970 resultados para Flow-Control
Resumo:
The performance of supersonic engine inlets and external aerodynamic surfaces can be critically affected by shock wave / boundary layer interactions (SBLIs), whose severe adverse pressure gradients can cause boundary layer separation. Currently such problems are avoided primarily through the use of boundary layer bleed/suction which can be a source of significant performance degradation. This study investigates a novel type of flow control device called micro-vortex generators (µVGs) which may offer similar control benefits without the bleed penalties. µVGs have the ability to alter the near-wall structure of compressible turbulent boundary layers to provide increased mixing of high speed fluid which improves the boundary layer health when subjected to flow disturbance. Due to their small size,µVGs are embedded in the boundary layer which provide reduced drag compared to the traditional vortex generators while they are cost-effective, physically robust and do not require a power source. To examine the potential of µVGs, a detailed experimental and computational study of micro-ramps in a supersonic boundary layer at Mach 3 subjected to an oblique shock was undertaken. The experiments employed a flat plate boundary layer with an impinging oblique shock with downstream total pressure measurements. The moderate Reynolds number of 3,800 based on displacement thickness allowed the computations to use Large Eddy Simulations without the subgrid stress model (LES-nSGS). The LES predictions indicated that the shock changes the structure of the turbulent eddies and the primary vortices generated from the micro-ramp. Furthermore, they generally reproduced the experimentally obtained mean velocity profiles, unlike similarly-resolved RANS computations. The experiments and the LES results indicate that the micro-ramps, whose height is h≈0.5δ, can significantly reduce boundary layer thickness and improve downstream boundary layer health as measured by the incompressible shape factor, H. Regions directly behind the ramp centerline tended to have increased boundary layer thickness indicating the significant three-dimensionality of the flow field. Compared to baseline sizes, smaller micro-ramps yielded improved total pressure recovery. Moving the smaller ramps closer to the shock interaction also reduced the displacement thickness and the separated area. This effect is attributed to decreased wave drag and the closer proximity of the vortex pairs to the wall. In the second part of the study, various types of µVGs are investigated including micro-ramps and micro-vanes. The results showed that vortices generated from µVGs can partially eliminate shock induced flow separation and can continue to entrain high momentum flux for boundary layer recovery downstream. The micro-ramps resulted in thinner downstream displacement thickness in comparison to the micro-vanes. However, the strength of the streamwise vorticity for the micro-ramps decayed faster due to dissipation especially after the shock interaction. In addition, the close spanwise distance between each vortex for the ramp geometry causes the vortex cores to move upwards from the wall due to induced upwash effects. Micro-vanes, on the other hand, yielded an increased spanwise spacing of the streamwise vortices at the point of formation. This resulted in streamwise vortices staying closer to the wall with less circulation decay, and the reduction in overall flow separation is attributed to these effects. Two hybrid concepts, named “thick-vane” and “split-ramp”, were also studied where the former is a vane with side supports and the latter has a uniform spacing along the centerline of the baseline ramp. These geometries behaved similar to the micro-vanes in terms of the streamwise vorticity and the ability to reduce flow separation, but are more physically robust than the thin vanes. Next, Mach number effect on flow past the micro-ramps (h~0.5δ) are examined in a supersonic boundary layer at M=1.4, 2.2 and 3.0, but with no shock waves present. The LES results indicate that micro-ramps have a greater impact at lower Mach number near the device but its influence decays faster than that for the higher Mach number cases. This may be due to the additional dissipation caused by the primary vortices with smaller effective diameter at the lower Mach number such that their coherency is easily lost causing the streamwise vorticity and the turbulent kinetic energy to decay quickly. The normal distance between the vortex core and the wall had similar growth indicating weak correlation with the Mach number; however, the spanwise distance between the two counter-rotating cores further increases with lower Mach number. Finally, various µVGs which include micro-ramp, split-ramp and a new hybrid concept “ramped-vane” are investigated under normal shock conditions at Mach number of 1.3. In particular, the ramped-vane was studied extensively by varying its size, interior spacing of the device and streamwise position respect to the shock. The ramped-vane provided increased vorticity compared to the micro-ramp and the split-ramp. This significantly reduced the separation length downstream of the device centerline where a larger ramped-vane with increased trailing edge gap yielded a fully attached flow at the centerline of separation region. The results from coarse-resolution LES studies show that the larger ramped-vane provided the most reductions in the turbulent kinetic energy and pressure fluctuation compared to other devices downstream of the shock. Additional benefits include negligible drag while the reductions in displacement thickness and shape factor were seen compared to other devices. Increased wall shear stress and pressure recovery were found with the larger ramped-vane in the baseline resolution LES studies which also gave decreased amplitudes of the pressure fluctuations downstream of the shock.
