958 resultados para Intra-examiner reproducibility
Resumo:
The assessment of adenoids by x-ray imaging has been the topic of heated debate, but few studies have looked into the reliability of most existing radiographic parameters. Objective: This study aims to verify the intra-examiner and inter-examiner reproducibility of the adenoid radiographic assessment methods. Materials and Methods: This is a cross-sectional case series study. Forty children of both genders aged between 4 and 14 were enrolled. They were selected based on complaints of nasal obstruction or mouth breathing and suspicion of pharyngeal tonsil hypertrophy. Cavum x-rays and orthodontic teleradiographs were assessed by two examiners in quantitative and categorical terms. Results: All quantitative parameters in both x-ray modes showed excellent intra and inter-examiner reproducibility. Relatively better performance was observed in categorical parameters used in cavum x-ray assessment by C-Kurien, C-Wang, C-Fujioka, and C-Elwany over C-Cohen and C-Ysunza. As for orthodontic teleradiograph grading systems, C-McNamara has been proven to be more reliable than C-Holmberg. Conclusion: Most instruments showed adequate reproducibility levels. However, more research is needed to properly determine the accuracy and viability of each method.
Resumo:
The aim of this study was to compare the in situ and in vitro performances of a laser fluorescence (LF) device (DIAGNOdent 2095) with visual inspection for the detection of occlusal caries in permanent teeth. Sixty-four sites were selected, and visual inspection and LF assessments were carried out, in vitro, three times by two independent examiners, with a 1-week interval between evaluations. Afterwards, the occlusal surfaces were mounted on the palatal portion of removable acrylic orthodontic appliances and placed in six volunteers. Assessments were repeated and validated by histological analysis of the tooth sections under a stereomicroscope. For both examiners, the highest intra-examiner values were observed for the visual inspection when in vitro and in situ evaluations were compared. The inter-examiner reproducibility varied from 0.61 to 0.64, except for the in vitro assessment using LF, which presented a lower value (0.43). The methods showed high specificity at the D(1) threshold (considering enamel and dentin caries as disease). In vitro evaluations showed the highest values of sensitivity for both methods when compared to the in situ evaluations at D(1) and D(2) (considering only dentinal caries as the disease) thresholds. For both methods, the results of sensitivity (at D(1) and D(2)) and accuracy (at D(1)) showed significant differences between in vitro and in situ conditions. However, the sensitivity (at D(1) and D(2)), specificity and accuracy (both at D(1)) of the methods were not significantly different when the same condition was considered. It can be concluded that visual inspection and LF showed better performance in vitro than in situ.
Resumo:
The objective of this study was to investigate whether it is possible to pool together diffusion spectrum imaging data from four different scanners, located at three different sites. Two of the scanners had identical configuration whereas two did not. To measure the variability, we extracted three scalar maps (ADC, FA and GFA) from the DSI and utilized a region and a tract-based analysis. Additionally, a phantom study was performed to rule out some potential factors arising from the scanner performance in case some systematic bias occurred in the subject study. This work was split into three experiments: intra-scanner reproducibility, reproducibility with twin-scanner settings and reproducibility with other configurations. Overall for the intra-scanner and twin-scanner experiments, the region-based analysis coefficient of variation (CV) was in a range of 1%-4.2% and below 3% for almost every bundle for the tract-based analysis. The uncinate fasciculus showed the worst reproducibility, especially for FA and GFA values (CV 3.7-6%). For the GFA and FA maps, an ICC value of 0.7 and above is observed in almost all the regions/tracts. Looking at the last experiment, it was found that there is a very high similarity of the outcomes from the two scanners with identical setting. However, this was not the case for the two other imagers. Given the fact that the overall variation in our study is low for the imagers with identical settings, our findings support the feasibility of cross-site pooling of DSI data from identical scanners.
