817 resultados para Heart valve


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cardiovascular diseases (CVD) contributed to almost 30% of worldwide mortality; with heart failure being one class of CVD. One popular and widely available treatment for heart failure is the intra-aortic balloon pump (IABP). This heart assist device is used in counterpulsation to improve myocardial function by increasing coronary perfusion, and decreasing aortic end-diastolic pressure (i.e. the resistance to blood ejection from the heart). However, this device can only be used acutely, and patients are bedridden. The subject of this research is a novel heart assist treatment called the Chronic Intermittent Mechanical Support (CIMS) which was conceived to offer advantages of the IABP device chronically, whilst overcoming its disadvantages. The CIMS device comprises an implantable balloon pump, a percutaneous drive line, and a wearable driver console. The research here aims to determine the haemodynamic effect of balloon pump activation under in vitro conditions. A human mock circulatory loop (MCL) with systemic and coronary perfusion was constructed, capable of simulating various degrees of heart failure. Two prototypes of the CIMS balloon pump were made with varying stiffness. Several experimental factors (balloon inflation/deflation timing, Helium gas volume, arterial compliance, balloon pump stiffness and heart valve type) form the factorial design experiments. A simple modification to the MCL allowed flow visualisation experiments using video recording. Suitable statistical tests were used to analyse the data obtained from all experiments. Balloon inflation and deflation in the ascending aorta of the MCL yielded favourable results. The sudden balloon deflation caused the heart valve to open earlier, thus causing longer valve opening duration in a cardiac cycle. It was also found that pressure augmentation in diastole was significantly correlated with increased cardiac output and coronary flowrate. With an optimum combination (low arterial compliance and low balloon pump stiffness), systemic and coronary perfusions were increased by 18% and 21% respectively, while the aortic end-diastolic pressure (forward flow resistance) decreased by 17%. Consequently, the ratio of oxygen supply and demand to myocardium (endocardial viability ratio, EVR) increased between 33% and 75%. The increase was mostly attributed to diastolic augmentation rather than systolic unloading.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: The appropriateness of rheumatic mitral valve repair remains controversial due to the risks of recurrent mitral dysfunction and need for reoperation. The aims of this study were to determine the overall short- and long-term outcomes of pediatric rheumatic mitral valve surgery in our center. METHODS: Single-center, observational, retrospective study that analyzed the results of rheumatic mitral valve surgery in young patients, consecutively operated by the same team, between 1999 and 2014. RESULTS: We included 116 patients (mean age = 12.6 ± 3.5 years), of which 66 (57%) were females. A total of 116 primary surgical interventions and 22 reoperations were performed. Primary valve repair was possible in 86 (74%) patients and valve replacement occurred in 30 (26%). Sixty percent of the patients were followed up beyond three months after surgery (median follow-up time = 9.2 months [minimum = 10 days; maximum = 15 years]). Long-term clinical outcomes were favorable, with most patients in New York Heart Association functional class I (89.6%) and in sinus rhythm (85%). Freedom from reoperation for primary valve repair at six months, five years, and ten years was 96.4% ± 0.25%, 72% ± 0.72%, and 44.7% ± 1.34%, respectively. Freedom from reoperation for primary valve replacement at six months, five years, and ten years was 100%, 91.7% ± 0.86%, and 91.7% ± 0.86%, respectively. Mitral stenosis as the primary lesion dictated early reintervention. CONCLUSIONS: Despite the greater rate of reoperation, especially when the primary lesion was mitral stenosis, rheumatic mitral valve repair provides similar clinical outcomes as compared with replacement, with the advantage of avoiding anticoagulation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aortic root replacement is a complex procedure, though subsequent modifications of the original Bentall procedure have made surgery more reproducible. The study aim was to examine the outcomes of a modified Bentall procedure, using the Medtronic Open PivotTM valved conduit. Whilst short-term data on the conduit and long-term data on the valve itself are available, little is known of the long-term results with the valved conduit. Patients undergoing aortic root replacement between February 1999 and February 2010, using the Medtronic Open Pivot valved conduit were identified from the prospectively collected Cardiothoracic Register at The Prince Charles Hospital, Brisbane, Australia. All patients were followed up echocardiographically and clinically. The