997 resultados para Galaxies: individual: M 51


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasing resistance to phosphine (PH 3) in insect pests, including lesser grain borer (Rhyzopertha dominica) has become a critical issue, and development of effective and sustainable strategies to manage resistance is crucial. In practice, the same grain store may be fumigated multiple times, but usually for the same exposure period and concentration. Simulating a single fumigation allows us to look more closely at the effects of this standard treatment.We used an individual-based, two-locus model to investigate three key questions about the use of phosphine fumigant in relation to the development of PH 3 resistance. First, which is more effective for insect control; long exposure time with a low concentration or short exposure period with a high concentration? Our results showed that extending exposure duration is a much more efficient control tactic than increasing the phosphine concentration. Second, how long should the fumigation period be extended to deal with higher frequencies of resistant insects in the grain? Our results indicated that if the original frequency of resistant insects is increased n times, then the fumigation needs to be extended, at most, n days to achieve the same level of insect control. The third question is how does the presence of varying numbers of insects inside grain storages impact the effectiveness of phosphine fumigation? We found that, for a given fumigation, as the initial population number was increased, the final survival of resistant insects increased proportionally. To control initial populations of insects that were n times larger, it was necessary to increase the fumigation time by about n days. Our results indicate that, in a 2-gene mediated resistance where dilution of resistance gene frequencies through immigration of susceptibles has greater effect, extending fumigation times to reduce survival of homozygous resistant insects will have a significant impact on delaying the development of resistance. © 2012 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Antiplatelet medication is known to decrease adverse effects in patients with atherothrombotic disease. However, despite ongoing antiplatelet medication considerable number of patients suffer from atherothrombotic events. The aims of the study were 1) to evaluate the individual variability in platelet functions and compare the usability of different methods in detecting it, 2) to assess variability in efficacy of antiplatelet medication with aspirin (acetylsalicylic acid) or the combination of aspirin and clopidogrel and 3) to investigate the main genetic and clinical variables as well as potential underlying mechanisms of variability in efficacy of antiplatelet medication. In comparisons of different platelet function tests in 19 healthy individuals PFA-100® correlated with traditional methods of measuring platelet function and was thus considered appropriate for testing individual variability in platelet activity. Efficacy of ongoing 100mg aspirin daily was studied in 101 patients with coronary artery disease (CAD). Aspirin response was measured with arachidonic acid (AA)-induced platelet aggregation, which reflects cyclo-oxygenase (COX)-1 dependent thromboxane (Tx) A2 formation, and PFA-100®, which evaluates platelet activation under high shear stress in the presence of collagen and epinephrine. Five percent of patients failed to show inhibition of AA-aggregation and 21% of patients had normal PFA-100® results despite aspirin and were thus considered non-responders to aspirin. Interestingly, the two methods of assessing aspirin efficacy, platelet aggregation and PFA-100®, detected different populations as being aspirin non-responders. It could be postulated that PFA-100® actually measures enhanced platelet function, which is not directly associated with TxA2 inhibition exerted by aspirin. Clopidogrel efficacy was assessed in 50 patients who received a 300mg loading dose of clopidogrel 2.5 h prior to percutaneous coronary intervention (PCI) and in 51 patients who were given a loading dose of 300mg combined with a five day treatment of 75mg clopidogrel daily mimicking ongoing treatment. Clopidogrel response was assessed with ADP-induced aggregations, due to its mechanism of action as an inhibitor of ADP-induced activation. When patients received only a loading dose of clopidogrel prior to PCI, 40% did not gain measurable inhibition of their ADP-induced platelet activity (inhibition of 10% or less). Prolongation of treatment so that all patients had reached a plateau of inhibition exerted by clopidogrel, decreased the incidence of non-responders to 20%. Polymorphisms of COX-1 and GP VI, as well as diabetes and female gender, were associated with decreased in vitro aspirin efficacy. Diabetes also impaired the in vitro efficacy of short-term clopidogrel. Decreased response to clopidogrel was associated with limited inhibition by ARMX, an antagonist of P2Y12-receptor, suggesting the reason for clopidogrel resistance to be receptor-dependent. Conclusions: Considerable numbers of CAD patients were non-responders either to aspirin, clopidogrel or both. In the future, platelet function tests may be helpful to individually select effective and safe antiplatelet medication for these patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent X-ray observations have revealed that early-type galaxies (which usually produce extended double radio sources) generally have hot gaseous haloes extending up to approx102kpc1,2. Moreover, much of the cosmic X-ray background radiation is probably due to a hotter, but extremely tenuous, intergalactic medium (IGM)3. We have presented4–7 an analytical model for the propagation of relativistic beams from galactic nuclei, in which the beams' crossing of the pressure-matched interface between the IGM and the gaseous halo, plays an important role. The hotspots at the ends of the beams fade quickly when their advance becomes subsonic with respect to the IGM. This model has successfully predicted (for typical double radio sources) the observed8 current mean linear-size (approx2Dsime350 kpc)4,5, the observed8–11 decrease in linear-size with cosmological redshift4–6 and the slope of the linear-size versus radio luminosity10,12–14 relation6. We have also been able to predict the redshift-dependence of observed numbers and radio luminosities of giant radio galaxies7,15. Here, we extend this model to include the propagation of somewhat weaker beams. We show that the observed flattening of the local radio luminosity function (LRLF)16–20 for radio luminosity Papproximately 1024 W Hz-1 at 1 GHz can be explained without invoking ad hoc a corresponding break in the beam power function Phi(Lb), because the heads of the beams with Lb < 1025 W Hz-1 are decelerated to sonic velocity within the halo itself, which leads to a rapid decay of radio luminosity and a reduced contribution of these intrinsically weaker sources to the observed LRLF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The assembly history of massive galaxies is one of the most important aspects of galaxy formation and evolution. Although we have a broad idea of what physical processes govern the early phases of galaxy evolution, there are still many open questions. In this thesis I demonstrate the crucial role that spectroscopy can play in a physical understanding of galaxy evolution. I present deep near-infrared spectroscopy for a sample of high-redshift galaxies, from which I derive important physical properties and their evolution with cosmic time. I take advantage of the recent arrival of efficient near-infrared detectors to target the rest-frame optical spectra of z > 1 galaxies, from which many physical quantities can be derived. After illustrating the applications of near-infrared deep spectroscopy with a study of star-forming galaxies, I focus on the evolution of massive quiescent systems.