Resumo:
INTRODUCTION: Humanized and quality prenatal and post-partum care is critical to maternal and newborn health, as well as oral health care. Currently, the National Oral Health Policy is aiming at expanding dental care for pregnant women. Thus, the promotion of oral health and attention to prenatal care policies should be integrated; however, there is still limited participation of pregnant women. Thus, it is necessary to verify the knowledge of pregnant women related to oral health, seeking to estimate the quality of dental care provided during prenatal care, being essential for the Family Health strategy to organize personnel, plan costs and to ensure the quality standard of care. OBJECTIVE: To develop and validate a research instrument on the knowledge of pregnant women about their oral health and of their baby. METHOD: This is a construction and validation study with 93 pregnant women in Family Health Units and specialized private clinics in Obstetrics, in the city of Natal / RN. It was authorized by the Onofre Lopes University Hospital Ethics Committee of the Universidade Federal do Rio Grande do Norte (UFRN) under the registration number 421.163/13. The construction of the instrument followed steps so that it was valid, reliable and sensitive: creation and reduction of the items (drafting of the instrument), content validity and testing of the instrument, and hypotheses validation. Once constructed, the instrument was evaluated by experts who suggested modifications. There was consultation with the target population about the new version of the created instrument, which had the instrument validation verified by internal consistency through intra and inter-calibration and test-retest. Next, the hypotheses were validated. A database was built in the Statistical Package for Social Sciences (SPSS), version 22.0. After creating the hypotheses, an association was found for validating the criteria between each of the specific issues for each established criteria, considering a 5% significance level. Data analysis was carried out by describing the absolute and relative frequencies of the variables pertaining to issues relating to their pregnancy knowledge about their oral health and their baby. The Kappa coefficient was used for the calibration process (Inter and Intra-examiner calibration) and Cronbach's alpha coefficient was used to analyze instrument reproducibility (test-retest). In addition, the chi-square test was used to cross the dependent variable with the (dichotomized) independent variables. RESULTS: The intra and inter agreement analysis presented a Kappa coefficient between 0.400 and 1.000. Internal consistency through the analysis showed that 90% of the instrument's questions showed great reliability in the answers (Cronbach α ˃ 0.7). In the investigation of the relationship between the dependent variable (knowledge about oral health) and the independent variables (trimester of pregnancy, education, income and multiparous), it was found that none of these independent variables were significantly associated. All hypotheses had their Ho confirmed. CONCLUSION: The constructed instrument was validated, considering that it showed to be sensitive with good reliability and good accuracy, and therefore can be used to assess pregnant women’s knowledge about their oral health and the oral health of their baby.
Resumo:
INTRODUCTION: Humanized and quality prenatal and post-partum care is critical to maternal and newborn health, as well as oral health care. Currently, the National Oral Health Policy is aiming at expanding dental care for pregnant women. Thus, the promotion of oral health and attention to prenatal care policies should be integrated; however, there is still limited participation of pregnant women. Thus, it is necessary to verify the knowledge of pregnant women related to oral health, seeking to estimate the quality of dental care provided during prenatal care, being essential for the Family Health strategy to organize personnel, plan costs and to ensure the quality standard of care. OBJECTIVE: To develop and validate a research instrument on the knowledge of pregnant women about their oral health and of their baby. METHOD: This is a construction and validation study with 93 pregnant women in Family Health Units and specialized private clinics in Obstetrics, in the city of Natal / RN. It was authorized by the Onofre Lopes University Hospital Ethics Committee of the Universidade Federal do Rio Grande do Norte (UFRN) under the registration number 421.163/13. The construction of the instrument followed steps so that it was valid, reliable and sensitive: creation and reduction of the items (drafting of the instrument), content validity and testing of the instrument, and hypotheses validation. Once constructed, the instrument was evaluated by experts who suggested modifications. There was consultation with the target population about the new version of the created instrument, which had the instrument validation verified by internal consistency through intra and inter-calibration and test-retest. Next, the hypotheses were validated. A database was built in the Statistical Package for Social Sciences (SPSS), version 22.0. After creating the hypotheses, an association was found for validating the criteria between each of the specific issues for each established criteria, considering a 5% significance level. Data analysis was carried out by describing the absolute and relative frequencies of the variables pertaining to issues relating to their pregnancy knowledge about their oral health and their baby. The Kappa coefficient was used for the calibration process (Inter and Intra-examiner calibration) and Cronbach's alpha coefficient was used to analyze instrument reproducibility (test-retest). In addition, the chi-square test was used to cross the dependent variable with the (dichotomized) independent variables. RESULTS: The intra and inter agreement analysis presented a Kappa coefficient between 0.400 and 1.000. Internal consistency through the analysis showed that 90% of the instrument's questions showed great reliability in the answers (Cronbach α ˃ 0.7). In the investigation of the relationship between the dependent variable (knowledge about oral health) and the independent variables (trimester of pregnancy, education, income and multiparous), it was found that none of these independent variables were significantly associated. All hypotheses had their Ho confirmed. CONCLUSION: The constructed instrument was validated, considering that it showed to be sensitive with good reliability and good accuracy, and therefore can be used to assess pregnant women’s knowledge about their oral health and the oral health of their baby.
