996 resultados para Functional validation
Resumo:
OBJECTIVE Translate the Patient-centered Assessment and Counseling for Exercise questionnaire, adapt it cross-culturally and identify the psychometric properties of the psychosocial scales for physical activity in young university students.METHODS The Patient-centered Assessment and Counseling for Exercise questionnaire is made up of 39 items divided into constructs based on the social cognitive theory and the transtheoretical model. The analyzed constructs were, as follows: behavior change strategy (15 items), decision-making process (10), self-efficacy (6), support from family (4), and support from friends (4). The validation procedures were conceptual, semantic, operational, and functional equivalences, in addition to the equivalence of the items and of measurements. The conceptual, of items and semantic equivalences were performed by a specialized committee. During measurement equivalence, the instrument was applied to 717 university students. Exploratory factor analysis was used to verify the loading of each item, explained variance and internal consistency of the constructs. Reproducibility was measured by means of intraclass correlation coefficient.RESULTS The two translations were equivalent and back-translation was similar to the original version, with few adaptations. The layout, presentation order of the constructs and items from the original version were kept in the same form as the original instrument. The sample size was adequate and was evaluated by the Kaiser-Meyer-Olkin test, with values between 0.72 and 0.91. The correlation matrix of the items presented r < 0.8 (p < 0.05). The factor loadings of the items from all the constructs were satisfactory (> 0.40), varying between 0.43 and 0.80, which explained between 45.4% and 59.0% of the variance. Internal consistency was satisfactory (α ≥ 0.70), with support from friends being 0.70 and 0.92 for self-efficacy. Most items (74.3%) presented values above 0.70 for the reproducibility test.CONCLUSIONS The validation process steps were considered satisfactory and adequate for applying to the population.
Resumo:
Prototype validation is a major concern in modern electronic product design and development. Simulation, structural test, functional and timing debug are all forming parts of the validation process, although very often addressed as dissociated tasks. In this paper we describe an integrated approach to board-level prototype validation, based on a set of mandatory/optional BST instructions and a built-in controller for debug and test, that addresses the late mentioned tasks as inherent parts of a whole process
Resumo:
AbstractBackground:30-40% of cardiac resynchronization therapy cases do not achieve favorable outcomes.Objective:This study aimed to develop predictive models for the combined endpoint of cardiac death and transplantation (Tx) at different stages of cardiac resynchronization therapy (CRT).Methods:Prospective observational study of 116 patients aged 64.8 ± 11.1 years, 68.1% of whom had functional class (FC) III and 31.9% had ambulatory class IV. Clinical, electrocardiographic and echocardiographic variables were assessed by using Cox regression and Kaplan-Meier curves.Results:The cardiac mortality/Tx rate was 16.3% during the follow-up period of 34.0 ± 17.9 months. Prior to implantation, right ventricular dysfunction (RVD), ejection fraction < 25% and use of high doses of diuretics (HDD) increased the risk of cardiac death and Tx by 3.9-, 4.8-, and 5.9-fold, respectively. In the first year after CRT, RVD, HDD and hospitalization due to congestive heart failure increased the risk of death at hazard ratios of 3.5, 5.3, and 12.5, respectively. In the second year after CRT, RVD and FC III/IV were significant risk factors of mortality in the multivariate Cox model. The accuracy rates of the models were 84.6% at preimplantation, 93% in the first year after CRT, and 90.5% in the second year after CRT. The models were validated by bootstrapping.Conclusion:We developed predictive models of cardiac death and Tx at different stages of CRT based on the analysis of simple and easily obtainable clinical and echocardiographic variables. The models showed good accuracy and adjustment, were validated internally, and are useful in the selection, monitoring and counseling of patients indicated for CRT.
