823 resultados para Forced vital capacity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: Hospitality workers are a population particularly at risk from the noxious effects of environmental tobacco smoke (ETS). The Canton of Vaud, Switzerland banned smoking in public places in September 2009. This prospective study addresses the impact of the ban on the health of hospitality workers. METHODS: ETS exposure was evaluated using a passive sampling device that measures airborne nicotine; lung function was assessed by spirometry; health-related quality of life, ETS exposure symptoms and satisfaction were measured by questionnaire. RESULTS: 105 participants (smokers and non-smokers) were recruited initially and 66 were followed up after one year. ETS exposure was significantly lower after the ban. Hospitality workers had lower pre-ban forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) values than expected. FEV1 remained stable after the ban, with a near-significant increase in the subgroup of asthmatics only. FVC increased at one year follow-up from 90.42% to 93.05% (p = 0.02) in the entire cohort; women, non-smokers and older participants gained the greatest benefit. The health survey showed an increase in physical wellbeing after the ban, the greatest benefit being observed in non-smokers. ETS exposure symptoms were less frequent after the ban, especially red and irritated eyes and sneezing. The new law was judged useful and satisfactory by the vast majority of employees, including smokers. CONCLUSION: The recent cantonal ban on smoking in public places brought about an improvement in lung function, physical well-being and ETS symptoms of hospitality workers, including smokers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to assess the effects of an extreme mountain ultramarathon (MUM, 330 km, 24,000 D+) on lung function. Twenty-nine experienced male ultramarathon runners performed longitudinally [before (pre), during (mid), and immediately after (post) a MUM] a battery of pulmonary function tests. The tests included measurements of forced vital capacity, forced expiratory volume in 1 s, peak flow, inspiratory capacity, and maximum voluntary ventilation in 12 s (MVV12). A significant reduction in the running speed was observed (-43.0% between pre-mid and mid-post; P < 0.001). Expiratory function declined significantly at mid (P < 0.05) and at post (P < 0.05). A similar trend was observed for inspiratory function (P < 0.05). MVV12 declined at mid (P < 0.05) and further decreased at post (P < 0.05). Furthermore, there are significant negative correlations between performance time and MVV12 pre-race (R = -0.54, P = 0.02) as well as changes in MVV12 between pre- and post-race (R = -0.53, P = 0.009). It is concluded that during an extreme MUM, a continuous decline in pulmonary function was observed, likely attributable to the high levels of ventilation required during this MUM in a harsh mountainous environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The impact of abnormal spirometric findings on risk for incident heart failure among older adults without clinically apparent lung disease is not well elucidated.METHODS: We evaluated the association of baseline lung function with incident heart failure, defined as first hospitalization for heart failure, in 2125 participants of the community-based Health, Aging, and Body Composition (Health ABC) Study (age, 73.6 +/- 2.9 years; 50.5% men; 62.3% white; 37.7% black) without prevalent lung disease or heart failure. Abnormal lung function was defined either as forced vital capacity (FVC) or forced expiratory volume in 1(st) second (FEV1) to FVC ratio below lower limit of normal. Percent predicted FVC and FEV1 also were assessed as continuous variables.RESULTS: During follow-up (median, 9.4 years), heart failure developed in 68 of 350 (19.4%) participants with abnormal baseline lung function, as compared with 172 of 1775 (9.7%) participants with normal lung function (hazard ratio [HR] 2.31; 95% confidence interval [CI], 1.74-3.07; P <.001). This increased risk persisted after adjusting for previously identified heart failure risk factors in the Health ABC Study, body mass index, incident coronary heart disease, and inflammatory markers (HR 1.83; 95% CI, 1.33-2.50; P <.001). Percent predicted (%) FVC and FEV 1 had a linear association with heart failure risk (HR 1.21; 95% CI, 1.11-1.32 and 1.18; 95% CI, 1.10-1.26, per 10% lower % FVC and % FEV1, respectively; both P <.001 in fully adjusted models). Findings were consistent in sex and race subgroups and for heart failure with preserved or reduced ejection fraction.CONCLUSIONS: Abnormal spirometric findings in older adults without clinical lung disease are associated with increased heart failure risk. (C) 2011 Elsevier Inc. All rights reserved. The American Journal of Medicine (2011) 124, 334-341

