60 resultados para HVDC


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of an advanced outdoor valve requires coordinated research in the areas of light-triggered self-protecting thyristors, light triggering systems, insulation, cooling and mechanical design aspects. This thesis addresses the first two areas primarily, with a conceptual discussion of the remainder. Using the experience gained from evaluation of a prototype thyristor and computer IKdelling of turn-on behaviour, a light-triggered thyristor with immunity to damage from weak optical triggering and dv/dt triggering was designed, manufactured and evaluated. The optical turn-on process was investigated by measuring currents and voltages in the gate structure during turn-on, and this yielded insights not obtained through conventional measurement techniques. The mechanism by which the thyristor was immune to weak triggering damage is explained, and techniques for optimising the design of the gate structure are proposed. The most significant achievement, however, was the first demonstration of the feasibility of self-protection against forward recovery failure onditions. Furthermore, this was achieved without the need for complex structures or high levels of irradiation. The perfomance of the devices was limited by the inrush capability of the Zones, but it is believed that this can be improved by conventional means. A light triggering system was developed using sem~conductor lasers, and this incorporated several improvements over prior art In terms of optical performance and flexibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

VSC converters are becoming more prevalent for HVDC applications. Two circuits are commercially available at present, a traditional six-switch, PWM inverter, implemented using series connected IGBTs - ABBs HVDC Light®, and the other a modular multi-level converter (MMC) - Siemens HVDC-PLUS. This paper presents an alternative MMC topology, which utilises a novel current injection technique, and exhibits several desirable characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter discusses network protection of high-voltage direct current (HVDC) transmission systems for large-scale offshore wind farms where the HVDC system utilizes voltage-source converters. The multi-terminal HVDC network topology and protection allocation and configuration are discussed with DC circuit breaker and protection relay configurations studied for different fault conditions. A detailed protection scheme is designed with a solution that does not require relay communication. Advanced understanding of protection system design and operation is necessary for reliable and safe operation of the meshed HVDC system under fault conditions. Meshed-HVDC systems are important as they will be used to interconnect large-scale offshore wind generation projects. Offshore wind generation is growing rapidly and offers a means of securing energy supply and addressing emissions targets whilst minimising community impacts. There are ambitious plans concerning such projects in Europe and in the Asia-Pacific region which will all require a reliable yet economic system to generate, collect, and transmit electrical power from renewable resources. Collective offshore wind farms are efficient and have potential as a significant low-carbon energy source. However, this requires a reliable collection and transmission system. Offshore wind power generation is a relatively new area and lacks systematic analysis of faults and associated operational experience to enhance further development. Appropriate fault protection schemes are required and this chapter highlights the process of developing and assessing such schemes. The chapter illustrates the basic meshed topology, identifies the need for distance evaluation, and appropriate cable models, then details the design and operation of the protection scheme with simulation results used to illustrate operation. © Springer Science+Business Media Singapore 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DC distribution and transmission provides an efficient, cost effective and reliable alternative to traditional AC systems for offshore wind farm integration. High power DC-DC converters are key components to realise future offshore voltage DC grids and multi-terminal HVDC systems. Different DC-DC converter topologies have been proposed for this application. The aim of this paper is to investigate the viability of Switched Capacitor (SC) converters in high power application particularly the interconnection of offshore windfarms to a medium voltage DC grid. In addition, a comparison of alternative topologies that have been proposed will be presented. Simulation and experimental results are provided to verify the analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-power and high-voltage gain dc-dc converters are key to high-voltage direct current (HVDC) power transmission for offshore wind power. This paper presents an isolated ultra-high step-up dc-dc converter in matrix transformer configuration. A flyback-forward converter is adopted as the power cell and the secondary side matrix connection is introduced to increase the power level and to improve fault tolerance. Because of the modular structure of the converter, the stress on the switching devices is decreased and so is the transformer size. The proposed topology can be operated in column interleaved modes, row interleaved modes, and hybrid working modes in order to deal with the varying energy from the wind farm. Furthermore, fault-tolerant operation