933 resultados para GENETIC ANIMAL MODEL
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
PURPOSE: In previous papers, we described a new experimental model of congenital diaphragmatic hernia in rabbits, and we also reported noninvasive therapeutic strategies for prevention of the functional and structural immaturity of the lungs associated with this defect. In addition to lung hypoplasia, pulmonary hypertension, biochemical, and structural immaturity of the lungs, the hemodynamics of infants and animals with congenital diaphragmatic hernia are markedly altered. Hence, cardiac hypoplasia has been implicated as a possible cause of death in patients with congenital diaphragmatic hernia, and it is hypothesized to be a probable consequence of fetal mediastinal compression by the herniated viscera. Cardiac hypoplasia has also been reported in lamb and rat models of congenital diaphragmatic hernia. The purpose of the present experiment was to verify the occurrence of heart hypoplasia in our new model of surgically produced congenital diaphragmatic hernia in fetal rabbits. METHODS: Twelve pregnant New Zealand rabbits underwent surgery on gestational day 24 or 25 (normal full gestational time - 31 to 32 days) to create left-sided diaphragmatic hernias in 1 or 2 fetuses per each doe. On gestational day 30, all does again underwent surgery, and the delivered fetuses were weighed and divided into 2 groups: control (non-surgically treated fetuses) (n = 12) and congenital diaphragmatic hernia (n = 9). The hearts were collected, weighed, and submitted for histologic and histomorphometric studies. RESULTS: During necropsy, it was noted that in all congenital diaphragmatic hernia fetuses, the left lobe of the liver herniated throughout the surgically created defect and occupied the left side of the thorax, with the deviation of the heart to the right side, compressing the left lung; consequently, this lung was smaller than the right one. The body weights of the animals were not altered by congenital diaphragmatic hernia, but heart weights were decreased in comparison to control fetuses. The histomorphometric analysis demonstrated that congenital diaphragmatic hernia promoted a significant decrease in the ventricular wall thickness and an increase in the interventricular septum thickness. CONCLUSION: Heart hypoplasia occurs in a rabbit experimental model of congenital diaphragmatic hernia. This model may be utilized for investigations in therapeutic strategies that aim towards the prevention or the treatment of heart hypoplasia caused by congenital diaphragmatic hernia.
Resumo:
La retina juega un rol esencial en el funcionamiento del sistema circadiano de los vertebrados al ser la encargada de sensar las condiciones de iluminación ambiental que ajustan el reloj interno con el fotoperíodo exterior a través de un circuito no-visual. Este circuito es independiente de la vía de formación de imágenes e involucra a las células ganglionares retinianas (CGRs) que proyectan a varias estructuras no-visuales del cerebro; esta vía es la encargada de regular el reflejo pupilar, la sincronización de los ritmos diarios de actividad, el sueño y la supresión de melatonina pineal. La retina contiene además un reloj autónomo que genera ritmos diarios autosostenidos en distintas funciones bioquímicas y fisiológicas, que le confiere la capacidad de predecir el tiempo y anticiparse en su fisiología a los cambios lumínicos a lo largo del ciclo día-noche. Este laboratorio ha demostrado por 1ra vez que las CGRs de pollo poseen osciladores endógenos que generan variaciones diarias en la biosíntesis de fosfolípidos (Guido et al, J Neurochem. 