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The long-term efficacy and safety of aclidinium bromide, a novel, long-acting muscarinic antagonist, were investigated in patients with moderate to severe chronic obstructive pulmonary disease (COPD). Methods: In two double-blind, 52-week studies, ACCLAIM/COPD I (n = 843) and II (n = 804), patients were randomised to inhaled aclidinium 200 μg or placebo once-daily. Patients were required to have a postbronchodilator forced expiratory volume in 1 second (FEV1)/forced vital capacity ratio of ≤70% and FEV1 <80% of the predicted value. The primary endpoint was trough FEV1 at 12 and 28 weeks. Secondary endpoints were health status measured by St George"s Respiratory Questionnaire (SGRQ) and time to first moderate or severe COPD exacerbation. Results: At 12 and 28 weeks, aclidinium improved trough FEV1 versus placebo in ACCLAIM/COPD I (by 61 and 67 mL; both p < 0.001) and ACCLAIM/COPD II (by 63 and 59 mL; both p < 0.001). More patients had a SGRQ improvement ≥4 units at 52 weeks with aclidinium versus placebo in ACCLAIM/COPD I (48.1% versus 39.5%; p = 0.025) and ACCLAIM/COPD II (39.0% versus 32.8%; p = 0.074). The time to first exacerbation was significantly delayed by aclidinium in ACCLAIM/COPD II (hazard ratio [HR] 0.7; 95% confidence interval [CI] 0.55 to 0.92; p = 0.01), but not ACCLAIM/COPD I (HR 1.0; 95% CI 0.72 to 1.33; p = 0.9). Adverse events were minor in both studies. Conclusion: Aclidinium is effective and well tolerated in patients with moderate to severe COPD. Trial registration: ClinicalTrials.gov: NCT00363896 ACCLAIM/COPD I) and NCT00358436 (ACCLAIM/COPD II).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Hemidiaphragmatic paresis after ultrasound-guided interscalene brachial plexus block is reported to occur in up to 100% of patients. We tested the hypothesis that an injection lateral to the brachial plexus sheath reduces the incidence of hemidiaphragmatic paresis compared with a conventional intrafascial injection, while providing similar analgesia. METHODS: Forty ASA I-III patients undergoing elective shoulder and clavicle surgery under general anaesthesia were randomized to receive an ultrasound-guided interscalene brachial plexus block for analgesia, using 20 ml bupivacaine 0.5% with epinephrine 1:200 000 injected either between C5 and C6 within the interscalene groove (conventional intrafascial injection), or 4 mm lateral to the brachial plexus sheath (extrafascial injection). The primary outcome was incidence of hemidiaphragmatic paresis (diaphragmatic excursion reduction >75%), measured by M-mode ultrasonography, before and 30 min after the procedure. Secondary outcomes were forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow. Additional outcomes included time to first opioid request and pain scores at 24 h postoperatively (numeric rating scale, 0-10). RESULTS: The incidences of hemidiaphragmatic paresis were 90% (95% CI: 68-99%) and 21% (95% CI: 6-46%) in the conventional and extrafascial injection groups, respectively (P<0.0001). Other respiratory outcomes were significantly better preserved in the extrafascial injection group. The mean time to first opioid request was similar between groups (conventional: 802 min [95% CI: 620-984 min]; extrafascial: 973 min [95% CI: 791-1155 min]; P=0.19) as were pain scores at 24 h postoperatively (conventional: 1.6 [95% CI: 0.9-2.2]; extrafascial: 1.6 [95% CI: 0.8-2.4]; P=0.97). CONCLUSIONS: Ultrasound-guided interscalene brachial plexus block with an extrafascial injection reduces the incidence of hemidiaphragmatic paresis and impact on respiratory function while providing similar analgesia, when compared with a conventional injection. CLINICAL TRIAL REGISTRATION: NCT02074397.