989 resultados para Fracture internal fixation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fractures of the severely atrophic (<10 mm) edentulous mandible are not common, and these fractures with a vertical height of 10 mm or less have long been recognized as being particularly problematic. Although there are advances in the treatment of the atrophic mandibular fracture, the treatment remains controversial. There are some options for treatment planning because of using small miniplates to large reconstruction plates. However, when the fixation method fails, it causes malunion, nonunion, and/or infection, and sometimes it has been associated with large bone defects. The authors describe a clinical report of a failed miniplate fixation for atrophic mandibular fracture management. The authors used a load-bearing reconstruction plate combined with autogenous bone graft from iliac crest for this retreatment. The authors show a follow-up of 6 months, with union of the fracture line and no complication postoperatively. © 2013 by Mutaz B. Habal, MD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The surgical treatment of mandibular condyle fractures currently offers several possibilities for stable internal fixation. In this study, a finite element model evaluation was performed of three different methods for osteosynthesis of low subcondylar fractures: (1) two four-hole straight plates, (2) one seven-hole lambda plate, and (3) one four-hole trapezoidal plate. The finite element model evaluation considered a load applied to the first molar on the contralateral side to the fracture. Results showed that, although the three methods are capable of withstanding functional loading, the lambda plate displayed a more homogeneous stress distribution for both osteosynthesis material and bone and may be a better method when single-plate fixation is the option.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This is a position paper from the 2nd International Bone Research Association (IBRA) Symposium for Condylar Fracture Osteosynthesis 2012 was held at Marseille, succeeding the first congress in Strasbourg, France, in 2007. The goal of this IBRA symposium and this paper was to evaluate current trends and potential changes of treatment strategies for mandibular condylar fractures, which remain controversial over the past decades.Methods: Using a cross-sectional study design, we enrolled the consensus based on the panel of experts and participants in the IBRA Symposium 2012. The outcomes of interest were the panel and electronic votes on management of condylar base, neck and head fractures, and panel votes on endoscopic and paediatric condylar fractures. Appropriate descriptive and univariate statistics were used.Results: The consensus derived from 14 experts and 41 participant surgeons, using 12 case scenarios and 27 statements. The experts and participants had similar decision on the treatment of condylar base, neck and head fractures, as well as similar opinion on complications of condylar fracture osteosynthesis. They had a parallel agreement on using open reduction with internal fixation (ORIF) as treatment of choice for condylar base and neck fractures in adults. Endoscopic approaches should be considered for selected cases, such as condylar base fractures with lateral displacement. There was also a growing tendency to perform ORIF in condylar head fractures. The experts also agreed to treat children (> 12 years old) in the same way as adults and to consider open reduction in severely displaced and dislocated fractures even in younger children. Nevertheless, non-surgical treatment should be the first choice for children <6 years of age. The decision to perform surgery in children was based on factors influencing facial growth, appropriate age for ORIF, and disagreement to use resorbable materials in children.Conclusions: The experts and participating surgeons had comparable opinion on management of condylar fractures and complications of ORIF. Compared to the first Condylar Fracture Symposium 2007 in Strasbourg, ORIF may now be considered as the gold standard for both condylar base and neck fractures with displacement and dislocation. Although ORIF in condylar head fractures in adults and condylar fractures in children with mixed dentition is highly recommended, but this recommendation requires further investigations. (C) 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aims to compare three types of internal fixation for fractures of the mandibular angle. Mechanical testing was performed on replicas of polyurethane hemimandibles sectioned at the angle region to simulate a fracture and fixed with three different hardwares. Fixation devices enrolled on this survey included the grid plates with and without an intermediate bar and the method described by Champy and colleagues in 1978 and the sample consisted of 10 hemimandibles for each group. Vertical loadings were applied on each hemimandible and recorded after a vertical displacement of 3 and 5 mm. Statistical analysis was made by means of the variance analysis (ANOVA) and the Duncan test with a significance level of 5%. The Champy technique showed a statistically significant increased resistance when compared to the grid plates after vertical displacements of 3 and 5 mm. The results of this survey suggest that the Champy technique, when compared to the grid plate positioned at the middle of the mandibular bone (placement site selected for this study), is more resistant than the grid plate and that the inclusion or not of an intermediate bar to the grid plates does not improve its resistance after linear vertical loadings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fractures of the mandibular angle deserve particular attention because they represent the highest percentage of mandibular fractures and have the highest postsurgical complication rate, making them the most challenging and unpredictable mandibular fractures to treat. Despite the evolution in the treatment of maxillofacial trauma and fixation methods, no single treatment modality has been revealed to be ideal for mandibular angle fractures. Several methods of internal fixation have been studied with great variation in complications rates, especially postoperative infections. Recently, new studies have shown reduction of postsurgical complications rates using three-dimensional plates to treat mandibular angle fractures. Nevertheless, only few surgeons have used this type of plate for the treatment of mandibular angle fractures. The aim of this clinical report was to describe a case of a patient with a mandibular angle fracture treated by an intraoral approach and a three-dimensional rectangular grid miniplate with 4 holes, which was stabilized with monocortical screws. The authors show a follow-up of 8 months, without infection and with occlusal stability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bennett fractures are unstable, and, with inadequate