995 resultados para Internal Dose
Resumo:
The study was to determine if breast cancer patients aged 65 and above could be given adjuvant chemotherapy safely while achieving an acceptable relative dose intensity of at least 85%. We identified all patients aged 65 and over who received adjuvant chemotherapy over the 10 year period, November 1999 to October 2009, and determined the proportion that achieved a relative dose intensity of at least 85% as well as the tolerability of their treatment. A total of 101 patients were identified, with a median age of 69 years (range 65-78).Of these, 25.7% of patients had at least one major comorbidity, 84.2% had a tumor size of 5 cm or less, 73.3% were node positive and 58.4% were hormone receptor positive. The chemotherapy regimens used were AC (Doxorubicin and Cyclophosphamide), FEC (Fluorouracil, Epirubicin, and Cyclophosphamide), CMF (Cyclophosphamide, Methotrexate, and Fluorouracil) and ECMF (Epirubicin followed by CMF). Seventy-nine patients (78.2%) achieved the relative dose intensity of at least 85%. With respect to toxicity, 11.9% of patients developed febrile neutropenia and 23.8% of patients required hospital admission during the treatment period, but there were no treatment-related deaths in the group. A significant proportion of patients aged 65 and above achieved the intended dose intensity of at least 85% over this 10-year period, with manageable toxicity levels. This supports the use of these regimens as adjuvant chemotherapy for breast cancer in this age group. © 2011 Wiley Periodicals, Inc.
Resumo:
Coal contains trace elements and naturally occurring radionuclides such as 40K, 232Th, 238U. When coal is burned, minerals, including most of the radionuclides, do not burn and concentrate in the ash several times in comparison with their content in coal. Usually, a small fraction of the fly ash produced (2-5%) is released into the atmosphere. The activities released depend on many factors (concentration in coal, ash content and inorganic matter of the coal, combustion temperature, ratio between bottom and fly ash, filtering system). Therefore, marked differences should be expected between the by-products produced and the amount of activity discharged (per unit of energy produced) from different coal-fired power plants. In fact, the effects of these releases on the environment due to ground deposition have been received some attention but the results from these studies are not unanimous and cannot be understood as a generic conclusion for all coal-fired power plants. In this study, the dispersion modelling of natural radionuclides was carried out to assess the impact of continuous atmospheric releases from a selected coal plant. The natural radioactivity of the coal and the fly ash were measured and the dispersion was modelled by a Gaussian plume estimating the activity concentration at different heights up to a distance of 20 km in several wind directions. External and internal doses (inhalation and ingestion) and the resulting risk were calculated for the population living within 20 km from the coal plant. In average, the effective dose is lower than the ICRP’s limit and the risk is lower than the U.S. EPA’s limit. Therefore, in this situation, the considered exposure does not pose any risk. However, when considering the dispersion in the prevailing wind direction, these values are significant due to an increase of 232Th and 226Ra concentrations in 75% and 44%, respectively.
Resumo:
Des efforts de recherche considérables ont été déployés afin d'améliorer les résultats de traitement de cancers pulmonaires. L'étude de la déformation de l'anatomie du patient causée par la ventilation pulmonaire est au coeur du processus de planification de traitement radio-oncologique. À l'aide d'images de tomodensitométrie quadridimensionnelles (4DCT), une simulation dosimétrique peut être calculée sur les 10 ensembles d'images du 4DCT. Une méthode doit être employée afin de recombiner la dose de radiation calculée sur les 10 anatomies représentant une phase du cycle respiratoire. L'utilisation de recalage déformable d'images (DIR), une méthode de traitement d'images numériques, génère neuf champs vectoriels de déformation permettant de rapporter neuf ensembles d'images sur un ensemble de référence correspondant habituellement à la phase d'expiration profonde du cycle respiratoire. L'objectif de ce projet est d'établir une méthode de génération de champs de déformation à l'aide de la DIR conjointement à une méthode de validation de leur précision. Pour y parvenir, une méthode de segmentation automatique basée sur la déformation surfacique de surface à été créée. Cet algorithme permet d'obtenir un champ de déformation surfacique qui décrit le mouvement de l'enveloppe pulmonaire. Une interpolation volumétrique est ensuite appliquée dans le volume pulmonaire afin d'approximer la déformation interne des poumons. Finalement, une représentation en graphe de la vascularisation interne du poumon a été développée afin de permettre la validation du champ de déformation. Chez 15 patients, une erreur de recouvrement volumique de 7.6 ± 2.5[%] / 6.8 ± 2.1[%] et une différence relative des volumes de 6.8 ± 2.4 [%] / 5.9 ± 1.9 [%] ont été calculées pour le poumon gauche et droit respectivement. Une distance symétrique moyenne 0.8 ± 0.2 [mm] / 0.8 ± 0.2 [mm], une distance symétrique moyenne quadratique de 1.2 ± 0.2 [mm] / 1.3 ± 0.3 [mm] et une distance symétrique maximale 7.7 ± 2.4 [mm] / 10.2 ± 5.2 [mm] ont aussi été calculées pour le poumon gauche et droit respectivement. Finalement, 320 ± 51 bifurcations ont été détectées dans le poumons droit d'un patient, soit 92 ± 10 et 228 ± 45 bifurcations dans la portion supérieure et inférieure respectivement. Nous avons été en mesure d'obtenir des champs de déformation nécessaires pour la recombinaison de dose lors de la planification de traitement radio-oncologique à l'aide de la méthode de déformation hiérarchique des surfaces. Nous avons été en mesure de détecter les bifurcations de la vascularisation pour la validation de ces champs de déformation.
