995 resultados para In-shoe orthoses
Resumo:
Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.
Resumo:
BACKGROUND: Complex foot and ankle fractures, such as calcaneum fractures or Lisfranc dislocations, are often associated with a poor outcome, especially in terms of gait capacity. Indeed, degenerative changes often lead to chronic pain and chronic functional limitations. Prescription footwear represents an important therapeutic tool during the rehabilitation process. Local Dynamic Stability (LDS) is the ability of locomotor system to maintain continuous walking by accommodating small perturbations that occur naturally during walking. Because it reflects the degree of control over the gait, LDS has been advocated as a relevant indicator for evaluating different conditions and pathologies. The aim of this study was to analyze changes in LDS induced by orthopaedic shoes in patients with persistent foot and ankle injuries. We hypothesised that footwear adaptation might help patients to improve gait control, which could lead to higher LDS: METHODS: Twenty-five middle-aged inpatients (5 females, 20 males) participated in the study. They were treated for chronic post-traumatic disabilities following ankle and/or foot fractures in a Swiss rehabilitation clinic. During their stay, included inpatients received orthopaedic shoes with custom-made orthoses (insoles). They performed two 30s walking trials with standard shoes and two 30s trials with orthopaedic shoes. A triaxial motion sensor recorded 3D accelerations at the lower back level. LDS was assessed by computing divergence exponents in the acceleration signals (maximal Lyapunov exponents). Pain was evaluated with Visual Analogue Scale (VAS). LDS and pain differences between the trials with standard shoes and the trials with orthopaedic shoes were assessed. RESULTS: Orthopaedic shoes significantly improved LDS in the three axes (medio-lateral: 10% relative change, paired t-test p < 0.001; vertical: 9%, p = 0.03; antero-posterior: 7%, p = 0.04). A significant decrease in pain level (VAS score -29%) was observed. CONCLUSIONS: Footwear adaptation led to pain relief and to improved foot & ankle proprioception. It is likely that that enhancement allows patients to better control foot placement. As a result, higher dynamic stability has been observed. LDS seems therefore a valuable index that could be used in early evaluation of footwear outcome in clinical settings.
Resumo:
Assessment of locomotion through simple tests such as timed up and go (TUG) or walking trials can provide valuable information for the evaluation of treatment and the early diagnosis of people with Parkinson's disease (PD). Common methods used in clinics are either based on complex motion laboratory settings or simple timing outcomes using stop watches. The goal of this paper is to present an innovative technology based on wearable sensors on-shoe and processing algorithm, which provides outcome measures characterizing PD motor symptoms during TUG and gait tests. Our results on ten PD patients and ten age-matched elderly subjects indicate an accuracy ± precision of 2.8 ± 2.4 cm/s and 1.3 ± 3.0 cm for stride velocity and stride length estimation compared to optical motion capture, with the advantage of being practical to use in home or clinics without any discomfort for the subject. In addition, the use of novel spatio-temporal parameters, including turning, swing width, path length, and their intercycle variability, was also validated and showed interesting tendencies for discriminating patients in ON and OFF states and control subjects.
Resumo:
Research is reported which attempted to identify construction procedures that will provide an improved centerline joint on asphalt concrete pavements. Various construction procedures and their evaluation are described. Core densities were made and visual inspections were made 3 years after construction. Center cracking was measured at 4, 5, and 6 years. The only procedure to rank the same when comparing cracking and density (delete the 1:1 slope shoe on the edge) is described. This procedure had the highest average density and also the least cracking through 1985. This method provided the best performance for 4 years after construction and involved the removal of the 1:1 slope shoe from the paver when placing the surface course. This method had 9.0% cracked after 4 years and 100% cracked after 6 years of service.