2001; Garbarino et al., J Neurosci Res. 2004a) y de la hormona melatonina con niveles máximos durante el día (Garbarino et al., J Biol Chem 2004b). Aún más, cultivos primarios de CGRs responden a la luz a través de una cascada bioquímica de fototransducción similar a la de invertebrados y que involucra la activación de la enzima fosfolipasa C (PLC) (Contin et al., FASEB J 2006). Estos cultivos fueron obtenidos a estadios embrionarios muy tempranos en dónde solo las CGRs son postmitóticas y mayoritariamente maduras. A estos estadios, los cultivos expresan marcadores de especificación de células ganglionares (pax6, brn3), la proteina Gq y los fotopigmentos melanopsina y criptocromos con gran homología con marcadores descriptos para fotorreceptores rabdoméricos de invertebrados (Contin et al, 2006). Recientemente comenzamos a investigar la percepción de luz en pollos GUCY1*, un modelo de ceguera, en animales que carecen de células fotorreceptoras-conos y bastones-funcionales. Resultados preliminares indicarían que la retina interna, y potencialmente las CGRs de estos animales conservarían la capacidad de responder a la luz regulando el reflejo pupilar y sincronizando los ritmos diarios de alimentación. La convergencia de osciladores y fotopigmentos en la población de CGRs podría contribuir al control temporal de la fisiología del organismo y regulación de funciones no-visuales. Son objetivos de este proyecto: a) Investigar el rol de las CGRs en el sistema circadiano estudiando: i- su habilidad para sintetizar melatonina y, su regulación por luz y dopamina; ii- su capacidad fotorreceptora intrínseca, investigando la presencia de fotopigmentos y componentes de la cascada de fototransducción fundamentalmente la vía de los fosfoinosítidos y la activación de PLC, mediante ensayos moleculares, bioquímicos y farmacológicos; b) Extender estos estudios a cultivos primarios de CGRs inmunopurificadas midiendo la respuesta a la luz sobre la síntesis de melatonina, y los niveles de los mensajeros 2rios Ca2+ y AMP cíclico, la inducción de genes tempranos y la regulación de la actividad NAT, enzima clave en la síntesis de melatonina; y c) Investigar la percepción de luz en pollos GUCY1*(ciegos), sobre distintas funciones no-visuales tales como el reflejo pupilar, la sincronización de los ritmos diarios de alimentación, la síntesis de melatonina y la expresión génica en animales expuestos a estimulación lumínica de distintas intensidades y longitudes de onda. Estos estudios permitirán construir el espectro de acción de la respuesta a la luz en los pollos ciegos a fin de identificar el/los fotopigmentos intervinientes en este fenómeno. Este proyecto profundizará el conocimiento sobre la capacidad fotorreceptora-no visual de la retina interna y particularmente de las CGRs, de la naturaleza de la cascada bioquímica que opera en las mismas y de los mecanismos de regeneración del cromóforo utilizado.
Resumo:
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.
Resumo:
BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.
Resumo:
OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.
Resumo:
Toxoplasma gondii causes toxoplasmosis, a worldwide disease. Experimentation with pigs is necessary for the development of new therapeutic approaches to human diseases. BR-1 mini pigs were intramuscularly infected with T. gondii with tachyzoites (RH strain) or orally infected with cysts (ME-49 strain). Haematology and serum biochemistry were analysed and buffy coat cells were inoculated in mice to determine tachyzoite circulation. No alterations were observed in erythrocyte and platelet values; however, band neutrophils increased seven days after infection with ME-49. Serology of the mice inoculated with pig blood leucocytes revealed circulating ME-49 or RH strain tachyzoites in the pigs' peripheral blood at two and seven or nine days post-infection. The tachyzoites were also directly observed in blood smears from the infected pigs outside and inside leucocytes for longer periods. Alanine-aminotransferase was high at days 21 and 32 in the RH infected pigs. After 90 days, the pigs were euthanised and their tissue samples were processed and inoculated into mice. The mice serology revealed the presence of parasites in the hearts, ileums and mesenteric lymph nodes of the pigs. Additionally, cysts in the mice were only observed after pig heart tissue inoculation. The infected pigs presented similar human outcomes with relatively low pathogenicity and the BR-1 mini pig model infected with ME-49 is suitable to monitor experimental toxoplasmosis.