Resumo:
The incidence of breast cancer has risen worldwide to unprecedented levels in recent decades, making it now the major cancer of women in many parts of the world.1 Although diet, alcohol, radiation and inherited loss of BRCA1/2 genes have all been associated with increased incidence, the main identified risk factors are life exposure to hormones including physiological variations associated with puberty/pregnancy/menopause,1 personal choice of use of hormonal contraceptives2 and/or hormone replacement therapy.3–6 On this basis, exposure of the human breast to the many environmental pollutant chemicals capable of mimicking or interfering with oestrogen action7 should also be of concern.8 Hundreds of such environmental chemicals have now been measured in human breast tissue from a range of dietary and domestic exposure sources7 ,9 including persistent organochlorine pollutants (POPs),10 polybrominated diphenylethers and polybromobiphenyls,11 polychlorinated biphenyls,12 dioxins,13 alkyl phenols,14 bisphenol-A and chlorinated derivatives,15 as well as other less lipophilic compounds such as parabens (alkyl esters of p-hydroxybenzoic acid),16 but studies investigating any association between raised levels of such compounds and the development of breast cancer remain inconclusive.7–16 However, the functionality of these chemicals has continued to be assessed on the basis of individual chemicals rather than the environmental reality of long-term low-dose exposure to complex mixtures. This misses the potential for individuals to have high concentrations of different compounds but with a common mechanism of action. It also misses the complex interactions between chemicals and physiological hormones which together may act to alter the internal homeostasis of the oestrogenic environment of mammary tissue.
Resumo:
The importance of thrombosis and anticoagulation in clinical practice is rooted firmly in several fundamental constructs that can be applied both broadly and globally. Awareness and the appropriate use of anticoagulant therapy remain the keys to prevention and treatment. However, to assure maximal efficacy and safety, the clinician must, according to the available evidence, choose the right drug, at the right dose, for the right patient, under the right indication, and for the right duration of time. The first International Symposium of Thrombosis and Anticoagulation in Internal Medicine was a scientific program developed by clinicians for clinicians. The primary objective of the meeting was to educate, motivate and inspire internists, cardiologists and hematologists by convening national and international visionaries, thought-leaders and dedicated clinician-scientists in Sao Paulo, Brazil. This article is a focused summary of the symposium proceedings. © Springer Science+Business Media, LLC 2009.
Resumo:
Due the differences between interaction physics process with matter for protons and photons, the proton beam tomography (pCT) has some vantages to comparison with conventional tomography. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. The pCT allow not only view the internal structure of an object without destroying it, but also directly measure of volume density of electrons. Also it is confirmed that usually pCT has better dose distribution and highest contrast resolution. At the same time, there are many scientific and technical aspects to a detailed study: the capacity and limitations of the pCT methods are not well clarified. Through computations, based on Monte Carlo Method was carried out a detailed study of the contribution of non-elastic nuclear spreading, and together was compared with an analytical model for the deflection angle and the lateral deflection of protons in the target volume. The programs used were SRIM 2006 code and MCNPX v.2.50 code
Resumo:
PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.
Meta-analysis: diagnostic performance of low-radiation-dose coronary computed tomography angiography
Resumo:
A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available.
