979 resultados para Frequency response function


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Continuing development of new materials makes systems lighter and stronger permitting more complex systems to provide more functionality and flexibility that demands a more effective evaluation of their structural health. Smart material technology has become an area of increasing interest in this field. The combination of smart materials and artificial neural networks can be used as an excellent tool for pattern recognition, turning their application adequate for monitoring and fault classification of equipment and structures. In order to identify the fault, the neural network must be trained using a set of solutions to its corresponding forward Variational problem. After the training process, the net can successfully solve the inverse variational problem in the context of monitoring and fault detection because of their pattern recognition and interpolation capabilities. The use of structural frequency response function is a fundamental portion of structural dynamic analysis, and it can be extracted from measured electric impedance through the electromechanical interaction of a piezoceramic and a structure. In this paper we use the FRF obtained by a mathematical model (FEM) in order to generate the training data for the neural networks, and the identification of damage can be done by measuring electric impedance, since suitable data normalization correlates FRF and electrical impedance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new approach for damage detection in Structural Health Monitoring (SHM) systems, which is based on the Electromechanical Impedance (EMI) principle and Autoregressive (AR) models. Typical applications of EMI in SHM are based on computing the Frequency Response Function (FRF). In this work the procedure is based on the EMI principle but the results are determined through the coefficients of AR models, which are computed from the time response of PZT transducers bonded to the monitored structure, and acting as actuator and sensors at the same time. The procedure is based on exciting the PZT transducers using a wide band chirp signal and getting its time response. The AR models are obtained in both healthy and damaged conditions and used to compute statistics indexes. Practical tests were carried out in an aluminum plate and the results have demonstrated the effectiveness of the proposed method. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a novel time domain approach for Structural Health Monitoring (SHM) systems based on Electromechanical Impedance (EMI) principle and Principal Component Coefficients (PCC), also known as loadings. Differently of typical applications of EMI applied to SHM, which are based on computing the Frequency Response Function (FRF), in this work the procedure is based on the EMI principle but all analysis is conducted directly in time-domain. For this, the PCC are computed from the time response of PZT (Lead Zirconate Titanate) transducers bonded to the monitored structure, which act as actuator and sensor at the same time. The procedure is carried out exciting the PZT transducers using a wide band chirp signal and getting their time responses. The PCC are obtained in both healthy and damaged conditions and used to compute statistics indexes. Tests were carried out on an aircraft aluminum plate and the results have demonstrated the effectiveness of the proposed method making it an excellent approach for SHM applications. Finally, the results using EMI signals in both frequency and time responses are obtained and compared. © The Society for Experimental Mechanics 2014.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A seletividade espacial para cor tem sido investigada usando métodos eletrofisiológicos invasivos e não invasivos, e métodos psicofísicos. Em eletrofisiologia cortical visual não invasiva este tópico foi investigado usando métodos convencionais de estimulação periódica e extração de respostas por promediação simples. Novos métodos de estimulação (apresentação pseudo-aleatória) e extração de respostas corticais não invasivas (correlação cruzada) foram desenvolvidos e ainda não foram usados para investigar a seletividade espacial de cor de respostas corticais. Este trabalho objetivou introduzir esse novo método de eletrofisiologia pseudoaleatória para estudar a seletividade espacial de cor. Foram avaliados 14 tricromatas e 16 discromatópsicos com acuidade visual normal ou corrigida. Os voluntários foram avaliados pelo anomaloscópio HMC e teste de figuras de Ishihara para caracterizar a visão de cores quanto à presença de tricromacia. Foram usadas redes senoidais, 8º de ângulo visual, vermelho-verde para 8 frequências espaciais entre 0,2 a 10 cpg. O estímulo foi temporalmente modulado por uma sequência-m binária em um modo de apresentação de padrão reverso. O sistema VERIS foi usado para extrair o primeiro e o segundo slice do kernel de segunda ordem (K2.1 e K2.2, respectivamente). Após a modelagem da resposta às frequências espaciais com função de diferença de gaussianas, extraiu-se a frequência espacial ótima e banda de frequências com amplitudes acima de ¾ da amplitude máxima da função para servirem como indicadores da seletividade espacial da função. Também foi estimada a acuidade visual cromática pelo ajuste de uma função linear aos dados de amplitude a partir da frequência espacial do pico de amplitude até