primary end-point was death, and a Cox proportional model was used to identify factors associated.with survival. Secondary end-points were valve-related morbidity (as defined by STS guidelines) and postoperative morbidity. Predictors of morbidity were identified using logistic regression. A total of 246 patients (mean age 50 years) was included in the study. The overall mortality was 12%, with actuarial 10-year survival 79% and a 10-year estimate of valve-related death of 0.04 (95% CI: 0.004, 0.07). Preoperative myocardial infarction (p = 0.004, HR 4.74), urgency of operation (p = 0.038, HR 2.8) and 10% incremental decreases in ejection fraction (p = 0.046, HR 0.69) were predictive of mortality. Survival was also affected by the valve gradients, with a unit increase in peak gradient reducing mortality (p = 0.021, HR 0.93). Valve-related morbidity occurred in 11 patients. Urgent surgery (p <0.001, OR 4.12), aortic dissection (p = 0.015, OR 3.35), calcific aortic stenosis (p = 0.016, OR 2.35) and Marfan syndrome (p 0.009, OR 3.75) were predictive of postoperative morbidity. The reoperation rate was 1.2%. The Medtronic Open Pivot valved conduit is a safe and durable option for aortic root replacement, and is associated with low morbidity and 10-year survival of 79%. However, further studies are required to determine the effect of valve gradient on survival.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and aim of the study: The quantification of incidentally found aortic valve calcification on computed tomography (CT) is not performed routinely, as data relating to the accuracy of aortic valve calcium for estimating the severity of aortic stenosis (AS) is neither consistent nor validated. As aortic valve calcium quantification by CT is confounded by wall and coronary ostial calcification, as well as motion artifact, the ex-vivo micro-computed tomography (micro-CT) of stenotic aortic valves allows a precise measurement of the amounts of calcium present. The study aim, using excised aortic valves from patients with confirmed AS, was to determine if the amount of calcium on micro-CT correlated with the severity of AS. Methods: Each of 35 aortic valves that had been excised from patients during surgical valve replacement were examined using micro-CT imaging. The amount of calcium present was determined by absolute and proportional values of calcium volume in the specimen. Subsequently, the correlation between calcium volume and preoperative mean aortic valve gradient (MAVG), peak transaortic velocity (V-max), and aortic valve area (AVA) on echocardiography, was evaluated. Results: The mean calcium volume across all valves was 603.2 +/- 398.5 mm(3), and the mean ratio of calcium volume to total valve volume was 0.36 +/- 0.16. The mean aortic valve gradient correlated positively with both calcium volume and ratio (r = 0.72, p <0.001). V-max also correlated positively with the calcium volume and ratio (r = 0.69 and 0.76 respectively; p <0.001). A logarithmic curvilinear model proved to be the best fit to the correlation. A calcium volume of 480 mm(3) showed sensitivity and specificity of 0.76 and 0.83, respectively, for a diagnosis of severe AS, while a calcium ratio of 0.37 yielded sensitivity and specificity of 0.82 and 0.94, respectively. Conclusion: A radiological estimation of calcium amount by volume, and its proportion to the total valve volume, were shown to serve as good predictive parameters for severe AS. An estimation of the calcium volume may serve as a complementary measure for determining the severity of AS when aortic valve calcification is identified on CT imaging. The Journal of Heart Valve Disease 2012;21:320-327

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Anticoagulantes orais são amplamente indicados para prevenção de eventos tromboembólicos. No entanto, nem sempre os pacientes atingem a faixa terapêutica recomendada. Os objetivos desse estudo foram avaliar a associação entre periodontite e níveis de anticoagulação (fase 1) e o efeito do tratamento periodontal nos níveis de anticoagulação (fase 2) em pacientes que faziam uso do anticoagulante oral varfarina. O exame clínico incluiu índice CPO-D, índice de placa, sangramento à sondagem, profundidade de bolsa e nível de inserção clínica. Coeficiente normalizado internacional (INR), níveis de albumina, proteína C-reativa (PCR) e fibrinogênio foram avaliados no dia zero e até 180 dias após tratamento periodontal. Na fase 1 do estudo foram examinados 62 pacientes (42 mulheres e 20 homens, com idade média de 50,8 9,2 anos). Observamos uma correlação negativa entre extensão e severidade da doença periodontal e índice de placa com valores de INR. Não houve associação entre diagnóstico periodontal e níveis de anticoagulação. Dentre os pacientes fora do alvo terapêutico, 87% apresentavam diagnóstico de periodontite, enquanto no grupo na faixa terapêutica apenas 56%. Participaram da fase 2 do estudo 26 pacientes com periodontite severa (15 mulheres e 11 homens, com idade média de 51,3 9,2 anos). O tratamento