978 resultados para Hold harmless
Resumo:
Domestic violence is now widely acknowledged as being a significant social, health and legal issue. At both a national and transnational level governments have sought to develop strategies built upon prevention, support for victims and holding perpetrators to account through criminal justice sanctions. However, the current paradigm that informs the policy response to most perpetrators of domestic violence has failed to deliver the outcomes required, in terms of a reduction in levels of recidivism or the improved safety of women and children. It is argued that holding men to account through external controls has failed and that interventions should support men to take responsibility for their own behaviour.
Resumo:
PURPOSE: To investigate the effects of using volumetric modulated arc therapy (VMAT) and/or voluntary moderate deep inspiration breath-hold (vmDIBH) in the radiation therapy (RT) of left-sided breast cancer including the regional lymph nodes.
MATERIALS AND METHODS: For 13 patients, four treatment combinations were compared; 3D-conformal RT (i.e., forward IMRT) in free-breathing 3D-CRT(FB), 3D-CRT(vmDIBH), 2 partial arcs VMAT(FB), and VMAT(vmDIBH). Prescribed dose was 42.56 Gy in 16 fractions. For 10 additional patients, 3D-CRT and VMAT in vmDIBH only were also compared.
RESULTS: Dose conformity, PTV coverage, ipsilateral and total lung doses were significantly better for VMAT plans compared to 3D-CRT. Mean heart dose (D(mean,heart)) reduction in 3D-CRT(vmDIBH) was between 0.9 and 8.6 Gy, depending on initial D(mean,heart) (in 3D-CRT(FB) plans). VMAT(vmDIBH) reduced the D(mean,heart) further when D(mean,heart) was still >3.2 Gy in 3D-CRT(vmDIBH). Mean contralateral breast dose was higher for VMAT plans (2.7 Gy) compared to 3DCRT plans (0.7 Gy).
CONCLUSIONS: VMAT and 3D-CRT(vmDIBH) significantly reduced heart dose for patients treated with locoregional RT of left-sided breast cancer. When Dmean,heart exceeded 3.2 Gy in 3D-CRT(vmDIBH) plans, VMAT(vmDIBH) resulted in a cumulative heart dose reduction. VMAT also provided better target coverage and reduced ipsilateral lung dose, at the expense of a small increase in the dose to the contralateral breast.
Resumo:
Background: In a selective group of patients accelerated partial breast irradiation (APBI) might be applied after conservative breast surgery to reduce the amount of irradiated healthy tissue. The role of volumetric modulated arc therapy (VMAT) and voluntary moderately deep inspiration breath-hold (vmDIBH) techniques in further reducing irradiated healthy – especially heart – tissue is investigated.
Material and methods: For 37 partial breast planning target volumes (PTVs), three-dimensional conformal radiotherapy (3D-CRT) (3 – 5 coplanar or non-coplanar 6 and/or 10 MV beams) and VMAT (two partial 6 MV arcs) plans were made on CTs acquired in free-breathing (FB) and/or in vmDIBH. Dose-volume parameters for the PTV, heart, lungs, and breasts were compared.
Results: Better dose conformity was achieved with VMAT compared to 3D-CRT (conformity index 1.24 0.09 vs. 1.49 0.20). Non-PTV ipsilateral breast receiving 50% of the prescribed dose was on average reduced by 28% in VMAT plans compared to 3D-CRT plans. Mean heart dose (MHD) reduced from 2.0 (0.1 – 5.1) Gy in 3D-CRT(FB) to 0.6 (0.1 – 1.6) Gy in VMAT(vmDIBH). VMAT is benefi cial for MHD reduction if MHD with 3D-CRT exceeds 0.5Gy. Cardiac dose reduction as a result of VMAT increases with increasing initial MHD, and adding vmDIBH reduces the cardiac dose further. Mean dose to the ipsilateral lung decreased from 3.7 (0.7 – 8.7) to 1.8 (0.5 – 4.0) Gy with VMAT(vmDIBH) compared to 3D-CRT(FB). VMAT resulted in a slight increase in the contralateral breast dose (DMean ) always remaining 1.9 Gy).
Conclusions: For APBI patients, VMAT improves PTV dose conformity and delivers lower doses to the ipsilateral breast and lung compared to 3D-CRT. This goes at the cost of a slight but acceptable increase of the contralateral breast dose. VMAT reduces cardiac dose if MHD exceeds 0.5 Gy for 3D-CRT. Adding vmDIBH results in a further reduction of heart and ipsilateral lung dose.
Resumo:
A patient with loin pain haematuria syndrome suffering chronic throbbing pulsing pain overlaid with prolonged periods of incapacitating colic and overnight vomiting was presented 10 months following diagnosis. Ultrasound was normal. No renal or ureteral stones, or filling defects were seen on CT. At cytoscopy, bladder and urethra were normal, and bloody urine effluxed from the left ureteric orifice. The ureters were normal at diagnosis, and developed new abutting non‐penetrating calcifications by 8 months. Pain episodes of complete incapacitating intensity of 2–4 h duration were reduced to 10 min with 5 mg crushed tadalafil administered at onset. If tadalafil was delayed to after onset, the original course of agony resulted. Daily tadalafil reduced loin pain intensity, but not the exacerbations. Tadalafil efficacy may indicate that the pain exacerbations are due to spasm of ureter smooth muscle. 5 mg tadalafil taken at onset alleviated severe loin pain exacerbations in this case of loin pain haematuria syndrome.
Resumo:
UANL
Resumo:
UANL
Resumo:
domestic knitting machine tutorial
Resumo:
El Capitán Daylight es un simpático asaltante de caminos, al que le gusta más gastar bromas a la gente que robar. Pero un día, decide que quiere cambiar su imagen y para ello se disfraza como el osado atracador de diligencias, Black Jack Midnight. Sin embargo, su carácter bonachón y su torpeza no han cambiado con el nuevo ropaje.
