999 resultados para Hollow Inclusion Technique
Resumo:
During the last decade the use of randomised gene libraries has had an enormous impact in the field of protein engineering. Such libraries comprise many variations of a single gene in which codon replacements are used to substitute key residues of the encoded protein. The expression of such libraries generates a library of randomised proteins which can subsequently be screened for desired or novel activities. Randomisation in this fashion has predominantly been achieved by the inclusion of the codons NNN or NNGCor T, in which N represents any of the four bases A,C,G, or T. The use of thesis codons however, necessities the cloning of redundant codons at each position of randomisation, in addition to those required to encode the twenty possible amino acid substitutions. As degenerate codons must be included at each position of randomisation, this results in a progressive loss of randomisation efficiency as the number of randomised positions is increased. The ratio of genes to proteins in these libraries rises exponentially with each position of randomisation, creating large gene libraries, which generate protein libraries of limited diversity upon expression. In addition to these problems of library size, the cloning of redundant codons also results in the generation of protein libraries in which substituted amino acids are unevenly represented. As several of the randomised codons may encode the same amino acid, for example serine which is encoded six time using the codon NNN, an inherent bias may be introduced into the resulting protein library during the randomisation procedure. The work outlined here describes the development of a novel randomisation technique aimed at a eliminating codon redundancy from randomised gene libraries, thus addressing the problems of library size and bias, associated with the cloning of redundant codons.
Resumo:
The first demonstration of a hollow core photonic bandgap fiber (HC-PBGF) suitable for high-rate data transmission in the 2 μm waveband is presented. The fiber has a record low loss for this wavelength region (4.5 dB/km at 1980 nm) and a >150 nm wide surface-mode-free transmission window at the center of the bandgap. Detailed analysis of the optical modes and their propagation along the fiber, carried out using a time-of-flight technique in conjunction with spatially and spectrally resolved (S) imaging, provides clear evidence that the HC-PBGF can be operated as quasi-single mode even though it supports up to four mode groups. Through the use of a custom built Thulium doped fiber amplifier with gain bandwidth closely matched to the fiber's low loss window, error-free 8 Gbit/s transmission in an optically amplified data channel at 2008 nm over 290 m of 19 cell HC-PBGF is reported. © 2013 Optical Society of America.
Resumo:
Increasingly, lab evaluations of mobile applications are incorporating mobility. The inclusion of mobility alone, however, is insufficient to generate a realistic evaluation context since real-life users will typically be required to monitor their environment while moving through it. While field evaluations represent a more realistic evaluation context, such evaluations pose difficulties, including data capture and environmental control, which mean that a lab-based evaluation is often a more practical choice. This paper describes a novel evaluation technique that mimics a realistic mobile usage context in a lab setting. The technique requires that participants monitor their environment and change the route they are walking to avoid dynamically changing hazards (much as reallife users would be required to do). Two studies that employed this technique are described, and the results (which indicate the technique is useful) are discussed.
Resumo:
Democratic innovations face the challenge of realizing deliberative democratic ideals in the context of structural inequality. Consensus decision making and expertise have been said to have exclusive effects on marginalized groups like women and ethnic and sexual minorities, which obstructs diversity. Wisdom Councils as practiced in Austria attempt to counter inequalities by including marginalized groups through the moderation technique dynamic facilitation. Exploratory participatory observations and interviews with a moderator and the participants of two Wisdom Councils in Austria provide a deeper understanding of the inclusive processes at work in Wisdom Councils facilitating a productive combination of consensus and diversity.
