968 resultados para FIXED PROSTHESIS


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The techniques of bone reconstruction for atrophic maxillae have been improved in order to promote bone tissue growth in both height and thickness. The grafts performed with use of autogenous bone is considered the gold standard by most researchers, for demonstrating osteogenic capacity and not to promote antigenic response. However, this type of grafting is not possible to get bone tissue in large quantity for extensive renovations. In recent years, alternatives have been researched to overcome the limitations of autogenous bone. Several alternatives have been investigated to supply the disadvantages of autogenous bone grafts. In such studies, allogeneic bone grafts which are obtained from individuals with different genetic load, but from the same species have been extensively used. They can be indicated in cases of arthrosplasty, surgical knee reconstruction, and large bone defects as well as in oral and maxillofacial reconstruction. Besides showing great applicability and biocompatibility, this type of bone is available in unlimited quantities. To rehabilitate atrophic maxillae an option that has been performed with high success rate is the reconstruction with bone graft followed by osseointegrated dental implants to rehabilitate the patient aesthetics and functionally. This paper aims to show the feasibility of allogenic bone as material for reconstruction of atrophic maxilla, and subsequent rehabilitation with metal ceramic fixed prosthesis implant and dental restoration with accompanying three years through literature review and clinical case report.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: Primary and secondary stabilities of immediately loaded mandibular implants restored with fixed prostheses (FP) using rigid or semirigid splinting systems were clinically and radiographically evaluated. Methods: Fifteen edentulous patients were rehabilitated using hybrid FP; each had 5 implants placed between the mental foramens. Two groups were randomly divided: group 1-FP with the conventional rigid bar splinting the implants and group 2-semi-rigid cantilever extension system with titanium bars placed in the 2 distal abutment cylinders. Primary stability was evaluated using resonance frequency analysis after installation of the implant abutments. The measurements were made at 3 times: T0, at baseline; T1, 4 months after implant placement; and T2, 8 months after implant placement. Presence of mobility and inflammation in the implant surrounding regions were checked. Stability data were submitted to statistical analysis for comparison between groups (P, 0.05). Results: Implant survival rate for the implants was of 100% in both groups. No significant differences in the mean implant stability quotient values were found for both groups from baseline and after the 8-month follow-up. Conclusion: The immediate loading of the implants was satisfactory, and both splinting conditions (rigid and semi-rigid) can be successfully used for the restoration of edentulous mandibles. (Implant Dent 2012;21:486-490)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Obiettivi: Valutare la modalità  più efficace per la riabilitazione funzionale del limbo libero di fibula "single strut", dopo ampie resezioni per patologia neoplastica maligna del cavo orale. Metodi: Da una casistica di 62 ricostruzioni microvascolari con limbo libero di fibula, 11 casi sono stati selezionati per essere riabilitati mediante protesi dentale a supporto implantare. 6 casi sono stati trattati senza ulteriori procedure chirurgiche ad eccezione dell'implantologia (gruppo 1), affrontando il deficit di verticalità  della fibula attraverso la protesi dentaria, mentre i restanti casi sono stati trattati con la distrazione osteogenetica (DO) della fibula prima della riabilitazione protesica (gruppo 2). Il deficit di verticalità  fibula/mandibola è stato misurato. I criteri di valutazione utilizzati includono la misurazione clinica e radiografica del livello osseo e dei tessuti molli peri-implantari, ed il livello di soddisfazione del paziente attraverso un questionario appositamente redatto. Risultati: Tutte le riabilitazioni protesiche sono costituite da protesi dentali avvitate su impianti. L'età  media è di 52 anni, il rapporto uomini/donne è di 6/5. Il numero medio di impianti inseriti nelle fibule è di 5. Il periodo massimo di follow-up dopo il carico masticatorio è stato di 30 mesi per il gruppo 1 e di 38.5 mesi (17-81) di media per il gruppo 2. Non abbiamo riportato complicazioni chirurgiche. Nessun impianto è stato rimosso dai pazienti del gruppo 1, la perdita media di osso peri-implantare registrata è stata di 1,5 mm. Nel gruppo 2 sono stati riportati un caso di tipping linguale del vettore di distrazione durante la fase di consolidazione e un caso di frattura della corticale basale in assenza di formazione di nuovo osso. L'incremento medio di osso in verticalità è stato di 13,6 mm (12-15). 