183 resultados para Geomechanics
Resumo:
In the present paper, the constitutive model is proposed for cemented soils, in which the cementation component and frictional component are treated separately and then added together to get overall response. The modified Cam clay is used to predict the frictional resistance and an elasto-plastic strain softening model is proposed for the cementation component. The rectangular isotropic yield curve proposed by Vatsala (1995) for the bond component has been modified in order to account for the anisotropy generally observed in the case of natural soft cemented soils. In this paper, the model proposed is used to predict the experimental results of extension tests on the soft cemented soils whereas compression test results are presented elsewhere. The model predictions compare quite satisfactorily with the observed response. A few input parameters are required which are well defined and easily determinable and the model uses associated flow rule.
Resumo:
A rigorous lower bound solution, with the usage of the finite elements limit analysis, has been obtained for finding the ultimate bearing capacity of two interfering strip footings placed on a sandy medium. Smooth as well as rough footingsoil interfaces are considered in the analysis. The failure load for an interfering footing becomes always greater than that for a single isolated footing. The effect of the interference on the failure load (i) for rough footings becomes greater than that for smooth footings, (ii) increases with an increase in phi, and (iii) becomes almost negligible beyond S/B>3. Compared with various theoretical and experimental results reported in literature, the present analysis generally provides the lowest magnitude of the collapse load. Copyright (c) 2011 John Wiley & Sons, Ltd.
Resumo:
The linearization of the Drucker-Prager yield criterion associated with an axisymmetric problem has been achieved by simulating a sphere with the truncated icosahedron with 32 faces and 60 vertices. On this basis, a numerical formulation has been proposed for solving an axisymmetric stability problem with the usage of the lower-bound limit analysis, finite elements, and linear optimization. To compare the results, the linearization of the Mohr-Coulomb yield criterion, by replacing the three cones with interior polyhedron, as proposed earlier by Pastor and Turgeman for an axisymmetric problem, has also been implemented. The two formulations have been applied for determining the collapse loads for a circular footing resting on a cohesive-friction material with nonzero unit weight. The computational results are found to be quite convincing. (C) 2013 American Society of Civil Engineers.
Resumo:
This paper describes the development of a numerical model for simulating the shaking table tests on wrap-faced reinforced soil retaining walls. Some of the physical model tests carried out on reinforced soil retaining walls subjected to dynamic excitation through uniaxial shaking tests are briefly discussed. Models of retaining walls are constructed in a perspex box with geotextile reinforcement using the wraparound technique with dry sand backfill and instrumented with displacement sensors, accelerometers, and soil pressure sensors. Results showed that the displacements decrease with the increase in number of reinforcement layers, whereas acceleration amplifications were not affected significantly. Numerical modeling of these shaking table tests is carried out using the Fast Lagrangian Analysis of Continua program. The numerical model is validated by comparing the results with experiments on physical models. Responses of wrap-faced walls with varying numbers of reinforcement layers are compared. Sensitivity analysis performed on the numerical models showed that the friction and dilation angle of backfill material and stiffness properties of the geotextile-soil interface are the most affecting parameters for the model response.
Resumo:
By using the axisymmetric quasi-lower bound finite-element limit analysis, the bearing capacity factors N-c(p) and N-gamma q(p) have been computed for axially loaded piles, with the shaft embedded in a fully cohesive soil medium and the tip placed over cohesive frictional soil strata. The results were obtained for various combinations of L/D, phi(l), and c(l)/c(u); the subscripts l and u refer to lower and upper soil strata, respectively. The factors N-c(p) and N-gamma q(p) increase continuously with increases in L/D and phi(l); the rate of increase of N-c(p) and N-gamma q(p) with L/D, however, decreases with an increase in L/D. For c(l)/c(u) > 100, the factor N-c(p) hardly depends on L/D.
Resumo:
Fastest curve-fitting procedures are proposed for vertical and radial consolidations for rapid loading methods. In vertical consolidation, the next load increment can be applied at 50-60% consolidation (or even earlier if the compression index is known). In radial consolidation, the next load increment can be applied at just 10-15% consolidation. The effects of secondary consolidation on the coefficient of consolidation and ultimate settlement are minimized in both cases. A quick procedure is proposed in vertical consolidation that determines how far is calculated from the true , where is coefficient of consolidation. In radial consolidation no such procedure is required because at 10-15% the consolidation effects of secondary consolidation are already less in most inorganic soils. The proposed rapid loading methods can be used when the settlement or time of load increment is not known. The characteristic features of vertical, radial, three-dimensional, and secondary consolidations are given in terms of the rate of settlement. A relationship is proposed between the coefficient of the vertical consolidation, load increment ratio, and compression index. (C) 2013 American Society of Civil Engineers.