Resumo:
A new, simple approach for modeling and assessing the operation and response of the multiline voltage-source controller (VSC)-based flexible ac transmission system controllers, namely the generalized interline power-flow controller (GIPFC) and the interline power-flow controller (IPFC), is presented in this paper. The model and the analysis developed are based on the converters` power balance method which makes use of the d-q orthogonal coordinates to thereafter present a direct solution for these controllers through a quadratic equation. The main constraints and limitations that such devices present while controlling the two independent ac systems considered, will also be evaluated. In order to examine and validate the steady-state model initially proposed, a phase-shift VSC-based GIPFC was also built in the Alternate Transients Program program whose results are also included in this paper. Where applicable, a comparative evaluation between the GIPFC and the IPFC is also presented.
Resumo:
O desenvolvimento actual de aplicações paralelas com processamento intensivo (HPC - High Performance Computing) para alojamento em computadores organizados em Cluster baseia-se muito no modelo de passagem de mensagens, do qual é de realçar os esforços de definição de standards, por exemplo, MPI - Message - Passing Interface. Por outro lado, com a generalização do paradigma de programação orientado aos objectos para ambientes distribuídos (Java RMI, .NET Remoting), existe a possibilidade de considerar que a execução de uma aplicação, de processamento paralelo e intensivo, pode ser decomposta em vários fluxos de execução paralela, em que cada fluxo é constituído por uma ou mais tarefas executadas no contexto de objectos distribuídos. Normalmente, em ambientes baseados em objectos distribuídos, a especificação, controlo e sincronização dos vários fluxos de execução paralela, é realizada de forma explicita e codificada num programa principal (hard-coded), dificultando possíveis e necessárias modificações posteriores. No entanto, existem, neste contexto, trabalhos que propõem uma abordagem de decomposição, seguindo o paradigma de workflow com interacções entre as tarefas por, entre outras, data-flow, control-flow, finite - state - machine. Este trabalho consistiu em propor e explorar um modelo de execução, sincronização e controlo de múltiplas tarefas, que permita de forma flexível desenhar aplicações de processamento intensivo, tirando partido da execução paralela de tarefas em diferentes máquinas. O modelo proposto e consequente implementação, num protótipo experimental, permite: especificar aplicações usando fluxos de execução; submeter fluxos para execução e controlar e monitorizar a execução desses fluxos. As tarefas envolvidas nos fluxos de execução podem executar-se num conjunto de recursos distribuídos. As principais características a realçar no modelo proposto, são a expansibilidade e o desacoplamento entre as diferentes componentes envolvidas na execução dos fluxos de execução. São ainda descritos casos de teste que permitiram validar o modelo e o protótipo implementado. Tendo consciência da necessidade de continuar no futuro esta linha de investigação, este trabalho é um contributo para demonstrar que o paradigma de workflow é adequado para expressar e executar, de forma paralela e distribuída, aplicações complexas de processamento intensivo.
Resumo:
This paper proposes the use of a Modular Marx Multilevel Converter, as a solution for energy integration between an offshore Wind Farm and the power grid network. The Marx modular multilevel converter is based on the Marx generator, and solves two typical problems in this type of multilevel topologies: modularity and dc capacitor voltage balancing. This paper details the strategy for dc capacitor voltage equalization. The dynamic models of the converter and power grid are presented in order to design the converter ac output voltages and the dc capacitor voltage controller. The average current control is presented and used for power flow control, harmonics and reactive power compensation. Simulation results are presented in order to show the effectiveness of the proposed (MC)-C-3 topology.
