do limiar de 0,5, que classifica uma correlação como moderada a excelente. Os resultados da validade mostram que para o investigador 1 nas medidas M1e M2 apenas houve correlação com valores excelentes a moderados até aos 30º de elevação do MS. Já para M3 apenas aos 30º no plano da omoplata essa mesma correlação não tem valores próximos do cutpoint. Em M4 nenhum valor tem correlação significativa com os valores do FOB, chegando mesmo a haver correlação negativa para os 120º no plano da omoplata. Em M5 apenas os 0º mostram valores correlacionais excelentes a moderados. Para o investigador 2, em M1 e M2 á semelhança do investigador 1, só existem valores de correlação significativos até aos 30º de elevação do MS. Já para M3 todos os valores mostram excelente a moderada correlação á excepção dos 120º no plano frontal. Em M4 este investigador apresenta maus resultados. Já em M5 os valores de correlação são moderados aos 0º e aos 90º. No que diz respeitos aos resultados dos CCI intra-observador,podemos afirmar que foi em M5 que estes valores mais se aproximaram do cut point. M1 e M2 são as medidas onde se encontram resultados menos satisfatórios. É aos 60º que existem valores mais satisfatórios, seguidos pelos 0º e 30º, quando nos aproximamos de graus mais elevados, como 90º e 120º, estes valores tendem a baixar. Quanto á fidedignidade inter-observador para M1 apenas aos 90º e aos 120º houve valores de correlação abaixo do cutpoint. Em M2, só os 60º do plano sagital não teve valores acima do cutpoint, em M3 apenas os 30º plano sagital não obtiveram valores acima do cut-point, o mesmo acontece para M3 aos 30º plano da omoplata e em M5 aos 30º e 120º no plano frontal. Conclusão: Os resultados deste estudo indicam que a metodologia em causa apresenta elevado grau de fidedignidade inter-observador, já no que toca é fidedignidade intra-observador o grau de semelhança não é tão elevado. Também o erro associado á medida não ultrapassou 1,5cm, sendo considerado baixo. Na validade concorrente concluímos que é aos 0º que a metodologia se torna uma opção válida na aferição das distâncias medidas com uma boa a excelente concordância com o FOB. As medidas consideradas como opções válidas, nas diferentes amplitudes, podem funcionar como parâmetros clínicos de caracterização do posicionamento da omoplata, podendo vir a contribuir ainda para a caracterização da orientação da mesma.-------------------- ABSTRACT:Introduction: The kinematic relationship between the joints of the CAO has great importance in the function of MS, which is why more and more investigated and described. The positioning of the blade gets an important role in understanding the DCAO. There is no doubt the important role of the scapula in the dynamics of MS as well as the positioning of scapular dysfunction as a clinical parameter of the CAO. All these factors create the need to develop tools for evaluating the place of articulation ET. Most assessment tests, restrict its assessment to GU joint disorders, not incorporating a more dynamic and interactive way that respects the theoretical assumptions inherent in the REU. It is also important that the methods are easy to apply clinical and reliably to assess the validity and outcomes. Objectives: To contribute to the development of a methodology for evaluating the scapula in different ranges of MS, through the study of concurrent validity, reliability of intra-and inter-observer. Methodology: The sample consisted of 20 selected elements for convenience, between the body of students of IPS-ESS with no history of dysfunction of the CAO. We performed a kinematic analysis of each subject to MS, using a scanning device for electromagnetic analysis, the FOB. In each subject were also measured, the scapular distances under study, using tape measure. Each method of measuring the time consisted of two (test and retest), in each moment, the measures were collected by two different investigators. Results and Discussion: We considered as positive results that were above the threshold of 0.5, which ranks as a moderate to excellent correlation. The results show that the validity for the researcher in an action M1e M2 was only correlated with moderate to excellent values up to 30º of elevation of the MS. As for M3 only to 30º in the plane of the scapula has the same correlation values near the cutpoint. M4 has no value in correlation with the values of the FOB, and even negative correlation to 120 ° in the plane of the scapula. In M5 show only the values 0 ° correlational excellent to moderate. For investigator 2 in M1 and M2 will be like an investigator, there are only significant correlation values up to 30º of elevation of the