973 resultados para Forced-choice method
Resumo:
Abstract: Loss of central vision caused by age-related macular degeneration (AMD) is a problem affecting increasingly large numbers of people within the ageing population. AMD is the leading cause of blindness in the developed world, with estimates of over 600,000 people affected in the UK . Central vision loss can be devastating for the sufferer, with vision loss impacting on the ability to carry out daily activities. In particular, inability to read is linked to higher rates of depression in AMD sufferers compared to age-matched controls. Methods to improve reading ability in the presence of central vision loss will help maintain independence and quality of life for those affected. Various attempts to improve reading with central vision loss have been made. Most textual manipulations, including font size, have led to only modest gains in reading speed. Previous experimental work and theoretical arguments on spatial integrative properties of the peripheral retina suggest that ‘visual crowding’ may be a major factor contributing to inefficient reading. Crowding refers to the phenomena in which juxtaposed targets viewed eccentrically may be difficult to identify. Manipulating text spacing of reading material may be a simple method that reduces crowding and benefits reading ability in macular disease patients. In this thesis the effect of textual manipulation on reading speed was investigated, firstly for normally sighted observers using eccentric viewing, and secondly for observers with central vision loss. Test stimuli mimicked normal reading conditions by using whole sentences that required normal saccadic eye movements and observer comprehension. Preliminary measures on normally-sighted observers (n = 2) used forced-choice procedures in conjunction with the method of constant stimuli. Psychometric functions relating the proportion of correct responses to exposure time were determined for text size, font type (Lucida Sans and Times New Roman) and text spacing, with threshold exposure time (75% correct responses) used as a measure of reading performance. The results of these initial measures were used to derive an appropriate search space, in terms of text spacing, for assessing reading performance in AMD patients. The main clinical measures were completed on a group of macular disease sufferers (n=24). Firstly, high and low contrast reading acuity and critical print size were measured using modified MNREAD test charts, and secondly, the effect of word and line spacing was investigated using a new test, designed specifically for this study, called the Equal Readability Passages (ERP) test. The results from normally-sighted observers were in close agreement with those from the group of macular disease sufferers. Results show that: (i) optimum reading performance was achieved when using both double line and double word spacing; (ii) the effect of line spacing was greater than the effect of word spacing (iii) a text size of approximately 0.85o is sufficiently large for reading at 5o eccentricity. In conclusion, the results suggest that crowding is detrimental to reading with peripheral vision, and its effects can be minimized with a modest increase in text spacing.
Resumo:
Background: The Melbourne Edge Test (MET) is a portable forced-choice edge detection contrast sensitivity (CS) test. The original externally illuminated paper test has been superseded by a backlit version. The aim of this study was to establish normative values for age and to assess change with visual impairment. Method: The MET was administered to 168 people with normal vision (18-93 years old) and 93 patients with visual impairment (39-97 years old). Distance visual acuity (VA) was measured with a log MAR chart. Results: In those eyes without disease, MET CS was stable until the age of 50 years (23.8 ± .7 dB) after which it decreased at a rate of ≈1.5 dB per decade. Compared with normative values, people with low vision were found to have significantly reduced CS, which could not be totally accounted for by reduced VA. Conclusions: The MET provides a quick and easy measure of CS, which highlights a reduction in visual function that may not be detectable using VA measurements. © 2004 The College of Optometrists.
Resumo:
Morgan, Dillenburger, Raphael, and Solomon have shown that observers can use different response strategies when unsure of their answer, and, thus, they can voluntarily shift the location of the psychometric function estimated with the method of single stimuli (MSS; sometimes also referred to as the single-interval, two-alternative method). They wondered whether MSS could distinguish response bias from a true perceptual effect that would also shift the location of the psychometric function. We demonstrate theoretically that the inability to distinguish response bias from perceptual effects is an inherent shortcoming of MSS, although a three-response format including also an "undecided" response option may solve the problem under restrictive assumptions whose validity cannot be tested with MSS data. We also show that a proper two-alternative forced-choice (2AFC) task with the three-response format is free of all these problems so that bias and perceptual effects can easily be separated out. The use of a three-response 2AFC format is essential to eliminate a confound (response bias) in studies of perceptual effects and, hence, to eliminate a threat to the internal validity of research in this area.
