991 resultados para High-flux


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new class of high molecular weight polyethersulfone ionomers is described in which the ionic content can be varied, at will, over a very wide and fully-controllable range. A novel type of coating process enables these materials to be deposited from alcohol-type solvents as cohesive but very thin (50 – 250 nm) films on porous support-membranes, giving high-flux membranes (3.3 – 5.0 L m-2 h-1 bar-1) with very good, though not outstanding salt rejection (typically 92 - 96%). A secondary layer, of formaldehyde-cross-linked polyvinyl alcohol, can be deposited from aqueous solution on the surface of the ionomer membrane, and this layer increases salt rejection to greater than 99% without serious loss of water permeability. The final multi-layer membrane shows excellent chlorine tolerance in reverse-osmosis operation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Planktic foraminiferal (PF) flux and faunal composition from three sediment trap time series of 2002-2004 in the northeastern Atlantic show pronounced year-to-year variations despite similar sea surface temperature (SST). The averaged fauna of the in 2002/2003 is dominated by the species Globigerinita glutinata, whereas in 2003/2004 the averaged fauna is dominated by Globigerinoides ruber. We show that PF species respond primarily to productivity, triggered by the seasonal dynamics of vertical stratification of the upper water column. Multivariate statistical analysis reveals three distinct species groups, linked to bulk particle flux, to chlorophyll concentrations and to summer/fall oligotrophy with high SST and stratification. We speculate that the distinct nutrition strategies of strictly asymbiontic, facultatively symbiontic, and symbiontic species may play a key role in explaining their abundances and temporal succession. Advection of water masses within the Azores Current and species expatriation result in a highly diverse PF assemblage. The Azores Frontal Zone may have influenced the trap site in 2002, indicated by subsurface water cooling, by highest PF flux and high flux of the deep-dwelling species Globorotalia scitula. Similarity analyses with core top samples from the global ocean including 746 sites from the Atlantic suggest that the trap faunas have only poor analogs in the surface sediments. These differences have to be taken into account when estimating past oceanic properties from sediment PF data in the eastern subtropical North Atlantic.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In SSL general illumination, there is a clear trend to high flux packages with higher efficiency and higher CRI addressed with the use of multiple color chips and phosphors. However, such light sources require the optics provide color mixing, both in the near-field and far-field. This design problem is specially challenging for collimated luminaries, in which diffusers (which dramatically reduce the brightness) cannot be applied without enlarging the exit aperture too much. In this work we present first injection molded prototypes of a novel primary shell-shaped optics that have microlenses on both sides to provide Köhler integration. This shell is design so when it is placed on top of an inhomogeneous multichip Lambertian LED, creates a highly homogeneous virtual source (i.e, spatially and angularly mixed), also Lambertian, which is located in the same position with only small increment of the size (about 10-20%, so the average brightness is similar to the brightness of the source). This shell-mixer device is very versatile and permits now to use a lens or a reflector secondary optics to collimate the light as desired, without color separation effects. Experimental measurements have shown optical efficiency of the shell of 95%, and highly homogeneous angular intensity distribution of collimated beams, in good agreement with the ray-tracing simulations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Helium retention in irradiated tungsten leads to swelling, pore formation, sample exfoliation and embrittlement with deleterious consequences in many applications. In particular, the use of tungsten in future nuclear fusion plants is proposed due to its good refractory properties. However, serious concerns about tungsten survivability stems from the fact that it must withstand severe irradiation conditions. In magnetic fusion as well as in inertial fusion (particularly with direct drive targets), tungsten components will be exposed to low and high energy ion (helium) irradiation, respectively. A common feature is that the most detrimental situations will take place in pulsed mode, i.e., high flux irradiation. There is increasing evidence on a correlation between a high helium flux and an enhancement of detrimental effects on tungsten. Nevertheless, the nature of these effects is not well understood due to the subtleties imposed by the exact temperature profile evolution, ion energy, pulse duration, existence of impurities and simultaneous irradiation with other species. Physically based Kinetic Monte Carlo is the technique of choice to simulate the evolution of radiation-induced damage inside solids in large temporal and space scales. We have used the recently developed code MMonCa (Modular Monte Carlo simulator), presented in this conference for the first time, to study He retention (and in general defect evolution) in tungsten samples irradiated with high intensity helium pulses. The code simulates the interactions among a large variety of defects and impurities (He and C) during the irradiation stage and the subsequent annealing steps. In addition, it allows us to vary the sample temperature to follow the severe thermo-mechanical effects of the pulses. In this work we will describe the helium kinetics for different irradiation conditions. A competition is established between fast helium cluster migration and trapping at