MS. As for M3 all the values show excellent correlation to moderate with the exception of 120 ° in the frontal plane. In this researcher M4 has bad results. M5 already in the correlation values are moderate to 0º and 90 º. Regarding the results of ICC intra-observer, we can say that M5 was that these values come closest to the cut point. M1 and M2 are measures which are less than satisfactory results. At 60 ° there are more satisfactory values, followed by 0º and 30º, when we approached the highest levels, such as 90 ° and 120 °, these values tend to decrease. The inter-observer reliability for M1 only to 90 º and 120 ºcorrelation values were below the cutpoint. In M2, only 60 of the sagital plane did not have values above the cutpoint in M3 only 30º sagital plane did not obtain values above the cut-point, the same goes for M3 at 30 ° plane of the scapula and M5 at 30 º and 120 º in frontal plane. Conclusion: The results of this study indicate that the methodology in question has a high degree of inter-observer reliability, as far as intra-observer reliability is the degree of similarity is not as high. Also the error of measure did not exceed 1.5 cm, and is considered low. In concurrent validity conclude that it is at 0 ° the methodology becomes a valid option for the measurement of distances measured with a good to excellent agreement with the FOB. The measures considered as valid options in different amplitudes, can function as clinical parameters to characterize the positioning of the shoulder blade and could further contribute to the characterization of the orientation of the same.
Resumo:
Despite advances in diagnosis, surgery, and antimicrobial therapy, mortality rates associated with complicated intra-abdominal infections remain exceedingly high. The World Society of Emergency Surgery (WSES) has designed the CIAOW study in order to describe the clinical, microbiological, and management-related profiles of both community- and healthcare-acquired complicated intra-abdominal infections in a worldwide context. The CIAOW study (Complicated Intra-Abdominal infection Observational Worldwide Study) is a multicenter observational study currently underway in 57 medical institutions worldwide. The study includes patients undergoing surgery or interventional drainage to address complicated intra-abdominal infections. This preliminary report includes all data from almost the first two months of the six-month study period. Patients who met inclusion criteria with either community-acquired or healthcare-associated complicated intra-abdominal infections (IAIs) were included in the study. 702 patients with a mean age of 49.2 years (range 18-98) were enrolled in the study. 272 patients (38.7%) were women and 430 (62.3%) were men. Among these patients, 615 (87.6%) were affected by community-acquired IAIs while the remaining 87 (12.4%) suffered from healthcare-associated infections. Generalized peritonitis was observed in 304 patients (43.3%), whereas localized peritonitis or abscesses was registered in 398 (57.7%) patients.The overall mortality rate was 10.1% (71/702). The final results of the CIAOW Study will be published following the conclusion of the study period in March 2013.
Resumo:
The CIAO Study ("Complicated Intra-Abdominal infection Observational" Study) is a multicenter investigation performed in 68 medical institutions throughout Europe over the course of a 6-month observational period (January-June 2012).Patients with either community-acquired or healthcare-associated complicated intra-abdominal infections (IAIs) were included in the study.2,152 patients with a mean age of 53.8 years (range: 4-98 years) were enrolled in the study. 46.3% of the patients were women and 53.7% were men. Intraperitoneal specimens were collected from 62.2% of the enrolled patients, and from these samples, a variety of microorganisms were collectively identified.The overall mortality rate was 7.5% (163/2.152).According to multivariate analysis of the compiled data, several criteria were found to be independent variables predictive of patient mortality, including patient age, the presence of an intestinal non-appendicular source of infection (colonic non-diverticular perforation, complicated diverticulitis, small bowel perforation), a delayed initial intervention (a delay exceeding 24 hours), sepsis and septic shock in the immediate post-operative period, and ICU admission.Given the sweeping geographical distribution of the participating medical centers, the CIAO Study gives an accurate description of the epidemiological, clinical, microbiological, and treatment profiles of complicated intra-abdominal infections (IAIs) throughout Europe.