Resumo:
Broadcast networks that are characterised by having different physical layers (PhL) demand some kind of traffic adaptation between segments, in order to avoid traffic congestion in linking devices. In many LANs, this problem is solved by the actual linking devices, which use some kind of flow control mechanism that either tell transmitting stations to pause (the transmission) or just discard frames. In this paper, we address the case of token-passing fieldbus networks operating in a broadcast fashion and involving message transactions over heterogeneous (wired or wireless) physical layers. For the addressed case, real-time and reliability requirements demand a different solution to the traffic adaptation problem. Our approach relies on the insertion of an appropriate idle time before a station issuing a request frame. In this way, we guarantee that the linking devices’ queues do not increase in a way that the timeliness properties of the overall system turn out to be unsuitable for the targeted applications.
Resumo:
IEEE International Conference on Cyber Physical Systems, Networks and Applications (CPSNA'15), Hong Kong, China.
Resumo:
RESUMO: Na descrição deste estudo foi utilizada a terminologia anatómica da Sociedade Brasileira de Anatomia adaptada ao português por J. A. Esperança-Pina de acordo com o tratado Anatomia Humana da Relação. Os actuais estudos sobre hipoacusia sensorioneural implicam um grupo crescente de situações, em que a lesão se situa ao nível da microvascularização coclear, daí que o conhecimento exacto da angiomorfologia normal se torne essencial na fase actual do conhecimento. A autora tem vindo a estudar, desde 1986, a angiomorfologia do ouvido Interno no modelo experimental, o Cobaio, utilizando várias técnicas microvasculares. sendo dado enfâse particular neste estudo à técnica de microscopia electrónica de varrimento em moldes vasculares. Os animais usados no presente estudo pertencem à espécie cavia porcellus, cobaio, por serem considerados na comunidade cientifica internacional como o melhor modelo experimental para estudo do ouvido interno, pelo facto de a morfologia coclear ser muito semelhante à do Homem e por isso ser um modelo fiável para cirurgia experimental e microdissecção. Este estudo foi realizado em 100 cobaios, cavia porcellus, de ambos os sexos com peso médio de 450g. A vascularização do ouvido interno, no cobaio como no homem, faz-se através dos ramos de divisão da artéria auditiva interna ou labiríntica. A artéria labiríntica origina-se como ramo colateral da artéria cerebelosa ântero-inferior a qual tem origem na artéria basilar ou na artéria vertebral. Embora no homem a artéria auditiva interna possa também destacar-se da artéria basilar e até da artéria vertebral, no cobaio em todos os casos estudados a sua origem verificou-se sempre na artéria cerebelosa ântero-inferior. A artéria labiríntica, ao passar abaixo do meato auditivo interno, divide-se na artéria vestibular anterior e na artéria coclear comum.A artéria vestibular anterior dirige-se para o nervo vestibular, emite vasa nervorum para este nervo e vasculariza o utrículo e os canais semicirculares. A artéria coclear comum origina dois ramos principais, a artéria vestíbulo‑coclear ou vestibular posterior no cobaio, a qual se destaca junto à espira basal da cóclea e a artéria coclear, como ramo terminal, que passa a denominar-se de artéria modiolar ou espiralada, após entrar no modíolo. A artéria modiolar ascende no modíolo promovendo através dos seus ramos colaterais e dos seus ramos terminais a microvascularização coclear, numa vascularização de órgão de tipo terminal. Ao longo do seu trajecto verificou‑se de modo constante uma redução gradual de calibre em cada uma das espiras, por emissão de ramos colaterais, sendo que o calibre da artéria na base da cóclea apresenta um valor que diminui gradualmente até ao ápice. A artéria modiolar origina em todo o seu trajecto ramos colaterais, cujo número diminui em valor absoluto da base para o ápice: Arteríolas radiárias internas, arteríolas de trajecto flexuoso que caminham junto às estruturas sensorioneurais da parede interna da cóclea, junto ao lábio timpânico da lâmina espiral óssea e na parede do próprio modíolo, que se relacionam intimamente com este. As arteríolas radiárias internas originam‑se no flanco da artéria modiolar espiralada. Contam‑se dez a doze em cada espira, extraordinariamente flexuosas desde a sua origem. As arteríolas radiárias internas originam como ramos colaterais, vários grupos de arteríolas de menor calibre, que vascularizam distintas regiões da parede interna da cóclea, as arteríolas do gânglio espiral, a rede espiral interna, as arteríolas de origem dos glomérulos de Schwalbe e a arteríola da lâmina basilar. As arteríolas radiárias externas importantes ramos colaterais da artéria modiolar espiralada promovem a vascularização de importantes estruturas da parede externa. Ao atingir o limite externo do ligamento espiral, as arteríolas radiárias externas dividem‑se em vários ramos arteriolares de menor calibre, ao longo da convexidade do limite externo do ligamento espiral, originando a rede capilar pós-estriada que ocupa a porção lateral do ligamento espiral e a rede capilar ad‑ -estriada, na sua porção