is also realized in several fault scenarios. A 400-W dc-dc converter with four cells is developed and experimentally tested to validate the proposed technique, which can be applied to high-power high-voltage dc power transmission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lo studio intrapreso si è posto come obiettivo la caratterizzazione dal punto di vista elettrico dei materiali coinvolti nella realizzazione di accessori per applicazioni in HVDC, in particolare mescole isolanti, semiconduttive e varioresistive. La necessità di un lavoro di questo tipo viene giustificata dalla costante espansione dei sistemi in DC nella trasmissione dell’energia elettrica, i quali presentano caratteristiche fisiche che si differenziano sensibilmente da quelle tipiche dei tradizionali sistemi in AC, dunque richiedono componenti e materiali opportunamente progettati per garantire condizioni di servizio sicure e affidabili. L’obiettivo della trattazione consiste nello studio di analogie e differenze tra le proprietà elettriche fornite da prove su diverse configurazioni di provini, nella fattispecie di tipo piano e cilindrico cavo. In primo luogo si studiano i provini di tipo piano al fine di ricavare informazioni basilari sul materiale e sulla mescola che lo costituisce e di prendere decisioni relative al proseguimento dei test. Dopo aver effettuato un sufficiente numero di test su varie tipologie di provini piani e aver riconosciuto le mescole più performanti dal punto di vista elettrico, meccanico e termico, si procede alla realizzazione di provini cilindrici stampati, su cui si intraprendono le medesime misure effettuate per la configurazione piana. Questa seconda fase di caratterizzazione è fondamentale, in quanto consente di verificare che le proprietà già studiate su piastra si conservino in una geometria molto più simile a quella assunta dal prodotto finale evitando di sostenere costi onerosi per la produzione di un accessorio full-size. Il lavoro è stato svolto nel laboratorio elettrico di alta tensione della divisione R&D del gruppo Prysmian di Milano, leader mondiale nella produzione di sistemi in cavo per alte e altissime tensioni.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An integrated mathematical model for the simulation of an offshore wind system performance is presented in this paper. The mathematical model considers an offshore variable-speed turbine in deep water equipped with a permanent magnet synchronous generator using multiple point full-power clamped three-level converter, converting the energy of a variable frequency source in injected energy into the electric network with constant frequency, through a HVDC transmission submarine cable. The mathematical model for the drive train is a concentrate two mass model which incorporates the dynamic for the blades of the wind turbine, tower and generator due to the need to emulate the effects of the wind and the floating motion. Controller strategy considered is a proportional integral one. Also, pulse width modulation using space vector modulation supplemented with sliding mode is used for trigger the transistors of the converter. Finally, a case study is presented to access the system performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modern power systems have become more complex due to the growth in load demand, the installation of Flexible AC Transmission Systems (FACTS) devices and the integration of new HVDC links into existing AC grids. On the other hand, the introduction of the deregulated and unbundled power market operational mechanism, together with present changes in generation sources including connections of large renewable energy generation with intermittent feature in nature, have further increased the complexity and uncertainty for power system operation and control. System operators and engineers have to confront a series of technical challenges from the operation of currently interconnected power systems. Among the many challenges, how to evaluate the steady state and dynamic behaviors of existing interconnected power systems effectively and accurately using more powerful computational analysis models and approaches becomes one of the key issues in power engineering. The traditional computing techniques have been widely used in various fields for power system analysis with varying degrees of success. The rapid development of computational intelligence, such as neural networks, fuzzy systems and evolutionary computation, provides tools and opportunities to solve the complex technical problems in power system planning, operation and control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Major advances in power electronics during recent years have prompted considerable interest within the traction community. The capability of new technologies to reduce the AC railway networks' effect on power quality and improve their supply efficiency is expected to significantly decrease the cost of electric rail supply systems. Of particular interest are Static Frequency Converter (SFC), Rail Power Conditioner (RPC), High Voltage Direct Current (HVDC) and Energy Storage Systems (ESS) solutions. Substantial impacts on future feasibility of railway electrification are anticipated. Aurizon, Australia's largest heavy haul railway operator, has recently commissioned the world's first 50Hz/50Hz SFC installation and is currently investigating SFC, RPC, HVDC and ESS solutions. This paper presents a summary of current and emerging technologies with a particular focus on the potential techno-economic