101 resultados para IMMUNODIAGNOSIS
Resumo:
An Immunoperoxidase technique for identification of leptospires in formalin fixed, paraffin embedded kidney sections is presented, using peroxidase-antiperoxidase complex. The anti-leptospiral antibody was raised in rabbit. Possible applications of this technique are discussed.
Resumo:
A dot enzyme-linked immunosorbent assay (DOT-ELISA) was developed to detect specific antibodies in cerebrospinal fluid (CSF) for human neurocysticercosis immunodiagnosis, with Cysticercus cellulosae antigen dotted on a new solid-phase. This was represented by sheets of a synthetic polyester fabric impregnated with a polymerized resin (N-methylol-acrylamide). A very stable preparation was thus obtained, the antigen being covalently bound by cross-linking with free N-methylol groups on the resin. Since robust, no special care was necessary for handling the solid-phase. The test could be performed at room-temperature. From 30 CSF samples assayed, 14 were positive, from a group of 15 cases of neurocysticercosis, with titers from 1 to 128; 15 other samples, from normals or other neurological diseases, were all negative. Test characteristics seem to indicate it as adequate for epidemiological surveys. A more detailed study on sensitivity, specificity, reproducibility and the use in serum samples is being conducted.
Resumo:
The dot-enzyme-linked immunosorbent assay (dot-ELISA) was standardized using somatic (S) and excretory-secretory (ES) antigens of Toxocara-canis for the detection of specific antibodies in 22 serum samples from children aged 1 to 15 years, with clinical signs of toxocariasis. Fourteen serum samples from apparently normal individuals and 28 sera from patients with other pathologies were used as controls. All samples were used before and after absorption with Ascaris suum extract. When the results were evaluated in comparison with ELISA, the two tests were found to have similar sensitivity, but dot-ELISA was found to be more specific in the presence of the two antigens studied. Dot-ELISA proved to be effective for the diagnosis of human toxocariasis, presenting advantages in terms of yield, stability, time and ease of execution and low cost.
Resumo:
Total serum IgE, and Strongyloides - specific IgG and IgA antibodies were studied in 27 patients with parasitologically proven strongyloidiasis. Clinical manifestations in this case series were investigated by a restrospective study of the patient's records. Total serum IgE levels were elevated (greater than 250 IU/ml) in 59% of the patients (mean concentration = 1364 IU/ml). Parasite - specific IgG and IgA antibodies were detected by ELISA in the serum of 23 (85.2%) and 21 (77.8%) patients, respectively. Elevated serum IgE and clinical manifestations were not useful indexes of the presence of strongyloidiasis. On the other hand, our results support the view that serologic tests, particularly ELISA for detecting Strongyloides - specific IgG antibodies, can be usefully exploited for diagnostic purposes in strongyloidiasis.
Resumo:
A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.
Resumo:
The sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) for the detection of circulating antigens from toxic components of Tityus serrulatus scorpion venom was determined in patients stung by T. serrulatus before antivenom administration. Thirty-seven patients were classified as mild cases and 19 as moderate or severe cases. The control absorbance in the venom assay was provided by serum samples from 100 individuals of same socioeconomic group and geographical area who had never been stung by scorpions or treated with horse antisera. The negative cutoff value (mean + 2 SD) corresponded to a venom concentration of 4.8 ng/ml. Three out of the 100 normal sera were positive, resulting in a specificity of 97%. The sensitivity of the ELISA when all cases of scorpion sting were included was 39.3%. When mild cases were excluded, the sensitivity increased to 94.7%. This study showed that this ELISA can be used for the detection of circulating venom toxic antigens in patients with systemic manifestations following. T. serrulatus sting but cannot be used for clinical studies in mild cases of envenoming since the test does not discriminate mild cases from control patients.
Resumo:
An immunoprecipitation technique, ELIEDA (enzyme-linked-immuno-electro-diffusion assay), was evaluated for the diagnosis of Schistosoma mansoni infection with low worm burden. One hundred of serum samples from patients excreting less than 600 eggs per gram of feces (epg), with unrelated diseases and clinically healthy subjects were studied. In patients with egg counts higher than 200 epg, the sensitivities of IgM and IgG ELIEDA were 1.000 and 0.923, respectively, not differing from other Serologic techniques, such as indirect hemaglutination (IHAT), immunofluorescence (IFT) tests and immuno-electrodiffusion assay (IEDA). However in patients with low egg counts (< 100 epg), the IgG ELIEDA provided better results (0.821) than IgM ELIEDA (0.679), showing sensitivity that did not differ from that of IgG IFT (0.929), but lower than that of IgM IFT (0.964). However, its sensivity was higher than that found with IHAT (0.607) and IEDA (0.536). The specificity of IgG ELIEDA was comparable to that of other techniques. The data indicate that IgG ELIEDA might be useful for the diagnosis of slight S. mansoni infections, and the cellulose acetate membrane strips can be stored for further retrospective studies.