Resumo:
Ulrich and Vorberg (2009) presented a method that fits distinct functions for each order of presentation of standard and test stimuli in a two-alternative forced-choice (2AFC) discrimination task, which removes the contaminating influence of order effects from estimates of the difference limen. The two functions are fitted simultaneously under the constraint that their average evaluates to 0.5 when test and standard have the same magnitude, which was regarded as a general property of 2AFC tasks. This constraint implies that physical identity produces indistinguishability, which is valid when test and standard are identical except for magnitude along the dimension of comparison. However, indistinguishability does not occur at physical identity when test and standard differ on dimensions other than that along which they are compared (e.g., vertical and horizontal lines of the same length are not perceived to have the same length). In these cases, the method of Ulrich and Vorberg cannot be used. We propose a generalization of their method for use in such cases and illustrate it with data from a 2AFC experiment involving length discrimination of horizontal and vertical lines. The resultant data could be fitted with our generalization but not with the method of Ulrich and Vorberg. Further extensions of this method are discussed.
Resumo:
The standard difference model of two-alternative forced-choice (2AFC) tasks implies that performance should be the same when the target is presented in the first or the second interval. Empirical data often show “interval bias” in that percentage correct differs significantly when the signal is presented in the first or the second interval. We present an extension of the standard difference model that accounts for interval bias by incorporating an indifference zone around the null value of the decision variable. Analytical predictions are derived which reveal how interval bias may occur when data generated by the guessing model are analyzed as prescribed by the standard difference model. Parameter estimation methods and goodness-of-fit testing approaches for the guessing model are also developed and presented. A simulation study is included whose results show that the parameters of the guessing model can be estimated accurately. Finally, the guessing model is tested empirically in a 2AFC detection procedure in which guesses were explicitly recorded. The results support the guessing model and indicate that interval bias is not observed when guesses are separated out.
Resumo:
Objective: Elevated levels of alcohol consumption among university students are well documented. Policymakers have attempted to combat this issue at a university, national and international level. Tailoring public health policy to effectively tackle alcohol use is crucial. Using Q-methodology, the current study aims to develop a typology of alcohol consumption in the Irish university student population. Setting: A large Irish university. Participants Hundreds of possible statements on types of consumption were generated from a systematic review and a set of one-on-one interviews. These were reduced to 36 statements, 6 statements which define each of the 6 previously defined consumption types. Participants were advised to scan through the 36 statements and fill the statements into a ‘forced choice, standardised distribution’. Following this, a 45–90 min interview was conducted with students to illuminate subjectivity surrounding alcohol consumption. Analysis was conducted using PQ Method and NVivo software. Principal component analysis, followed by varimax rotation, was conducted to uncover the final factor information. Results: In total, 43 students completed the Q-study: 19 men and 24 women. A typology describing 4 distinct groupings of alcohol consumer was uncovered: the guarded drinker, the calculated hedonist, the peer-influenced drinker and the inevitable binger. Factor loadings of each of the consumer groupings were noted for type description. Conclusions: This is the first study to propose ideal types of alcohol consumption among a university student population. Further research is required to investigate the degree to which each of these ideal types is subscribed. However, this typology, in addition to informing public policy and strategies, will be a valuable analytic tool in future research.
Resumo:
Dois experimentos foram conduzidos para determinar a composição química, os valores de energia e os coeficientes de digestibilidade dos aminoácidos, do farelo de arroz integral (FAI) e da quirera de arroz (QA). No primeiro estudo, foram utilizadas 144 aves, com 21 dias de idade, machos, linhagem Cobb, que tiveram suas excretas totalmente coletadas para determinação da energia metabolizável aparente (EMA) e energia metabolizável aparente corrigida (EMAn). O delineamento experimental foi inteiramente casualizado, com três tratamentos e seis repetições, com oito aves cada. No segundo experimento, foi utilizado o método de alimentação forçada para a determinação dos coeficientes de digestibilidade dos aminoácidos. O delineamento foi inteiramente casualizado, com dois alimentos e um jejum e seis repetições com um galo cada. Os valores de MS, PB, EE, FB, EMA e EMAn foram, respectivamente, para FAI: 88,6%; 11,8%; 15,3%; 10,2%; 2968kcal kg-1 e 2804kcal kg-1 e para QA: 93,5%; 9,1%; 0,73%; 0,45%; 3338kcal kg-1 e 3239kcal kg-1. Os valores médios encontrados dos coeficientes de digestibilidade de aminoácidos essenciais e não essenciais foram, respectivamente, de 75,9% e 73,9%, para FAI, e 77,9% e 76,5%, para QA. Embora tenham apresentado níveis inferiores de energia, FAI e a QA podem ser utilizados nas rações de aves em substituição ao milho, uma vez que tiveram níveis maiores de proteína bruta e aminoácidos digestíveis.