Resumo:
Tradicionalmente, los ortodoncistas han realizado las mediciones dentales en los modelos de yeso, pero los avances tecnológicos permiten ahora a los ortodoncistas realizar esas mediciones en los modelos digitales. El propósito de este estudio fue comparar la fiabilidad y reproducibilidad de las medidas de los tamaños dentarios y las arcadas dentarias entre el método manual y los métodos digitales 3D obtenidos por un escáner intraoral CEREC Omnicam (Sirona Dental Systems) y dos escáneres extraorales: inEos X5 (Sirona Dental Systems) y Dental Scanner SMART (Open Technologies). Un modelo de yeso, un escaneado intraoral y dos modelos digitales con un escáner extraoral fueron realizadas para cada uno de los 20 sujetos. Las medidas de los tamaños dentarios, la distancia intercanina y la distancia intermolar de los modelos digitales se compararon con los correspondientes modelos de yeso (estándar de oro) Se utilizó el test de ANOVA para establecer la fiabilidad entre los cuatro métodos y el coeficiente de correlación intraclase fue calculado para determinar la reproducibilidad intra- e inter-examinador. Los resultados encontrados fueron que no existieron diferencias estadísticamente significativas entre las medidas hechas directamente en los modelos de yeso y los modelos digitales. Los coeficientes de correlación intraclase tanto intra- e inter-examinador fue alto y considerado bueno para los cuatro métodos de medición. CCI> 0.90. Se concluyó que las mediciones en los modelos digitales obtenidos con un escáner extraoral e intraoral son fiables y reproducibles
Resumo:
OBJECTIVE: This study aimed to asses oral health conditions in a population aged 60 years and over living in Botucatu, Southeastern Brazil. A cross-sectional population-based study was carried out using a random sample (N=372) of the urban population aged 60 years and over from the city of Botucatu, in 2005. World Health Organization criteria and codes for oral health epidemiological surveys were used. Re-examination was carried out in 10% of individuals aiming to evaluate intra-examiner agreement. Statistical analysis was performed by one-way ANOVA or Kruskal-Wallis ANOVA, as applicable. Also, the t-test was used in the absence of homoscedasticity. Fisher's exact test was used for situations where the categories with less than five units were observed. Adjusted residuals and multiple-comparison analysis were conducted to identify associations between variable categories and subgroups. The intra-examiner agreement was 98% and Kappa statistics result was 0.95. Loss component represented 90.68% of DMF-T index, which was 29.85. The prevalence of edentulism was 63.17%. Upper and lower dentures were found in 80% and 58% respectively, with complete denture as the most commonly used. In those studied, 15% required upper and 38% lower dentures. There was more need for complete denture in both jaws. Approximately 20% had soft tissue alterations. For periodontal conditions, most sextants were excluded (81.81%). Periodontal pockets (4 - 5 mm) were seen in 11.29% of the examined individuals. The oral health status of the elderly population in Botucatu is poor, as well as in other Brazilian cities. The results of this study may help planning collective health actions, giving an accurate description of the oral problems among the elderly.