4 impianti su 32 (12.5%) sono andati persi dopo il periodo di follow-up. Il riassorbimento medio peri-implantare, è stato di 2,5 mm. Conclusioni: Le soluzioni più utilizzate per superare il deficit di verticalità  del limbo libero di fibula consistono nell'allestimento del lembo libero di cresta iliaca, nel posizionare la fibula in posizione ideale da un punto di vista protesico a discapito del profilo osseo basale, l'utilizzo del lembo di fibula nella versione descritta come "double barrel", nella distrazione osteogenetica della fibula. La nostra esperienza concerne il lembo libero di fibula che nella patologia neoplastica maligna utilizziamo nella versione "single strut", per mantenere disponibili tutte le potenzialità  di lunghezza del peduncolo vascolare, senza necessità  di innesti di vena. Entrambe le soluzioni, la protesi dentale ortopedica e la distrazione osteogenetica seguita da protesi, entrambe avvitate su impianti, costituiscono soluzioni soddisfacenti per la riabilitazione funzionale della fibula al di là  del suo deficit di verticalità . La prima soluzione ha preso spunto dall'osservazione dei buoni risultati della protesi dentale su impianti corti, avendo un paragonabile rapporto corona/radice, la DO applicata alla fibula, sebbene sia risultata una metodica con un numero di complicazioni più elevato ed un maggior livello di riassorbimento di osso peri-implantare, costituisce in ogni caso una valida opzione riabilitativa, specialmente in caso di notevole discrepanza mandibulo/fibulare. Decisiva è la scelta del percorso terapeutico dopo una accurata valutazione di ogni singolo caso. Vengono illustrati i criteri di selezione provenienti dalla nostra esperienza.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The new Swiss implant system SPI became available three years ago and is used in combination with fixed and removable prosthetic reconstructions. In a pilot study the clinical procedures were evaluated and data of prosthetic complications of maintenance service were collected. 25 patients participated in the study with a total of 79 SPI implants during the time period from 2003-2004. 37 implants were located in the maxilla and 42 implants in the mandible. Two implants failed during the healing period, but no loaded implant was lost. Thus, the survival rate was 97.5% (77/79). 44 implants supported a fixed prosthesis, including nine single crowns and 33 implants were used in combination with removable partial denture. Four implants were used with ball anchor retention, 29 with bar support. The ELEMENT implant with the low implant shoulder allows very good esthetics. Prosthetic complications and maintenance service during the first year of function was comparable with other implant systems. Since the design of the abutment screws, healing caps and screwdriver was changed, the system has become easier in its application.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The rehabilitation of a patient with advanced tooth wear by means of Procera ZrO2 ceramic crowns is described. A healthy, 60 year old patient complained about front teeth esthetics and impaired function due to reduced tooth height. He was aware of bruxism and wished full mouth rehabilitation. The clinical examination showed that tooth wear was generalized, but most teeth could be maintained in both jaws. A staged procedure was planned, starting with a splint therapy and a provisional fixed prosthesis to reestablish correct vertical dimension of occlusion (VDO) and stable occlusal contacts. The new ZrO2 material with the Procera technique was chosen to restore all teeth in both jaws, except the mandible front teeth. In the second treatment phase, crown lengthening of the maxillary front teeth was performed and one implant placed to replace a maxillary premolar. After final tooth preparation, impression taking and bite registration the ZrO2 crown-copings were scanned, processed and completed by veneering. A flat occlusal scheme with stable front teeth guidance was established. The advantage of the presented treatment is the esthetic result in combination with a material of high mechanical and biological quality.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present paper deals with the double crown technique in removable prosthodontics. New ceramic materials like zirconia are increasingly used in combination with CAD/CAM technologies for framework fabrication of fixed prosthesis, tooth- or implant-supported. However, zirconia is also a newly accepted material in removable prosthodontics. It replaces gold alloys for the fabrication of primary telescopic crowns. The Galvanoforming technology is preferably used to fabricate the secondary crowns. The combination of both techniques and materials results in a prosthetic reconstruction of high quality, optimum fit and good biocompatibility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To analyze computer-assisted diagnostics and virtual implant planning and to evaluate the indication for template-guided flapless surgery and immediate loading in the rehabilitation of the edentulous maxilla. MATERIALS AND METHODS: Forty patients with an edentulous maxilla were selected for this study. The three-dimensional analysis and virtual implant planning was performed with the NobelGuide software program (Nobel Biocare, Göteborg, Sweden). Prior to the computer tomography aesthetics and functional aspects were checked clinically. Either a well-fitting denture or an optimized prosthetic setup was used and then converted to a radiographic template. This allowed for a computer-guided analysis of the jaw together with the prosthesis. Accordingly, the best implant position was determined in relation to the bone structure and prospective tooth position. For all jaws, the hypothetical indication for (1) four implants with a bar overdenture and (2) six implants with a simple fixed prosthesis were planned. The planning of the optimized implant position was then analyzed as follows: the number