Resumo:
1Urban areas are predicted to grow significantly in the foreseeable future because of increasing human population growth. Predicting the impact of urban development and expansion on mammal populations is of considerable interest due to possible effects on biodiversity and human-wildlife conflict. 2The British government has recently announced a substantial housing programme to meet the demands of its growing population and changing socio-economic profile. This is likely to result in the construction of high-density, low-cost housing with small residential gardens. To assess the potential effects of this programme, we analysed the factors affecting the current pattern of use of residential gardens by a range of mammal species using a questionnaire distributed in wildlife and gardening magazines and via The Mammal Society. 3Twenty-two species/species groups were recorded. However, the pattern of garden use by individual species was limited, with only six species/species groups (bats, red fox Vulpes vulpes, grey squirrel Sciurus carolinensis, hedgehog Erinaceus europaeus, mice, voles) recorded as frequent visitors to > 20% of gardens in the survey. 4There was a high degree of association between the variables recorded in the study, such that it was difficult to quantify the effects of individual variables. However, all species/species groups appeared to be negatively affected by the increased fragmentation and reduced proximity of natural and semi-natural habitats, decreasing garden size and garden structure, but to differing degrees. Patterns of garden use were most clearly affected by house location (city, town, village, rural), with garden use declining with increasing urbanization for the majority of species/species groups, except red foxes and grey squirrels. Increasing urbanization is likely to be related to a wide range of interrelated factors, any or all of which may affect a range of mammal species. 5Overall, the probable effects of the planned housing development programme in Britain are not likely to be beneficial to mammal populations, although the pattern of use examined in this study may represent patterns of habitat selection by species rather than differences in distribution or abundance. Consequently, additional data are required on the factors affecting the density of species within urban environments.
Resumo:
CVD is a common killer in both the Western world and the developing world. It is a multifactorial disease that is influenced by many environmental and genetic factors. Although public health advice to date has been principally in the form of prescribed population-based recommendations, this approach has been surprisingly unsuccessful in reducing CVD risk. This outcome may be explained, in part, by the extreme variability in response to dietary manipulations between individuals and interactions between diet and an individual's genetic background, which are defined by the term 'nutrigenetics'. The shift towards personalised nutritional advice is a very attractive proposition. In principle an individual could be genotyped and given dietary advice specifically tailored to their genetic make-up. Evidence-based research into interactions between fixed genetic variants, nutrient intake and biomarkers of CVD risk is increasing, but still limited. The present paper will review the evidence for interactions between dietary fat and three common polymorphisms in the apoE, apoAI and PPAR gamma genes. Increased knowledge of how these and other genes influence dietary response should increase the understanding of personalised nutrition. While targeted dietary advice may have considerable potential for reducing CVD risk, the ethical issues associated with its routine use need careful consideration.
Resumo:
Time dependent gas hold-up generated in the 0.3 and 0.6 m diameter vessels using high viscosity castor oil and carboxy methyl cellulose (CMC) solution was compared on the basis of impeller speed (N) and gas velocity (V-G). Two types of hold-up were distinguished-the hold-up due to tiny bubbles (epsilon(ft)) and total hold-up (epsilon(f)), which included large and tiny bubbles. It was noted that vessel diameter (i.e. the scale of operation) significantly influences (i) the trends and the values of epsilon(f) and epsilon(ft), and (ii) the values of tau (a constant reflecting the time dependency of hold-up). The results showed that a scale independent correlation for gas hold-up of the form epsilon(f) or epsilon(ft) = A(N or P-G/V)(a) (V-G)(b), where "a" and "b" are positive constants is not appropriate for viscous liquids. This warrants further investigations into the effect of vessel diameter on gas hold-up in impeller agitated high viscosity liquids (mu or mu(a) > 0.4 Pa s). (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
R. Benjamin (1995) addressed the application of the “object 3D” X ray reconstruction technique for electronically “unpacking” suspect items, when screening aircraft luggage. However, there is no satisfactory solution to the mass screening of hold luggage. Computed Tomography, CT, entails excessive radiation dosages, and its rate of throughput is quite inadequate. A novel variant of “object 3D” is therefore put forward, adapting some of the technology of existing cabin luggage screening systems-but on a substantially larger scale-which does achieve the required throughput at an acceptable radiation dosage and cost.
Resumo:
Understanding the onset of coronal mass ejections (CMEs) is surely one of the holy grails of solar physics today. Inspection of data from the Heliospheric Imagers (HI), which are part of the SECCHI instrument suite aboard the two NASA STEREO spacecraft, appears to have revealed pre-eruption signatures which may provide valuable evidence for identifying the CME onset mechanism. Specifically, an examination of the HI images has revealed narrow rays comprised of a series of outward-propagating plasma blobs apparently forming near the edge of the streamer belt prior to many CME eruptions. In this pilot study, we inspect a limited dataset to explore the significance of this phenomenon, which we have termed a pre-CME ‘fuse’. Although, the enhanced expulsion of blobs may be consistent with an increase in the release of outward-propagating blobs from the streamers themselves, it could also be interpreted as evidence for interchange reconnection in the period leading to a CME onset. Indeed, it is argued that the latter could even have implications for the end-of-life of CMEs. Thus, the presence of these pre-CME fuses provides evidence that the CME onset mechanism is either related to streamer reconnection processes or the reconnection between closed field lines in the streamer belt and adjacent, open field lines. We investigate the nature of these fuses, including their timing and location with respect to CME launch sites, as well as their speed and topology.