Resumo:
Frequency, recency, and type of prior exposure to very low-and high-frequency words were manipulated in a 3-phase (i.e., familiarization training, study, and test) design. Increasing the frequency with which a definition for a very low-frequency word was provided during familiarization facilitated the word's recognition in both yes-no (Experiment 1) and forced-choice paradigms (Experiment 2). Recognition of very low-frequency words not accompanied by a definition during familiarization first increased, then decreased as familiarization frequency increased (Experiment I). Reasons for these differences were investigated in Experiment 3 using judgments of recency and frequency. Results suggested that prior familiarization of a very low-frequency word with its definition may allow a more adequate episodic representation of the word to be formed during a subsequent study trial. Theoretical implications of these results for current models of memory are discussed.
Resumo:
Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.
Resumo:
Aim - A quantative primary study to determine whether increasing source to image distance (SID), with and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces dose whilst still producing an image of diagnostic quality. Methods - Using a computed radiography (CR) system, an anthropomorphic pelvic phantom was positioned for an AP examination using the table bucky. SID was initially set at 110 cm, with tube potential set at a constant 75 kVp, with two outer chambers selected and a fine focal spot of 0.6 mm. SID was then varied from 90 cm to 140 cm with two exposures made at each 5 cm interval, one using the AEC and another with a constant 16 mAs derived from the initial exposure. Effective dose (E) and entrance surface dose (ESD) were calculated for each acquisition. Seven experienced observers blindly graded image quality using a 5-point Likert scale and 2 Alternative Forced Choice software. Signal-to-Noise Ratio (SNR) was calculated for comparison. For each acquisition, femoral head diameter was also measured for magnification indication. Results - Results demonstrated that when increasing SID from 110 cm to 140 cm, both E and ESD reduced by 3.7% and 17.3% respectively when using AEC and 50.13% and 41.79% respectively, when the constant mAs was used. No significant statistical (T-test) difference (p = 0.967) between image quality was detected when increasing SID, with an intra-observer correlation of 0.77 (95% confidence level). SNR reduced slightly for both AEC (38%) and no AEC (36%) with increasing SID. Conclusion - For CR, increasing SID significantly reduces both E and ESD for AP pelvis imaging without adversely affecting image quality.
Resumo:
Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.
Resumo:
“Cork taint” is a major problem in wine industry and is caused by contamination of wines. This contamination is usually attributed to wine cork stoppers and 2,4,6-trichloroanisole (2,4,6-TCA) is one of the compounds mostly associated to this off-flavour. In this work, a consumer panel performed “forced choice” triangular tests in order to measure Odour Detection Thresholds (ODT) and Taste Detection Thresholds (TDT) of 2,4,6-TCA in water, hydro-alcoholic solutions (11.5% and 18% ethanol) and white and red wines. A paired preference test was also performed by the panel in order to measure Odour Rejection Threshold (ORT) in white and red wine spiked with 2,4,6-TCA. Results obtained show that the ODT and the TDT for 2,4,6-TCA in water were 0.2 and 0.3 ng/L, respectively. In hydro-alcoholic solutions with 11.5% and 18% ethanol the ODT were 4 and 10 ng/L respectively. In red wine the ODT and the TDT were 0.9 and 1.7 ng/L and in white wine were 1.5 and 1.0 ng/L respectively. ORT for white was 10.4 ng/L and for red wines 16.0 ng/L. These results suggest that although this group of consumers detected very low concentrations of 2,4,6-TCA in wines, they did not reject the wine at these low concentration values.