Most of this thesis is based on two samples collected at the W. M. Keck Observatory that represent a significant step forward in the spectroscopic study of z > 1 quiescent galaxies. All previous spectroscopic samples at this redshift were either limited to a few objects, or much shallower in terms of depth. Our first sample is composed of 56 quiescent galaxies at 1 < z < 1.6 collected using the upgraded red arm of the Low Resolution Imaging Spectrometer (LRIS). The second consists of 24 deep spectra of 1.5 < z < 2.5 quiescent objects observed with the Multi-Object Spectrometer For Infra-Red Exploration (MOSFIRE). Together, these spectra span the critical epoch 1 < z < 2.5, where most of the red sequence is formed, and where the sizes of quiescent systems are observed to increase significantly.

We measure stellar velocity dispersions and dynamical masses for the largest number of z > 1 quiescent galaxies to date. By assuming that the velocity dispersion of a massive galaxy does not change throughout its lifetime, as suggested by theoretical studies, we match galaxies in the local universe with their high-redshift progenitors. This allows us to derive the physical growth in mass and size experienced by individual systems, which represents a substantial advance over photometric inferences based on the overall galaxy population. We find a significant physical growth among quiescent galaxies over 0 < z < 2.5 and, by comparing the slope of growth in the mass-size plane dlogRe/dlogM with the results of numerical simulations, we can constrain the physical process responsible for the evolution. Our results show that the slope of growth becomes steeper at higher redshifts, yet is broadly consistent with minor mergers being the main process by which individual objects evolve in mass and size.

By fitting stellar population models to the observed spectroscopy and photometry we derive reliable ages and other stellar population properties. We show that the addition of the spectroscopic data helps break the degeneracy between age and dust extinction, and yields significantly more robust results compared to fitting models to the photometry alone. We detect a clear relation between size and age, where larger galaxies are younger. Therefore, over time the average size of the quiescent population will increase because of the contribution of large galaxies recently arrived to the red sequence. This effect, called progenitor bias, is different from the physical size growth discussed above, but represents another contribution to the observed difference between the typical sizes of low- and high-redshift quiescent galaxies. By reconstructing the evolution of the red sequence starting at z ∼ 1.25 and using our stellar population histories to infer the past behavior to z ∼ 2, we demonstrate that progenitor bias accounts for only half of the observed growth of the population. The remaining size evolution must be due to physical growth of individual systems, in agreement with our dynamical study.