Resumo:
BACKGROUND: A single high loading dose of 25 mg/kg caffeine has been shown to be effective for the prevention of apnoea, but may result in considerable reductions in blood flow velocity (BFV) in cerebral and intestinal arteries. OBJECTIVE: To assess the effects of two loading doses of 12.5 mg/kg caffeine given four hours apart on BFV in cerebral and intestinal arteries, left ventricular output (LVO), and plasma caffeine concentrations in preterm infants. DESIGN: Sixteen preterm neonates of <34 weeks gestation were investigated one hour after the first oral dose and one, two, and 20 hours after the second dose by Doppler sonography. RESULTS: The mean (SD) plasma caffeine concentrations were 31 (7) and 29 (7) mg/l at two and 20 hours respectively after the second dose. One hour after the first dose, none of the circulatory variables had changed significantly. One hour after the second caffeine dose, mean BFV in the internal carotid artery and anterior cerebral artery showed significant reductions of 17% and 19% (p = 0.01 and p = 0.003 respectively). BFV in the coeliac artery and superior mesenteric artery, LVO, PCO2, and respiratory rate had not changed significantly. Total vascular resistance, calculated as the ratio of mean blood pressure to LVO, had increased significantly one and two hours after the second dose (p = 0.049 and p = 0.023 respectively). CONCLUSION: A divided high loading dose of 25 mg/kg caffeine given four hours apart had decreased BFV in cerebral arteries after the second dose, whereas BFV in intestinal arteries and LVO were not affected.
Resumo:
Bone marrow ablation, i.e., the complete sterilization of the active bone marrow, followed by bone marrow transplantation (BMT) is a comment treatment of hematological malignancies. The use of targeted bone-seeking radiopharmaceuticals to selectively deliver radiation to the adjacent bone marrow cavities while sparing normal tissues is a promising technique. Current radiopharmaceutical treatment planning methods do not properly compensate for the patient-specific variable distribution of radioactive material within the skeleton. To improve the current method of internal dosimetry, novel methods for measuring the radiopharmaceutical distribution within the skeleton were developed. 99mTc-MDP was proven as an adequate surrogate for measuring 166Ho-DOTMP skeletal uptake and biodistribution, allowing these measures to be obtained faster, safer, and with higher spatial resolution. This translates directly into better measurements of the radiation dose distribution within the bone marrow. The resulting bone marrow dose-volume histograms allow prediction of the patient disease response where conventional organ scale dosimetry failed. They indicate that complete remission is only achieved when greater than 90% of the bone marrow receives at least 30 Gy. ^ Comprehensive treatment planning requires combining target and non-target organ dosimetry. Organs in the urinary tract were of special concern. The kidney dose is primarily dependent upon the mean transit time of 166 Ho-DOTMP through the kidney. Deconvolution analysis of renograms predicted a mean transit time of 2.6 minutes for 166Ho-DOTMP. The radiation dose to the urinary bladder wall is dependent upon numerous factors including patient hydration and void schedule. For beta-emitting isotopes such as 166Ho, reduction of the bladder wall dose is best accomplished through good patient hydration and ensuring a partially full bladder at the time of injection. Encouraging the patient to void frequently, or catheterizing the patient without irrigation, will not significantly reduce the bladder wall dose. ^ The results from this work will produce the most advanced treatment planning methodology for bone marrow ablation therapy using radioisotopes currently available. Treatments can be tailored specifically for each patient, including the addition of concomitant total body irradiation for patients with unfavorable dose distributions, to deliver a desired patient disease response, while minimizing the dose or toxicity to non-target organs. ^
Resumo:
The electron pencil-beam redefinition algorithm (PBRA) of Shiu and Hogstrom has been developed for use in radiotherapy treatment planning (RTP). Earlier studies of Boyd and Hogstrom showed that the PBRA lacked an adequate incident beam model, that PBRA might require improved electron physics, and that no data existed which allowed adequate assessment of the PBRA-calculated dose accuracy in a heterogeneous medium such as one presented by patient anatomy. The hypothesis of this research was that by addressing the above issues the PBRA-calculated dose would be accurate to within 4% or 2 mm in regions of high dose gradients. A secondary electron source was added to the PBRA to account for collimation-scattered electrons in the incident beam. Parameters of the dual-source model were determined from a minimal data set to allow ease of beam commissioning. Comparisons with measured data showed 3% or better dose accuracy in water within the field for cases where 4% accuracy was not previously achievable. A measured data set was developed that allowed an evaluation of PBRA in regions distal to localized heterogeneities. Geometries in the data set included irregular surfaces and high- and low-density internal