Resumo:
A novel processing method for the fast and economic production of hollow ceramic components has been developed by combining in situ coagulation moulding with a modified version of the technique of rotary moulding[Binner, J. G. P., Al-Dawery, I. A., Tari, G. and Yan, Y., Rotary casting technique. UK Patent application No. 0506349.0, March 2005], the latter being adapted from the polymer industry. The process was found to require a high solids content suspension, hence development work was performed in this direction though in the end a new, commercial suspension was utilised. Of the three forming routes of gel casting, direct coagulation casting and in situ coagulation moulding, the latter was found to be the most promising for the new process of rotary moulding of ceramics. Due to the low value of clay-based ceramics, a new low cost coagulant was identified and the effect of lactone concentration and temperature on setting time determined. Following substantial optimisation work, it was found that a two-speed approach to multi-axial rotation was the most successful; medium sized cream jugs could be produced in just 7 min. With respect to mould materials, the porous resin normally used for pressure casting of sanitary ware was found to be the best option, though since this is quite expensive conventional plaster-of-paris moulds were found to be a suitable material to enable companies, particularly SMEs, to become familiar with the technology whilst avoiding high costs for trials. The processed articles could be successfully fired and glazed using gas-fired kilns with no sign of any black cores. Major advantages of the process include the ability to precisely calculate the amount of ceramic slip required, eliminating either slip wastage or the need to pour used slip back into the virgin material as currently happens with slip casting. In addition, since the precursor suspension has a very high solids content, the time and energy required to dry the green product and associated moulds has been considerably reduced. © 2008 Elsevier Ltd. All rights reserved.
Resumo:
Hollow, cylindrical, prismatic light guides (CPLGs) are optical components that, using total internal reflection (TIR), are able to transmit high-diameter light beams in daylight and artificial lighting applications without relevant losses. It is necessary to study the prism defects of their surfaces to quantify the behavior of these optical components. In this Letter, we analyze a CPLG made of a transparent dielectric material. Scanning electron microscopy (SEM) and the topographic optical profilometry by absorption in fluids (TOPAF) imaging technique are conducted to determine if there are defects in the corners of the prisms. A model for light guide transmittance that is dependent on prism defects is proposed. Finally, a simulation and an experimental study are carried out to check the validity of the proposed model.
Resumo:
A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.
Resumo:
To evaluate patients with transverse fractures of the shaft of the humerus treated with indirect reduction and internal fixation with plate and screws through minimally invasive technique. Inclusion criteria were adult patients with transverse diaphyseal fractures of the humerus closed, isolated or not occurring within 15 days of the initial trauma. Exclusion criteria were patients with compound fractures. In two patients, proximal screw loosening occurred, however, the fractures consolidated in the same mean time as the rest of the series. Consolidation with up to 5 degrees of varus occurred in five cases and extension deficit was observed in the patient with olecranon fracture treated with tension band, which was not considered as a complication. There was no recurrence of infection or iatrogenic radial nerve injury. It can be concluded that minimally invasive osteosynthesis with bridge plate can be considered a safe and effective option for the treatment of transverse fractures of the humeral shaft. Level of Evidence III, Therapeutic Study.
Resumo:
To evaluate the outcomes in patients treated for humerus distal third fractures with MIPO technique and visualization of the radial nerve by an accessory approach, in those without radial palsy before surgery. The patients were treated with MIPO technique. The visualization and isolation of the radial nerve was done by an approach between the brachialis and the brachiorradialis, with an oblique incision, in the lateral side of the arm. MEPS was used to evaluate the elbow function. Seven patients were evaluated with a mean age of 29.8 years old. The average follow up was 29.85 months. The radial neuropraxis after surgery occurred in three patients. The sensorial recovery occurred after 3.16 months on average and also of the motor function, after 5.33 months on average, in all patients. We achieved fracture consolidation in all patients (M=4.22 months). The averages for flexion-extension and prono-supination were 112.85° and 145°, respectively. The MEPS average score was 86.42. There was no case of infection. This approach allowed excluding a radial nerve interposition on site of the fracture and/or under the plate, showing a high level of consolidation of the fracture and a good evolution of the range of movement of the elbow. Level of Evidence IV, Case Series.
