998 resultados para Hand - Surgery


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We studied an experimental model of resection arthroplasty with or without tendon ball interposition in the wrist of dogs. Animals were divided into two groups. Animals in group A were treated by resection of the os carpi radiale with interposition of a ball made from the tendon of the extensor carpi radialis and the group B underwent bone resection alone. Animals were assessed 1, 6, 12 and 24 weeks after operation. In all of them the wrist joint was stable and had good mobility, allowing walking supported by the operated limb. In both groups biological material filled the cavity created by bone resection. A progressive repair process resulted in fibroplasia with areas of fibrocartilaginous metaplasia. The tendon ball showed complete ischaemic necrosis at the end of the first week, which delayed the healing process. © 1999 The British Society for Surgery of the Hand.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose To compare changes in the largest cross-sectional area (CSA) of the median nerve in wrists undergoing surgical decompression with changes in wrists undergoing non-surgical treatment of carpal tunnel syndrome (CTS). Methods This study was a prospective cohort study in 55 consecutive patients with 78 wrists with established CTS, including 60 wrists treated with surgical decompression and 18 wrists with non-surgical treatment. A sonographic examination was scheduled before and 4 months after initiation of treatment. We compared changes in CSA of the median nerve between wrists with surgical treatment and wrists with non-surgical treatment using linear regression models. Results Decreases in CSA of the median nerve were more pronounced in wrists with CTS release than in wrists undergoing nonsurgical treatment (difference in means, 1.0 mm2; 95% confidence interval, 0.3–1.8 mm2). Results were robust to the adjustment for age, gender, and neurological severity at baseline. Among wrists with CTS release, those with postoperative CSA of 10 mm2 or less tended to have better clinical outcomes than those with postoperative CSA of greater than 10 mm2 (p=.055). Postoperative sonographic workup in the 3 patients with unfavorable outcome or recurrence identified likely causes for treatment failure in 2 patients. Conclusions In this observational study, surgical decompression was associated with a greater decrease in median nerve CSA than was nonsurgical treatment. Smaller postoperative CSAs may be associated with better clinical outcomes. Additional randomized trials are necessary to determine the optimal treatment strategy in different subgroups of patients with CTS. Type of study/level of evidence Therapeutic III.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

For nonsurgical treatment of fractures of the proximal phalanges of the triphalangeal fingers, different dynamic casts have been described. The main principle behind these casts is advancement and tightening of the extensor hood, caused by a combination of blocking the metacarpophalangeal joints in flexion and actively flexing the proximal interphalangeal joints. In contrast to established treatment protocols using functional forearm casts, the Lucerne cast allows for free mobilization of the wrist joint. The purpose of the current multicenter study was to compare the results of conservative, functional treatment using 2 different methods, either a forearm cast or a Lucerne cast.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To analyze functional and subjective outcomes of patients with posttraumatic dorsal instability of the distal radioulnar joint (DRUJ) treated by a dorsal capsular imbrication.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigates the results of a technique using an extensor carpi radialis longus (ECRL) tenodesis for symptomatic scapholunate instability. Symptomatic scapholunate instability has been corrected so far either by limited wrist fusion or by various techniques of soft tissue repair. Limited wrist fusion greatly reduces wrist motion and increases the probability of osteoarthritis in the remaining mobile wrist segments. On the other hand, most types of soft tissue repair are technically difficult to perform and have disappointing results due to the inherent laxity. The presented dynamic approach was used in 20 wrists of 19 patients with static scapholunate instability. Preoperative evaluation included in all patients clinical examination, radiologic evaluation, and arthroscopy for establishing the diagnosis of static scapholunate instability. The technique involves the fixation of the ECRL tendon on the dorsal aspect of the scaphoid by means of a cancellous screw and a special washer. Dynamic ECRL tenodesis of the scaphoid is a safe and simple procedure that enhances the extension forces on the scaphoid in all wrist positions. The results of this preliminary report in 20 wrists showed dynamic ECRL tenodesis to be an