971 resultados para Glaucoma primário de ângulo aberto


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main thesis to be demonstrated in this work is that cognitive enhancement through the use of drugs can be included as a primary good within Rawls' thinking. To develop such notion, the text is structured in two parts. The first part intends to describe the theory of justice as equity in its elements directly related to primary goods. The first information to be verified is the unity of the notion of primary goods in all of Rawls' work. Some elements are modified, for example the distinction of natural and social primary goods. Natural primary goods are intelligence, health, imagination, vigor and chance (luck) and social primary goods are law and liberty, opportunity and power, income and wealth and the social fundaments of self-respect. The perception of some talents such as intelligence has also undergone changes, being altered from "higher intelligence" to "educated intelligence". Such fact highlights education as a primary good that permeates all of Rawls' work in different perspectives. Freedom and self-respect are social-primary goods that will also be deepened. The second part presents the definition of improvement and as to show that the distinction between enhancement and treatment is controversial. The part presents the definition of improvement and as the distinction between enhancement and treatment is controversial. Thus, we have deepened the problems related to practice improvement (enhancement) showing how the concepts of Rawls' primary goods as freedom and self-respect are not in opposition to the practice of improvement, particularly cognitive enhancement. We have shown, instead, that the ban of cognitive improvement could lead to denial of these primary goods. But how could we consider cognitive improvement as a primary social good? What we have done in this thesis is to show how cognitive enhancement is important to ensure that primary products are accessible to citizens, and we rebuilt the process that Rawls uses for choosing his primary goods to test that cognitive enhancement through drugs could perfectly be introduced as such.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main thesis to be demonstrated in this work is that cognitive enhancement through the use of drugs can be included as a primary good within Rawls' thinking. To develop such notion, the text is structured in two parts. The first part intends to describe the theory of justice as equity in its elements directly related to primary goods. The first information to be verified is the unity of the notion of primary goods in all of Rawls' work. Some elements are modified, for example the distinction of natural and social primary goods. Natural primary goods are intelligence, health, imagination, vigor and chance (luck) and social primary goods are law and liberty, opportunity and power, income and wealth and the social fundaments of self-respect. The perception of some talents such as intelligence has also undergone changes, being altered from "higher intelligence" to "educated intelligence". Such fact highlights education as a primary good that permeates all of Rawls' work in different perspectives. Freedom and self-respect are social-primary goods that will also be deepened. The second part presents the definition of improvement and as to show that the distinction between enhancement and treatment is controversial. The part presents the definition of improvement and as the distinction between enhancement and treatment is controversial. Thus, we have deepened the problems related to practice improvement (enhancement) showing how the concepts of Rawls' primary goods as freedom and self-respect are not in opposition to the practice of improvement, particularly cognitive enhancement. We have shown, instead, that the ban of cognitive improvement could lead to denial of these primary goods. But how could we consider cognitive improvement as a primary social good? What we have done in this thesis is to show how cognitive enhancement is important to ensure that primary products are accessible to citizens, and we rebuilt the process that Rawls uses for choosing his primary goods to test that cognitive enhancement through drugs could perfectly be introduced as such.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this cross-sectional observational study was to quantify the pattern-shift visual evoked potentials (VEP) and the thickness as well as the volume of retinal layers using optical coherence tomography (OCT) across a cohort of Parkinson's disease (PD) patients and age-matched controls. Forty-three PD patients and 38 controls were enrolled. All participants underwent a detailed neurological and ophthalmologic evaluation. Idiopathic PD cases were included. Cases with glaucoma or increased intra-ocular pressure were excluded. Patients were assessed by VEP and high-resolution Fourier-domain OCT, which quantified the inner and outer thicknesses of the retinal layers. VEP latencies and the thicknesses of the retinal layers were the main outcome measures. The mean age, with standard deviation (SD), of the PD patients and controls were 63.1 (7.5) and 62.4 (7.2) years, respectively. The patients were predominantly in the initial Hoehn-Yahr (HY) disease stages (34.8% in stage 1 or 1.5, and 55.8 % in stage 2). The VEP latencies and the thicknesses as well as the volumes of the retinal inner and outer layers of the groups were similar. A negative correlation between the retinal thickness and the age was noted in both groups. The thickness of the retinal nerve fibre layer (RNFL) was 102.7 μm in PD patients vs. 104.2 μm in controls. The thicknesses of retinal layers, VEP, and RNFL of PD patients were similar to those of the controls. Despite the use of a representative