Resumo:
Critical limb ischemia in diabetic patients is associated with high rates of morbidity and mortality. Suboptimal responses to the available medical and surgical treatments are common in these patients, who also demonstrate limited vascular homeostasis. Neovasculogenesis induced by stem cell therapy could be a useful approach for these patients. Neovasculogenesis and clinical improvement were compared at baseline and at 3 and 12 months after autologous bone marrow-derived mononuclear cell (BMMNC) transplantation in diabetic patients with peripheral artery disease. We conducted a prospective study to evaluate the safety and efficacy of intra-arterial administration of autologous BMMNCs (100-400 × 10(6) cells) in 20 diabetic patients with severe below-the-knee arterial ischemia. Although the time course of clinical effects differed among patients, after 12 months of follow-up all patients presented a notable improvement in the Rutherford-Becker classification, the University of Texas diabetic wound scales, and the Ankle-Brachial Index in the target limb. The clinical outcome was consistent with neovasculogenesis, which was assessed at 3 months by digital subtraction angiography and quantified by MetaMorph software. Unfortunately, local cell therapy in the target limb had no beneficial effect on the high mortality rate in these patients. In diabetic patients with critical limb ischemia, intra-arterial perfusion of BMMNCs is a safe procedure that generates a significant increase in the vascular network in ischemic areas and promotes remarkable clinical improvement.
Resumo:
The CIAOW study (Complicated intra-abdominal infections worldwide observational study) is a multicenter observational study underwent in 68 medical institutions worldwide during a six-month study period (October 2012-March 2013). The study included patients older than 18 years undergoing surgery or interventional drainage to address complicated intra-abdominal infections (IAIs). 1898 patients with a mean age of 51.6 years (range 18-99) were enrolled in the study. 777 patients (41%) were women and 1,121 (59%) were men. Among these patients, 1,645 (86.7%) were affected by community-acquired IAIs while the remaining 253 (13.3%) suffered from healthcare-associated infections. Intraperitoneal specimens were collected from 1,190 (62.7%) of the enrolled patients. 827 patients (43.6%) were affected by generalized peritonitis while 1071 (56.4%) suffered from localized peritonitis or abscesses. The overall mortality rate was 10.5% (199/1898). According to stepwise multivariate analysis (PR = 0.005 and PE = 0.001), several criteria were found to be independent variables predictive of mortality, including patient age (OR = 1.1; 95%CI = 1.0-1.1; p < 0.0001), the presence of small bowel perforation (OR = 2.8; 95%CI = 1.5-5.3; p < 0.0001), a delayed initial intervention (a delay exceeding 24 hours) (OR = 1.8; 95%CI = 1.5-3.7; p < 0.0001), ICU admission (OR = 5.9; 95%CI = 3.6-9.5; p < 0.0001) and patient immunosuppression (OR = 3.8; 95%CI = 2.1-6.7; p < 0.0001).
Resumo:
Critical limb ischemia in diabetic patients is associated with high rates of morbidity and mortality. Suboptimal responses to the available medical and surgical treatments are common in these patients, who also demonstrate limited vascular homeostasis. Neovasculogenesis induced by stem cell therapy could be a useful approach for these patients. Neovasculogenesis and clinical improvement were compared at baseline and at 3 and 12 months after autologous bone marrow-derived mononuclear cell (BMMNC) transplantation in diabetic patients with peripheral artery disease. We conducted a prospective study to evaluate the safety and efficacy of intra-arterial administration of autologous BMMNCs (100-400 × 10(6) cells) in 20 diabetic patients with severe below-the-knee arterial ischemia. Although the time course of clinical effects differed among patients, after 12 months of follow-up all patients presented a notable improvement in the Rutherford-Becker classification, the University of Texas diabetic wound scales, and the Ankle-Brachial Index in the target limb. The clinical outcome was consistent with neovasculogenesis, which was assessed at 3 months by digital subtraction angiography and quantified by MetaMorph software. Unfortunately, local cell therapy in the target limb had no beneficial effect on the high mortality rate in these patients. In diabetic patients with critical limb ischemia, intra-arterial perfusion of BMMNCs is a safe procedure that generates a significant increase in the vascular network in ischemic areas and promotes remarkable clinical improvement.
Resumo:
The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners.