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to determine if there is a health-related quality of life (HRQL) instrument, generic or specific, that better represents functional capacity dysfunction in idiopathic pulmonary fibrosis (IPF) patients. HRQL was evaluated in 20 IPF patients using generic and specific questionnaires (Medical Outcomes Short Form 36 (SF-36) and Saint George's Respiratory Questionnaire (SGRQ), respectively). Functional status was evaluated by pulmonary function tests, 6-min walking distance test (6MWDT) and dyspnea indexes (baseline dyspnea index) at rest and after exercise (modified Borg scale). There was a restrictive pattern with impairment of diffusion capacity (total lung capacity, TLC = 71.5 ± 15.6%, forced vital capacity = 70.4 ± 19.4%, and carbon monoxide diffusing capacity = 41.5 ± 16.2% of predicted value), a reduction in exercise capacity (6MWDT = 435.6 ± 95.5 m) and an increase of perceived dyspnea score at rest and during exercise (6 ± 2.5 and 7.1 ± 1.3, respectively). Both questionnaires presented correlation with some functional parameters (TLC, forced expiratory volume in 1 s and carbon monoxide diffusing capacity) and the best correlation was with TLC. Almost all of the SGRQ domains presented a strong correlation with functional status, while in SF-36 only physical function and vitality presented a good correlation with functional status. Dyspnea index at rest and 6MWDT also presented a good correlation with HRQL. Our results suggest that a specific instead of a generic questionnaire is a more appropriate instrument for HRQL evaluation in IPF patients and that TLC is the functional parameter showing best correlation with HRQL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present cross-sectional, population-based study was designed to evaluate the performance of the FEV1/FEV6 ratio for the detection of airway-obstructed subjects compared to the FEV1/FVC <0.70 fixed ratio test, as well as the lower limit of normality (LLN) for 1000 subjects ³40 years of age in the metropolitan area of São Paulo, SP, Brazil. After the exclusion of 37 (3.7%) spirometries, a total of 963 pre-bronchodilator (BD) and 918 post-BD curves were constructed. The majority of the post-BD curves (93.1%) were of very good quality and achieved grade A (762 curves) or B (93 curves). The FEV1/FEV6 and FEV1/FVC ratios were highly correlated (r² = 0.92, P < 0.000). Two receiver operator characteristic curves were constructed in order to express the imbalance between the sensitivity and specificity of the FEV1/FEV6 ratio compared to two FEV1/FVC cut-off points for airway obstruction: equal to 70 (area under the curve = 0.98, P < 0.0001) and the LLN (area under the curve = 0.97, P < 0.0001), in the post-BD curves. According to an FEV1/FVC <0.70, the cut-off point for the FEV1/FEV6 ratio with the highest sum for sensitivity and specificity was 0.75. The FEV1/FEV6 ratio can be considered to be a good alternative to the FEV1/FVC ratio for the diagnosis of airway obstruction, both using a fixed cut-off point or below the LLN as reference. The FEV1/FEV6 ratio has the additional advantage of being an easier maneuver for the subjects and for the lung function technicians, providing a higher reproducibility than traditional spirometry maneuvers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiopulmonary exercise testing (CPET) plays an important role in the assessment of functional capacity in patients with interstitial lung disease. The aim of this study was to identify CPET measures that might be helpful in predicting the vital capacity and diffusion capacity outcomes of patients with thoracic sarcoidosis. A longitudinal study was conducted on 42 nonsmoking patients with thoracic sarcoidosis (median age = 46.5 years, 22 females). At the first evaluation, spirometry, the measurement of single-breath carbon monoxide diffusing capacity (D LCOsb) and CPET were performed. Five years later, the patients underwent a second evaluation consisting of spirometry and D LCOsb measurement. After 5 years, forced vital capacity (FVC)% and D LCOsb% had decreased significantly [95.5 (82-105) vs 87.5 (58-103) and 93.5 (79-103) vs 84.5 (44-102), respectively; P < 0.0001 for both]. In CPET, the peak oxygen uptake, maximum respiratory rate, breathing reserve, alveolar-arterial oxygen pressure gradient at peak exercise (P(A-a)O2), and Δ SpO2 values showed a strong correlation with the relative differences for FVC% and D LCOsb% (P < 0.0001 for all). P(A-a)O2 ≥22 mmHg and breathing reserve ≤40% were identified