Finally, we use the stellar population properties to explore the earliest periods which led to the formation of massive quiescent galaxies. We find tentative evidence for two channels of star formation quenching, which suggests the existence of two independent physical mechanisms. We also detect a mass downsizing, where more massive galaxies form at higher redshift, and then evolve passively. By analyzing in depth the star formation history of the brightest object at z > 2 in our sample, we are able to put constraints on the quenching timescale and on the properties of its progenitor.

A consistent picture emerges from our analyses: massive galaxies form at very early epochs, are quenched on short timescales, and then evolve passively. The evolution is passive in the sense that no new stars are formed, but significant mass and size growth is achieved by accreting smaller, gas-poor systems. At the same time the population of quiescent galaxies grows in number due to the quenching of larger star-forming galaxies. This picture is in agreement with other observational studies, such as measurements of the merger rate and analyses of galaxy evolution at fixed number density.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: A peptide vaccine was produced containing B and T cell epitopes from the V3 and C4 Envelope domains of 4 subtype B HIV-1 isolates (MN, RF, CanO, & Ev91). The peptide mixture was formulated as an emulsion in incomplete Freund's adjuvant (IFA). METHODS: Low-risk, healthy adult subjects were enrolled in a randomized, placebo-controlled dose-escalation study, and selected using criteria specifying that 50% in each study group would be HLA-B7+. Immunizations were scheduled at 0, 1, and 6 months using a total peptide dose of 1 or 4 mg. Adaptive immune responses in16 vaccine recipients and two placebo recipients after the 2nd immunization were evaluated using neutralization assays of sera, as well as ELISpot and ICS assays of cryopreserved PBMCs to assess CD4 and CD8 T-cell responses. In addition, (51)Cr release assays were performed on fresh PBMCs following 14-day stimulation with individual vaccine peptide antigens. RESULTS: 24 subjects were enrolled; 18 completed 2 injections. The study was prematurely terminated because 4 vaccinees developed prolonged pain and sterile abscess formation at the injection site-2 after dose 1, and 2 after dose 2. Two other subjects experienced severe systemic reactions consisting of headache, chills, nausea, and myalgia. Both reactions occurred after the second 4 mg dose. The immunogenicity assessments showed that 6/8 vaccinees at each dose level had detectable MN-specific neutralizing (NT) activity, and 2/7 HLA-B7+ vaccinees had classical CD8 CTL activity detected. However, using both ELISpot and ICS, 8/16 vaccinees (5/7 HLA-B7+) and 0/2 controls had detectable vaccine-specific CD8 T-cell responses. Subjects with moderate or severe systemic or local reactions tended to have more frequent T cell responses and higher antibody responses than those with mild or no reactions. CONCLUSIONS: The severity of local responses related to the formulation of these four peptides in IFA is clinically unacceptable for continued development. Both HIV-specific antibody and T cell responses were induced and the magnitude of response correlated with the severity of local and systemic reactions. If potent adjuvants are necessary for subunit vaccines to induce broad and durable immune responses, careful, incremental clinical evaluation is warranted to minimize the risk of adverse events. TRIAL REGISTRATION: ClinicalTrials.gov NCT00000886.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the detailed spectral analysis of a sample of M33 B-type supergiant stars, aimed at the determination of their fundamental parameters and chemical composition. The analysis is based on a grid of non-LTE metal line-blanketed model atmospheres including the effects of stellar winds and spherical extension computed with the code FASTWIND. Surface abundance ratios of C, N, and O are used to discuss the chemical evolutionary status of each individual star. The comparison of observed stellar properties with theoretical predictions of massive star evolutionary models shows good agreement within the uncertainties of the analysis. The spatial distribution of the sample allows us to investigate the existence of radial abundance gradients in the disk of M33. The comparison of stellar and H II region O abundances ( based on direct determinations of the electron temperature of the nebulae) shows good agreement. Using a simple linear radial representation, the stellar oxygen abundances result in a gradient of -0.0145 +/- 0.005 dex arcmin(-1) (or -0.06 +/- 0.02 dex kpc(-1)) up to a distance equal to similar to 1.1 times the isophotal radius of the galaxy. A more complex representation cannot be completely discarded by our stellar sample. The stellar Mg and Si abundances follow the trend displayed by O abundances, although with shallower gradients. These differences in gradient slope cannot be explained at this point. The derived abundances of the three alpha-elements yield solar metallicity in the central regions of the disk of M33. A comparison with recent planetary nebula data from Magrini and coworkers indicates that the disk of M33 has not suffered from a significant O enrichment in the last 3 Gyr.