treatment, lead to osteoarthritis, weakness and loss of function of the first carpometacarpal joint. This study focuses on long-term functional and radiological outcomes after open reduction and internal fixation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: Closed reduction and internal fixation by an anterior approach is an established option for operative treatment of displaced Type II odontoid fractures. In elderly patients, however, inadequate screw purchase in osteoporotic bone can result in severe procedure-related complications. PURPOSE: To improve the stability of odontoid fracture screw fixation in the elderly using a new technique that includes injection of polymethylmethacrylat (PMMA) cement into the C2 body. STUDY DESIGN: Retrospective review of hospital and outpatient records as well as radiographs of elderly patients treated in a university hospital department of orthopedic surgery. PATIENT SAMPLE: Twenty-four elderly patients (8 males and 16 females; mean age, 81 years; range, 62-98 years) with Type II fractures of the dens. OUTCOME MEASURES: Complications, cement leakage (symptomatic/asymptomatic), operation time, loss of reduction, pseudarthrosis and revision surgery, patient complaints, return to normal activities, and signs of neurologic complications were all documented. METHODS: After closed reduction and anterior approach to the inferior border of C2, a guide wire is advanced to the tip of the odontoid under biplanar fluoroscopic control. Before the insertion of one cannulated, self-drilling, short thread screws, a 12 gauge Yamshidi cannula is inserted from anterior and 1 to 3 mL of high-viscosity PMMA cement is injected into the anteroinferior portion of the C2 body. During polymerization of the cement, the screws are further inserted using a lag-screw compression technique. The cervical spine then is immobilized with a soft collar for 8 weeks postoperatively. RESULTS: Anatomical reduction of the dens was achieved in all 24 patients. Mean operative time was 64 minutes (40-90 minutes). Early loss of reduction occurred in three patients, but revision surgery was indicated in only one patient 2 days after primary surgery. One patient died within the first eight postoperative weeks, one within 3 months after surgery. In five patients, asymptomatic cement leakage was observed (into the C1-C2 joint in three patients, into the fracture in two). Conventional radiologic follow-up at 2 and 6 months confirmed anatomical healing in 16 of the19 patients with complete follow-up. In two patients, the fractures healed in slight dorsal angulation; one patient developed a asymptomatic pseudarthrosis. All patients were able to resume their pretrauma level of activity. CONCLUSIONS: Cement augmentation of the screw in Type II odontoid fractures in elderly patients is technically feasible in a clinical setting with a low complication rate. This technique may improve screw purchase, especially in the osteoporotic C2 body.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION To present the accuracy of reduction, complications and results two years after open reduction and internal fixation of displaced acetabular fractures involving the anterior column (AC) through the Pararectus approach. Frequencies for conversion to total hip replacement in the early follow up, the clinical outcome in preserved hips, and the need for an extension of the approach (1st window of the ilioinguinal approach) are compared to the literature about the modified Stoppa approach. METHODS Forty-eight patients (mean age 62 years, range: 16–98; 41 male) with displaced acetabular fractures involving the AC (AC: n = 9; transverse fracture: n = 2; AC and hemitransverse: n = 24; both column: n = 13) were treated between 12/2009 and 12/2011 using the Pararectus approach. Surgical data and accuracy of reduction (using computed tomography) were assessed. Patients were routinely followed up at eight weeks, 6, 12 and 24 months postoperatively. Failure was defined as the need for total hip arthroplasty. Twenty-four months postoperatively the outcome was rated according to Matta. RESULTS In four patients there were four intraoperative complications (minor vascular damage in two, small perforations of the peritoneum in two) which were managed intraoperatively. Fracture reduction showed statistically significant decreases (mean ± SD, pre- vs. postoperative, in mm) in “step-offs”: 2.6 ± 1.9 vs. 0.1 ± 0.3, p < 0.001 and “gaps”: 11.2 ± 6.8 vs. 0.7 ± 0.9, p < 0.001. Accuracy of reduction was “anatomical” in 45, “imperfect” in three. Five (13%) from 38 available patients required a total hip arthroplasty. Of 33 patients with a preserved hip the clinical outcome was graded as “excellent” in 13 or “good” in 20; radiographically, 27 were graded as “excellent”, four as “good” and two as “fair”. An extension of the approach was infrequently used (1st window ilioinguinal approach in 2%, mini-incision at the iliac crest in 21%). CONCLUSION In the treatment of acetabular fractures involving the anterior column the Pararectus approach allowed for anatomic restoration with minimal access morbidity. Results obtained by means of the Pararectus approach after two years at least parallel those reported after utilisation of the modified Stoppa approach. In contrast to the modified Stoppa approach, a relevant extension of the Pararectus approach was almost not necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Mechanical evaluation of a novel screw position used for repair in a type III distal phalanx fracture model and assessment of solar canal penetration (SCP). STUDY DESIGN: Experimental study. SAMPLE POPULATION: Disarticulated equine hooves (n = 24) and 24 isolated distal phalanges. METHODS: Hooves/distal phalanges cut in a sagittal plane were repaired with 1 of 2 different cortical screw placements in lag fashion. In group 1 (conventional screw placement), the screw was inserted halfway between the proximal border of the solar canal (SC) and the subchondral bone surface on a line parallel to the dorsal cortex, whereas in group 2, the screw was inserted more palmar/plantar, where a perpendicular line drawn from the group 1 position reached the palmar/plantar cortex. Construct strength was evaluated by 3-point bending to failure. SCP was assessed by CT imaging and macroscopically. RESULTS: Screws were significantly longer in group 2 and in forelimbs. Group 2 isolated distal phalanges had a significantly more rigid fixation compared with the conventional screw position (maximum point at failure 31%, bending stiffness 41% higher). Lumen reduction of the SC was observed in 13/52 specimens (all from group 2), of which 9 were forelimbs. CONCLUSIONS: More distal screw positioning compared with the conventionally recommended screw position for internal fixation of type III distal phalangeal fractures allows placement of a longer screw and renders a more rigid fracture fixation. The novel screw position, however, carries a higher risk of SCP