a mais alta frequência espacial testada. Em tricromatas, foi encontrada respostas cromáticas no K2.1 e no K2.2 que apresentaram seletividade espacial diferentes. Os componentes negativos do K2.1 e do K2.2 apresentaram sintonia passa-banda e o componente positivo do K2.1 apresentou sintonia passa-baixa. A acuidade visual estimada de todos os componentes estudados foi próxima àquelas encontradas por Mullen (1985) e Kelly (1983). Diferentes componentes celulares podem estar contribuindo para a geração do VECP pseudoaleatório. Este novo método se candidata a ser uma importante ferramenta para a avaliação não invasiva da visão de cores em humanos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The article discusses a proposal of displacement measurement using a unique digital camera aiming at to exploit its feasibility for Modal Analysis applications. The proposal discusses a non-contact measuring approach able to measure multiple points simultaneously by using a unique digital camera. A modal analysis of a reduced scale lab building structure based only at the responses of the structure measured with the camera is presented. It focuses at the feasibility of using a simple ordinary camera for performing the output only modal analysis of structures and its advantage. The modal parameters of the structure are estimated from the camera data and also by using ordinary experimental modal analysis based on the Frequency Response Function (FRF) obtained by using the usual sensors like accelerometer and force cell. The comparison of the both analysis showed that the technique is promising noncontact measuring tool relatively simple and effective to be used in structural modal analysis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a program for simulations of vehicle-track and vehicle-trackstructure dynamic interaction . The method used is computationally efficient in the sense that a reduced number of coordinates is sufficient and doesn’t require high efficiency computers. The method proposes a modal substructuring approach of the system by modelling rails , sleepers and underlying structure with modal coordinates, the vehicle with physical lumped elements coordinates and by introducing interconnection elements between these structures (wheel-rail contact, railpads and ballast) by means of their interaction forces. The Frequency response function (FRF) is also calculated for both cases of track over a structure (a bridge, a viaduct ...) and for the simple vehicle-track program; for each case the vehicle effect on the FRF is then analyzed through the comparison of the FRFs obtained introducing or not a simplified vehicle on the system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis presents a methodology for measuring thermal properties in situ, with a special focus on obtaining properties of layered stack-ups commonly used in armored vehicle components. The technique involves attaching a thermal source to the surface of a component, measuring the heat flux transferred between the source and the component, and measuring the surface temperature response. The material properties of the component can subsequently be determined from measurement of the transient heat flux and temperature response at the surface alone. Experiments involving multilayered specimens show that the surface temperature response to a sinusoidal heat flux forcing function is also sinusoidal. A frequency domain analysis shows that sinusoidal thermal excitation produces a gain and phase shift behavior typical of linear systems. Additionally, this analysis shows that the material properties of sub-surface layers affect the frequency response function at the surface of a particular stack-up. The methodology involves coupling a thermal simulation tool with an optimization algorithm to determine the material properties from temperature and heat flux measurement data. Use of a sinusoidal forcing function not only provides a mechanism to perform the frequency domain analysis described above, but sinusoids also have the practical benefit of reducing the need for instrumentation of the backside of the component. Heat losses can be minimized by alternately injecting and extracting heat on the front surface, as long as sufficiently high frequencies are used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El objetivo de esta tesis es investigar las resonancias acústicas de una cavidad abierta tridimensional, de paredes rectas o inclinadas, mediante un método rápido y eficiente en el dominio del tiempo. Este método modela la respuesta temporal en cualquier punto como la convolución de la forma de onda de la fuente con la respuesta impulsiva de la cavidad, la cual se obtiene como una secuencia de impulsos retardados y atenuados procedentes de la fuente real, el primero, y de las fuentes imágenes especulares, los siguientes (Modelo Fuente Imagen, ISM). Además de las componentes directa y reflejadas en las paredes, la respuesta impulsiva también incluye las contribuciones difractadas en los bordes, obtenidas mediante la generación de las componentes difractadas de cada fuente imagen. Las frecuencias de resonancia acústica de la cavidad abierta son extraídas de los picos de la Función de Respuesta en Frecuencia (FRF), obtenida como la transformada de Fourier de la respuesta temporal correspondiente entre una fuente puntual y un punto cualquiera de la cavidad. Las frecuencias de resonancia acústicas estimadas mediante este