Resumo:
When a rubber hand is placed on a table top in a plausible position as if part of a person"s body, and is stroked synchronously with the person"s corresponding hidden real hand, an illusion of ownership over the rubber hand can occur (Botvinick and Cohen 1998). A similar result has been found with respect to a virtual hand portrayed in a virtual environment, a virtual hand illusion (Slater et al. 2008). The conditions under which these illusions occur have been the subject of considerable study. Here we exploited the flexibility of virtual reality to examine four contributory factors: visuo-tactile synchrony while stroking the virtual and the real arms, body continuity, alignment between the real and virtual arms, and the distance between them. We carried out three experiments on a total of 32 participants where these factors were varied. The results show that the subjective illusion of ownership over the virtual arm and the time to evoke this illusion are highly dependent on synchronous visuo-tactile stimulation and on connectivity of the virtual arm with the rest of the virtual body. The alignment between the real and virtual arms and the distance between these were less important. It was found that proprioceptive drift was not a sensitive measure of the illusion, but was only related to the distance between the real and virtual arms.
Resumo:
Tutkimuksen tavoitteena oli selvittää sisäisen kommunikoinnin tilannetta case-yrityksissä. Yritykset kuuluvat kahteen case-arvoverkostoon, jotka toimivat informaatio- ja kommunikaatioteknologian alalla. Sisäinen kommunikointi valittiin tutkimusalueeksi, koska se muodostaa perustan ulkoiselle, yritysten väliselle kommunikoinnille. Tutkimuksen painopiste oli web-pohjaisessa kommunikoinnissa ja webin ominaisuuksissa arvoverkoston näkökulmasta. Tutkimusprosessissa käytettiin sekä kvalitatiivisia että kvantitatiivisia menetelmiä. Tutkimuksen kvantitatiivinen osa toteutettiin web-kyselynä, jonka tulokset osoittivat, että case-yritysten sisäinen kommunikointi perustuu pääasiassa perinteisten kommunikointivälineiden käyttöön. Toisin sanoen, webin hyödyntäminen on vähäistä, mihin vaikuttavat monet eri tekijät. Webissä on kuitenkin useita ominaisuuksia, jotka parantavat kommunikointia arvoverkostossa ja siksi nämä web-pohjaiset välineet tulisi huomioida, kun suunnitellaan yleistä kommunikointijärjestelmää. Tutkimuksen teoreettisessa osassa määriteltiin vuorovaikutteisuus-ominaisuuteen perustuva kommunikointivälineiden luokittelu. Tämän lisäksi määriteltiin myös arvoverkoston käsite. Empiirinen osa koostui web-kyselyn toteutuksen ja tulosten raportoinnista, jonka jälkeen yhteenvetokappale koosti merkittävimmät havainnot sekä mahdolliset jatkotutkimusaiheet.
Resumo:
In this thesis, simple methods have been sought to lower the teacher’s threshold to start to apply constructive alignment in instruction. From the phases of the instructional process, aspects that can be improved with little effort by the teacher have been identified. Teachers have been interviewed in order to find out what students actually learn in computer science courses. A quantitative analysis of the structured interviews showed that in addition to subject specific skills and knowledge, students learn many other skills that should be mentioned in the learning outcomes of the course. The students’ background, such as their prior knowledge, learning style and culture, affects how they learn in a course. A survey was conducted to map the learning styles of computer science students and to see if their cultural background affected their learning style. A statistical analysis of the data indicated that computer science students are different learners than engineering students in general and that there is a connection between the student’s culture and learning style. In this thesis, a simple self-assessment scale that is based on Bloom’s revised taxonomy has been developed. A statistical analysis of the test results indicates that in general the scale is quite reliable, but single students still slightly overestimate or under-estimate their knowledge levels. For students, being able to follow their own progress is motivating, and for a teacher, self-assessment results give information about how the class is proceeding and what the level of the students’ knowledge is.