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Distinct neural populations carry signals from short-wave (S) cones. We used individual differences to test whether two types of pathways, those that receive excitatory input (S+) and those that receive inhibitory input (S-), contribute independently to psychophysical performance. We also conducted a genome-wide association study (GWAS) to look for genetic correlates of the individual differences. Our psychophysical test was based on the Cambridge Color Test, but detection thresholds were measured separately for S-cone spatial increments and decrements. Our participants were 1060 healthy adults aged 16-40. Test-retest reliabilities for thresholds were good (ρ=0.64 for S-cone increments, 0.67 for decrements and 0.73 for the average of the two). "Regression scores," isolating variability unique to incremental or decremental sensitivity, were also reliable (ρ=0.53 for increments and ρ=0.51 for decrements). The correlation between incremental and decremental thresholds was ρ=0.65. No genetic markers reached genome-wide significance (p-7). We identified 18 "suggestive" loci (p-5). The significant test-retest reliabilities show stable individual differences in S-cone sensitivity in a normal adult population. Though a portion of the variance in sensitivity is shared between incremental and decremental sensitivity, over 26% of the variance is stable across individuals, but unique to increments or decrements, suggesting distinct neural substrates. Some of the variability in sensitivity is likely to be genetic. We note that four of the suggestive associations found in the GWAS are with genes that are involved in glucose metabolism or have been associated with diabetes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Pan-STARRS1 (PS1) survey has obtained imaging in five bands (grizyP1) over 10 Medium Deep Survey (MDS) fields covering a total of 70 square degrees. This paper describes the search for apparently hostless supernovae (SNe) within the first year of PS1 MDS data with an aim of discovering superluminous supernovae (SLSNe). A total of 249 hostless transients were discovered down to a limiting magnitude of MAB ∼ 23.5, of which 76 were classified as Type Ia supernovae (SNe Ia). There were 57 SNe with complete light curves that are likely core-collapse SNe (CCSNe) or type Ic SLSNe and 12 of these have had spectra taken. Of these 12 hostless, non-Type Ia SNe, 7 were SLSNe of type Ic at redshifts between 0.5 and 1.4. This illustrates that the discovery rate of type Ic SLSNe can be maximized by concentrating on hostless transients and removing normal SNe Ia. We present data for two possible SLSNe; PS1-10pm (z = 1.206) and PS1-10ahf (z = 1.1), and estimate the rate of type Ic SLSNe to be between 3+3−2×10−53+3−2×10−53+3−2×10−5 and 8+2−1×10−58+2−1×10−58+2−1×10−5 that of the CCSN rate within 0.3 ≤ z ≤ 1.4 by applying a Monte Carlo technique. The rate of slowly evolving, type Ic SLSNe (such as SN2007bi) is estimated as a factor of 10 lower than this range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the Pan-STARRS1 discovery and light curves, and follow-up MMT and Gemini spectroscopy of an ultraluminous supernova (ULSN; dubbed PS1-11bam) at a redshift of z = 1.566 with a peak brightness of M UV ≈ -22.3 mag. PS1-11bam is one of the highest redshift spectroscopically confirmed SNe known to date. The spectrum exhibits broad absorption features typical of previous ULSNe (e.g., C II, Si III), and strong and narrow Mg II and Fe II absorption lines from the interstellar medium (ISM) of the host galaxy, confirmed by an [O II]λ3727 emission line at the same redshift. The equivalent widths of the Fe II λ2600 and Mg II λ2803 lines are in the top quartile of the quasar intervening absorption system distribution, but are weaker than those of gamma-ray burst intrinsic absorbers (i.e., GRB host galaxies). We also detect the host galaxy in pre-explosion Pan-STARRS1 data and find that its UV spectral energy distribution is best fit with a young stellar population age of τ* ≈ 15-45 Myr and a stellar mass of M * ≈ (1.1-2.6) × 109 M ⊙ (for Z = 0.05-1 Z ⊙). The star formation rate inferred from the UV continuum and [O II]λ3727 emission line is ≈10 M ⊙ yr-1, higher than in previous ULSN hosts. PS1-11bam provides the first direct demonstration that ULSNe can serve as probes of the ISM in distant galaxies. The depth and red sensitivity of PS1 are uniquely suited to finding such events at cosmologically interesting redshifts (z ~ 1-2); the future combination of LSST and 30 m class telescopes promises to extend this technique to z ~ 4.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Evaluate current data sharing activities of UK publicly funded Clinical Trial Units (CTUs) and identify good practices and barriers.