Método de Fuentes Imagen + difracción en bordes son validadas por comparación con las que proporciona un Modelo de Elementos Finitos (FEM) y con las medidas experimentalmente, con diferencias menores que el 1.6 % y el 2.7 %, respectivamente. A modo de comparación, las frecuencias de resonancia estimadas para la misma cavidad por el método ISM, cuando no se incluye la difracción en los bordes, difieren en un 5.7 % de las obtenidas experimentalmente. ABSTRACT The goal of this thesis is to investigate the acoustic resonances of a three-dimensional open cavity, with parallel and non-parallel walls, by a fast and efficient method in the time domain. This method models the time response in any point as the convolution of the source waveform with the impulse response of the cavity, which, in turn, is obtained as a sequence of attenuated and delayed impulses coming, the first from the real, and the subsequent from the mirror imaged sources (Image Source Model). Besides direct and wall-reflected components, the impulse response includes also edge-diffracted contributions by generating first order diffraction components for each image source. The acoustic resonance frequencies of the open cavity are extracted from the peaks of the Frequency Response Function (FRF), obtained as the Fourier transform of the corresponding time response between a point source and any point in the cavity. The acoustic resonance frequencies estimated by the Image Source Model + edge diffraction are validated by comparison with those provided by a Finite Element Model (FEM) and the ones measured experimentally, differing less than 1.6 % and 2.7 %, respectively. As a comparison, resonance frequencies estimated with the pure Image Source Model differ by 5.7 % from the measured ones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El control del estado en el que se encuentran las estructuras ha experimentado un gran auge desde hace varias décadas, debido a que los costes de rehabilitación de estructuras tales como los oleoductos, los puentes, los edificios y otras más son muy elevados. En las últimas dos décadas, se han desarrollado una gran cantidad de métodos que permiten identificar el estado real de una estructura, basándose en modelos físicos y datos de ensayos. El ensayo modal es el más común; mediante el análisis modal experimental de una estructura se pueden determinar parámetros como la frecuencia, los modos de vibración y la amortiguación y también la función de respuesta en frecuencia de la estructura. Mediante estos parámetros se pueden implementar diferentes indicadores de daño. Sin embargo, para estructuras complejas y grandes, la implementación de metodologías basadas en la función de respuesta en frecuencia requeriría realizar hipótesis sobre la fuerza utilizada para excitar la estructura. Dado que el análisis modal operacional utiliza solamente las señales de respuesta del sistema para extraer los parámetros dinámicos estructurales y, por tanto, para evaluar el estado de una estructura, el uso de la transmisibilidad sería posible. En este sentido, dentro del análisis modal operacional, la transmisibilidad ha concentrado mucha atención en el mundo científico en la última década. Aunque se han publicado muchos trabajos sobre el tema, en esta Tesis se proponen diferentes técnicas para evaluar el estado de una estructura basándose exclusivamente en la transmisibilidad. En primer lugar, se propone un indicador de daño basado en un nuevo parámetro, la coherencia de transmisibilidad; El indicador se ha valido mediante resultados numéricos y experimentales obtenidos sobre un pórtico de tres pisos. En segundo lugar, la distancia de Mahalanobis se aplica sobre la transmisibilidad como procedimiento para detectar variaciones estructurales provocadas por el daño. Este método se ha validado con éxito sobre una viga libre-libre ensayada experimentalmente. En tercer lugar, se ha implementado una red neuronal basada en medidas de transmisibilidad como metodología de predicción de daño sobre una viga simulada numéricamente. ABSTRACT Structural health monitoring has experienced a huge development from several decades ago since the cost of rehabilitation of structures such as oil pipes, bridges and tall buildings is very high. In the last two decades, a lot of methods able to identify the real stage of a structure have been developed basing on both models and experimental data. Modal testing is the most common; by carrying out the experimental modal analysis of a structure, some parameters, such as frequency, mode shapes and damping, as well as the frequency response function of the structure can be obtained. From these parameters, different damage indicators have been proposed. However, for complex and large structures, any frequency domain approach that relies on frequency response function estimation would be of difficult application since an assumption of the input excitations to the system should be carried out. Operational modal analysis uses only output signals to extract the structural dynamic parameters and, therefore, to identify the structural stage. In this sense, within operational modal analysis, transmissibility has attracted a lot of attention in the scientific field in the last decade. In this work new damage detection approaches based on transmissibility are developed. Firstly, a new theory of transmissibility coherence is developed and it is tested with a three-floor-structure both in simulation and in