Resumo:
The effectiveness of water removal on press section is very important for a paper and board machine’s functioning, efficiency and economy. Today, the most effective method for wet pressing is shoe press technology. Metso has carried out a number of studies concerning anew type of water removal method for a press section, which has also been patented. These studies include rough sketches and some test runs. These issues form the basis of this thesis. The objective of this work was to gather together information for a new and enhanced waterremoval method for a press section by studying the functioning of the device andcarrying out test runs. This method is referred to here as Hydronip. The main goal was tobuild a functional test site which fulfills all the necessary requirements and has all thenecessary information gathering devices. The design process was carried out by emphasizing the safety aspects. The goal was also to gather together information about the nip structure in running conditions, the seal function, and to carry out the nip tests with paper or board wads. This thesis consists of a theory part, the design and construction of the test site, and carrying out test runs through information gathering. The theory part consists of the principals of water removal from a press section, Hydronip construction, and the requirements for the test place. The safety aspects were taken into account especially in test runs, but also in the assembly stages. The design and construction of the test site includes the selection of equipment and surroundings that are needed for managing the test runs in the best possible way at certain premises. The test site included the equipment that was already on the premises. Some equipment could be used as it was but some equipment had to be manufactured or modified from existing equipment. A functional test site with information gathering devices was accomplished as a result of thethesis. Test runs demonstrated that the Hydronip concept is, at least on a small scale,functional. Short-term tests for seal functioning showed that the seal can be lubricatedsufficiently under different kinds of nip load situations. Wad tests demonstrated that the metal belt is durable against different sizes of external particles. The seal also endured wad tests even though the pressure impacts impaired the lubrication. MTS tests showing dry content increases, combined with a rough cost calculation and the basic function of the machine in test runs, show that with some further study Hydronip could be a promising new product for water removal from a paper or board machine’s press section.
Resumo:
The objective of the present study was to propose an orthosis of light material that would be functional for the animal and that would maintain only the ankle joint immobilized. Male Wistar rats (3 to 4 months old, 250-300 g) were divided into 2 groups (N = 6): control and immobilized for 7 days. Rats were anesthetized with sodium pentobarbital (40 mg/kg weight) and the left hindlimb was immobilized with the orthoses composed of acrylic resin model, abdominal belt and lateral supports. The following analyses were performed: glycogen content of the soleus, extensor digitorum longus, white gastrocnemius, red gastrocnemius, and tibialis anterior muscles by the phenol sulfuric method, and the weight, fiber area and intramuscular connective tissue of the soleus by the planimetric system. Data were analyzed statistically by the Kolmogorov-Smirnov, Student t and Wilcoxon tests. Immobilization decreased glycogen in all muscles (P < 0.05; soleus: 31.6%, white gastrocnemius: 56.6%, red gastrocnemius: 39%, extensor digitorum longus: 41.7%, tibialis anterior: 45.2%) in addition to reducing soleus weight by 34% (P < 0.05). Furthermore, immobilization promoted reduction of the fiber area (43%, P < 0.05) and increased the connective tissue (200%, P < 0.05). The orthosis model was efficient comparing with another alternative immobilization model, like plaster casts, in promoting skeletal muscle alterations, indicating that it could be used as a new model in other studies related to muscle disuse.
Resumo:
Book contains meeting minutes of the Board of Directors of the Humberstone Shoe Company Ltd., held at the Office of McLeod, Young, Weir and Co. Limited, Metropolitan Building, Toronto. Board of Directors includes: H.H. Knoll (President), J.H. Radcliffe, E. K. Reiner, T.H. Kinnear, L.B. Spencer. There is some correspondence, annual reports, contracts, by-laws, statements of profit and loss etc. throughout the book.
Resumo:
The description on the reverse states "The Majesty and Beauty of Niagara. The Horse Shoe Fall." There is also a No. associated with the card, but the original printed number (5800_01) has been crossed out and replaced in ink with 5795.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: The aim of the present study was to evaluate the prevention and self-inspection behavior of diabetic subjects with foot at ulcer risk, no previous episode, who participated in the routine visits and standardized education provided by the service and who received prescribed footwear. This evaluation was carried out using a questionnaire scoring from 0-10 (high scores reflect worse practice compliance).Results: 60 patients were studied (30 of each sex); mean age was 62 years, mean duration of the disease was 17 years. As for compliance, 90% showed a total score <= 5, only 8.7% regularly wore the footwear supplied; self foot inspection 65%, 28,3% with additional familiar inspection; creaming 77%; proper washing and drying 88%; proper cutting of toe nails 83%; no cuticle cutting 83%; routine shoe inspection 77%; no use of pumice stones or similar abrasive 70%; no barefoot walking 95%.Conclusion: the planned and multidisciplinary educational approach enabled high compliance of the ulcer prevention care needed in diabetic patients at risk for complications. In contrast, compliance observed for the use of footwear provided was extremely low, demonstrating that the issue of its acceptability should be further and carefully addressed. In countries of such vast dimensions as Brazil multidisciplinary educational approaches can and should be performed by the services providing care for patients with foot at risk for complications according to the reality of local scenarios. Furthermore, every educational program should assess the learning, results obtained and efficacy in the target population by use of an adequate evaluation system.