benefits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the analysis and study of voltage collapse at any converter bus in A C-DC systems considering the dynamics of DC system. The problem of voltage instability is acute when HVDC links are connected to weak AC systems, the strength determined by short circuit ratio (SCR) at the converter bus. The converter control strategies are important in determining voltage instability. Small signal analysis is used to identify critical modes and evaluate the effect of AC system strength and control parameters. A sample two-terminal DC system is studied and the results compared with those obtained from static analysis. Also, the results obtained from small signal analysis are validated with nonlinear simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Trench Insulated Gate Bipolar Transistor (IGBT) is the most promising structure for the next generation of power semiconductor devices with wide applications ranging from motor control (1-4 kV) to HVDC (6.5 kV). Here we present for the first time an optimum design of a 1.4kV Trench IGBT using a new, fully integrated optimisation system comprising process and device simulators and the RSM optimiser. The use of this new TCAD system has contributed largely to realizing devices with characteristics far superior to the previous DMOS generation of IGBTs. Full experimental results on 1.4kV Trench IGBTs which are in excellent agreement with the TCAD predictions are reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

DC line faults on high-voltage direct current (HVDC) systems utilising voltage source converters (VSCs) are a major issue for multi-terminal HVDC systems in which complete isolation of the faulted system is not a viable option. Of these faults, single line-to-earth faults are the most common fault scenario. To better understand the system under such faults, this study analyses the behaviour of HVDC systems based on both conventional two-level converter and multilevel modular converter technology, experiencing a permanent line-to-earth fault. Operation of the proposed system under two different earthing configurations of converter side AC transformer earthed with converter unearthed, and both converter and AC transformer unearthed, was analysed and simulated, with particular attention paid to the converter operation. It was observed that the development of potential earth loops within the system as a result of DC line-to-earth faults leads to substantial overcurrent and results in oscillations depending on the earthing configuration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wind power is one of the most developed renewable energy resources worldwide. To integrate offshore wind farms to onshore grids, the high-voltage direct current (HVDC) transmission cables interfaced with voltage source converters (VSCs) are considered to be a better solution than conventional approaches. Proper DC voltage indicates successive power transfer. To connect more than one onshore grid, the DC voltage droop control is one of the most popular methods to share the control burden between different terminals. However, the challenges are that small droop gains will cause voltage deviations, while higher droop gain settings will cause large oscillations. This study aims to enhance the performance of the traditional droop controller by considering the DC cable dynamics. Based on the backstepping control concept, DC cables are modelled with a series of capacitors and inductors. The final droop control law is deduced step-by-step from the original remote side. At each step the control error from the previous step is considered. Simulation results show that both the voltage deviations and oscillations can be effectively reduced using the proposed method. Further, power sharing between different terminals can be effectively simplified such that it correlates linearly with the droop gains, thus enabling simple yet accurate system operation and control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Distributed control techniques can allow Transmission System Operators (TSOs) to coordinate their responses via TSO-TSO communication, providing a level of control that lies between that of centralised control and communication free decentralised control of interconnected power systems. Recently the Plug and Play Model Predictive Control (PnPMPC) toolbox has been developed in order to allow practitioners to design distributed controllers based on tube-MPC techniques. In this paper, some initial results using the PnPMPC toolbox for the design of distributed controllers to enhance AGC in AC areas connected to Multi-Terminal HVDC (MTDC) grids, are illustrated, in order to evaluate the feasibility of applying PnPMPC for this purpose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the use of primary frequency response metrics to assess the dynamics of frequency disturbance data with the presence of high system non synchronous penetration (SNSP) and system inertia variation. The Irish power system has been chosen as a study case as it experiences a significant level of SNSP from wind turbine generation and imported active power from HVDC interconnectors. Several recorded actual frequency disturbances were used in the analysis. These data were measured and collected from the Irish power system from October 2010 to June 2013. The paper has shown the impact of system inertia and SNSP variation on the performance of primary frequency response metrics, namely: nadir frequency, rate of change of frequency, inertial and primary frequency response.