large defects, being the temperature a determinant factor. In fact, high temperatures (induced by the pulses) are responsible for large vacancy cluster formation and subsequent additional trapping with respect to low flux irradiation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Helium retention in irradiated tungsten leads to swelling, pore formation, sample exfoliation and embrittlement with deleterious consequences in many applications. In particular, the use of tungsten in future nuclear fusion plants is proposed due to its good refractory properties. However, serious concerns about tungsten survivability stems from the fact that it must withstand severe irradiation conditions. In magnetic fusion as well as in inertial fusion (particularly with direct drive targets), tungsten components will be exposed to low and high energy ion irradiation (helium), respectively. A common feature is that the most detrimental situations will take place in pulsed mode, i.e., high flux irradiation. There is increasing evidence of a correlation between a high helium flux and an enhancement of detrimental effects on tungsten. Nevertheless, the nature of these effects is not well understood due to the subtleties imposed by the exact temperature profile evolution, ion energy, pulse duration, existence of impurities and simultaneous irradiation with other species. Object Kinetic Monte Carlo is the technique of choice to simulate the evolution of radiation-induced damage inside solids in large temporal and space scales. We have used the recently developed code MMonCa (Modular Monte Carlo simulator), presented at COSIRES 2012 for the first time, to study He retention (and in general defect evolution) in tungsten samples irradiated with high intensity helium pulses. The code simulates the interactions among a large variety of defects and during the irradiation stage and the subsequent annealing steps. The results show that the pulsed mode leads to significantly higher He retention at temperatures higher than 700 K. In this paper we discuss the process of He retention in terms of trap evolution. In addition, we discuss the implications of these findings for inertial fusion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The transfer of carbon (C) from Amazon forests to aquatic ecosystems as CO(2) supersaturated in groundwater that outgases to the atmosphere after it reaches small streams has been postulated to be an important component of terrestrial ecosystem C budgets. We measured C losses as soil respiration and methane (CH(4)) flux, direct CO(2) and CH(4) fluxes from the stream surface and fluvial export of dissolved inorganic C (DIC), dissolved organic C (DOC), and particulate C over an annual hydrologic cycle from a 1,319-ha forested Amazon perennial first-order headwater watershed at Tanguro Ranch in the southern Amazon state of Mato Grosso. Stream pCO(2) concentrations ranged from 6,491 to 14,976 mu atm and directly-measured stream CO(2) outgassing flux was 5,994 +/- A 677 g C m(-2) y(-1) of stream surface. Stream pCH(4) concentrations ranged from 291 to 438 mu atm and measured stream CH(4) outgassing flux was 987 +/- A 221 g C m(-2) y(-1). Despite high flux rates from the stream surface, the small area of stream itself (970 m(2), or 0.007% of watershed area) led to small directly-measured annual fluxes of CO(2) (0.44 +/- A 0.05 g C m(2) y(-1)) and CH(4) (0.07 +/- A 0.02 g C m(2) y(-1)) per unit watershed land area. Measured fluvial export of DIC (0.78 +/- A 0.04 g C m(-2) y(-1)), DOC (0.16 +/- A 0.03 g C m(-2) y(-1)) and coarse plus fine particulate C (0.001 +/- A 0.001 g C m(-2) y(-1)) per unit watershed land area were also small. However, stream discharge accounted for only 12% of the modeled annual watershed water output because deep groundwater flows dominated total runoff from the watershed. When C in this bypassing groundwater was included, total watershed export was 10.83 g C m(-2) y(-1) as CO(2) outgassing, 11.29 g C m(-2) y(-1) as fluvial DIC and 0.64 g C m(-2) y(-1) as fluvial DOC. Outgassing fluxes were somewhat lower than the 40-50 g C m(-2) y(-1) reported from other Amazon watersheds and may result in part from lower annual rainfall at Tanguro. Total stream-associated gaseous C losses were two orders of magnitude less than soil respiration (696 +/- A 147 g C m(-2) y(-1)), but total losses of C transported by water comprised up to about 20% of the +/- A 150 g C m(-2) (+/- 1.5 Mg C ha(-1)) that is exchanged annually across Amazon tropical forest canopies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A insuficiência renal crónica tem como possível tratamento a hemodiálise de alto-fluxo de hemodiafiltração. Este estudo tem por objectivo caracterizar a qualidade de águas de diálise, provenientes de 4 clínicas. Realizou-se um estudo observacional descritivo transversal com base nos resultados das análises de águas de diálise, de 07-2009 a 04-2010. Nas amostras, à entrada do tratamento, verificou-se que 100% destas se encontravam nãoconformes nos parâmetros microbiológicos e 53,85% apresentavam-se não-conformes nos parâmetros químicos. Após tratamento, 6,41% continuavam não-conformes nos parâmetros microbiológicos e todas as amostras apresentaram-se conformes nos parâmetros químicos. Conclui-se que o tratamento tem elevado grau de efectividade.