50 resultados para Inmetro
Resumo:
During a petroleum well production process, It is common the slmultaneous oil and water production, in proportion that can vary from 0% up to values close to 100% of water. Moreover, the production flows can vary a lot, depending on the charaeteristies of eaeh reservoir. Thus being, the meters used in field for the flow and BSW (water in the oil) measurement must work well in wide bands of operation. For the evaluation of the operation of these meters, in the different operation conditions, a Laboratory will be built in UFRN, that has for objective to evaluate in an automatic way the processes of flow and BSW petroleum measurement, considering different operation conditions. The good acting of these meters is fundamental for the accuracy of the measures of the volumes of production liquid and rude of petroleum. For the measurement of this production, the petroleum companies use meters that should indicate the values with tha largast possible accuracy and to respect a series of conditions and minimum requirements, estabelished by the united Entrance ANP/INMETRO 19106/2000. The laboratory of Evafuation of the Processes of Measurement of Flow and BSW to be built will possess an oil tank basically, a tank of water, besides a mixer, a tank auditor, a tank for separation and a tank of residues for discard of fluids, fundamental for the evaluation of the flow metars and BSW. The whole process will be automated through the use of a Programmable Logicat Controller (CLP) and of a supervisory system.This laboratory besides allowing the evaluation of flow meters and BSW used by petroleum companies, it will make possible the development of researches related to the automation. Besides, it will be a collaborating element to the development of the Computer Engineering and Automation Department, that it will propitiate the evolution of the faculty and discente, qualifying them for a job market in continuous growth. The present work describes the project of automation of the laboratory that will be built at of UFRN. The system will be automated using a Programmable Logical Controller and a supervisory system. The programming of PLC and the screens of the supervisory system were developed in this work
Resumo:
O principal objetivo deste trabalho é verificar, por meio de uma pesquisa tipo survey, os benefícios e as dificuldades da adoção de Sistemas de Gestão Ambiental ISO 14001 em empresas industriais do Estado de São Paulo. Para tal, um questionário foi enviado para 194 empresas constantes da base de dados do INMETRO (Instituto Nacional de Metrologia, Normalização e Qualidade Industrial) e respondido por 69 delas, representando uma taxa de retorno de 35,36%. Duas hipóteses foram estabelecidas para realização do estudo: uma enunciando os potenciais benefícios e outra as dificuldades da gestão ambiental com base na norma NBR ISO 14001. Estas hipóteses foram parcialmente comprovadas. O artigo está estruturado da seguinte forma: introdução, sistema de gestão ambiental, norma NBR ISO 14001, método de pesquisa, apresentação e análise dos resultados, conclusão e referências bibliográficas.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Química - IQ
Resumo:
The discussions about the energy rationalization are gaining more and more space on the everyday of engineers and other professionals in the field of energy. A greater focus is being tied to commercial buildings, because they are one of the biggest responsible for the high energetic expenditure according to the National Energetic Balance, especially by the use of air conditioners for the people’s thermal comfort. Such finding made INMETRO to develop a building labeling procedure through th National Program of Electric Energy Conservation in Buildings; by means of this systematic, the built areas are classified by levels that go from A(the best) to E(the worst), taking into account envelopment, illumination system and air conditioning. A bonus process based on water rationalization, use of renewable energy sources, cogeneration systems or technical innovations, allows the classification to be changed up to one level. A study made exactly on a commercial building, the building of Foundation for Technological and Scientific Development located inside of the College of Engineering of Guaratinguetá, sought to identify technical/economic alternatives for the building certification and appealed to the bonus based on water rationalization. The present study is based on analysis of deploying a cogeneration system formed by internal combustion engine and an absorption refrigeration system as bonus alternative, so that the costs are analyzed regarding energy consumption and use of the motor. With the calculations and results, the viability of the building to receive a bonus from INMETRO through its National Program for Energy Conservation in Buildings is studied and concluded from this study whether or not you can get a better level of energy efficiency for the building in question... (Complete abstract click electronic access below)
Resumo:
PURPOSE: to analyze the levels of noise emitted by nationally-sold toys for use by children from 1 to 5 year old; to compare the values among the toys with and without the seal of Inmetro (National Institute of Metrology, Standardization and Industrial Quality) and to analyze the sound spectrum of toys, in order to identify the area of the cochlea that may be more affected by these noises. METHOD: measurements were performed on 20 sound toys (10 with the seal of the Inmetro and 10 without the seal) with the use of digital sound level meter in an acoustically treated room, and the sound analysis was performed using the Praat program. RESULTS: toys placed at 2.5 cm from the equipment with the seal of the Inmetro had an intensity ranging from 61.50 to 91.55 dB (A) and from 69.75 to 95.05 dB (C), positioned at 25 cm ranged from 58.3 to 79.85 dB (A) and from 62.50 to 83.65 dB (C). The results of the toys without warranty stamps placed at 2.5 cm ranged from 67.45 to 94.30 dB (A) and 65.4 to 99.50 dB (C) and the distance of 25 cm recorded from 61. 30 to 87.45 dB (A) and 63.75 to 97.60 dB (C), so that the findings demonstrated that there are noisy toys that go beyond the values recommended by the current legislation in both groups, with and without warranty stamps . CONCLUSION: the toys without the seal of Inmetro showed intensities values significantly higher than the other group, offering more risk to the children s hearing health.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency`s technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.
