900 resultados para Human body


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A set of images which can be used within the University for teaching students.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Se presenta un objeto digital educativo pensado para alumnos de quinto curso de Primaria con el que conocerán, en inglés, las distintas partes de cuerpo humano, los cinco sentidos y a qué parte del cuerpo se asocian.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En esta guía de anatomía se pone de manifiesto la complejidad del cuerpo humano. Capa por capa, cada sistema es detallado y explicado, desde cómo funciona el sistema nervioso, la construcción de músculos y esqueleto, la piel, el cabello y las uñas y cómo se protege el cuerpo cuando está en peligro. Utilizando el DVD interactivo se pueden hacer primeros planos sobre una parte del cuerpo y ver la formación de los órganos, la acción de un nervio, la circulación de la sangre a través de una arteria, explorar las causas y los síntomas de las enfermedades y dolencias. Tiene glosario e índice alfabético.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As an obligatory parasite of humans, the body louse (Pediculus humanus humanus) is an important vector for human diseases, including epidemic typhus, relapsing fever, and trench fever. Here, we present genome sequences of the body louse and its primary bacterial endosymbiont Candidatus Riesia pediculicola. The body louse has the smallest known insect genome, spanning 108 Mb. Despite its status as an obligate parasite, it retains a remarkably complete basal insect repertoire of 10,773 protein-coding genes and 57 microRNAs. Representing hemimetabolous insects, the genome of the body louse thus provides a reference for studies of holometabolous insects. Compared with other insect genomes, the body louse genome contains significantly fewer genes associated with environmental sensing and response, including odorant and gustatory receptors and detoxifying enzymes. The unique architecture of the 18 minicircular mitochondrial chromosomes of the body louse may be linked to the loss of the gene encoding the mitochondrial single-stranded DNA binding protein. The genome of the obligatory louse endosymbiont Candidatus Riesia pediculicola encodes less than 600 genes on a short, linear chromosome and a circular plasmid. The plasmid harbors a unique arrangement of genes required for the synthesis of pantothenate, an essential vitamin deficient in the louse diet. The human body louse, its primary endosymbiont, and the bacterial pathogens that it vectors all possess genomes reduced in size compared with their free-living close relatives. Thus, the body louse genome project offers unique information and tools to use in advancing understanding of coevolution among vectors, symbionts, and pathogens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human Body Thermoregulation Models have been widely used in the field of human physiology or thermal comfort studies. However there are few studies on the evaluation method for these models. This paper summarises the existing evaluation methods and critically analyses the flaws. Based on that, a method for the evaluating the accuracy of the Human Body Thermoregulation models is proposed. The new evaluation method contributes to the development of Human Body Thermoregulation models and validates their accuracy both statistically and empirically. The accuracy of different models can be compared by the new method. Furthermore, the new method is not only suitable for the evaluation of Human Body Thermoregulation Models, but also can be theoretically applied to the evaluation of the accuracy of the population-based models in other research fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-performance liquid chromatography (HPLC) with tris(2,2-bipyridyl)ruthenium(II) chemiluminescence detection methodology is reported for the determination of the atypical antipsychotic drug quetiapine and the observation of its major active and inactive metabolites in human urine and serum. The method uses a monolithic chromatographic column allowing high flow rates of 3mL min−1 enabling rapid quantification. Flow injection analysis (FIA) with tris(2,2-bipyridyl)ruthenium(II) chemiluminescence detection and HPLC time of flight mass spectrometry (TOF-MS) were used for the determination of quetiapine in a pharmaceutical preparation to establish its suitability as a calibration standard. The limit of detection achieved with FIA was 2×10−11 mol L−1 in simple aqueous solution. The limits of detection achieved with HPLC were 7×10−8 and 2×10−10 mol L−1 in urine and serum, respectively. The calibration range for FIA was between 5×10−9 and 1×10−6 mol L−1. The calibration ranges for HPLC were between 1×10−7–1×10−4 and 1×10−8–1×10−4 mol L−1 in urine and serum, respectively. The quetiapine concentrations in patient samples were found to be 3×10−6 mol L−1 in urine and 7×10−7 mol L−1 in serum. Without the need for preconcentration, the HPLC detection limits compared favourably with those in previously published methodologies. The metabolites were identified using HPLC-TOF-MS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis deals with two electrical methods designed to enable rapid, safe and noninvasive measurement of body composition, both for clinical and community use. The first section provides a review of the literature related to measurement of body composition in humans and outlines the approach of the research project. The second section deals with established methods of determining body composition, the two most important being hydrostatic densitometry and deuterium oxide dilution. In this part of the report, a novel method for measuring lung volume by hydrogen dilution at the time of underwater weighing is described. The main findings of the thesis are contained in the third section which deals with the assessment of body opposition by electrical means. There are two components to this part of the study. The first involved the testing of a commercially available bioelectric impedance analyser (BIA) which measures impedance to a flow of current through the body. Studies on the reproducibility and reliability of measurements were performed. Results showed the importance of correct electrode placement and revealed that subjects can consume a light meal and a drink before being measured with the BIA without adversely affecting impedance readings. Results suggested, however, that subjects empty their bladders before measurements are made. Strong correlations were found between height 2/ resistance and measurements of total body water (r = 0.839) and fat-free weight derived from densitometry (r = 0.821), Moderate correlations (r = 0.6 to 0.7) were also found when height /resistance was related to fat-free weight derived from anthropometric measurements. The second and major consonant of the third section deals with the development of a method based on the absorption of energy from a weak electromagnetic field established in a capacitor or chamber large enough to accommodate an adult human subject. The method involves measurement of the effect of the body on the electromagnetic field, and is based on differential absorption of energy by body fat and fat-free tissues. Regression equations were developed for predicting the weight of fat and fat-free tissue in the body from measurement of electromagnetic field effects in a test capacitor and in a resonating chamber. The test capacitor comprised a large aluminum cylinder with a copper rod as a central conductor. The following equation was derived for the relationship of fat-free weight (FEW) based on body density, with measurements of change in resonant frequency (ΔfR), height (H) and weight (W) : FFW = -4.39 + 0.690 W + 19.9 H + 37.6 ΔfR In a study of 17 subjects, a value of 0.891 was found for R2, and S.E.E. was 1.63. The resonating chamber consisted of a large enclosed aluminium cylinder with a copper rod as a central conductor. The following equation was derived for the relationship of fat weight (FW) based on the mean of estimates from body density and total body water, with measurements of change in signal attenuation (ΔA), change in resonant frequency (ΔfR), and height (H) and weight (W) : FW = 73.48 + 0.291 (W/√(ΔA) - 49.2 H - 0.53 ΔfR In a study of 27 subjects, a value of 0.956 was found for R2, and S.E.E. was 1.97. In these equations, variables were measured in the following units : FEW, FW and W (kg), ΔfR (MHz) and H (m).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

