978 resultados para Institutional Review Boards


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To perform in vivo imaging of the cerebellum with an in-plane resolution of 120 mm to observe its cortical granular and molecular layers by taking advantage of the high signal-to-noise ratio and the increased magnetic susceptibility-related contrast available at high magnetic field strength such as 7 T. Materials and Methods: The study was approved by the institutional review board, and all patients provided written consent. Three healthy persons (two men, one woman; mean age, 30 years; age range, 28-31 years) underwent MR imaging with a 7-T system. Gradient-echo images (repetition time msec/echo time msec, 1000/25) of the human cerebellum were acquired with a nominal in-plane resolution of approximately 120 mum and a section thickness of 1 mm. Results: Structures with dimensions as small as 240 mum, such as the granular and molecular layers in the cerebellar cortex, were detected in vivo. The detection of these structures was confirmed by comparing the contrast obtained on T2*-weighted and phase images with that obtained on images of rat cerebellum acquired at 14 T with 30 mum in-plane resolution. Conclusion: In vivo cerebellar imaging at near-microscopic resolution is feasible at 7 T. Such detailed observation of an anatomic area that can be affected by a number of neurologic and psychiatric diseases, such as stroke, tumors, autism, and schizophrenia, could potentially provide newer markers for diagnosis and follow-up in patients with such pathologic conditions. (c) RSNA, 2010.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate the technical quality and the diagnostic performance of a protocol with use of low volumes of contrast medium (25 mL) at 64-detector spiral computed tomography (CT) in the diagnosis and management of adult, nontraumatic subarachnoid hemorrhage (SAH). MATERIALS AND METHODS: This study was performed outside the United States and was approved by the institutional review board. Intracranial CT angiography was performed in 73 consecutive patients with nontraumatic SAH diagnosed at nonenhanced CT. Image quality was evaluated by two observers using two criteria: degree of arterial enhancement and venous contamination. The two independent readers evaluated diagnostic performance (lesion detection and correct therapeutic decision-making process) by using rotational angiographic findings as the standard of reference. Sensitivity, specificity, and positive and negative predictive values were calculated for patients who underwent CT angiography and three-dimensional rotational angiography. The intraclass correlation coefficient was calculated to assess interobserver concordance concerning aneurysm measurements and therapeutic management. RESULTS: All aneurysms were detected, either ruptured or unruptured. Arterial opacification was excellent in 62 cases (85%), and venous contamination was absent or minor in 61 cases (84%). In 95% of cases, CT angiographic findings allowed optimal therapeutic management. The intraclass correlation coefficient ranged between 0.93 and 0.95, indicating excellent interobserver agreement. CONCLUSION: With only 25 mL of iodinated contrast medium focused on the arterial phase, 64-detector CT angiography allowed satisfactory diagnostic and therapeutic management of nontraumatic SAH.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Iowa Child Advocacy Board (ICAB) is an independent board composed of nine members appointed by the Governor of Iowa and confirmed by the Iowa Senate. ICAB establishes policies and procedures for two volunteer child advocacy programs: the Court Appointed Special Advocate (CASA) program and the Iowa Citizen Foster Care Review Boards programs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Iowa Child Advocacy Board (ICAB) is an independent board composed of nine members appointed by the Governor of Iowa and confirmed by the Iowa Senate. ICAB establishes policies and procedures for two volunteer child advocacy programs: the Court Appointed Special Advocate (CASA) program and the Iowa Citizen Foster Care Review Boards programs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Iowa Child Advocacy Board (ICAB) is an independent board composed of nine members appointed by the Governor of Iowa and confirmed by the Iowa Senate. ICAB establishes policies and procedures for two volunteer child advocacy programs: the Court Appointed Special Advocate (CASA) program and the Iowa Citizen Foster Care Review Boards programs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Iowa Child Advocacy Board (ICAB) is an independent board composed of nine members appointed by the Governor of Iowa and confirmed by the Iowa Senate. ICAB establishes policies and procedures for two volunteer child advocacy programs: the Court Appointed Special Advocate (CASA) program and the Iowa Citizen Foster Care Review Boards programs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Iowa Child Advocacy Board (ICAB) is an independent board composed of nine members appointed by the Governor of Iowa and confirmed by the Iowa Senate. ICAB establishes policies and procedures for two volunteer child advocacy programs: the Court Appointed Special Advocate (CASA) program and the Iowa Citizen Foster Care Review Boards programs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Iowa Child Advocacy Board (ICAB) is an independent board composed of nine members appointed by the Governor of Iowa and confirmed by the Iowa Senate. ICAB establishes policies and procedures for two volunteer child advocacy programs: the Court Appointed Special Advocate (CASA) program and the Iowa Citizen Foster Care Review Boards programs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Iowa Child Advocacy Board (ICAB) is an independent board composed of nine members appointed by the Governor of Iowa and confirmed by the Iowa Senate. ICAB establishes policies and procedures for two volunteer child advocacy programs: the Court Appointed Special Advocate (CASA) program and the Iowa Citizen Foster Care Review Boards programs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To assess the accuracy of a semiautomated 3D volume reconstruction method for organ volume measurement by postmortem MRI. METHODS: This prospective study was approved by the institutional review board and the infants' parents gave their consent. Postmortem MRI was performed in 16 infants (1 month to 1 year of age) at 1.5 T within 48 h of their sudden death. Virtual organ volumes were estimated using the Myrian software. Real volumes were recorded at autopsy by water displacement. The agreement between virtual and real volumes was quantified following the Bland and Altman's method. RESULTS: There was a good agreement between virtual and real volumes for brain (mean difference: -0.03% (-13.6 to +7.1)), liver (+8.3% (-9.6 to +26.2)) and lungs (+5.5% (-26.6 to +37.6)). For kidneys, spleen and thymus, the MRI/autopsy volume ratio was close to 1 (kidney: 0.87±0.1; spleen: 0.99±0.17; thymus: 0.94±0.25), but with a less good agreement. For heart, the MRI/real volume ratio was 1.29±0.76, possibly due to the presence of residual blood within the heart. The virtual volumes of adrenal glands were significantly underestimated (p=0.04), possibly due to their very small size during the first year of life. The percentage of interobserver and intraobserver variation was lower or equal to 10%, but for thymus (15.9% and 12.6%, respectively) and adrenal glands (69% and 25.9%). CONCLUSIONS: Virtual volumetry may provide significant information concerning the macroscopic features of the main organs and help pathologists in sampling organs that are more likely to yield histological findings.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Ependymoma is a rare type of glioma, representing 5% of all CNS malignancies. Radiotherapy (RT) is commonly administered, but there is no standard chemotherapy. At recurrence, ependymoma is notoriously refractory to therapy and the prognosis is poor. In recurrent glioblastoma, encouraging responses with bevacizumab have been observed. METHODS: In this Institutional Review Board-approved study, we retrospectively analyzed the records of 8 adult patients treated for recurrent ependymoma and anaplastic ependymoma with bevacizumab containing chemotherapy regimens. We determined radiographic response (Macdonald criteria), median time to progression (TTP), and median overall survival (OS; Kaplan-Meier method). RESULTS: There were 4 men and 4 women with a median age of 40 years (range, 20-65). Prior treatment included surgery (n = 8), RT (8), temozolomide (5), and carboplatin (4). Bevacizumab (5-15 mg/kg every 2-3 weeks) was administered alone (2) or concurrently with cytotoxic chemotherapy including irinotecan (3), carboplatin (2), or temozolomide (1). Six patients achieved a partial response (75%) and 1 remained stable for over 8 months. Median TTP was 6.4 months (95% confidence interval 1.4-7.4) and median OS was 9.4 months (95% confidence interval 7.0-not reached), with a median follow-up of 5.2 months among 5 surviving patients (63%). CONCLUSIONS: The radiographic response rate to bevacizumab-containing regimens is high. A prospective study is warranted.