Resumo:
In this paper, we discuss the effects of catalyst load with respect to carbon powder for several Pt and Pb-based catalysts, using formic acid as a model molecule. The discussion is based on electrochemical tests, a complete morphological investigation and theoretical calculations. We show that the Pt and Pb-based catalysts presented activity in formic acid oxidation at very low catalyst loads (e.g., 0.5% in respect to the carbon content). Physical characterisations demonstrate that the electrodes are composed of separated phases of Pt and lead distributed in Pt nanometric-sized islands that are heterogeneously dispersed on the carbon support and Pb ultra-small particles homogeneously distributed throughout the entire carbon surface, as demonstrated by the microscopy studies. At high catalyst loads, very large clusters of Pb(x)O(y) could be observed. Electrochemical tests indicated an increase in the apparent resistance of the system (by a factor of 19.7 Omega) when the catalyst load was increased. The effect of lead in the materials was also studied by theoretical calculations (OFT). The main conclusion is that the presence of Pb atoms in the catalyst can improve the adsorption of formic acid in the catalytic system compared with a pure Pt-based catalyst. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Neste artigo descreve-se uma pesquisa na qual se desenvolveu um analisador de desfibriladores e cardioversores e se executou sua avaliação metrológica, sendo apresentados os resultados obtidos. A avaliação das incertezas de medição do analisador foi realizada de acordo com as determinações da versão brasileira do EA-4/02 - Expressão da Incerteza de Medição de Calibração publicado pelo INMETRO. Os resultados obtidos mostraram-se adequados às exigências de exatidão determinadas pelas normas ANSI/AAMI DF2 (American..., 1996) e ANSI/AAMI DF80 (American..., 2003), tendo apresentado uma incerteza expandida relativa para as medições de energia igual a 1,0% no pior caso. Nesta pesquisa foi também realizada uma análise da incerteza definicional do processo de calibração utilizado e avaliou-se a capacidade do processo. Para os cálculos da capacidade do processo, foi determinado um erro máximo para as medições de energia igual a 5% ou 1,0 J, o que for maior. Este erro máximo é igual a 1/3 do erro máximo admissível para a energia entregue pelos desfibriladores, em outras palavras, é igual ao erro máximo admissível para um instrumento de medição pela Norma ANSI/AAMI DF2 (American..., 1996). Os resultados obtidos para a capacidade do procedimento de calibração mostraram-se adequados para as especificações de um analisador de desfibriladores e cardioversores, tendo obtido como resultado, no pior caso, um índice de capacidade Cm igual a 2,87, que é bem superior, portanto, a 1,0, sendo este o limite mínimo para que o procedimento seja considerado capaz de calibrar a medição de energia sem atribuir uma incerteza definicional demasiadamente grande.