Resumo:
The most evident symptoms of schizophrenia are severe impairment of cognitive functions like attention, abstract reasoning and working memory. The latter has been defined as the ability to maintain and manipulate on-line a limited amount of information. Whereas several studies show that working memory processes are impaired in schizophrenia, the specificity of this deficit is still unclear. Results obtained with a new paradigm, involving visuospatial, dynamic and static working memory processing, suggest that schizophrenic patients rely on a specific compensatory strategy. An animal model of schizophrenia with a transient deficit in glutathione during the development reveals similar substitutive processing, masking the impairment in working memory functions in specific test conditions only. Taken together, these results show coherence between working memory deficits in schizophrenic patients and in animal models. More generally, it is possible to consider that the pathological state may be interpreted as a reduced homeostatic reserve. However, this may be balanced in specific situations by efficient allostatic strategies. Thus, the pathological condition would remain latent in several situations, due to such allostatic regulations. However, to maintain a performance based on highly specific strategies requires in turn specific conditions, limitating adaptative resources in humans and in animals. In summary, we suggest that the psychological and physical load to maintain this rigid allostatic state is very high in patients and animal subjects.
Resumo:
Purpose: Pathologic choroidal neovascularizations (CNV) are implicated in the wet form of age-related macular degeneration (ARMD). Abnormal vessel growth is also observed in disease when hypoxia and/or inflammation occur. Our goal is to establish a standard protocol of laser-induced CNV in mice that have different levels of pigmentation to identify the most reliable animal model.Methods: CNV was induced by 4 burns around the optic disk, using a green argon laser (100μm diameter spot size; 0,05 sec. duration) in C57/Bl6, DBA/1 and Balb/c to ascertain the efficacy of the method in function of retina pigmentation. Five different intensities were tested and Bruch's membrane disruption was identified by the appearance of a bubble at the site of photocoagulation. Fluorescein angiographies (FA) were undertaken 14 days post lesion and CNV area was quantified by immunohistochemistry on cryosections.Results: CNV retina area was related to spot intensity after laser injury. While 180mW and 200mW do not induce reliable CNV (respectively 27.85±0.35% and 29±1.67% of the retina surface), 260mW is required to induce 51,07±8.52% of CNV in C57/Bl6 mice. For the DBA/1 strain, less pigmented, 200mW was sufficient to induce 49.35±3.9% of CNV, indicating that lower intensity are required to induce CNV. Furthermore, an intensity of 180mW induced greater CNV (35.55±6.01%) than in C57/Bl6 mice. Nevertheless, laser did not induce reproducible 50% CNV in Balb/c albino mice for all intensities tested. Isolectin-B4 and GFAP stainings revealed neovessel formation and photoreceptor (PR) degeneration at the impact site. The presence of glia was observed throughout all the retinal layers and angiograms showed fluorescein leakage in pigmented mice.Conclusions: The establishment of a standard protocol to induce CNV and subsequent PR degeneration is of prime importance for the use of the laser-induced CNV model and will allow to evaluate the therapeutic potency of agents to prevent CNV and retinal degeneration.
Resumo:
BACKGROUND: A device to perform sutureless end-to-side coronary artery anastomosis has been developed by means of stent technology (GraftConnector). The present study assesses the long-term quality of the GraftConnector anastomosis in a sheep model. METHODS: In 8 adult sheep, 40-55 kg in weight, through left anterior thoracotomy, the right internal mammary artery (RIMA) was prepared and connected to the left anterior descending artery (LAD) by means of GraftConnector, on beating heart, without using any stabilizer. Ticlopidine 250 mg/day for anticoagulation for 4 weeks and Aspirin 100 mg/day for 6 months were given. The animals were sacrificed after 6 months and histological examination of anastomoses was carried out after slicing with the connector in situ for morphological analysis. RESULTS: All animals survived at 6 months. All anastomoses were patent and mean luminal width at histology was 1.8 +/- 0.2 mm; mean myotomia hyperplasia thickness was 0.21 +/- 0.1 mm. CONCLUSIONS: Long-term results demonstrate that OPCABGs performed with GraftConnector had 100% patency rate. The mean anastomotic luminal width corresponds to mean LAD's adult sheep diameter. We may speculate that myotomia hyperplasia occurred as a result of local device oversizing.