mais medial em íntima relação com a estria vascular. A espira basal da cóclea apresenta grande riqueza de vascularização, com características particulares apenas a esta espira, a qual é metabolicamente a mais exigente. A arteríola da janela da cóclea aborda a janela da cóclea pela sua convexidade e divide-se numa rica rede vascular da qual emergem arteríolas pré-capilares que se ramificam em capilares, os quais se dirigem em profundidade penetrando a rampa timpânica da cóclea ao nível da espira basal. Importou neste estudo verificar quais as semelhanças em termos de calibre de estruturas análogas, na parede interna e na parede externa da cóclea, com particular incidência na rede capilar. Do estudo estatístico realizado com testes paramétricos de Tamahane e não paramétricos de Mann-Whitney, verifica-se que comparando todas as estruturas consideradas estas têm calibres diferentes, com excepção dos capilares da estria vascular e do ligamento espiral, pertencentes à parede externa da cóclea que têm calibres iguais aos capilares da rede espiral interna e aos capilares da parede interna da cóclea, dependentes das arteríolas da rede espiral interna. As redes capilares dependentes das arteríolas radiárias internas que vascularizam as estruturas sensorioneurais junto á parede interna do modiolo são em tudo semelhantes em termos de calibre às redes capilares da parede externa da cóclea, incluindo os capilares da estria vascular. Esta particularidade traduz num órgão com vascularização de tipo terminal,um mecanismo de controlo do fluxo sanguíneo coclear tão importante na parede interna como na parede externa da cóclea. ------------ ABSTRACT:Current studies on sensorineural hearing loss, imply a growing group of situations in which the lesion is located at the level of the cochlear microvasculature, hence the exact knowledge of normal angiomorfology becomes essential in current state of knowledge. The author has been studying since 1986, the angiomorfology of inner on the experimental model, the guinea pig, using various microvascular techniques being given particular emphasis in this study to the results of the technique of scanning electron microscopy on corrosion casts. The animals used in this study belong to the species cavia porcellus, guinea pig, to be considered in the international scientific community as the best experimental model for the study of the inner ear, the cochlear morphology is very similar to human and therefore a reliable model for experimental surgery and microdissection. This study was performed in 100 guinea pigs of both sexes with average weight of 450g. There shall be a brief description of embryology, anatomy and cochlear physiology in the light of developmental biology, regarding also the spatial location of the cochlea and the determinism of morphogenetic fields in their development and function. The cochlear transduction mechanism converts the sound wave in stimuli sound and so afferent auditory nerve fibres and deafness are closely related to the cochlear microvasculature. Cochlear ischemia is accompanied by immediate hearing loss. The different type of cochlear injury that leads to sensorineural deafness is well studied in presbycusis where an objective link with the audiometric pattern as been established. The sensory type of deafness, is closely related to the degeneracy of the organ of Corti and damage to the outer hair cells at the basal turn of the cochlea. Keeping in mind cochlear tonotopy with location of high frequency sounds at the level of the base of the cochlea, it explains the audiometric pattern with loss in high frequencies. The neural type of deafness, is characterized by neuronal loss with loss of descendant important neuronal afferents, with audiometric translation on a gradually curve with important loss of auditory discrimination. The metabolic type of deafness results in atrophy of the vascular stria, with consequent change in the potential of the endolymph by decreasing the vascular stria cells and changes in K + recycling mechanism. There is also a change in the morphology of the spiral ligament and the audiometric patern as a flattened curve with loss at all frequencies. Bearing in mind cochlear tonotopy and being characterized all types of sensorineural deafness, we may inquire to what extent the cochlear microvasculature, considering not only the cochlea as a whole but different regions of the inner wall and the outer wall of the cochlea, contributes to deafness. We analysed the entire cochlear morphology on scanning electron microscopy with particular emphasis on bone and membranous cochlea. The inner wall of the cochlea and intramodiolar structures such as the spiral ganglion, the morphology of its cell bodies and their axons are analyzed. The morphology of Corti’s organ is described in detail, with description and large detail of the inner and outer hair cells. Is then presented the study of the microvasculature itself. The spiral modiolar artery is observed with the diaphanization technique and the technique of scanning electron microscopy on corrosion vascular casts. After emergence of collateral branches of the greatest importance, the radiating internal and external arterioles, the modiolar artery gives rise to its terminal branches, the