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The process of on-line generation of ultrapure dialysis fluid is a core prerequisite for the safe execution of modern renal replacement therapies such as on-line hemodiafiltration and high-flux hemodialysis. In these extracorporeal treatments with variable degrees of convection, significant volumes of plasma water are removed and replaced with dialysis fluid, which must occur without causing harm to the patient. Historically, on-line generation of sterile and pyrogen-free physiological substitution fluid by the process of membrane ultrafiltration of fresh dialysis fluid has its origin in hemofiltration, a purely convective therapy. Development of this and later therapies is described in the historical context of a successful effort over decades to overcome the above formidable challenge, which was provided jointly by pioneering clinical investigators and a resourceful dialysis industry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cefepime is a broad-spectrum cephalosporin indicated for in-hospital treatment of severe infections. Acute neurotoxicity, an increasingly recognized adverse effect of this drug in an overdose, predominantly affects patients with reduced renal function. Although dialytic approaches have been advocated to treat this condition, their role in this indication remains unclear. We report the case of an 88-year-old female patient with impaired renal function who developed life-threatening neurologic symptoms during cefepime therapy. She was treated with two intermittent 3-hour high-flux, high-efficiency hemodialysis sessions. Serial pre-, post-, and peridialytic (pre- and postfilter) serum cefepime concentrations were measured. Pharmacokinetic modeling showed that this dialytic strategy allowed for serum cefepime concentrations to return to the estimated nontoxic range 15 hours earlier than would have been the case without an intervention. The patient made a full clinical recovery over the next 48 hours. We conclude that at least 1 session of intermittent hemodialysis may shorten the time to return to the nontoxic range in severe clinically patent intoxication. It should be considered early in its clinical course pending chemical confirmation, even in frail elderly patients. Careful dosage adjustment and a high index of suspicion are essential in this population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Agricultural soils can act as a source or sink of atmospheric C, according to the soil management. This long-term experiment (22 years) was evaluated during 30 days in autumn, to quantify the effect of tillage systems (conventional tillage-CT and no-till-NT) on the soil CO2-C flux in a Rhodic Hapludox in Rio Grande do Sul State, Southern Brazil. A closed-dynamic system (Flux Chamber 6400-09, Licor) and a static system (alkali absorption) were used to measure soil CO2-C flux immediately after soybean harvest. Soil temperature and soil moisture were measured simultaneously with CO2-C flux, by Licor-6400 soil temperature probe and manual TDR, respectively. During the entire month, a CO2-C emission of less than 30 % of the C input through soybean crop residues was estimated. In the mean of a 30 day period, the CO2-C flux in NT soil was similar to CT, independent of the chamber type used for measurements. Differences in tillage systems with dynamic chamber were verified only in short term (daily evaluation), where NT had higher CO2-C flux than CT at the beginning of the evaluation period and lower flux at the end. The dynamic chamber was more efficient than the static chamber in capturing variations in CO2-C flux as a function of abiotic factors. In this chamber, the soil temperature and the water-filled pore space (WFPS), in the NT soil, explained 83 and 62 % of CO2-C flux, respectively. The Q10 factor, which evaluates CO2-C flux dependence on soil temperature, was estimated as 3.93, suggesting a high sensitivity of the biological activity to changes in soil temperature during fall season. The CO2-C flux measured in a closed dynamic chamber was correlated with the static alkali adsorption chamber only in the NT system, although the values were underestimated in comparison to the other, particularly in the case of high flux values. At low soil temperature and WFPS conditions, soil tillage caused a limited increase in soil CO2-C flux.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Hyperhomocysteinaemia has been identified as an independent cardiovascular risk factor and is found in more than 85% of patients on maintenance haemodialysis. Previous studies have shown that folic acid can lower circulating homocysteine in dialysis patients. We evaluated prospectively the effect of increasing the folic acid dosage from 1 to 6 mg per dialysis on plasma total homocysteine levels of haemodialysis patients with and without a history of occlusive vascular artery disease (OVD). METHODS: Thirty-nine stable patients on high-flux dialysis were studied. Their mean age was 63 +/-11 years and 17 (43%) had a history of OVD, either coronary and/or cerebral and/or peripheral occlusive disease. For several years prior to the study, the patients had received an oral post-dialysis multivitamin supplement including 1 mg of folic acid per dialysis. After baseline determinations, the folic acid dose was increased from 1 to 6 mg/dialysis for 3 months. RESULTS: After 3 months, plasma homocysteine had decreased significantly by approximately 23% from 31.1 +/- 12.7 to 24.5 +/- 9 micromol/l (P = 0.0005), while folic acid concentrations had increased from 6.5 +/- 2.5 to 14.4+/-2.5 microg/l (P < 0.0001). However, the decrease of homocysteine was quite different in patients with and in those without OVD. In patients with OVD, homocysteine decreased only marginally by approximately 2.5% (from 29.0 +/- 10.3 to 28.3 +/- 8.4 micromol/l, P = 0.74), whereas in patients without OVD there was a significant reduction of approximately 34% (from 32.7+/-14.4 to 21.6+/-8.6 micromol/l, P = 0.0008). Plasma homocysteine levels were reduced by > 15% in three patients (18%) in the group with OVD compared with 19 (86%) in the group without OVD (P = 0.001), and by > 30% in none of the patients (0%) in the former group compared with 13 (59%) in the latter (P = 0.001). CONCLUSIONS: These results indicate that the homocysteine-lowering effect of folic acid administration appears to be less effective in haemodialysis patients having occlusive vascular disease than in those without evidence of such disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.