Resumo:
RAPPORT DE SYNTHÈSE : Pip5k3 : Pip5k3 is a kinase responsible for fleck corneal dystrophy when mutated. It is a well conserved gene that has only been characterized in human and mouse. Characterization of pip5k3 in zebrafish was necessary before using it as a model. The protein is 70 % similar to the human homologue. The full coding sequence encompasses 6303 by and presented four isoforms. They were differentially expressed during development. All the analyzed organs of the adult zebrafish expressed pip5k3. The adult eye expressed pip5k3 in the cornea, lens, ganglion cell layer (GCL), inner nuclear layer (INL) and outer limiting membrane (OLM). During development, pip5k3 was first uniformly expressed before to be restricted to the head region and to the somites. The expression of pip5k3 in the cornea of the larval eye could make possible the study of fleck corneal dystrophy on this animal. NkxS-3 : NKXS-3 is a transcription factor responsible for a new oculo-auricular syndrome in human when mutated. This recessive disorder is characterized by defects in ear lobule and multiple defects in eye, including microphthalmia and cataract. During development, the zebrafish expressed nkx5-3 in the lens, in the anterior retina and in otic vesicles. Knockdown experiments partially phenocopied the human disease. Microphthalmia and cataract were reproduced, but zebrafish showed also defects in the cartilage of the jaw associated with a microcephaly and fins abnormalities. The retinal cell differentiation was delayed, possibly linked with the delayed expression of at`h5 and crx also observed in morphants. Shh, a regulator of ath5, was normally expressed in morphant. Overexpression of nkx5-3 lead to an anophthalmia, suggesting a role at the early organogenesis of the eye. All the phenotypes observed in morphants and embryos overexpressing nkx5-3 suggest a potential involvement of the FGF and hedgehog signaling pathways.
Resumo:
AIM: The use of an animal model to study the aqueous dynamic and the histological findings after deep sclerectomy with (DSCI) and without collagen implant. METHODS: Deep sclerectomy was performed on rabbits' eyes. Eyes were randomly assigned to receive collagen implants. Measurements of intraocular pressure (IOP) and aqueous outflow facility using the constant pressure method through cannulation of the anterior chamber were performed. The system was filled with BSS and cationised ferritin. Histological assessment of the operative site was performed. Sections were stained with haematoxylin and eosin and with Prussian blue. Aqueous drainage vessels were identified by the reaction between ferritin and Prussian blue. All eyes were coded so that the investigator was blind to the type of surgery until the evaluation was completed. RESULTS: A significant decrease in IOP (p<0.05) was observed during the first 6 weeks after DSCI (mean IOP was 13.07 (2.95) mm Hg preoperatively and 9.08 (2.25) mm Hg at 6 weeks); DS without collagen implant revealed a significant decrease in IOP at weeks 4 and 8 after surgery (mean IOP 12.57 (3.52) mm Hg preoperatively, 9.45 (3.38) mm Hg at 4 weeks, and 9.22 (3.39) mm Hg at 8 weeks). Outflow facility was significantly increased throughout the 9 months of follow up in both DSCI and DS groups (p<0.05). The preoperative outflow facility (OF) was 0.15 (0.02) micro l/min/mm Hg. At 9 months, OF was 0.52 (0.28) microl/min/mm Hg and 0.46 (0.07) micro l/min/mm Hg for DSCI and DS respectively. Light microscopy studies showed the appearance of new aqueous drainage vessels in the sclera adjacent to the dissection site in DSCI and DS and the apparition of spindle cells lining the collagen implant in DSCI after 2 months. CONCLUSION: A significant IOP decrease was observed during the first weeks after DSCI and DS. DS with or without collagen implant provided a significant increase in outflow facility throughout the 9 months of follow up. This might be partly explained by new drainage vessels in the sclera surrounding the operated site. Microscopic studies revealed the appearance of spindle cells lining the collagen implant in DSCI after 2 months.