cohort of PD patients and high-resolution OCT in this study, further studies are required to establish the validity of using OCT and VEP measurements as the anatomic and functional biomarkers for the evaluation of retinal and visual pathways in PD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the efficacy and safety of intravitreal bevacizumab (IVB) in eyes with neovascular glaucoma (NVG) undergoing Ahmed glaucoma valve (AGV) implantation. This was a multicentre, prospective, randomized clinical trial that enrolled 40 patients with uncontrolled neovascular glaucoma that had undergone panretinal photocoagulation and required glaucoma drainage device implantation. Patients were randomized to receive IVB (1.25 mg) or not during Ahmed valve implant surgery. Injections were administered intra-operatively, and 4 and 8 weeks after surgery. After a mean follow-up of 2.25 ± 0.67 years (range 1.5-3 years), both groups showed a significant decrease in IOP (p < 0.05). There was no difference in IOP between groups except at the 18-month interval, when IOP in IVB group was significantly lower (14.57 ± 1.72 mmHg vs. 18.37 ± 1.06 mmHg - p = 0.0002). There was no difference in survival success rates between groups. At 24 months, there was a trend to patients treated with IVB using less antiglaucoma medications than the control group (p = 0.0648). Complete regression of rubeosis iridis was significantly more frequent in the IVB group (80%) than in the control group (25%) (p = 0.0015). Intravitreal bevacizumab may lead to regression of new vessels both in the iris and in the anterior chamber angle in patients with neovascular glaucoma undergoing Ahmed glaucoma valve implantation. There is a trend to slightly lower IOPs and number of medications with IVB use during AGV implantation for neovascular glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last few years the sugar-cane mechanical harvested area has increased, especially in regions with appropriated slop. The use of this technology brings some inconveniences, such as, the increase in the percentage of extraneous matter, which causes the reduction of technological quality of the raw material, and losses in the field. Extraneous matter (trash) is composed of tops and leaves in major percentage, plus soil and roots, and eventually some metal parts. In the green cane harvest system the percentage of extraneous matter has a tendency to increase due to the great amount of vegetal matter to be processed. The increase in the blower fan speed to reduce the amount of extraneous matter can lead to an unacceptable economic level of raw material losses. The main objective of this work was, using a cane loss monitor, to evaluate and quantify the amount of visible losses of sugar cane through the primary extractor at two different fan speeds. Afterwards these losses were related to the harvester cleaning efficiency. The piezoelectric transducer shows a reasonable sensibility. The results show that the cleaning efficiency in the primary extractor (85% mean), the cane losses (between 5.68% and 2.15%) and fan speed are interrelated. The total losses and specially splinters (between 3.19% and 0.91%), showed a significant difference among the treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work the performance of a sugar cane chopped harvester was analysed when fed with two sugar cane mass flows, measuring the invisible losses, which are impossible to measure in the field, harvester sugar cane cleaning efficiency and air velocity on extractors exit. The trial was done under controlled conditions at Copersucar Technology Center in January 2000. The results showed that the flow of sugar cane through the harvester doesn't influence the magnitudes of total invisible losses and raw material cleaning efficiency. The mean air velocity on the primary extractors exit was 12.0 m s-1, and 9.2 m s-1 on the secondary extractor, with a coefficient of variation of 21%, indicating that the poor cleaning performance of the harvester could be related to air velocity difference inside the extractor. Analyzing the data collected in the trials, it was possible to conclude that invisible losses in sugar cane harvester were 10% and the cleaning efficiency was 87%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To analyze the efficacy and safety of intraope-rative mitomycin C (MMC) in combined procedures (extra-capsular cataract extraction + trabeculectomy). Methods: Twenty-four patients were randomized to either MMC (0.5 mg/ml) (n = 14) or saline solution (n = 10) for 3 minutes during the combined procedure. Results: Twelve months after surgery, mean IOP in the MMC group (13.2 ± 2.9 mmHg) was significantly lower than in the control group (16.3 ± 3.9 mmHg) (p = 0.02). The mean number of medications used during the 12-month follow-up in the control group (1.33 ± 0.5) was significantly higher than in the MMC-treated group (0.5 ± 0.5) (p = 0.005). Life table analysis showed a significantly higher probability of IOP control in the MMC group than in the control group (p < 0.01). Conclusions: Intraoperative MMC is safe and effective in pro-moting a better IOP control and reducing the need for postoperative antiglaucoma medications. We suggest intraope-rative MMC to be routinely employed in combined procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate changes in retinal nerve fiber layer thickness as measured by scanning laser polarimetry (SLP) after the use of medication to reduce intraocular pressure (IOP) in glaucomatous or ocular hypertensive patients. METHODS: The authors prospectively enrolled 37 eyes of 37 patients in whom IOP was reduced by more than 25% after the use of medication. The images were obtained before and 15 to 30 days after the introduction of medication. The SLP parameters measured before and after the use of medication