arterioles of the cochear apex. Arterial vasa vasorum and vasa nervorum are displayed with a great detail, which was not yet described in such detail in previous microvascular studies. The arterial radiating arterioles originate in the flank of the spiral modiolar artery in number of ten to twelve in each loop, and they vascularize through their branches the inner wall cochlear sensorineural structures located in the modiolus as the spiral ganglion and structures near the organ of Corti. Their caliber is above 20 μm on the basal turn and in the second loop it decreases to values between 12 and 20 μm, decreasing progressively to the apex of the cochlea.They arise near the modiolus or on their way in the spiral lamina forming vascular loops, and divide without presenting vascular constrictions in their divisions, originating new vascular loops of lower caliber. Internal ratiating arterioles originate as collateral branches several groups of smaller caliber arterioles, which vascularize distinct regions of the inner wall of the cochlea namely, the arterioles of the spiral ganglion, the internal spiral network, the arterioles of origin of the glomeruli of Schwalbe and the arterioles of the basilar membrane. The glomeruli of Schwalbe play an important functional role as relay-stations, in hemodynamic terms, to control the cochlear microvasculature. External radiating arterioles have their origin in the spiral modiolar artery, they are directed towards the outer wall of the cochlea and run through the roof of the scala vestibuli. Above the insertion of Reissner’s membrane on the external wall the external radiating arterioles originate the spiral ligament arterioles, which vascularize the spiral ligament, they divide into several arteriolar branches of smaller caliber, along the convexity of the outer edge of the spiral ligament. The connective tissue of the spiral ligament forms a mesh with supporting function of the highly specialized epithelium, where pericytes were identifiable. Next to its base there is the microvascular network of stria vascularis. The adstriated vascular network which is divided into a capillary network, the capillary network of stria vascularis. The stria vascularis, the only vascularized epithelium of the human body, plays an important role, forming an haemato-labyrintine barrier to assure labyrinthine endocochlear potential and transport of ions, essential for the mechanism of transduction of external hair cells. The cochlear basal turn has a special feature on its external wall, the region of the windows, the round windows giving access to scala tympani and the oval window thatleads into scala vestibuli, and so it is metabolic demanding. For their role in cochlear tonotopy the sensorineural structures and those of the external wall of the cochlea, are particularly vulnerable to hypoxia. Although the complementarity of all the techniques was important for three- -dimensional reconstruction of the microvasculature of the cochlea, the scanning electron microscopy technique, especially when we used the system Semafore was fundamental to perform precise morphometric mesures regarding all vascular structures.Regarding the capillaries of the inner and outer wall of the cochlea networks this technique allowed their characterization in morphometric terms. To conclude the capillaries of the inner wall and of the external wall of the cochlea have similar size. So although located at different cochlear regions, with a different functional role, in cochlear physiology these networks consist of capillaries of similar caliber. It seems to translate a cochlear blood flow control mechanism that is so important in the inner wall as in and the external wall of the cochlea to provide for in inner ear homeosthasia.
Resumo:
Doctoral Program in Computer Science
Resumo:
This thesis analyses the calculation of FanSave and PumpSave energy saving tools calculation. With these programs energy consumption of variable speed drive control for fans and pumps can be compared to other control methods. With FanSave centrifugal and axial fans can be examined and PumpSave deals with centrifugal pumps. By means of these programs also suitable frequency converter can be chosen from the ABB collection. Programs need as initial values information about the appliances like amount of flow and efficiencies. Operation time is important factor when calculating the annual energy consumption and information about it are the length and profile. Basic theory related to fans and pumps is introduced without more precise instructions for dimensioning. FanSave and PumpSave contain various methods for flow control. These control methods are introduced in the thesis based on their operational principles and suitability. Also squirrel cage motor and frequency converter are introduced because of their close involvement to fans and pumps. Second part of the thesis contains comparison between results of FanSave’s and PumpSave’s calculation and performance curve based calculation. Also laboratory tests were made with centrifugal and axial fan and also with centrifugal pump. With the results from this thesis the calculation of these programs can be adjusted to be more accurate and also some new features can be added.