Resumo:
OBJECTIVE: This in situ study evaluated the discriminatory power and reliability of methods of dental plaque quantification and the relationship between visual indices (VI) and fluorescence camera (FC) to detect plaque. MATERIAL AND METHODS: Six volunteers used palatal appliances with six bovine enamel blocks presenting different stages of plaque accumulation. The presence of plaque with and without disclosing was assessed using VI. Images were obtained with FC and digital camera in both conditions. The area covered by plaque was assessed. Examinations were done by two independent examiners. Data were analyzed by Kruskal-Wallis and Kappa tests to compare different conditions of samples and to assess the inter-examiner reproducibility. RESULTS: Some methods presented adequate reproducibility. The Turesky index and the assessment of area covered by disclosed plaque in the FC images presented the highest discriminatory powers. CONCLUSION: The Turesky index and images with FC with disclosing present good reliability and discriminatory power in quantifying dental plaque.
Resumo:
The biomechanics of the sacroiliac joint makes the pelvic segment responsible for proper weight distribution between lower extremities; however, it is known to be susceptible to altered mobility. The objective of this study was to analyze baropodometric responses following thrust manipulation on subjects with sacroiliac joint restrictions. Twenty asymptomatic subjects were submitted to computerized baropodometric analysis before, after, and seven days following sacroiliac manipulation. The variables peak pressure and contact area were obtained at each of these periods as the average of absolute values of the difference between the right and left foot based on three trials. Data revealed significant reduction only in peak pressure immediately after manipulation and at follow-up when compared to pre-manipulative values (p < 0.05). Strong correlation was found between the dominant foot and the foot with greater contact area (r - 0.978), as well as between the side of joint restriction and the foot with greater contact area (r = 0.884). Weak correlation was observed between the dominant foot and the foot with greater peak pressure (r = 0.501), as well as between the side of joint restriction and the foot with greater peak pressure (r = 0.694). The results suggest that sacroiliac joint manipulation can influence peak pressure distribution between feet, but contact area does not seem to be related to the biomechanical aspects addressed in this study. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)
Resumo:
RATIONALE: The aim of the work was to develop and validate a method for the quantification of vitamin D metabolites in serum using ultra-high-pressure liquid chromatography coupled to mass spectrometry (LC/MS), and to validate a high-resolution mass spectrometry (LC/HRMS) approach against a tandem mass spectrometry (LC/MS/MS) approach using a large clinical sample set. METHODS: A fast, accurate and reliable method for the quantification of the vitamin D metabolites, 25-hydroxyvitamin D2 (25OH-D2) and 25-hydroxyvitamin D3 (25OH-D3), in human serum was developed and validated. The C3 epimer of 25OH-D3 (3-epi-25OH-D3) was also separated from 25OH-D3. The samples were rapidly prepared via a protein precipitation step followed by solid-phase extraction (SPE) using an HLB μelution plate. Quantification was performed using both LC/MS/MS and LC/HRMS systems. RESULTS: Recovery, matrix effect, inter- and intra-day reproducibility were assessed. Lower limits of quantification (LLOQs) were determined for both 25OH-D2 and 25OH-D3 for the LC/MS/MS approach (6.2 and 3.4 µg/L, respectively) and the LC/HRMS approach (2.1 and 1.7 µg/L, respectively). A Passing & Bablok fit was determined between both approaches for 25OH-D3 on 662 clinical samples (1.11 + 1.06x). It was also shown that results can be affected by the inclusion of the isomer 3-epi-25OH-D3. CONCLUSIONS: Quantification of the relevant vitamin D metabolites was successfully developed and validated here. It was shown that LC/HRMS is an accurate, powerful and easy to use approach for quantification within clinical laboratories. Finally, the results here suggest that it is important to separate 3-epi-25OH-D3 from 25OH-D3. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
The objective of this study was to determine the inter- and intra-examiner reliability of pain pressure threshold algometry at various points of the abdominal wall of healthy women. Twenty-one healthy women in menacme with a mean age of 28 ± 5.4 years (range: 19-39 years) were included. All volunteers had regular menstrual cycles (27-33 days) and were right-handed and, to the best of our knowledge, none were taking medications at the time of testing. Women with a diagnosis of depression, anxiety or other mood disturbances were excluded. Women with previous abdominal surgery, any pain condition or any evidence of inflammation, hypertension, smoking, alcoholism, or inflammatory disease were also excluded. Pain perception thresholds were assessed with a pressure algometer with digital traction and compression and a measuring capacity for 5 kg. All points were localized by palpation and marked with a felt-tipped pen and each individual was evaluated over a period of 2 days in two consecutive sessions, each session consisting of a set of 14 point measurements repeated twice by two examiners in random sequence. There was no statistically significant difference in the mean pain threshold obtained by the two examiners on 2 diferent days (examiner A: P = 1.00; examiner B: P = 0.75; Wilcoxon matched pairs test). There was excellent/good agreement between examiners for all days and all points. Our results have established baseline values to which future researchers will be able to refer. They show that pressure algometry is a reliable measure for pain perception in the abdominal wall of healthy women.