as significant independent variables for the decline in pulmonary function. Patients with thoracic sarcoidosis showed a significant reduction in FVC% and D LCOsb% after 5 years of follow-up. These data show that the outcome measures of CPET are predictors of the decline of pulmonary function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Few studies evaluate the amount of particulate matter less than 2.5 mm in diameter (PM2.5) in relation to a change in lung function among adults in a population. The aim of this study was to assess the association of coal as a domestic energy source to pulmonary function in an adult population in inner-city areas of Zunyi city in China where coal use is common. In a cross-sectional study of 104 households, pulmonary function measurements were assessed and compared in 110 coal users and 121 non-coal users (≥18 years old) who were all nonsmokers. Several sociodemographic factors were assessed by questionnaire, and ventilatory function measurements including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), the FEV1/FVC ratio, and peak expiratory flow rate (PEFR) were compared between the 2 groups. The amount of PM2.5 was also measured in all residences. There was a significant increase in the relative concentration of PM2.5 in the indoor kitchens and living rooms of the coal-exposed group compared to the non-coal-exposed group. In multivariate analysis, current exposure to coal smoke was associated with a 31.7% decrease in FVC, a 42.0% decrease in FEV1, a 7.46% decrease in the FEV1/FVC ratio, and a 23.1% decrease in PEFR in adult residents. The slope of lung function decrease for Chinese adults is approximately a 2-L decrease in FVC, a 3-L decrease in FEV1, and an 8 L/s decrease in PEFR per count per minute of PM2.5 exposure. These results demonstrate the harmful effects of indoor air pollution from coal smoke on the lung function of adult residents and emphasize the need for public health efforts to decrease exposure to coal smoke.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The autonomic nervous system maintains homeostasis, which is the state of balance in the body. That balance can be determined simply and noninvasively by evaluating heart rate variability (HRV). However, independently of autonomic control of the heart, HRV can be influenced by other factors, such as respiratory parameters. Little is known about the relationship between HRV and spirometric indices. In this study, our objective was to determine whether HRV correlates with spirometric indices in adults without cardiopulmonary disease, considering the main confounders (e.g., smoking and physical inactivity). In a sample of 119 asymptomatic adults (age 20-80 years), we evaluated forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1). We evaluated resting HRV indices within a 5-min window in the middle of a 10-min recording period, thereafter analyzing time and frequency domains. To evaluate daily physical activity, we instructed participants to use a triaxial accelerometer for 7 days. Physical inactivity was defined as <150 min/week of moderate to intense physical activity. We found that FVC and FEV1, respectively, correlated significantly with the following aspects of the RR interval: standard deviation of the RR intervals (r =0.31 and 0.35), low-frequency component (r =0.38 and 0.40), and Poincaré plot SD2 (r =0.34 and 0.36). Multivariate regression analysis, adjusted for age, sex, smoking, physical inactivity, and cardiovascular risk, identified the SD2 and dyslipidemia as independent predictors of FVC and FEV1 (R2=0.125 and 0.180, respectively, for both). We conclude that pulmonary function is influenced by autonomic control of cardiovascular function, independently of the main confounders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comparar la función pulmonar de pacientes con diabetes mellitus tipo 2 reciente, con diabetes mellitus tipo 2 de mayor evolución. Luego de ajustar por variables determinantes de la función pulmonar. Estudio observacional analítico de corte transversal. Obtención de variables espirométricas, como lo son el Volumen Espiratorio Forzado del primer segundo [VEF1], Relación entre el VEF1 y la Capacidad vital forzada, (VEF1/CVF), y residuales de Volumen Espiratorio Forzado del primer segundo (rVEF1) y de la Capacidad vital forzada y (rCVF). 