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to prospectively use a whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography technique specifically adapted for use at 3 T and a parallel imaging technique (sensitivity encoding) to evaluate coronary arterial anomalies and variants (CAAV). This HIPAA-compliant study was approved by the local institutional review board, and informed consent was obtained from all participants. Twenty-two participants (11 men, 11 women; age range, 18-62 years) were included. Ten participants were healthy volunteers, whereas 12 participants were patients suspected of having CAAV. Coronary MR angiography was performed with a 3-T MR imager. A 3D free-breathing navigator-gated and vector electrocardiographically-gated segmented k-space gradient-echo sequence with adiabatic T2 preparation pulse and parallel imaging (sensitivity encoding) was used. Whole-heart acquisitions (repetition time msec/echo time msec, 4/1.35; 20 degrees flip angle; 1 x 1 x 2-mm acquired voxel size) lasted 10-12 minutes. Mean examination time was 41 minutes +/- 14 (standard deviation). Findings included aneurysms, ectasia, arteriovenous fistulas, and anomalous origins. The 3D whole-heart acquisitions developed for use with 3 T are feasible for use in the assessment of CAAV.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To compare qualitative and quantitative magnetic resonance (MR) imaging characteristics of hepatic hemangiomas in patients with normal, fibrotic and cirrhotic livers. MATERIALS AND METHODS: Retrospective, institutional review board approved study (waiver of informed consent). Eighty-nine consecutive patients with 231 hepatic hemangiomas who underwent liver MR imaging for lesion characterization were included. Lesions were classified into three groups according to the patients' liver condition: no underlying liver disease (group 1), fibrosis (group 2) and cirrhosis (group 3). Qualitative and quantitative characteristics (number, size, signal intensities on T1-, T2-, and DW MR images, T2 shine-through effect, enhancement patterns (classical, rapidly filling, delayed filling), and ADC values) were compared. RESULTS: There were 160 (69%), 45 (20%), and 26 (11%) hemangiomas in groups 1, 2 and 3, respectively. Lesions were larger in patients with normal liver (group 1 vs. groups 2 and 3; P=.009). No difference was found between the groups on T2-weighted images (fat-suppressed fast spin-echo (P=.82) and single-shot (P=.25)) and in enhancement patterns (P=.56). Mean ADC values of hemangiomas were similar between groups 1, 2 and 3 (2.11±.52×10(-3)mm(2)/s, 2.1±.53×10(-3)mm(2)/s and 2.14±.44×10(-3)mm(2)/s, P=87, respectively). T2 shine-through effect was less frequently observed in cirrhosis (P=.02). CONCLUSION: MR imaging characteristics of hepatic hemangioma were similar in patients with normal compared to fibrotic and cirrhotic livers. Smaller lesion size was observed with liver disease and less T2 shine-through effect was seen in hemangiomas developed on cirrhosis, the latter being an important finding to highlight in these patients at risk of developing hepatocellular carcinoma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Cerebral palsy (CP) is the most common physical disability in childhood. It is a disorder resulting from sensory and motor impairments due to perinatal brain injury, with lifetime consequences that range from poor adaptive and social function to communication and emotional disturbances. Infants with CP have a fundamental disadvantage in recovering motor function: they do not receive accurate sensory feedback from their movements, leading to developmental disregard. Constraint-induced movement therapy (CIMT) is one of the few effective neurorehabilitative strategies shown to improve upper extremity motor function in adults and older children with CP, potentially overcoming developmental disregard. METHODS AND ANALYSIS: This study is a randomised controlled trial of children 12-24 months corrected age studying the effectiveness of CIMT combined with motor and sensory-motor interventions. The study population will comprise 72 children with CP and 144 typically developing children for a total of N=216 children. All children with CP, regardless of group allocation will continue with their standard of care occupational and physical therapy throughout the study. The research material collected will be in the form of data from high-density array event-related potential scan, standardised assessment scores and motion analysis scores. ETHICS AND DISSEMINATION: The study protocol was approved by the Institutional Review Board. The findings of the trial will be disseminated through peer-reviewed journals and scientific conferences. TRIAL REGISTRATION NUMBER: NCT02567630.