187 resultados para HDR BRACHYTHERAPY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: There are few data on long-term clinical results and tolerance of brachytherapy in anal canal cancer. We present one of the largest retrospective analyses of anal canal cancers treated with external beam radiotherapy with/without (±) chemotherapy followed by a brachytherapy boost. MATERIALS AND METHODS: We performed a retrospective analysis of clinical results in terms of efficacy and toxicity. The impact of different clinical and therapeutic variables on these outcomes was studied. RESULTS: From May 1992 to December 2009, 209 patients received brachytherapy after external beam radiotherapy ± chemotherapy. Of these patients, 163 were stage II or stage IIIA (UICC 2002) and 58 were N1-3. According to age, ECOG performance status (PS), and comorbidities, patients received either radiotherapy alone (58/209) or radiochemotherapy (151/209). The median follow-up was 72.8 months. The 5- and 10-year local control rates were 78.6 and 73.9 %, respectively. Globally, severe acute and late G3-4 reactions (NCI-CTC scale v. 4.0) occurred in 11.2 and 6.3 % of patients, respectively. Univariate analysis showed the statistical impact of the pelvic treatment volume (p = 0.046) and of the total dose (p = 0.02) on the risk of severe acute and late toxicities, respectively. Only six patients required permanent colostomy because of severe late anorectal toxicities. CONCLUSION: After a long follow-up time, brachytherapy showed an acceptable toxicity profile and high local control rates in patients with anal canal cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravascular brachytherapy with beta sources has become a useful technique to prevent restenosis after cardiovascular intervention. In particular, the Beta-Cath high-dose-rate system, manufactured by Novoste Corporation, is a commercially available 90Sr 90Y source for intravascular brachytherapy that is achieving widespread use. Its dosimetric characterization has attracted considerable attention in recent years. Unfortunately, the short ranges of the emitted beta particles and the associated large dose gradients make experimental measurements particularly difficult. This circumstance has motivated the appearance of a number of papers addressing the characterization of this source by means of Monte Carlo simulation techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the relationship between two year PSA nadir (PSAn) after brachytherapy and biochemical recurrence rates in prostate cancer patients. Materials and Methods In the period from January 1998 to August 2007, 120 patients were treated with iodine-125 brachytherapy alone. The results analysis was based on the definition of biochemical recurrence according to the Phoenix Consensus. Results Biochemical control was observed in 86 patients (71.7%), and biochemical recurrence, in 34 (28.3%). Mean PSAn was 0.53 ng/ml. The mean follow-up was 98 months. The patients were divided into two groups: group 1, with two year PSAn < 0.5 ng/ml after brachytherapy (74 patients; 61.7%), and group 2, with two year PSAn ≥ 0.5 ng/ml after brachytherapy (46 patients; 38.3%). Group 1 presented biochemical recurrence in 15 patients (20.3%), and group 2, in 19 patients (43.2%) (p < 0.02). The analysis of biochemical disease-free survival at seven years, stratified by the two groups, showed values of 80% and 64% (p < 0.02), respectively. Conclusion Levels of two year PSAn ≥ 0.5 ng/ml after brachytherapy are strongly correlated with a poor prognosis. This fact may help to identify patients at risk for disease recurrence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Especialidad en Ingeniería Química) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho relata um caso clínico de carcinoma escamo celular cutâneo em um cão da raça Weimaraner, fêmea, 8 anos de idade tratado utilizando-se braquiterapia com folhas de Ouro-198. Os objetivos deste relato foram: avaliar o uso de um molde radioativo confeccionado para uso veterinário e sua eficácia no tratamento de um tumor de pele em cão. O método demonstrou ser eficaz no tratamento do tumor, mostrou ser uma prática segura para a equipe profissional envolvida, com baixos custos e resultado radiobiológico superior quando comparado com o tratamento padrão utilizado com outros elementos radioativos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors presents a clinical case treated with brachytherapy performed with special mold of gold-198 disc, with the purpose of evaluating the distribution of radiation dose, the viability of manufacturing the radioactivity prosthesis and its operational cost. In despite of being only one case, we can conclude that the prosthesis with gold-198 foils can be manufactured in acrylic with thickness thinner than those ones with cylinder of cesium-137, resulting lower operational costs, besides permitting better distribution of radiation dose on the lesion. (C) 1999 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The brachytherapy braquiterapia is an x-ray modality radiotherapy in which stamped or halfstamped radioactive sources in format of seeds are used, wires or to one short distance, in contact or implanted to the fabric to be treated. All the treatment modalities require a previous planning. The formalism recommended for calculation of dose was considered by the AAPM for the first TG-43 Report. In it distributions of dose of isolated seeds measured and calculated by Monte Carlo method in water instead of with models half-empiricists. In this work we in accordance with present some preliminary results of the calculation of functions of radial anisotropy and of dose in the distance for seed of 192Ir, wide used in brachytherapy treatments of high tax of dose (HDR), with the aid of the program based on the Monte Carlo method MCNPX v2.50 (Mount Carlo N ParticleeXtended). The materials chosen in the simulation beyond water, had been MS20 and estriado muscle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The brachytherapy braquiterapia is an x-ray modality radiotherapy in which stamped or halfstamped radioactive sources in format of seeds are used, wires or to one short distance, in contact or implanted to the fabric to be treated. All the treatment modalities require a previous planning.The formalism recommended for calculation of dose was considered by the AAPM for the first TG-43 Report. In it distributions of dose of isolated seeds measured and calculated by Monte Carlo method in water instead of with models half-empiricists.In this work we in accordance with present some preliminary results of the calculation of functions of radial anisotropy and of dose in the distance for seed of 192Ir, wide used in brachytherapy treatments of high tax of dose (HDR), with the aid of the program based on the Monte Carlo method MCNPX v2.50 (Mount Carlo N ParticleeXtended).The materials chosen in the simulation beyond water, had been MS20 and estriado muscle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brachytherapy is an adequate option as monotherapy for localised prostate cancer. The objective of this study was to evaluate and compare biochemical failure free survival (BFFS) after low-dose-rate brachytherapy (LDRB) alone for patients with prostate cancer using ASTRO and Phoenix criteria, and detect prognostic factors. Data on 220 patients treated between 1998 and 2002 with LDRB were retrospectively analysed. Neoadjuvant hormone therapy was used in 74 (33.6%) patients. Median follow-up was 53.5 months (24-116). Five year BFFS was 83.0% and 83.7% using, respectively, the ASTRO and Phoenix criteria. Low -and intermediate-risk patients presented, respectively, 86.7% and 77.8% 5-year BFFS using the ASTRO definition (p=0.069), and 88.5% and 78.6% considering the Phoenix criteria (p=0.016). Bounce was observed in 66 (30%) patients. Multivariate analysis detected PSA at diagnosis < 10 ng/ml and less than 50% positive biopsy fragments as favourable prognostic factors, regarding BF using both criteria. For the Phoenix criteria, also Gleason score < 7 and low-risk group were identified as independent favourable prognostic factors. LDRB alone should be considered mostly for low-risk patients. PSA level was a strong independent prognostic factor. We support the use of the Phoenix criteria for detection of BF in patients submitted to LDRB alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 2-year-old boy with syndromic bilateral retinoblastoma resulting from a (del(13)(q12.3q14.3)) developed a recurrent tumor measuring 2.3 X 2.3 mm at the ora serrata 15 months following last treatment.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. METHODS AND MATERIALS: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. RESULTS: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). CONCLUSIONS: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.