periodontal resultou em melhora significativa de todos os parâmetros periodontais e dos níveis de anticoagulação 30, 60 90 e 180 dias após conclusão da terapia periodontal. Não houve alteração significativa na dose semanal da varfarina. Foi observada redução significativa entre níveis séricos de albumina dos dia 90 e 180 após a terapia periodontal, quando comparado aos valores do dia 0 (p < 0,05). De acordo com o alvo terapêutico estabelecido, observamos que no dia 0 doze pacientes (46,15%) estavam fora dessa faixa. Esse percentual foi reduzido significativamente após tratamento periodontal, sendo 26,1% e 29,2% nos dias 60 e 90, respectivamente. Embora tenha ocorrido melhora nos níveis de anticoagulação, não houve alteração significativa nos níveis de PCR e fibrinogênio. Sendo assim, pacientes com periodontite severa podem apresentar dificuldade para atingir a faixa terapêutica e o tratamento periodontal pode resultar em benefícios na busca da anticoagulação plena. Novos estudos são necessários para avaliar se formas menos severas de doença periodontal também podem interferir com a varfarina.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Today, PCR using broad-range primers is being used increasingly to detect pathogens from resected heart valves. Herein is described the first case of multivalve infective endocarditis where 16S rDNA PCR was used to detect a single pathogen from two affected valves in a 61-year-old man. Triple heart valve replacement was required despite six weeks of appropriate antimicrobial therapy. The organism was confirmed as Streptococcus gallolyticus subsp. macedonicus, a member of the 'S. equinus/S. bovis' complex. To date, only one report has been made of human infection due to this organism. This may be due to the limited resolution of the routine diagnostic methods used and/or as a consequence of the complex nomenclature associated with this group of organisms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This is a case report of a 43-year-old Caucasian male with end-stage renal disease being treated with hemodialysis and infective endocarditis in the aortic and tricuspid valves. The clinical presentation was dominated by neurologic impairment with cerebral embolism and hemorrhagic components. A thoracoabdominal computerized tomography scan revealed septic pulmonary embolus. The patient underwent empirical antibiotherapy with ceftriaxone, gentamicin and vancomycin, and the therapy was changed to flucloxacilin and gentamicin after the isolation of S. aureus in blood cultures. The multidisciplinary team determined that the patient should undergo valve replacement after the stabilization of the intracranial hemorrhage; however, on the 8th day of hospitalization, the patient entered cardiac arrest due to a massive septic pulmonary embolism and died. Despite the risk of aggravation of the hemorrhagic cerebral lesion, early surgical intervention should be considered in high-risk patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Describir mediciones 3D y hallazgos estructurales de válvula mitral, en pacientes sanos, y con insuficiencia mitral grado 3 o 4, con enfermedad coronaria, patologías degenerativas o cardiopatía dilatada no isquémica, mediante uso de ecocardiografia transesofágica 3D en tiempo real.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVOS: Describir y comparar los cambios dinámicos de la geometría del anillo mitral durante todo el ciclo cardiaco en pacientes con insuficiencia mitral isquémica y pacientes con válvula mitral normal. MATERIALES Y MÉTODOS: Los estudios ecocardiográficos analizados fueron 37, 23 con insuficiencia mitral isquémica y 14 con válvula mitral normal. La reconstrucción del anillo se realizó en la estación de trabajo Xcelera (Philips Medial Systems) mediante la herramienta de análisis mitral (MVQ), en 5 momentos del ciclo cardiaco: Comienzo de Sístole, Mitad de Sístole, Final de Sístole, Mitad de Diástole y Final de Diástole. RESULTADOS: El anillo del grupo control, fue más dinámico, con sus menores dimensiones al final de la diástole, presentando incremento progresivo durante la sístole. Los cambios en el perímetro y el área, fueron significativos entre el comienzo y mitad de la sístole (p:0.087 y p: 0.055). En el grupo con insuficiencia mitral isquémica, el anillo fue más estático. Todas las dimensiones en este grupo, fueron mayores en los cinco momentos del ciclo cardiaco. (p < 0.1). El anillo también fue más plano, con un índice morfológico anular menor al del grupo control (p:0.087). DISCUSIÓN Y CONCLUSIONES: En pacientes sin insuficiencia mitral, el anillo es una estructura dinámica. Durante la sístole, las menores dimensiones se produjeron al comienzo de este periodo y la conformación en silla de montar se mantuvo, protegiendo contra la insuficiencia mitral. El anillo del grupo con insuficiencia mitral fue más estático y plano, perdiendo los mecanismos protectores.