 In this research, a novel method for generating training data of human postures with attached objects is proposed. The results has shown a significant increase in body-part classification accuracy for subjects with props from 60% to 94% using the generated image set

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Exergy analysis is applied to assess the energy conversion processes that take place in the human body, aiming at developing indicators of health and performance based on the concepts of exergy destroyed rate and exergy efficiency. The thermal behavior of the human body is simulated by a model composed of 15 cylinders with elliptical cross section representing: head, neck, trunk, arms, forearms, hands, thighs, legs, and feet. For each, a combination of tissues is considered. The energy equation is solved for each cylinder, being possible to obtain transitory response from the body due to a variation in environmental conditions. With this model, it is possible to obtain heat and mass flow rates to the environment due to radiation, convection, evaporation and respiration. The exergy balances provide the exergy variation due to heat and mass exchange over the body, and the exergy variation over time for each compartments tissue and blood, the sum of which leads to the total variation of the body. Results indicate that exergy destroyed and exergy efficiency decrease over lifespan and the human body is more efficient and destroys less exergy in lower relative humidities and higher temperatures. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A main objective of the human movement analysis is the quantitative description of joint kinematics and kinetics. This information may have great possibility to address clinical problems both in orthopaedics and motor rehabilitation. Previous studies have shown that the assessment of kinematics and kinetics from stereophotogrammetric data necessitates a setup phase, special equipment and expertise to operate. Besides, this procedure may cause feeling of uneasiness on the subjects and may hinder with their walking. The general aim of this thesis is the implementation and evaluation of new 2D markerless techniques, in order to contribute to the development of an alternative technique to the traditional stereophotogrammetric techniques. At first, the focus of the study has been the estimation of the ankle-foot complex kinematics during stance phase of the gait. Two particular cases were considered: subjects barefoot and subjects wearing ankle socks. The use of socks was investigated in view of the development of the hybrid method proposed in this work. Different algorithms were analyzed, evaluated and implemented in order to have a 2D markerless solution to estimate the kinematics for both cases. The validation of the proposed technique was done with a traditional stereophotogrammetric system. The implementation of the technique leads towards an easy to configure (and more comfortable for the subject) alternative to the traditional stereophotogrammetric system. Then, the abovementioned technique has been improved so that the measurement of knee flexion/extension could be done with a 2D markerless technique. The main changes on the implementation were on occlusion handling and background segmentation. With the additional constraints, the proposed technique was applied to the estimation of knee flexion/extension and compared with a traditional stereophotogrammetric system. Results showed that the knee flexion/extension estimation from traditional stereophotogrammetric system and the proposed markerless system were highly comparable, making the latter a potential alternative for clinical use. A contribution has also been given in the estimation of lower limb kinematics of the children with cerebral palsy (CP). For this purpose, a hybrid technique, which uses high-cut underwear and ankle socks as “segmental markers” in combination with a markerless methodology, was proposed. The proposed hybrid technique is different than the abovementioned markerless technique in terms of the algorithm chosen. Results showed that the proposed hybrid technique can become a simple and low-cost alternative to the traditional stereophotogrammetric systems.