Resumo:
BACKGROUND AND AIMS: Inflammatory bowel disease (IBD) frequently manifests during childhood and adolescence. For providing and understanding a comprehensive picture of a patients' health status, health-related quality of life (HRQoL) instruments are an essential complement to clinical symptoms and functional limitations. Currently, the IMPACT-III questionnaire is one of the most frequently used disease-specific HRQoL instrument among patients with IBD. However, there is a lack of studies examining the validation and reliability of this instrument. METHODS: 146 paediatric IBD patients from the multicenter Swiss IBD paediatric cohort study database were included in the study. Medical and laboratory data were extracted from the hospital records. HRQoL data were assessed by means of standardized questionnaires filled out by the patients in a face-to-face interview. RESULTS: The original six IMPACT-III domain scales could not be replicated in the current sample. A principal component analysis with the extraction of four factor scores revealed the most robust solution. The four factors indicated good internal reliability (Cronbach's alpha=.64-.86), good concurrent validity measured by correlations with the generic KIDSCREEN-27 scales and excellent discriminant validity for the dimension of physical functioning measured by HRQoL differences for active and inactive severity groups (p<.001, d=1.04). CONCLUSIONS: This study with Swiss children with IBD indicates good validity and reliability for the IMPACT-III questionnaire. However, our findings suggest a slightly different factor structure than originally proposed. The IMPACT-III questionnaire can be recommended for its use in clinical practice. The factor structure should be further examined in other samples.
Resumo:
OBJECTIVE: To determine the psychometric properties of an adapted version of the Falls Efficacy Scale (FES) in older rehabilitation patients. DESIGN: Cross-sectional survey. SETTING: Postacute rehabilitation facility in Switzerland. PARTICIPANTS: Seventy elderly persons aged 65 years and older receiving postacute, inpatient rehabilitation. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: FES questions asked about subject's confidence (range, 0 [none]-10 [full]) in performing 12 activities of daily living (ADLs) without falling. Construct validity was assessed using correlation with measures of physical (basic ADLs [BADLs]), cognitive (Mini-Mental State Examination [MMSE]), affective (15-item Geriatric Depression Scale [GDS]), and mobility (Performance Oriented Mobility Assessment [POMA]) performance. Predictive validity was assessed using the length of rehabilitation stay as the outcome. To determine test-retest reliability, FES administration was repeated in a random subsample (n=20) within 72 hours. RESULTS: FES scores ranged from 10 to 120 (mean, 88.7+/-26.5). Internal consistency was optimal (Cronbach alpha=.90), and item-to-total correlations were all significant, ranging from .56 (toilet use) to .82 (reaching into closets). Test-retest reliability was high (intraclass correlation coefficient, .97; 95% confidence interval, .95-.99; P<.001). Subjects reporting a fall in the previous year had lower FES scores than nonfallers (85.0+/-25.2 vs 94.4+/-27.9, P=.054). The FES correlated with POMA (Spearman rho=.40, P<.001), MMSE (rho=.37, P=.001), BADL (rho=.43, P<.001), and GDS (rho=-.53, P<.001) scores. These relationships remained significant in multivariable analysis for BADLs and GDS, confirming FES construct validity. There was a significant inverse relationship between FES score and the length of rehabilitation stay, independent of sociodemographic, functional, cognitive, and fall status. CONCLUSIONS: This adapted FES is reliable and valid in older patients undergoing postacute rehabilitation. The independent association between poor falls efficacy and increased length of stay has not been previously described and needs further investigations.