Resumo:
Tämä diplomityö on selvitystyö mittakuvien ja kolmiulotteisten CAD-mallien tuottamisesta. Mittakuvat ja 3D-CAD-mallit halutaan Neles-tuotemerkin omaaville tuotteille. Olennaisena osana työssä on tuotetiedonhallintajärjestelmä AtonPDM, koska mittakuvia ja malleja toivottaisiin hallittavan AtonPDM-järjestelmällä. Työ tehdään Metso Automationin (MA) Flow Control (FC) –liiketoimintalinjalle. Nykyiset mittakuvat aiheuttavat ongelmia sekä MA:ssa että asiakkaille. MA:ssa mittakuvien tekeminen kestää kauemmin kuin asiakas toivoisi. Nykyisen mittakuvaohjelmiston riittämättömät ominaisuudet aiheuttavat lisätyötä mittakuvien valmistuksessa. Asiakkaille mittakuvien viivästyminen on suunnittelua hidastava tekijä. Mittakuvissa olevat virheet ja puutteet vaikeuttavat asiakkaan suunnittelutyötä ja saattavat päästä läpi tarkatuksien myös loppusuunnitelmiin, jolloin seurauksena voi olla rahallisia menetyksiä. Tämän päivän putkistosuunnittelu hoidetaan suurimmaksi osaksi 3D-CADohjelmistoilla. Suunnittelua helpotetaan ja nopeutetaan valmiilla komponenttien 3Dmalleilla, joihin on liitetty tuotetietoa. Työssä on haastateltu MA:n henkilökuntaa, CAD-järjestelmien toimittajia ja asiakkaita. Haastattelut ovat työn tärkein tiedonlähde. Teoriatietoa on selvitetty kirjoista, lehdistä ja internetistä. Teoriaosiossa käydään läpi tuotetiedonhallinta (Product Data Management, PDM), tietokanta ja parametrinen mallintaminen. Työn lopputuloksena on pyritty saamaan kuvaus siitä miten tuotetaan 3D-CAD-mallit ja mittakuvat Neles-tuotteista käyttäen tiedonlähteenä AtonPDM:ää ja millaisia 3Dmallien ja mittakuvien tulee olla. Malleja ja mittakuvia tuottavaan järjestelmään on etsitty ratkaisuja CAD-ohjelmistoista. Ratkaisuja on verrattu keskenään ominaisuuksien, joustavuuden ja AtonPDM yhteensopivuuden perusteella.
Resumo:
This note has as objective to present the advantages of the use of syringe-type pumps for the feeding of liquid reactants, together with mass flow controllers for gases, instead of the saturators, as it is generally accomplished. Among the advantages, the system with syringe pumps presents a greater flexibility in flow control as well as in composition compared with the system that uses saturator. In addition, the flow of the liquid reactants is known with precision in the syringe pump system.