effective treatment option for treating symptomatic static scapholunate instability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Despite improved medical treatment of rheumatoid arthritis, carpal tunnel compression, caput ulnae syndrome and palmar and dorsal tenosynovitis with potential tendon rupture represent urgent surgical indications. While diagnostic and therapeutic synovectomy may guide medical treatment, it should be performed before joint instability and destructive arthritis are established. Swan-neck and Boutonniere deformities as well as ulnar or radial drift of metacarpophalangeal (MCP) joints or the wrist can only be corrected when the involved joints are supple and intact. In the presence of destructive arthritis, partial and total wrist fusion, arthroplasties of the MCP joints and arthrodeses of the distal interphalangeal joints are recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to compare GPX instruments and hand files for gutta-percha removal. Study design. Fifty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 5 groups of 10 specimens each, according to the gutta-percha removal techniques: group 1: GPX (21-mm-long teeth); group 2: GPX and xylol as solvent (21-mm-long teeth); group 3: GPX (25-mm-long teeth); group 4: GPX and xylol as solvent (25-mm-long teeth); and group 5: hand files and xylol as solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken, and the teeth were grooved longitudinally and split. The area of residual debris was measured using Sigma Scan software. Results. The time for filling material removal was significantly shorter when GPX was used (P < .05). Overall, hand files and solvent produced fewer remnants of filling materials (P < .05). In the GPX 25 mm-long teeth group, the filling material was not removed in the apical third. Conclusions. Under the experimental conditions, the GPX instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments left a smaller amount of residual filling materials on the canal walls. The GPX instruments did not pull the gutta-percha beyond its tip. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 675-680)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was undertaken to establish whether children with myelomeningocele have abnormal kinaesthesia of the hands. Twenty-one children with myelomeningocele and 21 control children, aged between six and 12 years, were involved in the study. The level of kinaesthetic awareness in the hands was measured by examining the child's ability to copy hand positions, using visual cueing and kinaesthetic cueing. Both accuracy and speed of copying hand gestures were assessed. Children with spina bifida were significantly less accurate in achieving hand positions than the control group (chi((1))(2) 22.60, p < 0.001), with 73% of the children with spina bifida achieving accurate replications compared with 87% in the control group. Furthermore, children with myelomeningocele were shown to be slower than the controls (F-(1,F-2810) = 15.49, p < 0.001). The impaired kinaesthetic awareness found in this study is considered to be one of the factors behind the poor hand function observed in children with myelomeningocele.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Presently the surgical approach to the adrenal gland is in a state of flux. While the traditional approach to the adrenal gland has been the open transabdominal technique, more recently laparoscopic approaches, particularly via the transabdominal route, have increasingly been utilized. However, laparoscopic intervention for the adrenal gland can be problematic in certain circumstances, particularly for large adrenal masses and in instances of adrenal malignancies. Methods: In this report we describe the use of hand-assisted laparoscopic adrenalectomy as an alternative minimal invasive surgical approach to the adrenal gland. Hand-assisted laparoscopic adrenalectomy using the HandPort system (Smith & Nephew, Sydney, Australia) was undertaken in three patients requiring adrenalectomy for mass lesions including one patient with Conn's syndrome. Results: In all three cases, surgery proceeded promptly and uneventfully. In the present paper, the details of the technique of hand-assisted adrenalectomy are described. This is the first report in the world literature of this new technique for the adrenal gland. Conclusions: Hand-assisted laparoscopic adrenalectomy is an easily performed technique, which can be completed within a short operative time span and which has the advantage of providing intraoperative tactile localization for the adrenal gland. It may be particularly applicable for large adrenal tumours, yet only involves the performance of a small abdominal incision. Postoperative recovery is comparable with that reported for the laparoscopic-only technique. Hand-assisted adrenalectomy is a new technique which has great potential and which warrants further evaluation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.