Resumo:
BACKGROUND: Anterior shoulder stabilization surgery with the arthroscopic Bankart procedure can have a high recurrence rate in certain patients. Identifying these patients to modify outcomes has become a focal point of research. PURPOSE: The Instability Shoulder Index Score (ISIS) was developed to predict the success of arthroscopic Bankart repair. Scores range from 0 to 10, with higher scores predicting a higher risk of recurrence after stabilization. The interobserver reliability of the score is not known. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: This is a prospective multicenter (North America and Europe) study of patients suffering from shoulder instability and waiting for stabilization surgery. Five pairs of independent evaluators were asked to score patient instability severity with the ISIS. Patients also completed functional scores (Western Ontario Shoulder Instability Index [WOSI], Disabilities of the Arm, Shoulder and Hand-short version [QuickDASH], and Walch-Duplay test). Data on age, sex, number of dislocations, and type of surgery were collected. The test-retest method and intraclass correlation coefficient (ICC: >0.75 = good, >0.85 = very good, and >0.9 = excellent) were used for analysis. RESULTS: A total of 114 patients with anterior shoulder instability were included, of whom 89 (78%) were men. The mean age was 28 years. The ISIS was very reliable, with an ICC of 0.933. The mean number of dislocations per patient was higher in patients who had an ISIS of ≥6 (25 vs 14; P = .05). Patients who underwent more complex arthroscopic procedures such as Hill-Sachs remplissage or open Latarjet had higher preoperative ISIS outcomes, with a mean score of 4.8 versus 3.4, respectively (P = .002). There was no correlation between the ISIS and the quality-of-life questionnaires, with Pearson correlations all >0.05 (WOSI = 0.39; QuickDASH = 0.97; Walch-Duplay = 0.08). CONCLUSION: Our results show that the ISIS is reliable when used in a multicenter study with anterior traumatic instability populations. There was no correlation between the ISIS and the quality-of-life questionnaires, but surgical decisions reflected its increased use.
Resumo:
CD6 has recently been identified and validated as risk gene for multiple sclerosis (MS), based on the association of a single nucleotide polymorphism (SNP), rs17824933, located in intron 1. CD6 is a cell surface scavenger receptor involved in T-cell activation and proliferation, as well as in thymocyte differentiation. In this study, we performed a haptag SNP screen of the CD6 gene locus using a total of thirteen tagging SNPs, of which three were non-synonymous SNPs, and replicated the recently reported GWAS SNP rs650258 in a Spanish-Basque collection of 814 controls and 823 cases. Validation of the six most strongly associated SNPs was performed in an independent collection of 2265 MS patients and 2600 healthy controls. We identified association of haplotypes composed of two non-synonymous SNPs [rs11230563 (R225W) and rs2074225 (A257V)] in the 2(nd) SRCR domain with susceptibility to MS (P max(T) permutation = 1×10(-4)). The effect of these haplotypes on CD6 surface expression and cytokine secretion was also tested. The analysis showed significantly different CD6 expression patterns in the distinct cell subsets, i.e. - CD4(+) naïve cells, P = 0.0001; CD8(+) naïve cells, P<0.0001; CD4(+) and CD8(+) central memory cells, P = 0.01 and 0.05, respectively; and natural killer T (NKT) cells, P = 0.02; with the protective haplotype (RA) showing higher expression of CD6. However, no significant changes were observed in natural killer (NK) cells, effector memory and terminally differentiated effector memory T cells. Our findings reveal that this new MS-associated CD6 risk haplotype significantly modifies expression of CD6 on CD4(+) and CD8(+) T cells.
Resumo:
AIM: The aim of this study was to interpret and validate a French version of the Oswestry disability index (ODI), using a cross-cultural validation method. The validity and reliability of the questionnaire was assessed in order to ensure the psychometric characteristics. METHOD: The cross-cultural validation was carried out according to Beaton's methodology. The study was conducted with 41 patients suffering from low back pain. The correlation between the ODI and the Roland-Morris disability questionnaire (RMDQ), the medical outcome survey short form-36 (MOS SF-36) and a pain visual analogical scale (VAS) was assessed. RESULTS: The validity of the Oswestry questionnaire was studied using the Cronbach Alpha coefficient calculation: 0.87 (n=36). The significant correlation between the ODI and RMDQ was 0.8 (P<0.001, n=41) and 0.71 (P<0.001, n=36) for the pain VAS. The correlation between the ODI and certain subscales (physical functioning 0.7 (P<0.001, n=41), physical role 0.49 et bodily pain 0.73 (P<0.001, n=41)) of the MOS SF-36 were equally significant. The reproducibility of the ODI was calculated using the Wilcoxon matched pairs test: there was no significant difference for eight out of ten sections or for the final score. CONCLUSION: This French translation of the ODI should be considered as valid and reliable. It should be used for any future clinical studies carried out using French language patients. Complimentary studies must be completed in order to assess its sensitivity to change in the event of any modifications in the patients functional capacity.