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En salle d’opération, les tâches de l’anesthésiste sont nombreuses. Alors que l’utilisation de nouveaux outils technologiques l’informe plus fidèlement sur ce qui se passe pour son patient, ces outils font que ses tâches deviennent plus exigeantes. En vue de diminuer cette charge de travail, nous avons considérer l’administration automatique d’agents anesthésiques en se servant de contrôle en boucle fermée. À cette fin, nous avons développé un système d’administration d’un agent anesthésique (le propofol) visant à maintenir à un niveau optimal la perte de conscience du patient pendant toute la durée d’une chirurgie. Le système comprend un ordinateur, un moniteur d’anesthésie et une pompe de perfusion. L’ordinateur est doté d’un algorithme de contrôle qui, à partir d’un indice (Bispectral IndexTM ou BIS) fournit par le moniteur d’anesthésie détermine le taux d’infusion de l’agent anesthésiant. Au départ, l’anesthésiste choisit une valeur cible pour la variable de contrôle BIS et l’algorithme, basé sur système expert, calcule les doses de perfusion de propofol de sorte que la valeur mesurée de BIS se rapproche le plus possible de la valeur cible établie. Comme interface-utilisateur pour un nouveau moniteur d’anesthésie, quatre sortes d’affichage ont été considérés: purement numérique, purement graphique, un mélange entre graphique et numérique et un affichage graphique intégré (soit bidimensionnel). À partir de 20 scenarios différents où des paramètres normaux et anormaux en anesthésie étaient présentés à des anesthésistes et des résidents, l’étude des temps de réaction, de l’exactitude des réponses et de la convivialité (évaluée par le NASA-TLX) a montré qu’un affichage qui combine des éléments graphiques et numériques était le meilleur choix comme interface du système. Une étude clinique a été réalisée pour comparer le comportement du système d’administration de propofol en boucle fermée comparativement à une anesthésie contrôlée de façon manuelle et conventionnelle où le BIS était aussi utilisé. Suite à l’approbation du comité d’éthique et le consentement de personnes ayant à subir des chirurgies générales et orthopédiques, 40 patients ont été distribués également et aléatoirement soit dans le Groupe contrôle, soit dans le Groupe boucle fermée. Après l’induction manuelle de propofol (1.5 mg/kg), le contrôle en boucle fermée a été déclenché pour maintenir l’anesthésie à une cible de BIS fixée à 45. Dans l’autre groupe, le propofol a été administré à l’aide d’une pompe de perfusion et l’anesthésiste avait aussi à garder manuellement l’indice BIS le plus proche possible de 45. En fonction du BIS mesuré, la performance du contrôle exercé a été définie comme excellente pendant les moments où la valeur du BIS mesurée se situait à ±10% de la valeur cible, bonne si comprise de ±10% à ±20%, faible si comprise de ±20% à ±30% ou inadéquate lorsque >±30%. Dans le Groupe boucle fermée, le système a montré un contrôle excellent durant 55% du temps total de l’intervention, un bon contrôle durant 29% du temps et faible que pendant 9% du temps. Le temps depuis l’arrêt de la perfusion jusqu’à l’extubation est de 9 ± 3.7 min. Dans le Groupe contrôle, un contrôle excellent, bon, et faible a été enregistré durant 33%, 33% et 15% du temps respectivement et les doses ont été changées manuellement par l’anesthésiste en moyenne 9.5±4 fois par h. L’extubation a été accomplie après 11.9 ± 3.3 min de l’arrêt de la perfusion. Dans le Groupe boucle fermée, un contrôle excellent a été obtenu plus longtemps au cours des interventions (P<0.0001) et un contrôle inadéquat moins longtemps (P=0.001) que dans le Groupe contrôle. Le système en boucle fermée d’administration de propofol permet donc de maintenir plus facilement l’anesthésie au voisinage d’une cible choisie que l’administration manuelle.