were compared using paired Student's t Test. RESULTS: The mean IOP was significantly reduced from 26.57±4.23 mmHg to 16.54 ±2.92 mmHg after the use of medication (p<0.05). None of the 10 SLP analyzed parameters was significantly affected by the reduction of IOP with medication (p>0.05). CONCLUSION: The retinal nerve fiber layer thickness, as measured by SLP, is not affected by the reduction of IOP with medication in patients with glaucoma or ocular hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare clinical trials published in Brazilian journals of ophthalmology and in foreign journals of ophthalmology with respect to the number of citations and the quality of reporting [by applying the Consolidated Standards for Reporting Trials (CONSORT) statement writing standards]. METHODS: The sample of this systematic review comprised the two Brazilian journals of ophthalmology indexed at Science Citation Index Expanded and six of the foreign journals of ophthalmology with highest Impact Factor® according ISI. All clinical trials (CTs) published from January 2009 to December 2010 at the Brazilians journals and a 1:1 randomized sample of the foreign journals were included. The primary outcome was the number of citations through the end of 2011. Subgroup analysis included language. The secondary outcome included likelihood of citation (cited at least once versus no citation), and presence or absence of CONSORT statement indicators. RESULTS: The citation counts were statistically significantly higher (P<0.001) in the Foreign Group (10.50) compared with the Brazilian Group (0.45). The likelihood citation was statistically significantly higher (P<0.001) in the Foreign Group (20/20 - 100%) compared with the Brazilian Group (8/20 - 40%). The subgroup analysis of the language influence in Brazilian articles showed that the citation counts were statistically significantly higher in the papers published in English (P<0.04). Of 37 possible CONSORT items, the mean for the Foreign Group was 20.55 and for the Brazilian Group was 13.65 (P<0.003). CONCLUSION: The number of citations and the quality of reporting of clinical trials in Brazilian journals of ophthalmology still are low when compared with the foreign journals of ophthalmology with highest Impact Factor®.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the association between language and number of citations of ophthalmology articles published in Brazilian journals. METHODS: This study was a systematic review. Original articles were identified by review of documents published at the two Brazilian ophthalmology journals indexed at Science Citation Index Expanded - SCIE [Arquivos Brasileiros de Oftalmologia (ABO) and Revista Brasileira de Oftalmologia (RBO)]. All document types (articles and reviews) listed at SCIE in English (English Group) or in Portuguese (Portuguese Group) from January 1, 2008 to December 31, 2009 were included, except: editorial materials; corrections; letters; and biographical items. The primary outcome was the number of citations through the end of second year after publication date. Subgroup analysis included likelihood of citation (cited at least once versus no citation), journal, and year of publication. RESULTS: The search at the web of science revealed 382 articles [107 (28%) in the English Group and 275 (72%) in the Portuguese Group]. Of those, 297 (77.7%) were published at the ABO and 85 (23.3%) at the RBO. The citation counts were statistically significantly higher (P<0.001) in the English Group (1.51 - SD 1.98 - range 0 to 11) compared with the Portuguese Group (0.57 - SD 1.06 - range 0 to 7). The likelihood citation was statistically significant higher (P<0.001) in the English Group (70/107 - 65.4%) compared with the Portuguese Group (89/275 - 32.7%). There were more articles published in English at the ABO (98/297 - 32.9%) than at the RBO (9/85 - 10.6%) [P<0.001]. There were no significant difference (P=0.967) at the proportion of articles published in English at the years 2008 (48/172 - 27.9%) and 2009 (59/210 - 28.1%). CONCLUSION: The number of citations of articles published in Portuguese at Brazilian ophthalmology journals is lower than the published in English. The results of this study suggest that the editorial boards should strongly encourage the authors to adopt English as the main language in their future articles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: A intussuscepção ocorre quando um segmento proximal do intestino invagina para dentro do lúmen do segmento distal adjacente. Esta patologia é relativamente comum em crianças, sendo geralmente idiopática, diferentemente do que é evidenciado em adolescentes e adultos, os quais apresentam uma causa orgânica comprovada na maioria dos casos. O linfoma intestinal como etiologia desta patologia é extremamente raro. RELATO DE CASO: Um paciente de 16 anos, masculino, referindo dor abdominal em quadrante inferior direito há 36 horas associada a vômitos e fezes com sangue vivo compareceu em nosso serviço. O exame físico se apresentava dentro da normalidade exceto por uma massa palpável no quadrante inferior direito. A ultra-sonografia abdominal revelou intussuscepção ileocecal. A colonoscopia demonstrou uma massa protuberante proveniente do orifício da válvula ileocecal que foi reduzida, tendo o paciente um alívio completo dos sintomas. Três semanas após, o paciente retornou ao nosso hospital com recorrência dos sintomas. Uma laparotomia exploradora foi realizada evidenciando uma massa polipóide no íleo terminal com intussuscepção para dentro do ceco. Uma colectomia direita ampliada foi realizada. Após exame patológico da peça e estadiamento tumoral, um linfoma de Burkitt primário foi diagnosticado. A recuperação pós-operatória não apresentou intercorrências e o paciente foi encaminhado para quimioterapia adjuvante.