Resumo:
The turbot (Scophthalmus maximus) is a commercially valuable flatfish and one of the most promising aquaculture species in Europe. Two transcriptome 454-pyrosequencing runs were used in order to detect Single Nucleotide Polymorphisms (SNPs) in genesrelated to immune response and gonad differentiation. A total of 866 true SNPs were detected in 140 different contigs representing 262,093 bp as a whole. Only one true SNP was analyzed in each contig. One hundred and thirteen SNPs out of the 140 analyzed were feasible (genotyped), while Ш were polymorphic in a wild population. Transition/transversion ratio (1.354) was similar to that observed in other fish studies. Unbiased gene diversity (He) estimates ranged from 0.060 to 0.510 (mean = 0.351), minimum allele frequency (MAF) from 0.030 to 0.500 (mean = 0.259) and all loci were in Hardy-Weinberg equilibrium after Bonferroni correction. A large number of SNPs (49) were located in the coding region, 33 representing synonymous and 16 non-synonymous changes. Most SNP-containing genes were related to immune response and gonad differentiation processes, and could be candidates for functional changes leading to phenotypic changes. These markers will be useful for population screening to look for adaptive variation in wild and domestic turbot
Resumo:
The prognosis of community-acquired pneumonia ranges from rapid resolution of symptoms and full recovery of functional status to the development of severe medical complications and death. The pneumonia severity index is a rigorously studied prediction rule for prognosis that objectively stratifies patients into quintiles of risk for short-term mortality on the basis of 20 demographic and clinical variables routinely available at presentation. The pneumonia severity index was derived and validated with data on >50,000 patients with community-acquired pneumonia by use of well-accepted methodological standards and is the only pneumonia decision aid that has been empirically shown to safely increase the proportion of patients given treatment in the outpatient setting. Because of its prognostic accuracy, methodological rigor, and effectiveness and safety as a decision aid, the pneumonia severity index has become the reference standard for risk stratification of community-acquired pneumonia
Resumo:
BACKGROUND AND PURPOSE: The DRAGON score predicts functional outcome in the hyperacute phase of intravenous thrombolysis treatment of ischemic stroke patients. We aimed to validate the score in a large multicenter cohort in anterior and posterior circulation. METHODS: Prospectively collected data of consecutive ischemic stroke patients who received intravenous thrombolysis in 12 stroke centers were merged (n=5471). We excluded patients lacking data necessary to calculate the score and patients with missing 3-month modified Rankin scale scores. The final cohort comprised 4519 eligible patients. We assessed the performance of the DRAGON score with area under the receiver operating characteristic curve in the whole cohort for both good (modified Rankin scale score, 0-2) and miserable (modified Rankin scale score, 5-6) outcomes. RESULTS: Area under the receiver operating characteristic curve was 0.84 (0.82-0.85) for miserable outcome and 0.82 (0.80-0.83) for good outcome. Proportions of patients with good outcome were 96%, 93%, 78%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 2%, 4%, 89%, and 97% for 0 to 1, 2, 3, 8, and 9 to 10 points, respectively. When tested separately for anterior and posterior circulation, there was no difference in performance (P=0.55); areas under the receiver operating characteristic curve were 0.84 (0.83-0.86) and 0.82 (0.78-0.87), respectively. No sex-related difference in performance was observed (P=0.25). CONCLUSIONS: The DRAGON score showed very good performance in the large merged cohort in both anterior and posterior circulation strokes. The DRAGON score provides rapid estimation of patient prognosis and supports clinical decision-making in the hyperacute phase of stroke care (eg, when invasive add-on strategies are considered).