experimental data analysis; secondly, Mahalanobis distance is taken into use with the transmissibility, and a free-free beam is used to test the approach performance; thirdly, neural networks are used in transmissibility for structural health monitoring; a simulated beam is used to validate the proposed method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El control del estado en el que se encuentran las estructuras ha experimentado un gran auge desde hace varias décadas, debido a que los costes de rehabilitación de estructuras tales como los oleoductos, los puentes, los edificios y otras más son muy elevados. En las últimas dos décadas, se han desarrollado una gran cantidad de métodos que permiten identificar el estado real de una estructura, basándose en modelos físicos y datos de ensayos. El ensayo modal es el más común; mediante el análisis modal experimental de una estructura se pueden determinar parámetros como la frecuencia, los modos de vibración y la amortiguación y también la función de respuesta en frecuencia de la estructura. Mediante estos parámetros se pueden implementar diferentes indicadores de daño. Sin embargo, para estructuras complejas y grandes, la implementación de metodologías basadas en la función de respuesta en frecuencia requeriría realizar hipótesis sobre la fuerza utilizada para excitar la estructura. Dado que el análisis modal operacional utiliza solamente las señales de respuesta del sistema para extraer los parámetros dinámicos estructurales y, por tanto, para evaluar el estado de una estructura, el uso de la transmisibilidad sería posible. En este sentido, dentro del análisis modal operacional, la transmisibilidad ha concentrado mucha atención en el mundo científico en la última década. Aunque se han publicado muchos trabajos sobre el tema, en esta Tesis se proponen diferentes técnicas para evaluar el estado de una estructura basándose exclusivamente en la transmisibilidad. En primer lugar, se propone un indicador de daño basado en un nuevo parámetro, la coherencia de transmisibilidad; El indicador se ha valido mediante resultados numéricos y experimentales obtenidos sobre un pórtico de tres pisos. En segundo lugar, la distancia de Mahalanobis se aplica sobre la transmisibilidad como procedimiento para detectar variaciones estructurales provocadas por el daño. Este método se ha validado con éxito sobre una viga libre-libre ensayada experimentalmente. En tercer lugar, se ha implementado una red neuronal basada en medidas de transmisibilidad como metodología de predicción de daño sobre una viga simulada numéricamente. ABSTRACT Structural health monitoring has experienced a huge development from several decades ago since the cost of rehabilitation of structures such as oil pipes, bridges and tall buildings is very high. In the last two decades, a lot of methods able to identify the real stage of a structure have been developed basing on both models and experimental data. Modal testing is the most common; by carrying out the experimental modal analysis of a structure, some parameters, such as frequency, mode shapes and damping, as well as the frequency response function of the structure can be obtained. From these parameters, different damage indicators have been proposed. However, for complex and large structures, any frequency domain approach that relies on frequency response function estimation would be of difficult application since an assumption of the input excitations to the system should be carried out. Operational modal analysis uses only output signals to extract the structural dynamic parameters and, therefore, to identify the structural stage. In this sense, within operational modal analysis, transmissibility has attracted a lot of attention in the scientific field in the last decade. In this work new damage detection approaches based on transmissibility are developed. Firstly, a new theory of transmissibility coherence is developed and it is tested with a three-floor-structure both in simulation and in experimental data analysis; secondly, Mahalanobis distance is taken into use with the transmissibility, and a free-free beam is used to test the approach performance; thirdly, neural networks are used in transmissibility for structural health monitoring; a simulated beam is used to validate the proposed method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper proposes a new application of non-parametric statistical processing of signals recorded from vibration tests for damage detection and evaluation on I-section steel segments. The steel segments investigated constitute the energy dissipating part of a new type of hysteretic damper that is used for passive control of buildings and civil engineering structures subjected to earthquake-type dynamic loadings. Two I-section steel segments with different levels of damage were instrumented with piezoceramic sensors and subjected to controlled white noise random vibrations. The signals recorded during the tests were processed using two non-parametric methods (the power spectral density method and the frequency response function method) that had never previously been applied to hysteretic dampers. The appropriateness of these methods for quantifying the level of damage on the I-shape steel segments is validated experimentally. Based on the results of the random vibrations, the paper proposes a new index that predicts the level of damage and the proximity of failure of the hysteretic damper