The need for increasing the loading capacity of transmission lines in a traditional way, by replacing or reinforcement of the structures and foundations on routes crossing areas considered of permanent environmental preservation, may require additional works that alter the environment. The present rigorous environmental legislation turns these changes and substitution unfeasible. One way to increase the capacity of these lines is the use of new conductor technology. The aim of this paper is to discuss the needs for upgrading a transmission line and minimize or eliminate the damage to the environment by using special conductors. Because the aluminum conductor composite reinforced technology is relatively new and considering the lack of information related to its effective performance in practical system, there is a need to verify the behavior of these conductors through monitoring procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tecnologias HVDC que utilizam conversores do tipo fonte de tensão, o VSC-HVDC, ainda não são completamente difundidas e aplicadas no Brasil, em contraste com outros países que começaram a estudar e empregar este tipo de transmissão. Comparado com o HVDC tradicional, o VSC-HVDC é uma tecnologia de transmissão mais eficiente e pode superar deficiências encontradas na transmissão em corrente contínua convencional. O VSC-HVDC pode ser utilizado de maneira mais eficiente nas novas redes de energia, para alimentar ilhas, integração de geração eólica, renovação das linhas em centros urbanos, aplicações multiterminais e conexão com sistemas fracos. Por se tratar de uma tecnologia recente, o VSC-HVDC ainda não é amplamente adotado e uma das principais limitações da utilização destes sistemas é a sua fragilidade diante faltas na linha de corrente contínua. Neste contexto, limitadores de corrente de falta (LCF) podem ser utilizados para minimizar o impacto das faltas. A ação dos limitadores é benéfica ao sistema durante condições de falta, contudo, ainda assim é necessária a atuação do sistema de proteção para extinguir a condição faltosa. Portanto, este trabalho visa propor e avaliar um novo esquema de proteção que opere de maneira seletiva e confiável para sistemas VSC-HVDC na presença de LCF baseados em materiais supercondutores ou LCF indutivos. Para tanto, foram implementadas quatro funções de proteção tradicionais das linhas em CC, a saber: direcional de corrente, diferencial, sobrecorrente com restrição de tensão e ondas viajantes, e ainda, foi proposta uma nova função de proteção, a de condutância, a qual apresentou o menor tempo de identificação de falta, considerando as faltas mais severas. Adicionalmente, foi avaliado o comportamento destas funções quando o sistema apresenta os LCF em série com a linha. Foi demonstrado que é possível extrair os benefícios dos LCF sem deteriorar a qualidade dos resultados das funções de proteção, o que aumenta a segurança e confiabilidade dos sistemas VSC-HVDC, uma vez que os impactos das faltas são minimizados e as mesmas são identificadas em um curto intervalo de tempo.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

VSC converters are becoming more prevalent for HVDC applications. Two circuits are commercially available at present, a traditional six-switch, PWM inverter, implemented using series connected IGBTs - ABBs HVDC Light®, and the other a modular multi-level converter (MMC) - Siemens HVDC-PLUS. This paper presents an alternative MMC topology, which utilises a novel current injection technique, and exhibits several desirable characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

DC distribution and transmission provides an efficient, cost effective and reliable alternative to traditional AC systems for offshore wind farm integration. High power DC-DC converters are key components to realise future offshore voltage DC grids and multi-terminal HVDC systems. Different DC-DC converter topologies have been proposed for this application. The aim of this paper is to investigate the viability of Switched Capacitor (SC) converters in high power application particularly the interconnection of offshore windfarms to a medium voltage DC grid. In addition, a comparison of alternative topologies that have been proposed will be presented. Simulation and experimental results are provided to verify the analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-power and high-voltage gain dc-dc converters are key to high-voltage direct current (HVDC) power transmission for offshore wind power. This paper presents an isolated ultra-high step-up dc-dc converter in matrix transformer configuration. A flyback-forward converter is adopted as the power cell and the secondary side matrix connection is introduced to increase the power level and to improve fault tolerance. Because of the modular structure of the converter, the stress on the switching devices is decreased and so is the transformer size. The proposed topology can be operated in column interleaved modes, row interleaved modes, and hybrid working modes in order to deal with the varying energy from the wind farm. Furthermore, fault-tolerant operation is also realized in several fault scenarios. A 400-W dc-dc converter with four cells is developed and experimentally tested to validate the proposed technique, which can be applied to high-power high-voltage dc power transmission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hand hygiene is critical in the healthcare setting and it is believed that methicillin-resistant Staphylococcus aureus (MRSA), for example, is transmitted from patient to patient largely via the hands of health professionals. A study has been carried out at a large teaching hospital to estimate how often the gloves of a healthcare worker are contaminated with MRSA after contact with a colonized patient. The effectiveness of handwashing procedures to decontaminate the health professionals' hands was also investigated, together with how well different healthcare professional groups complied with handwashing procedures. The study showed that about 17% (9–25%) of contacts between a healthcare worker and a MRSA-colonized patient results in transmission of MRSA from a patient to the gloves of a healthcare worker. Different health professional groups have different rates of compliance with infection control procedures. Non-contact staff (cleaners, food services) had the shortest handwashing times. In this study, glove use compliance rates were 75% or above in all healthcare worker groups except doctors whose compliance was only 27%.