Resumo:
The main purpose of this thesis is to measure and evaluate how accurately the current energy saving calculation in ABB’s new variable speed drive ACS850 works. The main topic of this thesis is energy-efficiency parameters. At the beginning of this thesis centrifugal pump, squirrel cage motor and variable speed drive, including some equations related to them, are being introduced. Also methods of throttling control and variable speed drive control of centrifugal pumps are being introduced. These subjects are introduced because the energy saving calculation in ACS850 is related to the centrifugal pumps usually driven by squirrel cage motors. The theory also includes short section about specific energy of pumping. Before measurements the current energy saving calculation of ACS850 is being introduced and analyzed. The measurements part includes introduction of measuring equipment, measurement results, summary and analysis of the measurements. At the end of this thesis a proposal for an improvement to the current energy saving calculation is being introduced and few proposals are made for new energy-efficiency parameters, which could be added to variable speed drives. At the end are also thoughts
Resumo:
Technology scaling has proceeded into dimensions in which the reliability of manufactured devices is becoming endangered. The reliability decrease is a consequence of physical limitations, relative increase of variations, and decreasing noise margins, among others. A promising solution for bringing the reliability of circuits back to a desired level is the use of design methods which introduce tolerance against possible faults in an integrated circuit. This thesis studies and presents fault tolerance methods for network-onchip (NoC) which is a design paradigm targeted for very large systems-onchip. In a NoC resources, such as processors and memories, are connected to a communication network; comparable to the Internet. Fault tolerance in such a system can be achieved at many abstraction levels. The thesis studies the origin of faults in modern technologies and explains the classification to transient, intermittent and permanent faults. A survey of fault tolerance methods is presented to demonstrate the diversity of available methods. Networks-on-chip are approached by exploring their main design choices: the selection of a topology, routing protocol, and flow control method. Fault tolerance methods for NoCs are studied at different layers of the OSI reference model. The data link layer provides a reliable communication link over a physical channel. Error control coding is an efficient fault tolerance method especially against transient faults at this abstraction level. Error control coding methods suitable for on-chip communication are studied and their implementations presented. Error control coding loses its effectiveness in the presence of intermittent and permanent faults. Therefore, other solutions against them are presented. The introduction of spare wires and split transmissions are shown to provide good tolerance against intermittent and permanent errors and their combination to error control coding is illustrated. At the network layer positioned above the data link layer, fault tolerance can be achieved with the design of fault tolerant network topologies and routing algorithms. Both of these approaches are presented in the thesis together with realizations in the both categories. The thesis concludes that an optimal fault tolerance solution contains carefully co-designed elements from different abstraction levels
Resumo:
In the current economy situation companies try to reduce their expenses. One of the solutions is to improve the energy efficiency of the processes. It is known that the energy consumption of pumping applications range from 20 up to 50% of the energy usage in the certain industrial plants operations. Some studies have shown that 30% to 50% of energy consumed by pump systems could be saved by changing the pump or the flow control method. The aim of this thesis is to create a mobile measurement system that can calculate a working point position of a pump drive. This information can be used to determine the efficiency of the pump drive operation and to develop a solution to bring pump’s efficiency to a maximum possible value. This can allow a great reduction in the pump drive’s life cycle cost. In the first part of the thesis, a brief introduction in the details of pump drive operation is given. Methods that can be used in the project are presented. Later, the review of available platforms for the project implementation is given. In the second part of the thesis, components of the project are presented. Detailed description for each created component is given. Finally, results of laboratory tests are presented. Acquired results are compared and analyzed. In addition, the operation of created system is analyzed and suggestions for the future development are given.
Resumo:
Tässä diplomityössä on suoritettu pumppauksen energiansäästökartoitus Nordkalkin Lappeenrannan teollisuuslaitoksessa. Tavoitteena on kuvata teollisuuslaitoksen nykyistä pumppauksen tarvetta sekä etsiä energiansäästökohteita. Työn valmistelussa on käytetty apuna energiankulutustiedoista koostettuja energiataseita sekä yrityksen valmistelemia pumppulistoja. Energiansäästökohteita haettaessa tässä tarkastelutyössä huomio on kohdistettu pumppujen säätötapoihin ja mahdollisuuksiin vähentää virtaamaa tai pumppujärjestelmän kokonaisnostokorkeutta. Pumppujärjestelmän toiminnan määrittämisessä on käytetty hyväksi tilavuusvirran ja sähkötehon mittauksia sekä teoreettista tarkastelua kokonaisnostokorkeuden ja pumpun toimintapisteen selvittämiseksi. Kaikkien tarkasteltavien pumppujen osalta on hyödynnetty laitevalmistajien tarjoamia tietoja. Pumppujen vuotuisen toiminnan arviointi on suoritettu tuotantotietojen sekä käyttöhenkilökunnan haastatteluilla kerätyn tiedon perusteella. Työn lopussa on esitetty tarkastelukohteiksi valittujen pumppujärjestelmien energiatehokkuuden parantamiseksi suositeltavia toimenpiteitä. Suositeltavien toimenpiteiden sisältäessä investointeja on niille laskettu nykyarvot sekä takaisinmaksuajat. Energiansäästökohteiksi valittujen pumppujärjestelmien yhteenlaskettu vuosittainen energiansäästö on 352 MWh/a (24640 €/a) investointikustannusten (hankintakustannukset) ollessa 12000 €.