STUDY DESIGN AND SETTING: Web-based survey of Directors of 45 UK Clinical Research Collaboration (UKCRC)-registered CTUs.

RESULTS: Twenty-three (51%) CTUs responded: Five (22%) of these had an established data sharing policy and eight (35%) specifically requested consent to use patient data beyond the scope of the original trial. Fifteen (65%) CTUs had received requests for data, and seven (30%) had made external requests for data in the previous 12 months. CTUs supported the need for increased data sharing activities although concerns were raised about patient identification, misuse of data, and financial burden. Custodianship of clinical trial data and requirements for a CTU to align its policy to their parent institutes were also raised. No CTUs supported the use of an open access model for data sharing.

CONCLUSION: There is support within the publicly funded UKCRC-registered CTUs for data sharing, but many perceived barriers remain. CTUs are currently using a variety of approaches and procedures for sharing data. This survey has informed further work, including development of guidance for publicly funded CTUs, to promote good practice and facilitate data sharing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We observed 51 Peg, the first detected planet-bearing star, in a 55 ks XMM-Newton pointing and in 5 ks pointings each with Chandra HRC-I and ACIS-S. The star has a very low count rate in the XMM observation, but is clearly visible in the Chandra images due to the detectors' different sensitivity at low X-ray energies. This allows a temperature estimate for 51 Peg's corona of T⪉ 1 MK; the detected ACIS-S photons can be plausibly explained by emission lines of a very cool plasma near 200 eV. The constantly low X-ray surface flux and the flat-activity profile seen in optical Ca II data suggest that 51 Peg is a Maunder minimum star; an activity enhancement due to a Hot Jupiter, as proposed by recent studies, seems to be absent. The star's X-ray fluxes in different instruments are consistent with the exception of the HRC Imager, which might have a larger effective area below 200 eV than given in the calibration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resumo - O avanço tecnológico e científico no campo da Medicina tem favorecido a aplicação das radiações ionizantes nas áreas da Medicina Nuclear, Radiologia, Radioterapia e noutras especialidades relacionadas com a medicina de intervenção, como a Cardiologia. As Organizações de Saúde, com profissionais com risco de exposição a radiações ionizantes, são responsáveis, legislativamente, por assegurar a sua vigilância. Certificando a observação controlada das doses de exposição, os profissionais são monitorizados com dosímetros individuais e submetidos a vigilância médica. As leituras de dosímetria individual destes profissionais, originam por vezes, nos próprios, desconfianças e incertezas quanto aos valores medidos. Objectivo: avaliar o grau de confiança dos profissionais de saúde, expostos a radiações ionizantes, no sistema de monitorização individual. Metodologia: estudo observacional do tipo analítico- transversal, por questionário. Amostra de 190 Técnicos de Diagnóstico e Terapêutica de Cardiopneumologia, Medicina Nuclear, Radiologia, Radioterapia, expostos a radiações ionizantes, que exercem a sua actividade profissional em hospitais do concelho de Lisboa. Resultados: 51,1% dos Técnicos de Diagnóstico e Terapêutica não confiam nas leituras dos dosímetros, não se determinou uma relação estatisticamente significativa entre essa confiança, o tipo de dosímetro e a empresa que realiza as leituras. A confiança é maior nos que exercem em Organizações de Saúde públicas. 40,2% das Organizações de Saúde apresentam plano de vigilância médica, constatando-se uma falta de conformidade entre os Técnicos de Diagnóstico e Terapêutica, nalguns hospitais, relativamente à existência desse plano no respectivo hospital. A margem de erro associado ao estudo é de 5,09%, com um nível de confiança de 95%. -----------Abstract - The technological and scientific advances in the field of medicine has encouraged the application of ionizing radiation with a considerable positive contribution in the areas of Nuclear Medicine, Radiology, Radiotherapy and other specialties related to medical intervention like Cardiology. The Health Organizations that arise the risk of occupational exposure to ionizing radiation and is their responsibility to ensure monitoring, according the law. To ensure the monitoring of controlled doses of exposure, the exposed works use an individual dosimeter and undergo medical supervision. The individual dosimetry readings of health-care professionals, is sometimes questionable for themselves, arising distrust and uncertainty about the values measured. Objective: evaluate the degree of confidence of health professionals, exposed to radiation, on the system of individual monitoring. Methods: Observational study of cross-type analysis by questionnaire. Sample of 190 of technologists of Cardiopneumology, Nuclear Medicine, Radiology, Radiotherapy, exposed to ionizing radiation, which work in hospitals on the region of Lisbon. Results: 51.1% of technologists does not rely on the readings of their dosimeters, and wasn’t determined a statistically significant relationship between this trust, the type of dosimeter and the company that makes the readings(s) of their(s) dosimeter(s). The confidence in the readings is higher in public Health Organizations. 40.2% of the Health Organizations have medical monitoring plan and there is a disagreement between technologists, in some hospitals, relatively to the existence of this plan in their hospital. It was estimated that the u