Resumo:
The effects of Tissucol and Tissucol/EACA on bone healing were evaluated histologically. Experimental defects were made in both tibias of 25 rats. Test materials were placed in defects in right tibias and left tibias served as control. Five animals in each group were killed at 1, 3, 7, 14 and 21 days after surgery. Results showed that: a) Tissucol did not interfere with connective and osseous tissue formation; b) Tissucol allowed new bone formation; c) Tissue residues in Tissucol groups in sections of 21-day specimens did not impair healing; d) Tissucol/EACA was usually completely resorbed and healing was complete 21 days after surgery in the Tissucol/EACA group.
Resumo:
This research evaluated the bone repair process after implantation of homogenous demineralized dentin matrix (HDDM) in surgical defects in the parietal bone of rabbits with alloxan-induced diabetes, using a polytetrafluorethylene (PTFe) barrier for guided bone regeneration. Thirty-six rabbits were used and divided into four groups: control (C, n = 12), diabetic (D, n = 12, left parietal bone), diabetic with PTFe (DPTFe, same 12 rabbits, right parietal bone), and diabetic with PTFe associated to HDDM (D-PTFe+HDDM, n = 12). Bone defects were created in the parietal bone of the rabbits and the experimental treatments were performed, where applicable. The rabbits were sacrificed after 15, 30, 60 and 90 days. The bone defects were examined radiographically and by optical density (ANOVA and Tukey test, p < .05). The radiographic findings showed that the D-PTFe+HDDM group presented greater radiopacity and better trabecular bone arrangement when compared to that of the C, D and D-PTFe groups. The statistical analysis showed significant differences in the optical density of the newly formed bone among the studied groups. It was possible to conclude that HDDM was biocompatible in diabetic rabbits.
Resumo:
The aim of this study is to characterize the relationships in innovation and business clustering processes in the productive chain of small and medium enterprises (SME) of Brazil. The object of study are SMEs the local procuctive cluster of the shoes in Franca, State of São Paulo. The conceptual model developed is based on the following constructs: vertical integration, innovation and characteristics of the cluster, and it is focused on identifying the agents that act predominantly in product innovation processes in the cluster. A survey was conducted. It was found that there is cooperation between the companies in the productive arrangement studied, and that shoe manufacturers are those who, predominantly, stimulate innovation within the cluster.
Resumo:
Unstable shoes have been designed to promote "natural instability" and during walking they should simulate barefoot gait, enhancing muscle activity and, thus, attributing an advantage over regular tennis shoes. Recent studies showed that, after special training on the appropriate walking pattern, the use of the Masai Barefoot Technology (MBT) shoe increases muscle activation during walking. Our study presents a comparison of muscle activity as well as horizontal and vertical forces during gait with the MBT, a standard tennis shoe and barefoot walking of healthy individuals without previous training. These variables were compared in 25 female subjects and gait conditions were compared using ANOVA repeated measures (effect size:0.25). Walking with the MBT shoe in this non-instructed condition produced higher vertical forces (first vertical peak and weight acceptance rate) than walking with a standard shoe or walking barefoot, which suggests an increase in the loads received by the musculoskeletal system, especially at heel strike. Walking with the MBT shoe did not increase muscle activity when compared to walking with the standard shoe. The barefoot condition was more effective than the MBT shoe at enhancing muscle activation. Therefore, in healthy individuals, no advantage was found in using the MBT over a standard tennis shoe without a special training period. Further studies using the MBT without any instruction over a longer period are needed to evaluate if the higher loads observed in the present study would return to their baseline values after a period of adaptation, and if the muscle activity would increase over time. (C) 2012 Elsevier B.V. All rights reserved.