495 pacientes diabéticos que consultaron a la Asociación Colombiana de Diabetes (ACD), entre julio 2005 y septiembre de 2007. Análisis entre duración de la diabetes (años), y el deterioro en la función pulmonar (variables espirométricas). Los pacientes con duración mayor de 8 años de la diabetes, tuvieron menor VEF1 comparado con los pacientes con duración menor de 8 años (2,62lts y 2,78lts, P 0.0139), así como de CVF (3.3lts y 3.5lts, P 0.0164). Después de ajustar por determinantes conocidos de la función pulmonar (sexo, edad, talla, tabaquismo, exposición a humo de leña), y por control de la diabetes (HbA1c) y tratamiento hipoglucemiante, estas diferencias persistieron; Los pacientes con duración mayor de 8 años de diabetes, tuvieron mayores residuales de VEF1 en promedio (rVEF1 -176,6mL y -115.7mL, con una diferencia de 60.8ml P<0.0001), así como de residuales de CVF (rCVF-261.9mL, y 160.5mL,con una diferencia de 100,4ml P<0.0001). Este estudio sustenta las observaciones clínicas que la duración de la diabetes es factor de riesgo independiente para deterioro de la función pulmonar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Assess the effect of re-expansive respiratory patterns associated to respiratory biofeedback (RBF) on pulmonary function, respiratory muscle strength and habits in individuals with functional mouth breathing (FMB).Methods: Sixty children with FMB were divided into experimental and control groups. The experimental group was submitted to 15 sessions of re-expansive respiratory patterns associated to RBF (biofeedback pletsmovent; MICROHARD (R) V1.0), which provided biofeedback of the thoracic and abdominal movements. The control group was submitted to 15 sessions using biofeedback alone. Spirometry, maximum static respiratory pressure measurements and questions regarding habits (answered by parents/guardians) were carried out before and after therapy. The Student's t-test for paired data and non-parametric tests were employed for statistical analysis at a 5% Level of significance.Results: Significant changes were found in forced vital. capacity, Tiffeneau index scores, maximum expiratory pressure, maximum inspiratory pressure and habits assessed in FMB with the use of RBF associated to the re-expansive patterns. No significant differences were found comparing the experimental and control groups.Conclusions: The results allow the conclusion that RBF associated to re-expansive patterns improves forced vital capacity, Tiffeneau index scores, respiratory muscle strength and habits in FMB and can therefore be used as a form of therapy for such individuals. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In asthmatic, the lung hyperinflation leaves the inspiratory muscle at a suboptimal position in length-tension relationship, reducing the capacity of to generate tension. The increase in transversal section area of the inspiratory muscles could reverse or delay the deterioration of inspiratory muscle function. Objective: To evaluate the evidence for the efficacy of inspiratory muscle training (IMT) with an external resistive device in patients with asthma. Methods: A systematic review with meta-analysis was carried out. The sources researched were the Cochrane Airways Group Specialised Register of trials, Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 11 of 12, 2012), MEDLINE, EMBASE, PsycINFO, CINAHL, AMED, ClinicalTrials.gov and reference lists of articles. All databases were searched from their inception up to November 2012 and there was no restriction on the language of publication. Randomised controlled trials that involved the use of an external inspiratory muscle training device versus a control (sham or no inspiratory training device) were considered for inclusion. Two reviewers independently selected articles for inclusion, evaluated risk of bias in studies and extracted data. Results: A total of five studies involving 113 asthmatic patients were included. Three clinical trials were produced by the same group. The included studies showed a significant increase in maximal inspiratory pressure (MD 13.34 cmH2O, 95% CI 4.70 to 21.98), although the confidence intervals were wide. There was no statistically significant difference between the IMT group and the control group for maximal expiratory pressure, peak expiratory flow rate, forced expiratory volume in one second, forced vital capacity, sensation of dyspnea and use of