Resumo:
The alignment of model amyloid peptide YYKLVFFC is investigated in bulk and at a solid surface using a range of spectroscopic methods employing polarized radiation. The peptide is based on a core sequence of the amyloid beta (A beta) peptide, KLVFF. The attached tyrosine and cysteine units are exploited to yield information on alignment and possible formation of disulfide or dityrosine links. Polarized Raman spectroscopy on aligned stalks provides information on tyrosine orientation, which complements data from linear dichroism (LD) on aqueous solutions subjected to shear in a Couette cell. LD provides a detailed picture of alignment of peptide strands and aromatic residues and was also used to probe the kinetics of self-assembly. This suggests initial association of phenylalanine residues, followed by subsequent registry of strands and orientation of tyrosine residues. X-ray diffraction (XRD) data from aligned stalks is used to extract orientational order parameters from the 0.48 nm reflection in the cross-beta pattern, from which an orientational distribution function is obtained. X-ray diffraction on solutions subject to capillary flow confirmed orientation in situ at the level of the cross-beta pattern. The information on fibril and tyrosine orientation from polarized Raman spectroscopy is compared with results from NEXAFS experiments on samples prepared as films on silicon. This indicates fibrils are aligned parallel to the surface, with phenyl ring normals perpendicular to the surface. Possible disulfide bridging leading to peptide dimer formation was excluded by Raman spectroscopy, whereas dityrosine formation was probed by fluorescence experiments and was found not to occur except under alkaline conditions. Congo red binding was found not to influence the cross-beta XRD pattern.
Resumo:
Artificial diagenesis of the intra-crystalline proteins isolated from Patella vulgata was induced by isothermal heating at 140 °C, 110 °C and 80 °C. Protein breakdown was quantified for multiple amino acids, measuring the extent of peptide bond hydrolysis, amino acid racemisation and decomposition. The patterns of diagenesis are complex; therefore the kinetic parameters of the main reactions were estimated by two different methods: 1) a well-established approach based on fitting mathematical expressions to the experimental data, e.g. first-order rate equations for hydrolysis and power-transformed first-order rate equations for racemisation; and 2) an alternative model-free approach, which was developed by estimating a “scaling” factor for the independent variable (time) which produces the best alignment of the experimental data. This method allows the calculation of the relative reaction rates for the different temperatures of isothermal heating. High-temperature data were compared with the extent of degradation detected in sub-fossil Patella specimens of known age, and we evaluated the ability of kinetic experiments to mimic diagenesis at burial temperature. The results highlighted a difference between patterns of degradation at low and high temperature and therefore we recommend caution for the extrapolation of protein breakdown rates to low burial temperatures for geochronological purposes when relying solely on kinetic data.
Resumo:
The railroad, from 1870 and on, becomes an usual complaining in the press s and politician elite s speeches, especially because of Natal s geographic isolation. The implantation of two railroads in the capital territory Estrada de Ferro de Natal a Nova Cruz, afterwards part of Great Western Railway Company network, and Estrada de Ferro Central do Rio Grande do Norte had serious implications in the urban environment. While railroad s structures were already consolidated, other transportation mechanisms were being implanted in the first decades of the 20th century, such as trams lines, which, by the way, was a transport modal that also used rails as a dislocation meaning. Considering these questions, we may ask: how come railroads and tramways demands, roads and buildings had influenced the internal organization of Natal? We work with the general hypothesis that the influence of technical networks, composed by tramways and railroads, over Natal s urban space happened in a diversified way, sometimes consolidating social aspects in certain areas, sometimes improving the occupation of others. The impact over the city s territory also happens in a diversified way between the buildings/railroad s complexes and the pathways. The different scale of the train in comparison to the trams velocity, size, noise level, flow, among others is also a cause to the different consequences in urban environment. The main objective of this work is to understand the role of circulation technical networks in the construction process of urban space in Natal, as a way to contribute to the urban historiography about the subject. The time frame adopted, between 1881 and 1937, marks the time path of railroads and tramways in Rio Grande do Norte: 1881 is the year of railroad s first section inauguration from Natal to São José do Mipibu as well of the railroad complex in the Republic Square in Natal; the year of 1937 marks the beginning of tramways declination process in the city. At this time railroads and tramways had to face more intensively the competition of motor vehicles. The theory reference adopted is based on concepts and analysis of authors, such as Flávio Villaça and Roberto Lobato Corrêa references to the concepts of urban structure , localization and accessibility and Gabriel Dupuy to explain the concept of urban technical networks . These references reveal the conflict of different realities in the urban universe interests and values which is an important factor about the construction of urban space. The information sources used were from two distinctive natures: primary, journals of the time studied and official government reports, and secondary, based on other works about the subject. It was also used by this study iconographic source, especially images from the data base of the research group História da Cidade, do Território e do Urbanismo .