Resumo:
Auditory spatial functions, including the ability to discriminate between the positions of nearby sound sources, are subserved by a large temporo-parieto-frontal network. With the aim of determining whether and when the parietal contribution is critical for auditory spatial discrimination, we applied single pulse transcranial magnetic stimulation on the right parietal cortex 20, 80, 90 and 150 ms post-stimulus onset while participants completed a two-alternative forced choice auditory spatial discrimination task in the left or right hemispace. Our results reveal that transient TMS disruption of right parietal activity impairs spatial discrimination when applied at 20 ms post-stimulus onset for sounds presented in the left (controlateral) hemispace and at 80 ms for sounds presented in the right hemispace. We interpret our finding in terms of a critical role for controlateral temporo-parietal cortices over initial stages of the building-up of auditory spatial representation and for a right hemispheric specialization in integrating the whole auditory space over subsequent, higher-order processing stages.
Resumo:
Contexte¦- Les métastases hépatiques hypovasculaires sont parfois difficile à détecter car très polymorphiques et fréquemment irrégulières. Leurs contrastes sur CT scan hépatique sont souvent faibles.¦- Lors d'un diagnostic, le radiologue ne fixe pas sa vision fovéale sur chaque pixel de l'image. Les expériences de psychophysique avec eye-tracker montrent en effet que le radiologue se concentre sur quelques points spécifiques de l'image appelés fixations. Dans ce travail, nous nous intéresserons aux capacités de détection de l'oeil lorsque l'observateur effectue une saccade entre deux points de fixation. Plus particulièrement, nous nous intéresserons à caractériser les capacités de l'oeil à détecter les signaux se trouvant en dehors de sa vision fovéale, dans ce qu'on appelle, la vision périphérique.¦Objectifs¦- Caractériser l'effet de l'excentricité de la vision sur la détectabilité des contrastes dans le cas de métastases hépatiques hypovasculaires.¦- Récolter des données expérimentales en vue de créer un modèle mathématique qui permettra, à terme, de qualifier le système d'imagerie.¦- → objectifs du TM en soit :¦o prendre en main l'eyetracker¦o traduire une problématique médicale en une expérience scientifique reproductible, quantifiable et qualifiable.¦Méthode¦Nous effectuons une expérience 2AFC (2 Alternative Forced-Choice experiment) afin d'estimer la détectabilité du signal. Pour cela, nous forcerons l'observateur à maintenir son point de fixation à un endroit défini et vérifié par l'eye-tracker. La position del'excentricité du signal tumoral généré sur une coupe de CT hépatique sera le paramètre varié. L'observateur se verra présenté tour à tour deux coupes de CT hépatique, l'une comportant le signal tumoral standardisé et l'autre ne comportant pas le signal. L'observateur devra déterminer quelle image contient la pathologie avec la plus grande probabilité.¦- Cette expérience est un modèle simplifié de la réalité. En effet, le radiologue ne fixe pas un seul point lors de sa recherche mais effectue un "scanpath". Une seconde expérience, dite en free search sera effectuée dans la mesure du temps à disposition. Lors de cette expérience, le signal standardisé sera connu de l'observateur et il n'y aura plus de point de fixation forcée. L'eyetracker suivra le scanpath effectué par l'oeil de l'observateur lors de la recherche du signal sur une coupe de CT scan hépatique. L'intérêt de cette expérience réside dans l'observation de la corrélation entre les saccades et la découverte du signal. Elle permet aussi de vérifier les résultats obtenus lors de la première expérience.¦Résultats escomptés¦- Exp1 : Quantifier l'importance de l'excentricité en radiologie et aider à améliorer la performance de recherche.¦- Exp 2 : tester la validité des résultats obtenus par la première expérience.¦Plus value escomptée¦- Récolte de données pour créer un modèle mathématique capable de déterminer la qualité de l'image radiologique.¦- Possibilité d'extension à la recherche dans les trois dimensions du CT scan hépatique.
Resumo:
The sensitivities of spleen and lymph node cultures for the diagnosis of canine visceral leishmaniasis were compared in 64 anti-Leishmania antibody positive dogs from an endemic area in Brazil. The sensitivity of spleen cultures for Leishmania detection was 97.9%; in lymph node cultures it was 25%. Positive spleen culture was more frequent (p = 0.048, Fisher's exact probability test) in symptomatic (28 out of 33 animals) than in asymptomatic animals (19 out of 31 animals). These results support the use of spleen instead of lymph node aspiration as the choice method for the parasitological diagnosis of the infection.