Resumo:
Abstract Objective. The aim of this study was to evaluate the alteration of human enamel bleached with high concentrations of hydrogen peroxide associated with different activators. Materials and methods. Fifty enamel/dentin blocks (4 × 4 mm) were obtained from human third molars and randomized divided according to the bleaching procedure (n = 10): G1 = 35% hydrogen peroxide (HP - Whiteness HP Maxx); G2 = HP + Halogen lamp (HL); G3 = HP + 7% sodium bicarbonate (SB); G4 = HP + 20% sodium hydroxide (SH); and G5 = 38% hydrogen peroxide (OXB - Opalescence Xtra Boost). The bleaching treatments were performed in three sessions with a 7-day interval between them. The enamel content, before (baseline) and after bleaching, was determined using an FT-Raman spectrometer and was based on the concentration of phosphate, carbonate, and organic matrix. Statistical analysis was performed using two-way ANOVA for repeated measures and Tukey's test. Results. The results showed no significant differences between time of analysis (p = 0.5175) for most treatments and peak areas analyzed; and among bleaching treatments (p = 0.4184). The comparisons during and after bleaching revealed a significant difference in the HP group for the peak areas of carbonate and organic matrix, and for the organic matrix in OXB and HP+SH groups. Tukey's analysis determined that the difference, peak areas, and the interaction among treatment, time and peak was statistically significant (p < 0.05). Conclusion. The association of activators with hydrogen peroxide was effective in the alteration of enamel, mainly with regards to the organic matrix.
Resumo:
Context. The possibility of cephalic venous hypertension with the resultant facial edema and elevated cerebrospinal fluid pressure continues to challenge head and neck surgeons who perform bilateral radical neck dissections during simultaneous or staged procedures. Case Report. The staged procedure in patients who require bilateral neck dissections allows collateral venous drainage to develop, mainly through the internal and external vertebral plexuses, thereby minimizing the risks of deleterious consequences. Nevertheless, this procedure has disadvantages, such as a delay in definitive therapy, the need for a second hospitalization and anesthesia, and the risk of cutting lymphatic vessels and spreading viable cancer cells. In this paper, we discuss the rationale and feasibility of preserving the external jugular vein. Considering the limited number of similar reports in the literature, two cases in which this procedure was accomplished are described. The relevant anatomy and technique are reviewed and the patients' outcomes are discussed. Conclusion. Preservation of the EJV during bilateral neck dissections is technically feasible, fast, and safe, with clinically and radiologically demonstrated patency.
Resumo:
To verify the methods used by the clinical trials that assessed the effect of tactile/kinesthetic stimulation on weight gain in preterm infants and highlight the similarities and differences among such studies. This review collected studies from two databases, PEDro and PubMed, in July of 2014, in addition to bibliographies. Two researchers assessed the relevant titles independently, and then chose which studies to read in full and include in this review by consensus. Clinical trials that studied tactile stimulation or massage therapy whether or not associated with kinesthetic stimulation of preterm infants; that assessed weight gain after the intervention; that had a control group and were composed in English, Portuguese, or Spanish were included. A total of 520 titles were found and 108 were selected for manuscript reading. Repeated studies were excluded, resulting in 40 different studies. Of these, 31 met all the inclusion criteria. There were many differences in the application of tactile/kinesthetic stimulation techniques among studies, which hindered the accurate reproduction of the procedure. Also, many studies did not describe the adverse events that occurred during stimulation, the course of action taken when such events occurred, and their effect on the outcome. These studies made a relevant contribution towards indicating tactile/kinesthetic stimulation as a promising tool. Nevertheless, there was no standard for application among them. Future studies should raise the level of methodological rigor and describe the adverse events. This may permit other researchers to be more aware of expected outcomes, and a standard technique could be established.
Resumo:
Objective To assess the prevalence of insulin resistance (IR) and associated factors in contraceptive users. Methods A total of 47 women 18 to 40 years of age with a body mass index (kg/m(2)) < 30, fasting glucose levels < 100 mg/dl and 2-hour glucose level < 140 mg/dl after a 75-g oral glucose load were submitted to a hyperinsulinemic-euglycemic clamp. The women were distributed in tertiles regarding M-values. The analysed variables were use of combined hormonal/non-hormonal contraception, duration of use, body composition, lipid profile, glucose levels and blood pressure. Results IR was detected in 19% of the participants. The women with low M-values presented significantly higher body fat mass, waist-to-hip ratio, fasting insulin, HOMA-IR and were nulligravida, showed > 1 year of contraceptive use and higher triglyceride levels. IR was more frequent among combined oral contraceptive users, however no association was observed after regression analysis. Conclusions The prevalence of IR was high among healthy women attending a family planning clinic independent of the contraceptive method used with possible long-term negative consequences regarding their metabolic and cardiovascular health. Although an association between hormonal contraception and IR could not be found this needs further research. Family planning professionals should be proactive counselling healthy women about the importance of healthy habits.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física