Resumo:
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.
Resumo:
Introduction : L’expansion palatine rapide assistée chirurgicalement (EPRAC) est une option de traitement privilégiée chez les patients ayant atteint la maturité squelettique et présentant une déficience transverse du maxillaire. L’effet bénéfique de l’EPRAC sur la fonction respiratoire est régulièrement mentionné, toutefois, encore peu d’études ont évalué son impact sur les voies aériennes supérieures. L’objectif de cette étude clinique prospective comparative consistait à évaluer les effets tridimensionnels de l’EPRAC sur la cavité nasale, le nasopharynx et l’oropharynx à l’aide de la tomodensitométrie. Méthodologie : L’échantillon était constitué de 14 patients (5 hommes, 9 femmes) dont l’âge moyen était de 23,0 ± 1,9 ans (16 ans 4 mois à 39 ans 7 mois). Tous ont été traités avec un appareil d’expansion de type Hyrax collé et l’expansion moyenne a été de 9,82 mm (7,5 - 12,0 mm). Tous ont eu une période de contention d’une année avant le début de tout autre traitement orthodontique. Une évaluation par tomodensitométrie volumique à faisceau conique a été réalisée aux temps T0 (initial), T1 (6 mois post-expansion) et T2 (1an post-expansion) et le volume des fosses nasales, du nasopharynx et de l’oropharynx ainsi que les dimensions de la zone de constriction maximale de l’oropharynx ont été mesurés sur les volumes tridimensionnels obtenus. Résultats : Les résultats radiologiques ont démontré une augmentation significative du volume des fosses nasales et du nasopharynx ainsi qu’une augmentation de la zone de constriction maximale de l’oropharynx à 6 mois post-expansion. Par la suite, une portion du gain enregistré pour ces trois paramètres était perdue à un an post-EPRAC sans toutefois retourner aux valeurs initiales. Aucun effet significatif sur le volume de l’oropharynx n’a été observé. De plus, aucune corrélation significative entre la quantité d’expansion réalisée et l’ensemble des données radiologiques n’a été observée. L’analyse de la corrélation intra-classe a démontré une excellente fiabilité intra-examinateur. Conclusions : L’EPRAC entraîne un changement significatif du volume de la cavité nasale et du nasopharynx. L’EPRAC ne modifie pas le volume de l’oropharynx, par contre, un effet significatif sur la zone de constriction maximale de l’oropharynx est noté. Les effets observés n’ont pas de corrélation avec le montant d’activation de la vis d’expansion.
Resumo:
O objetivo do estudo foi analisar os índices CPOD, ceod, SiC Index e a porcentagem de crianças livres de cárie, em escolares de 5 a 12 anos da rede pública do Município de Bilac, São Paulo, Brasil, em estudos realizados nos anos de 1998, 2000, 2002 e 2004. Utilizou-se a mesma metodologia (OMS-1997) em todos os levantamentos. O teste estatístico kappa foi calculado a cada estudo, obtendo-se o valor de concordância interexaminadores mínimo de 0,86 e máximo de 0,89, e intra-examinador mínimo de 0,91. O índice ceod diminuiu pouco nos anos de 1998 e 2004. Houve uma redução contínua do índice CPOD aos 12 anos, passando de 5,28 em 1998 para 4,11 em 2000, 3,47 em 2002 e 2,62 em 2004, e o fenômeno da polarização. Na proporção inversa, a porcentagem de crianças com 5 anos livres de cárie aumentou de 37,9% em 1998 para 40% em 2000 e 2002, e 45,3% em 2004. Conclui-se que está ocorrendo a redução da cárie dentária na faixa etária de 12 anos entre escolares do ensino público do município.