Relevância:

30.00% 30.00%

Publicador:

Resumo:

I t is generally accepted among scholars that individual learning and team learning contribute to the concept we refer to as organizational learning. However, a small number of quantitative and qualitative studies that have investigated their relationship reported contradicting results. This thesis investigated the relationship between individual learning, team learning, and organizational learning. A survey instrument was used to collect information on individual learning, team learning, and organizational learning. The study sample comprised of supervisors from the clinical laboratories in teaching hospitals and community hospitals in Ontario. The analyses utilized a linear regression to investigate the relationship between individual and team learning. The relationship between individual and organizational learning, and team and organizational learning were simultaneously investigated with canonical correlation and set correlation. T-test and multivariate analysis of variance were used to compare the differences in learning scores of respondents employed by laboratories in teaching and those employed by community hospitals. The study validated its tests results with 1,000 bootstrap replications. Results from this study suggest that there are moderate correlations between individual learning and team learning. The correlation individual learning and organizational learning and team learning and organizational learning appeared to be weak. The scores of the three learning levels show statistically significant differences between respondents from laboratories in teaching hospitals and respondents from community hospitals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Orosensory perception strongly influences liking and consumption of foods and beverages. This thesis examines the influence of biological sources of individual variation on the perception of prototypical orosensory stimuli, food liking, self-reported alcohol liking and consumption, and indices of health. Two orosensory indices were examined: propylthiouracil (PROP) responsiveness, a genetically-mediated index of individual variation associated with enhanced responsiveness to orosensory stimuli often expressed as PROP taster status (PTS); and thermal taster status (TTS), a recently reported index of orosensory responsiveness. Taster status in PTS and/or TTS confers greater responsiveness to most orosensory stimuli. Gender, age, ethnicity, and fungiform papillae (FP) density were not associated with orosensory responsiveness to tastants, an astringent, and a flavour. Unlike PROP responsiveness, FP density was not associated with TTS. Both PROP responsiveness and TTS were associated with increased responsiveness to orosensory stimuli, including temperature and astringency. For PROP, this association did not hold when stimuli were presented at cold or warm temperatures, which are ecologically valid since most foods and beverages are not consumed at ambient temperature. Thermal tasters (TTs), who perceive 'phantom' taste sensations with lingual thermal stimulation, were more responsive to stimuli at both temperatures than thermal non-tasters (TnTs). While PTS, TIS, and gender affected self-reported liking and consumption of some alcoholic beverages, gender associated with the greatest number of beverage types and consumption parameters, with males generally liking and consuming alcoholic beverages more than females. Age and gender were the best predictors of alcoholic beverageAiking and consumption. As expected, .. liking of bitter and fatty foods and cream was inversely related to PROP responsiveness. TTS did not associate with body mass index or waist circumference, and contrary to previous studies, neither did PROP responsiveness. Taken together, TnTs' greater liking of cooked fruits and vegetables and high alcohol, and astringent alcoholic beverages than TTs suggests differences between TTS groups may be driven by perceived temperature and texture. Neither an interaction between PTS and TTS nor a TTS effect on PROP responsiveness was observed, suggesting these two indices of individual variation exert their influences on orosensory perception independently.