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objetivos: Identificar predictores de recuperación de la función ventricular izquierda y comparar los hallazgos ecocardiográficos en pacientes con estenosis aórtica crítica sometidos a reemplazo quirúrgico de la válvula aórtica (RVA) o implantación de válvula aórtica transcatéter (TAVI). Métodos: Cuarenta y cuatro pacientes tratados con RVA se compararon con 34 pacientes con TAVI, los datos ecocardiográficos fueron retrospectivamente obtenidos antes de la intervención y previo al alta. Resultados: Se analizaron retrospectivamente pacientes tratados en la FCI - IC desde 2009 - 2015 (n = 78 pacientes, con una media de edad 70,29 ± 11,63, EuroSCORE logístico 3,75 (3-8,55) en RVA y 20,4 (15 , 47-23,32) en TAVI. Ambos grupos mostraron una disminución en los gradientes de la válvula aórtica, más en pacientes de TAVI, con un gradiente transaórtico pico (24,5 vs 18,5, p = 0,001) y medio (14 vs 10, p = 0,002) En comparación con RVA, TAVI presentó un mayor número de pacientes con insuficiencia aórtica paravalvular (47,1% frente a 2,3% p = 0.000). En total, el 61,5% presentó mejoría precoz de la función ventricular, el predictor en severo compromiso de la función del ventrículo izquierdo fue un alto índice de masa ventricular izquierda. Conclusiones: La implantación transcatéter de válvula aórtica es una alternativa al reemplazo quirúrgico de la válvula aórtica en pacientes con estenosis aórtica y alto riesgo quirúrgico. La recuperación postoperatoria precoz de la función ventricular izquierda en pacientes con severo compromiso de la función ventricular estuvo asociada a alto índice de masa ventricular izquierda.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción: A partir de la década de los cincuenta el manejo de la enfermedad valvular presenta cambios significativos cuando se incorporan los reemplazos valvulares tanto mecánicos como biológicos dentro de las opciones de tratamiento quirúrgico (1). Las válvulas biológicas se desarrollaron como una alternativa que buscaba evitar los problemas relacionados con la anticoagulación y con la idea de utilizar un tejido que se comportara hemodinámicamente como el nativo. Este estudio está enfocado en establecer la sobrevida global y la libertad de reoperación de la válvula de los pacientes sometidos a reemplazo valvular aórtico y mitral biológicos en la Fundación Cardioinfantil - IC a 1, 3, 5 y 10 años. Materiales y métodos: Estudio de cohorte retrospectiva de supervivencia de pacientes sometidos a reemplazo valvular aórtico y/o mitral biológico intervenidos en la Fundación Cardioinfantil entre 2005 y 2013. Resultados: Se obtuvieron 919 pacientes incluidos en el análisis general y 876 (95,3%) pacientes con seguimiento efectivo para el análisis de sobrevida. La edad promedio fue 64años. La sobrevida a 1, 3, 5 y 10 años fue 95%,90%,85% y 69% respectivamente. El seguimiento efectivo para el desenlace reoperación fue del 55% y se encontró una libertad de reoperación del 99%, 96%, 93% y 81% a los 1, 3, 5 y 10 años. No hubo diferencias significativas entre la localización de la válvula ni en el tipo de válvula aortica empleada. Conclusiones: La sobrevida de los pacientes que son llevados a reemplazo valvular biológico en este estudio es comparable a grandes cohortes internacionales. La sobrevida de los pacientes llevados a reemplazo valvular con prótesis biológicas en posición mitral y aortica fue similar a 1, 3, 5 y 10 años.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article describes a solid-state NMR (SSNMR) investigation of the influence of hydration and chemical cross-linking on the molecular dynamics of the constituents of the bovine pericardium (BP) tissues and its relation to the mechanical properties of the tissue. Samples of natural phenetylamine-diepoxide (DE)- and glutaraldehyde (GL)-fixed BP were investigated by (13)C cross-polarization SSNMR to probe the dynamics of the collagen, and the results were correlated to the mechanical properties of the tissues, probed by dynamical mechanical analysis. For samples of natural BP, the NMR results show that the higher the hydration level the more pronounced the molecular dynamics of the collagen backbone and sidechains, decreasing the tissue`s elastic modulus. In contrast, in DE- and GL-treated samples, the collagen molecules are more rigid, and the hydration seems to be less effective in increasing the collagen molecular dynamics and reducing the mechanical strength of the samples. This is mostly attributed to the presence of cross-links between the collagen plates, which renders the collagen mobility less dependent on the water absorption in chemically treated samples. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The immersed boundary method is a versatile tool for the investigation of flow-structure interaction. In a large number of applications, the immersed boundaries or structures are very stiff and strong tangential forces on these interfaces induce a well-known, severe time-step restriction for explicit discretizations. This excessive stability constraint can be removed with fully implicit or suitable semi-implicit schemes but at a seemingly prohibitive computational cost. While economical alternatives have been proposed recently for some special cases, there is a practical need for a computationally efficient approach that can be applied more broadly. In this context, we revisit a robust semi-implicit discretization introduced by Peskin in the late 1970s which has received renewed attention recently. This discretization, in which the spreading and interpolation operators are lagged. leads to a linear system of equations for the inter-face configuration at the future time, when the interfacial force is linear. However, this linear system is large and dense and thus it is challenging to streamline its solution. Moreover, while the same linear system or one of similar structure could potentially be used in Newton-type iterations, nonlinear and highly stiff immersed structures pose additional challenges to iterative methods. In this work, we address these problems and propose cost-effective computational strategies for solving Peskin`s lagged-operators type of discretization. We do this by first constructing a sufficiently accurate approximation to the system`s matrix and we obtain a rigorous estimate for this approximation. This matrix is expeditiously computed by using a combination of pre-calculated values and interpolation. The availability of a matrix allows for more efficient matrix-vector products and facilitates the design of effective iterative schemes. We propose efficient iterative approaches to deal with both linear and nonlinear interfacial forces and simple or complex immersed structures with tethered or untethered points. One of these iterative approaches employs a splitting in which we first solve a linear problem for the interfacial force and then we use a nonlinear iteration to find the interface configuration corresponding to this force. We demonstrate that the proposed approach is several orders of magnitude more efficient than the standard explicit method. In addition to considering the standard elliptical drop test case, we show both the robustness and efficacy of the proposed methodology with a 2D model of a heart valve. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUÇÃO: Dados da literatura sugerem que as taxas de tromboembolismo e sangramento em pacientes com próteses valvares cardíacas mecânicas podem ser muito reduzidas se a terapia anticoagulante for otimizada. OBJETIVOS: Avaliar a ocorrência de complicações em portadores de próteses valvares cardíacas mecânicas submetidos à terapêutica anticoagulante, otimizada por meio de ambulatório especializado. MÉTODOS: Estudou-se a ocorrência de complicações ao longo de 10 anos em 261 pacientes com próteses valvares cardíacas mecânicas, anticoagulados e acompanhados em ambulatório especializado. Esses pacientes foram divididos em dois grupos conforme porcentual de consultas com tempo de protrombina (RNI) dentro do intervalo desejado: G1-0% a 50,00% e G2-50,01% a 100% das consultas. Foram avaliadas as ocorrências de complicações tromboembólicas e hemorrágicas na sua totalidade, ou subdivididas em maiores e menores, de acordo com a gravidade. Os resultados estão apresentados sob forma de estudo atuarial e de frequência linearizada de ocorrência de eventos. RESULTADOS: O estudo atuarial mostrou que, ao longo do tempo, no grupo G2 (com 50,01% a 100% das consultas com a RNI no intervalo desejado) maior número de pacientes esteve livre da ocorrência de qualquer tipo de evento, de eventos hemorrágicos menores ou da elevação exacerbada da RNI. As frequências linearizadas de ocorrência, em todos os tipos eventos, também foram menores nos pacientes do grupo G2. CONCLUSÕES: O tempo de permanência dentro do intervalo de anticoagulação desejado está diretamente relacionado com a ocorrência de complicações. Entretanto, mesmo com acompanhamento otimizado por meio de ambulatório especializado, apenas cerca de um terço dos pacientes apresentaram nível de anticoagulação adequado em mais da metade das consultas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and objectives: The introduction of extracorporeal circulation in clinical practice was decisive for the development of modern cardiovascular surgery. Addition of new procedures and equipment, however, brings inherent risks and complications. The objective of this report is to describe a malfunction of the oxygenation system and emphasize the importance of the interaction among the medical team members to prevent errors and complications. Case Report: During valve replacement and IVC correction surgery, we observed a darker shade of red in the blood on the exit of the oxygenator. Laboratory tests demonstrated severe acidosis and hypoxemia. The entire system was evaluated, but the cause of the malfunction was not found. Measures to reduce damage were successfully instituted. After the surgery, the whole system underwent technical evaluation. Conclusions: Interaction among the medical team members, early diagnosis, and immediate intervention were fundamental for a favorable outcome. © 2011 Elsevier Editora Ltda.