Resumo:
Introduction: Clinical examination and electroencephalography study (EEG) have been recommended to predict functional recovery in comatose survivors of cardiac arrest (CA), however their prognostic value in patients treated with induced hypothermia (IH) has not been evaluated. Hypothesis: We aimed to validate the prognostic ability of clinical examination and EEG in predicting outcome of patients with coma after CA treated with IH and sought to derive a score with high predictive value for poor functional outcome in this setting. Methods: We prospectively studied 100 consecutive comatose survivors of CA treated with IH. Repeated neurological examination and EEG were performed early after passive rewarming and off sedation. Mortality was assessed at hospital discharge, and functional outcome at 3 to 6 months with Cerebral Performance Categories (CPC), and was dichotomized as good (CPC 1-2) vs. poor (CPC 3-5). Independent predictors of outcome were identified by multivariable logistic regression and used to assess the prognostic value of a Reproducible Electro-clinical Prognosticators of Outcome Score (REPOS). Results: Patients (20/100) with good outcome had all a reactive EEG background. Incomplete recovery of brainstem reflexes, myoclonus, time to return of spontaneous circulation (ROSC) > 25 min, and unreactive EEG background were all independent predictors of death and severe disability, and were added to construct the REPOS. Using a cut-off of 0 or 1 variables for good vs. 2 to 4 for poor outcome, the REPOS had a positive predictive value of 1.00 (95% CI: 0.92-1.00), a negative predictive value of 0.43 (95% CI: 0.29-0.58) and an accuracy of 0.81 for poor functional recovery at 3 to 6 months. Conclusions: In comatose survivors of CA treated with IH, a prognostic score, including clinical and EEG examination, was highly predictive of death and poor functional outcome at 3 to 6 months. Lack of EEG background reactivity strongly predicted poor neurological recovery after CA. Our findings show that clinical and electrophysiological studies are effective in predicting long-term outcome of comatose survivors after CA and IH, and suggest that EEG improves early prognostic assessment in the setting of therapeutic cooling.
Resumo:
Introduction Functional subjective evaluation through questionnaire is fundamental, but not often realized in patients with back complaints, lacking validated tools. The Spinal Function Sort (SFS) was only validated in English. We aimed to translate, adapt and validate the French (SFS-F) and German (SFS-G) versions of the SFS. Methods Three hundred and forty-four patients, experiencing various back complaints, were recruited in a French (n = 87) and a German-speaking (n = 257) center. Construct validity was estimated via correlations with SF-36 physical and mental scales, pain intensity and hospital anxiety and depression scales (HADS). Scale homogeneities were assessed by Cronbach's α. Test-retest reliability was assessed on 65 additional patients using intraclass correlation (IC). Results For the French and German translations, respectively, α were 0.98 and 0.98; IC 0.98 (95% CI: [0.97; 1.00]) and 0.94 (0.90; 0.98). Correlations with physical functioning were 0.63 (0.48; 0.74) and 0.67 (0.59; 0.73); with physical summary 0.60 (0.44; 0.72) and 0.52 (0.43; 0.61); with pain -0.33 (-0.51; -0.13) and -0.51 (-0.60; -0.42); with mental health -0.08 (-0.29; 0.14) and 0.25 (0.13; 0.36); with mental summary 0.01 (-0.21; 0.23) and 0.28 (0.16; 0.39); with depression -0.26 (-0.45; -0.05) and -0.42 (-0.52; -0.32); with anxiety -0.17 (-0.37; -0.04) and -0.45 (-0.54; -0.35). Conclusions Reliability was excellent for both languages. Convergent validity was good with SF-36 physical scales, moderate with VAS pain. Divergent validity was low with SF-36 mental scales in both translated versions and with HADS for the SFS-F (moderate in SFS-G). Both versions seem to be valid and reliable for evaluating perceived functional capacity in patients with back complaints.