Resumo:
A ciência e a tecnologia cada vez mais vêm proporcionando avanços em produtos inovadores. Particularmente na área da saúde nota-se eminente sinergismo entre os materiais utilizados, suas propriedades de biocompatibilidade, biofuncionalidade, processabilidade, esterilidade e a área de aplicabilidade no organismo humano. O setor farmacêutico por apresentar grande complexidade exige conhecimentos multidisciplinares, atualizados e em conformidade às tendências internacionais. A Agência Nacional de Vigilância Sanitária (ANVISA) tem sob sua responsabilidade extensa diversidade de bens, serviços e produtos, dentre eles estão os correlatos, que também compreende os produtos para saúde. Os produtos para saúde são classificados conforme o seu risco, no Brasil podendo apresentar até quatro classes, sendo as classes III e IV as que caracterizam maior risco. Para alguns produtos, devido seu risco sanitário, é compulsório a Certificação de Conformidade pelo Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO) previamente a concessão de seu registro sanitário pela ANVISA. Dentre as normas técnicas aplicáveis pelo INMETRO estão as normas da Associação Brasileira de Normas Técnicas (ABNT) e na sua ausência, as normas da International Organization for Standardization (ISO). Outros requisitos técnicos e regulatórios devem ser contemplados com o propósito de comprovação da segurança e eficácia dos produtos. Entretanto, as regulamentações sanitárias inerentes a essa categoria de produtos ainda se encontram incipientes no país. A desenvoltura do setor produtivo nesse segmento pode ser evidenciada pelo aumento de novas solicitações na ANVISA e de seu crescimento na balança comercial. No entanto, observa-se pouco estudo e entendimento do setor regulado e regulador referente à relação mútua entre ANVISA, INMETRO e ABNT e quanto à regulação sanitária aplicável para obtenção da anuência do produto ao consumo. Na conjuntura das demandas apontadas o objetivo deste estudo foi avaliar o processo regulatório aplicável à cadeia produtiva dos produtos para saúde com a finalidade de compreender a relação entre ANVISA, INMETRO e ABNT na garantia da qualidade, segurança e eficácia dos produtos. A metodologia aplicada neste trabalho foi à pesquisa qualitativa. Com o auxílio da pesquisa documental constatou-se que o processo regulatório brasileiro é complexo, específico e robusto e apresenta estrutura e exigências semelhantes dos Estados Unidos e União Europeia. A fiscalização pós-uso é uma tendência internacional e a ANVISA vem adotando com frequência com intuito de acompanhar a qualidade dos produtos comercializados. As três instituições apresentam competências definidas e regulamentadas, bem como mecanismos de inter-relação por meio de conselhos consultivos. O estudo de caso caracterizou que o perfil dos profissionais do setor regulado apresenta em grande percentual formação na área da saúde e nível de pós-graduação, porém o nível de conhecimento dos principais conceitos relativos aos produtos para saúde é parcial, reforçando a necessidade de incentivos de capacitação de recursos humanos em regulação em saúde.
Resumo:
O presente artigo tem como objetivo analisar as discussões entre dois stakeholders, a ÚNICA e o INMETRO sobre o processo de certificação do etanol no Brasil, pontuando seus benefícios e implicações nas áreas sociais, ambientais e econômicas. Para atender a esse objetivo foi realizada pesquisa bibliográfica, documental e entrevista com a ÚNICA e o INMETRO para verificar o processo de certificação do etanol. Os resultados apontam que as empresas brasileiras produtoras de etanol já adotam certificações que abrangem critérios ambientais e sociais de acordo com as exigências dos clientes. Mas o setor produtivo, juntamente com o Estado e outras organizações, vem buscando ações para criar padrões mundiais para o etanol, o que pode facilitar o processo de transformação do produto em uma commodity.
Resumo:
This study is an analysis, on a trial basis, the fuel consumption of a Flex vehicle, operating with different mixtures of gasoline and ethanol in urban traffic, allowing more consistent results with the reality of the driver. Considering that most owners unaware of the possibility of mixing the fuel at the time of supply, thus enabling the choice of the most economically viable mixing gasoline / ethanol, resulting in lower costs and possibly a decrease in pollutant emission rates. Currently, there is a myth created by the people that supply ethanol only becomes viable if the value of not more than 70% of regular gasoline. However vehicles with this technology make it possible to operate with any percentage of mixture in the fuel tank, but today many of the owners of these vehicles do not use this feature effectively, because they ignore the possibility of mixing or the reason there is a deeper study regarding the optimal percentage of the mixture to provide a higher yield with a lower cost than proposed by the manufacturers.