Resumo:
The ORF strain of Cysticercus longicollis represents an important model for the study of heterologous antigens in the immunodiagnosis of neurocysticercosis (NC). The immunoperoxidase (IP) technique was standardized using a particulate antigen suspension of Cysticercus longicollis (Cl) and Cysticercus cellulosae (Cc). Cerebrospinal fluid (CSF) samples were incubated on the antigen fixed to microscopy slides; the conjugate employed was anti-IgG-peroxidase and the enzymatic reaction was started by covering the slides with chromogen solution (diaminobenzidine/H2O2). After washing with distilled water, the slide was stained with 2% malachite green in water. Of the CSF samples from 21 patients with NC, 19 (90.5%) were positive, whereas the 8 CSF samples from the control group (100%) were negative. The results of the IP-Cl test applied to 127 CSF samples from patients with suspected NC showed 28.3% reactivity as opposed to 29.1 % for the IP-Cc test. The agreement index for the IP test (Cl x Cc) was 94.2%, with no significant difference between the two antigens.
Resumo:
A dot-ELISA was developed for the detection of antibodies in CSF in the immunologic diagnosis of human neurocysticercosis, using antigen extracts of the membrane and scolex of Cysticercus cellulosae (M+S-Cc) and, alternately, membrane (M) and vesicular fluid (VF) of Cysticercus longicollis (Cl) covalently bound to a new solid phase consisting of polyester fabric treated with N-methylol-acrylamide resin (dot-RT). The test was performed at room temperature, with reduced incubation times and with no need for special care in the manipulation of the support. The sensitivity rates obtained were 95.1% for antigen Cc and 97.6% for antigen Cl. Specificity was 90.6% when Cc was used, and 96.9% and 100% when M-Cl and VF-Cl were used, respectively. No significant differences in titer were observed between tests carried out with homologous and heterologous antigens. The low cost and easy execution of the dot-RT test using antigen extracts of Cysticercus longicollis indicate the test for use in the immunodiagnosis of human neurocysticercosis.
Resumo:
Visceral larva migrans (VLM) is a clinical syndrome caused by infection of man by Toxocara spp, the common roundworm of dogs and cats. Tissue migration of larval stages causes illness specially in children. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. After the introduction of the enzyme-linked immunosorbent assay (ELISA) using the larval excretory-secretory antigen of T. canis (TES), the diagnosis specificity was greatly improved although cross-reactivity with other helminths are still being reported. In Brazil, diagnosis is routinely made after absorption of serum samples with Ascaris suum antigens, a nematode antigenicaly related with Ascaris lumbricoides which is a common intestinal nematode of children. In order to identify T. canis antigens that cross react to A. suum antigens we analyzed TES antigen by SDS-PAGE and Western blotting techniques. When we used serum samples from patients suspected of VLM and positive result by ELISA as well as a reference serum sample numerous bands were seen (molecular weight of 210-200 kDa, 116-97 kDa, 55-50 kDa and 35-29 kDa). Among these there is at least one band with molecular weight around 55-66 kDa that seem to be responsible for the cross-reactivity between T. canis e A. suum once it disappears when previous absorption of serum samples with A. suum antigens is performed
Resumo:
The persistence, in some subjects, of specific IgM antibodies to Toxoplasma gondii for several months after the acute phase of infection has complicated the interpretation of serological test results for toxoplasmosis. Several reports have emphasized the value of the detection of Toxoplasma-specific IgA antibodies for the diagnosis of acute toxoplasmosis. In this article, we report the follow-up profiles of Toxoplasma-specific IgM and IgA antibodies in serum samples obtained from 12 patients at various intervals after the onset of the clinical manifestations of infection. IgM antibodies were detected by the indirect immunofluorescence (IIF) test, antibody capture enzyme-linked immunosorbent assay (cELISA) and enzyme-mediated chemilluminescent technique (CmL). IgA antibodies were quantified by the direct ELISA (dELISA) and cELISA procedures. As defined by the manufacturer of the cELISA test for IgA used, most patients with acute toxoplasmosis have antibody levels > 40 arbritary units per ml (AU/ml). At values > 40 AU/ml, the cELISA for IgA detected significant antibody levels for a shorter time than the other techniques used for IgM and IgA detection. However, IgA levels £ 40 AU/ml do not exclude the possibility of acute toxoplasmosis since such levels can be reached very soon after infection with T. gondii. The results obtained in the present study show that the serological diagnosis of acute toxoplasmosis may not be such an easy task. Our data suggest that use of the IgA-cELISA concomitantly with IgM antibody screening could permit, in some circumstances, a more efficient diagnosis of acute acquired toxoplasmosis