Relevância:

90.00% 90.00%

Publicador:

Resumo:

To evaluate patients with transverse fractures of the shaft of the humerus treated with indirect reduction and internal fixation with plate and screws through minimally invasive technique. Inclusion criteria were adult patients with transverse diaphyseal fractures of the humerus closed, isolated or not occurring within 15 days of the initial trauma. Exclusion criteria were patients with compound fractures. In two patients, proximal screw loosening occurred, however, the fractures consolidated in the same mean time as the rest of the series. Consolidation with up to 5 degrees of varus occurred in five cases and extension deficit was observed in the patient with olecranon fracture treated with tension band, which was not considered as a complication. There was no recurrence of infection or iatrogenic radial nerve injury. It can be concluded that minimally invasive osteosynthesis with bridge plate can be considered a safe and effective option for the treatment of transverse fractures of the humeral shaft. Level of Evidence III, Therapeutic Study.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: The objective of the study was to compare the functional and aesthetic results of fractured orbital wall reconstruction with an auricular cartilage graft or absorbable polyacid copolymer. Materials and Methods: Twenty patients with blow-out orbital fracture/orbital floor associated or not with the medial wall were assessed by the same craniofacial surgical group. All were evaluated preoperatively and postoperatively by an ophthalmologist for diplopia, enophthalmos, exophthalmos, sensitivity, ophthalmic reflexes, intraocular pressure, and visual field. The patients were subjected to a preoperative facial multislice computed tomographic scan, repeated 6 months after surgery. Eight patients underwent reconstruction with an auricular cartilage graft, and 12 patients, with blade absorbable polyacid copolymer. Subtarsal access was used for all patients. Results: Two patients showed temporary ectropion, 1 in each group. All patients presented satisfactory ocular function, and all tests revealed good orbital delineation, orbital symmetry, periorbital sinus individualization, and reduction of blow-out. Conclusions: The blow-out orbital wall reconstruction can be performed with the use of an auricular cartilage or with a blade absorbable copolymer without differences regarding functional or aesthetic complications and sequelae.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The long-term outcome of 25 patients with bimalleolar fractures of the ankle was assessed ten to fourteen years following their fractures using the Phillips scoring system. All patients had undergone open reduction and anatomical internal fixation (as described in their operative notes in the medical records). 52 % of patients had a good or excellent overall outcome while 24% had a poor overall outcome. This study has the longest follow-up period (10 to 14 years) to date on the outcomes of internal fixation of bimalleolar ankle fractures and demonstrates a higher percentage of poorer outcomes than has been previously described. This trend appears to be predictable as other studies with shorter term follow-up have already established a trend of increasing radiological evidence of post-traumatic arthritis with successively longer-term outcome reports.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dislocated compound fractures of the proximal humerus are often difficult to treat. The choice of treatment influences the final functional result. From 1984-1991 108 patients with dislocated compound fractures of the proximal humerus were operated with a T-plate osteosynthesis, retrospectively examined and classified according to the Neer-Classification. At an average follow up time of 5 years 72 patients had a clinical and radiological examination. 68% of these patients with 3-fragment fractures and 80% with 4-fragment fractures showed a modest to unsatisfactory result caused by fracture biology, imprecise fracture reduction or poor surgical procedure. Incorrect position of T-plates and inadequate material were distinguishable. The T-plate which was widely used in the late eighties for internal fixation has to be considered a failure for these particular types of fractures and should be limited for Collum chirurgicum fractures.