beta2-agonist. There were no studies describing exacerbation events that required a course of oral and inhaled corticosteroids or emergency department visits, inspiratory muscle endurance, hospital admissions and days of work or school. Conclusions: There is no conclusive evidence in this review to support or refute inspiratory muscle training for asthma, once the evidence was limited by the small number of studies included, number of participants in them together with the risk of bias. More well conducted randomized controlled trials are needed, such trials should investigate respiratory muscle strength, exacerbation rate, lung function, symptoms, hospital admissions, use of medications and days off work or school. IMT should also be assessed in the context of more severe asthma

Relevância:

100.00% 100.00%

Publicador:

Resumo:

obesity affects rightly functional capacity diminishing the cardiovascular system efficiency and oxygen uptake (VO2). Field tests, such as, Incremental Shuttle Walking Test (ISWT) and Six Minute Walk Test (6MWT) has been employed as alternative of Cardiopulmonary Exercise Test (CPX), to functional assessing for conditions which transport of oxygen to peripheral is diminished. Nevertheless, the knowing about metabolic variables response in real time and it comparing among different maximal and submaximal tests in obese is absent. Aim: to compare cardiopulmonary, metabolic response during CPX, ISWT and 6MWT and to analyse it influence of adiposity markers in obese. Material e Method: crosssectional, prospective study. Obese included if: (BMI>30Kg/m2; FVC>80%), were assessed as clinical, anthropometric (BMI, body adiposity index-BAI, waist-WC, hip- HC and neck-NC circumferences) and spirometry (forced vital capacity-FVC, Forced expiratory volume-1°second-FEV1, maximal voluntary ventilation-MVV) variables. Obese performed the sequence of tests: CPX, ISWT and 6MWT. Throughout tests was assessed breath-by-breath by telemetry system (Cortex-Biophysik-Metamax3B) variables; oxygen uptake on peak of activity (VO2peak); carbon dioxide production (VCO2); Volume Expiratory (VE); ventilatory equivalents for VO2 (VE/VO2) and CO2 (VE/VCO2); respiratory exchange rate (RER) and perceived effort-Borg6-20). Results: 15 obese (10women) 39.4+10.1years, normal spirometry (%CVF=93.7+9.7) finished all test. They have BMI (43.5+6.6kg/m2) and different as %adiposity (BAI=50.0+10.5% and 48.8+16.9% respectively women and men). Difference of VO2ml/kg/min and %VO2 were finding between CPX (18.6+4.0) and 6MWT (13.2+2.5) but not between ISWT (15.4+2.9). Agreement was found for ISWT and CPX on VO2Peak (3.2ml/kg/min; 95%; IC-3.0 9.4) and %VO2 (16.4%). VCO2(l/min) confirms similarity in production for CPX (2.3+1.0) and ISWT (1.7+0.7) and difference for 6MWT (1.4+0.6). WC explains more the response of CPX and ISWT than other adiposity markers. Adiposity diminishes 3.2% duration of CPX. Conclusion: ISWT promotes similar metabolic and cardiovascular response than CPX in obese. It suggesting that ISWT could be useful and reliable to assess oxygen uptake and functional capacity in obese

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito da utilização de um programa de treinamento específico dos músculos respiratórios sobre a função pulmonar em indivíduos tabagistas. MÉTODOS: Foram estudados 50 indivíduos tabagistas assintomáticos com idade superior a 30 anos, nos seguintes momentos: A0 - avaliação inicial seguida do protocolo de exercícios respiratórios; A1 - reavaliação após 10 minutos da aplicação do protocolo; e A2 -reavaliação final após duas semanas de treinamento utilizando o mesmo protocolo três vezes por semana. A avaliação foi realizada através das medidas de pressões respiratórias máximas (PImax. e PEmax.), picos de fluxo respiratórios (PFI e PFE), ventilação voluntária máxima (VVM), capacidade vital Forçada (CVF) e Volume expiratório forçado no primeiro segundo (VEF1). RESULTADOS: Não houve melhora na CVF e VEF1 da avaliação inicial para a final. Houve aumento significativo das variáveis PFI, PFE, VVM e PImax nas avaliações A1 e A2. A variável PEmax. aumentou somente na avaliação A2. CONCLUSÃO: A aplicação de protocolo de exercícios respiratórios com e sem carga adicional em indivíduos tabagistas produziu melhora imediata na performance dos músculos respiratórios, mas esta melhora foi mais acentuada após duas semanas de exercício.