Resumo:
The diagnostic potential of circulating IgM and IgA antibodies against Schistosoma mansoni gut-associated antigens detected by the immunofluorescence test (IFT) on adult worm paraffin sections was evaluated comparatively to the fecal parasitological method, for epidemiological purposes in low endemic areas for schistosomiasis. Blood samples were collected on filter paper from two groups of schoolchildren living in two different localities of the municipality of Itariri (São Paulo, Brazil) with different histories and prevalences of schistosomiasis. The parasitological and serological data were compared to those obtained for another group of schoolchildren from a non-endemic area for schistosomiasis. The results showed poor sensitivity of the parasitological method in detecting individuals with low worm burden and indicate the potential of the serological method as an important tool to be incorporated into schistosomiasis control and vigilance programs for determining the real situation of schistosomiasis in low endemic areas.
Resumo:
For a period of 2 years, five follow-up measures of prevalence and incidence rates were estimated in a prospective study of S. mansoni infection in a group of schoolchildren who were living in a rural area of the Municipality of Itariri (São Paulo, Brazil), where schistosomiasis is transmitted by Biomphalaria tenagophila. Infection was determined by the examination of three Kato-Katz stool slides, and the parasitological findings were analyzed in comparison to serological data. In the five surveys, carried out at 6-month intervals (March-April and September-October), the prevalences were, respectively, 8.6, 6.8, 9.9, 5.8 and 17.2% by the Kato-Katz, and 56.5, 52.6, 60.8, 53.5 and 70.1% by the immunofluorescence test (IFT). Geometric mean egg counts were low: 57.8, 33.0, 35.6, 47.3 and 40.9 eggs per gram of feces, respectively. Of the total of 299 schoolchildren, who submitted five blood samples at 6-month intervals, one for each survey, 40% were IFT-positive throughout the study, and 22% were IFT-negative in all five surveys. Seroconversion from IFT negative to positive, indicating newly acquired S. mansoni infection, was observed more frequently in surveys carried out during March-April (after Summer holidays), than during September-October. Seasonal trends were not statistically significant for detection of S. mansoni eggs in stool. The results indicate that the use of IgM-IFT is superior to parasitological methods for detection of incidence of S. mansoni infection in areas with low worm burden.
Resumo:
Toxocariasis is caused by infection of man by Toxocara canis and Toxocara cati larvae, the common roundworm of dogs and cats. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. Non specific reactions are observed mainly due to cross-reactivity with Ascaris sp antigens. This investigation aimed at developing and evaluating an indirect antibody competition ELISA (IACE) employing a specific rabbit IgG anti-Toxocara canis excretory-secretory antigens as the competition antibody, in order to improve indirect ELISA specificity performed for toxocariasis diagnosis. For that, the rabbit IgG was previously absorbed by Ascaris suum adult antigens. Sensitivity and specificity of IACE were first evaluated in 28 serum samples of mice experimentally infected with T. canis embryonated eggs. Adopting cut-off value established in this population before infection, sensitivity and specificity were 100% after 20 days post-inoculation. For human population IACE was evaluated using sera from 440 patients with clinical signs of toxocariasis and the cut-off value was established with 60 serum samples from apparently healthy individuals. Using as reference test the indirect ELISA performed by Adolfo Lutz Institute, sensitivity was 60.2%, specificity was 98% and concordance was 77.3%. Repeatability of IACE was evaluated by the inter-reactions variation coefficient (2.4%).
Resumo:
We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.