Resumo:
OBJECTIVE: To develop and validate a simple, integer-based score to predict functional outcome in acute ischemic stroke (AIS) using variables readily available after emergency room admission. METHODS: Logistic regression was performed in the derivation cohort of previously independent patients with AIS (Acute Stroke Registry and Analysis of Lausanne [ASTRAL]) to identify predictors of unfavorable outcome (3-month modified Rankin Scale score >2). An integer-based point-scoring system for each covariate of the fitted multivariate model was generated by their β-coefficients; the overall score was calculated as the sum of the weighted scores. The model was validated internally using a 2-fold cross-validation technique and externally in 2 independent cohorts (Athens and Vienna Stroke Registries). RESULTS: Age (A), severity of stroke (S) measured by admission NIH Stroke Scale score, stroke onset to admission time (T), range of visual fields (R), acute glucose (A), and level of consciousness (L) were identified as independent predictors of unfavorable outcome in 1,645 patients in ASTRAL. Their β-coefficients were multiplied by 4 and rounded to the closest integer to generate the score. The area under the receiver operating characteristic curve (AUC) of the score in the ASTRAL cohort was 0.850. The score was well calibrated in the derivation (p = 0.43) and validation cohorts (0.22 [Athens, n = 1,659] and 0.49 [Vienna, n = 653]). AUCs were 0.937 (Athens), 0.771 (Vienna), and 0.902 (when pooled). An ASTRAL score of 31 indicates a 50% likelihood of unfavorable outcome. CONCLUSIONS: The ASTRAL score is a simple integer-based score to predict functional outcome using 6 readily available items at hospital admission. It performed well in double external validation and may be a useful tool for clinical practice and stroke research.
Resumo:
Aim: Functional subjective evaluation through questionnaire is fundamental, but not often realized in patients with back complaints, notably because of lack of validated tools, in accordance with recognized psychometric criteria. The Spinal Function Sort (SFS), developed according to actual standards, was only validated in English. The aim of this study is to translate, adapt and validate the French and German version of the SFS.Method and material: The translation and cross-cultural adaptation were performed following the methodology proposed by the American Association of Orthopedist Surgeon. A total of 344 patients, presenting varied back complaints (especially degenerative and traumatic), took part in this study in a tertiary French- (n=87; mean age 44y; 17 women) and German-speaking (n=257; mean age 41y; 53 women) center. Test-retest reliability was quantified using the intraclass correlation coefficient (ICC) and construct validity was assessed by estimating the Pearson's correlation with the SF-36 physical and mental scales, the Visual Analogue Scale for Pain Intensity (VAS), and subscales of the Hospital Anxiety and Depression Scale (HADS).Results: Respectively for the French and German version, ICC were 0.98 and 0.94. Correlations 0.63 and 0.67 with the SF-36 Physical Functioning subscale; 0.60 and 0.52 with the SF-36 Physical Summary Scale ; -0.33 and -0.51 with the VAS ; -0.08 and 0.25 with the SF-36 Mental Health scale; 0.01 and 0.28 with the SF-36 Mental Summary Scale; -0.26 and -0.42 with the HADS depression; -0.17 and -0.45 with the HADS anxiety.Discussion: For both the French and German version of the SFS, the reliability was excellent. Convergent construct validity with SF-36 physical scales is good, moderated with the VAS. We find out a low correlation with SF-36 mental scales (divergent construct validity). We find out a low correlation with HADS subscales in the French version, and a moderate one in the German version. Selection bias, chronicity of the complaints, as well as cultural differences could explain these results. In conclusion, both the French and German version of the SFS are valid and reliable for evaluation of perceived functional capacity for patients with back complaints.