heterogeneities. The data was estimated to have 1% precision and 2% agreement with accurate, benchmarked Monte Carlo (MC) code. PBRA electron transport was enhanced by modeling local pencil beam divergence. This required fundamental changes to the mathematics of electron transport (divPBRA). Evaluation of divPBRA with the measured data set showed marginal improvement in dose accuracy when compared to PBRA; however, 4% or 2mm accuracy was not achieved by either PBRA version for all data points. Finally, PBRA was evaluated clinically by comparing PBRA- and MC-calculated dose distributions using site-specific patient RTP data. Results show PBRA did not agree with MC to within 4% or 2mm in a small fraction (<3%) of the irradiated volume. Although the hypothesis of the research was shown to be false, the minor dose inaccuracies should have little or no impact on RTP decisions or patient outcome. Therefore, given ease of beam commissioning, documentation of accuracy, and calculational speed, the PBRA should be considered a practical tool for clinical use. ^
Resumo:
Background: It is essential for health-care professionals to calculate drug doses accurately. Previous studies have demonstrated that many hospital doctors were unable to accurately convert dilutions (e.g. 1:1000) or percentages (e.g. percentage w/v) of drug concentrations into mass concentrations (e.g. mg/mL). Aims: The aims of the present study were to evaluate the ability of health-care professionals to perform drug dose calculations accurately and to determine their preferred concentration convention when calculating drug doses. Methods: A selection of nurses, medical students, house surgeons, registrars and pharmacists undertook a written survey to assess their ability to perform five drug dose calculations. Participants were also asked which concentration convention they preferred when calculating drug doses. The surveys were marked then analysed for health-care professionals as a whole and then by subgroup analysis to assess the performance of each health-care-professional group. Results: Overall, less than 14% of the surveyed health-care professionals could answer all five questions correctly. Subgroup analysis revealed that health-care pro-fessionals' ability to calculate drug doses were ranked in the following order: registrars approximate to pharmacists > house surgeons > medical students >> nurses. Ninety per cent of health-care professionals preferred to calculate drug doses using the mass concentration convention. Conclusions: Overall, drug dose calculations were performed poorly. Mass concentration was clearly indicated as the preferred convention for calculating drug doses.
Resumo:
Background: Asthma guidelines recommend increasing or doubling inhaled corticosteroid (ICS) dose to treat mild and moderate exacerbations of asthma in adults. Aim: To: (i) compare the effectiveness of doubling existing daily ICS dose (fluticasone) with maintaining usual ICS dose and usual daily ICS dose accompanied by oral steroids (OS) (dexamethasone) during mild and moderately severe exacerbations of asthma in adults; (ii) examine determinants of success and failure; and (iii) compare side-effect profiles. Methods: A randomized, double-blind, placebo-controlled (double-dummy), triple crossover trial. Participants acted as their own control. Outcome measures included treatment success/failure, peak expiratory flow (PEF) after 7 days therapy or at treatment failure, and side-effects. Results: From 22 participants (nine males and 13 females), 18 pairs of data were available for maintaining usual ICS versus doubling ICS and doubling ICS versus OS, and 19 for maintaining usual ICS versus OS. Median (fifth-95th percentile) age was 46.5 (32-64) years and forced expiratory volume in one second (FEV1) 73% (29-97%) predicted. The outcome after doubling ICS was not superior to maintaining usual ICS, with 11 (61%) failures in both arms (P = 0.66). OS, with only 5 (26%) failures, was superior to maintaining usual ICS with 12 (63%) failures (P = 0.04), and to doubling ICS with 5 (28%) versus 11 (61%) failures (P = 0.07). Median PEF (as percentage of run-in best) at end-points were 90.5% (57.1-177.1) for OS, 78.3% (39.5-103.1) for maintaining usual ICS and 77.9 (27.7-110.3) for doubling ICS. Neither gender nor PEF at exacerbation were predictive of failure. Although doubling ICS was not an effective therapy overall, ICS dose at exacerbation were predictive of success in the doubling ICS arm (P = 0.04). Treatment failures when doubling daily ICS dose were more common if achieved fluticasone dose was less than 2000 mu g (three of 11, 73%) compared to 2000 mu g or greater (eight of eight, 37.5%). Increasing age and the presence of an upper respiratory tract infection (URTI) were predictive of failure with OS. Side-effects were more commonly reported with OS (52.6%) than doubling ICS (42.1%) or maintaining usual ICS (19.1%) with the most common being mood changes (36.8%), sleep disturbance (31.6%) and changes in appetite (26.3%). Conclusions: Doubling daily ICS dose per se is not effective for the treatment of mild to moderately severe exacerbations of asthma in adults. Success may depend on achieved ICS dose. Oral steroids are effective, but side-effects are common. A review of current guidelines may be warranted.