Resumo:
A detailed study on the postliquefaction undrained shear behavior of sand-silt mixtures at constant void ratios is presented in this article. The influence of different parameters such as density, amplitude of cyclic shear stress, and drainage conditions on the postliquefaction undrained response of sand-silt mixtures has been investigated, in addition to the effect of fines content. The results showed that the limiting silt content plays a vital role in the strength of the soil under both cyclic and monotonic shear loading. Both the liquefaction resistance and postliquefaction shear strength of the soils are found to decrease with an increase in the fines content until the limiting silt content is reached. However, further increase in the silt content beyond the limiting silt content increases the liquefaction resistance as well as the postliquefaction shear strength of the soils. It is also observed that these variations on the liquefaction and postliquefaction resistance of soils are closely related to the variations in relative density. (C) 2013 American Society of Civil Engineers.
Resumo:
The horizontal pullout capacity of a group of two vertical strip plate anchors, placed along the same vertical plane, in a fully cohesive soil has been computed by using the lower bound finite element limit analysis. The effect of spacing between the plate anchors on the magnitude of total group failure load (P-uT) has been evaluated. An increase of soil cohesion with depth has also been incorporated in the analysis. For a weightless medium, the total pullout resistance of the group becomes maximum corresponding to a certain optimum spacing between the anchor plates which has been found to vary generally between 0.5B and B; where B is the width of the anchor plate. As compared to a single plate anchor, the increase in the pullout resistance for a group of two anchors becomes greater at a higher embedment ratio. The effect of soil unit weight has also been analyzed. It is noted that the interference effect on the pullout resistance increases further with an increase in the unit weight of soil mass.
Resumo:
Geotextiles and geogrids have been in use for several decades in variety of geo-structure applications including foundation of embankments, retaining walls, pavements. Geocells is one such variant in geosynthetic reinforcement of recent years, which provides a three dimensional confinement to the infill material. Although extensive research has been carried on geocell reinforced sand, clay and layered soil subgrades, limited research has been reported on the aggregates/ballast reinforced with geocells. This paper presents the behavior of a railway sleeper subjected to monotonic loading on geocell reinforced aggregates, of size ranging from 20 to 75 mm, overlying soft clay subgrades. Series of tests were conducted in a steel test tank of dimensions 700 mm x 300 mm x 700 mm. In addition to the laboratory model tests, numerical simulations were performed using a finite difference code to predict the behavior of geocell reinforced ballast. The results from numerical simulations were compared with the experimental data. The numerical and experimental results manifested the importance that the geocell reinforcement has a significant effect on the ballast behaviour. The results depicted that the stiffness of underlying soft clay subgrade has a significant influence on the behavior of the geocell-aggregate composite material in redistributing the loading system.
Resumo:
Triaxial tests are essential to estimate the shear strength properties of the soil or rock. Normally triaxial tests are carried out on samples of 38 mm diameter and 76 mm height. Granular materials, predominantly used in base/sub-base construction of pavements or in railways have size range of 60-75 mm. Determination of shear strength parameters of those materials can be made possible only through triaxial tests on large diameter samples. This paper describes a large diameter cyclic triaxial testing facility set up in the Geotechnical Engineering lab of Indian Institute of Science. This setup consists of 100 kN capacity dynamic loading frame, which facilitates testing of samples of up to 300 mm diameter and 600 mm height. The loading ram can be actuated up to a maximum frequency of 10 Hz, with maximum amplitude of 100 mm. The setup is capable of carrying out static as well as dynamic triaxial tests under isotropic, anisotropic conditions with a maximum confining pressure of 1 MPa. Working with this setup is a difficult task because of the size of the sample. In this paper, a detailed discussion on the various problems encountered during the initial testing using the equipment, the ideas and solutions adopted to solve them are presented. Pilot experiments on granular sub-base material of 53 mm down size are also presented.
Resumo:
The ultimate bearing capacity of strip foundations in the presence of inclined groundwater flow, considering both upward and downward flow directions, has been determined by using the lower bound finite-element limit analysis. A numerical solution has been generated for both smooth and rough footings placed on frictional soils. A correction factor (f gamma), which needs to be multiplied with the N gamma-term, has been computed to account for groundwater seepage. The variation of f gamma has been obtained as a function of the hydraulic gradient (i) for various inclinations of groundwater flow. For a given magnitude of i, there exists a certain critical inclination of the flow for which the value of f gamma is minimized. With an upward flow, for all flow inclinations, the magnitude of f gamma always reduces with an increase in the value of i. An example has also been provided to illustrate the application of the obtained results when designing foundations in the presence of groundwater seepage.
Resumo:
The ultimate bearing capacity of strip foundations subjected to horizontal groundwater flow has been computed by making use of the stress characteristics method which is well known for its capability in solving quite accurately different stability problems in geotechnical engineering. The numerical solution has been generated both for smooth and rough footings placed on frictional soils. A correction factor (fγ) associated with Nγ term, to account for the existence of ground water flow, has been introduced. The variation of fγ has been obtained as a function of hydraulic gradient (i) for different values of soil frictional angle. The magnitude of fγ reduces continuously with an increase in the value of i.