of implants was calculated that could be placed in sufficient quantity of bone. Additional surgical procedures (guided bone regeneration, sinus floor elevation) that would be necessary due the reduced bone quality and quantity were identified. The indication of template-guided, flapless surgery or an immediate loaded protocol was evaluated. RESULTS: Model (a) - bar overdentures: for 28 patients (70%), all four implants could be placed in sufficient bone (total 112 implants). Thus, a full, flapless procedure could be suggested. For six patients (15%), sufficient bone was not available for any of their planned implants. The remaining six patients had exhibited a combination of sufficient or insufficient bone. Model (b) - simple fixed prosthesis: for 12 patients (30%), all six implants could be placed in sufficient bone (total 72 implants). Thus, a full, flapless procedure could be suggested. For seven patients (17%), sufficient bone was not available for any of their planned implants. The remaining 21 patients had exhibited a combination of sufficient or insufficient bone. DISCUSSION: In the maxilla, advanced atrophy is often observed, and implant placement becomes difficult or impossible. Thus, flapless surgery or an immediate loading protocol can be performed just in a selected number of patients. Nevertheless, the use of a computer program for prosthetically driven implant planning is highly efficient and safe. The three-dimensional view of the maxilla allows the determination of the best implant position, the optimization of the implant axis, and the definition of the best surgical and prosthetic solution for the patient. Thus, a protocol that combines a computer-guided technique with conventional surgical procedures becomes a promising option, which needs to be further evaluated and improved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: Com uma consciencialização cada vez maior das populações para a preservação dos dentes naturais, a Endodontia tem assumido uma importância crescente, tendo por objectivo principal a manutenção de dentes funcionais, sem prejudicar a saúde dos pacientes. Estes devem beneficiar de um tratamento segundo o “standard of care”, proporcionado por profissionais competentes. Vários estudos demonstram que a Endodontia é considerada uma área difícil e stressante para os estudantes, exibindo um sentimento de menor confiança na prática clínica, sobretudo no que diz respeito a procedimentos mais complexos, nomeadamente, no tratamento de dentes posteriores. Em 2010, na tentativa de homogeneizar as competências adquiridas pelos Médicos Dentistas (MD), a Associação para a Educação Dentária Europeia (AEDE) definiu critérios para a sua formação pré-graduada, indicando que o MD recém-graduado deve ter adquirido competências e capacidades técnicas que lhe permita começar a sua prática clínica de forma independente. Objectivos: Analisar os conhecimentos adquiridos e as dificuldades sentidas na área da Endodontia pelos alunos do 4º e 5º anos do Mestrado Integrado em Medicina Dentária da Faculdade de Ciências de Saúde (FCS) da Universidade Fernando Pessoa (UFP), fazendo, igualmente, uma abordagem ao ensino ministrado na área da Endodontia face aos resultados obtidos. Materiais e Métodos: Este trabalho está dividido em duas partes: revisão bibliográfica e investigação científica. A revisão bibliográfica do tema engloba o ensino graduado em Medicina Dentária, o uso de isolamento absoluto (IA) na prática clínica de Endodontia, a instrumentação manual versus rotatória, a influência no sucesso do tratamento endodôntico (TE) da sua execução por estudantes do 4º e 5º ano, as Guidelines para o TE e o ensino de Endodontia na UFP. A pesquisa bibliográfica foi efectuada através da base de dados PubMed, tendo sido utilizadas, em diferentes combinações, as seguintes palavras-chave: ”Endodontics”, “teaching”; “pre-clinical”; “undergraduate”; “Clinical”; “treatment” e “Europe”. O trabalho de investigação consistiu na elaboração, aprovação pela Comissão de Ética da UFP e posterior aplicação de um questionário destinado aos alunos do 4º e 5º ano do Mestrado Integrado em Medicina Dentária da FCS-UFP. A população estimada de alunos do 4º ano foi de 190 alunos e a de 5º ano de 150 alunos, o que perfaz um total de 340 alunos. Dos inquéritos respondidos, apenas foram considerados 338, uma vez que dois foram anulados pois continham respostas inválidas. Resultados: A “condição socioeconómica do paciente” foi considerada a causa menos relevante para avaliar um caso endodôntico, tendo sido apontada por 34,3% dos alunos. Assinala-se que 92% dos alunos de 4º ano e 93,3% dos alunos de 5º ano consideram que os molares superiores são os dentes mais difíceis de tratar, sendo a visibilidade uma das principais razões para esta opinião. O grau de dificuldade para a colocação do IA é definido como “Elevado” para a maioria dos alunos de 4º ano. A maior parte dos alunos de 5º ano considera que o grau de dificuldade para a “Determinação do tipo de reconstrução/prótese fixa mais indicada” é “Elevado”. O passo do TE onde os alunos do 4º ano se sentem mais confiantes é no “Diagnóstico de cárie”, sendo que os alunos do 5º ano se sentem mais confiantes ao realizar o “TE em dentes com 1 ou 2 canais”. O “Conteúdo leccionado nas aulas teóricas” foi considerado o principal aspecto positivo do ensino endodôntico. Por outro lado, o “Número de actos clínicos realizados” foi considerado o principal aspecto negativo, tanto para alunos de 4º como de 5º ano. Em ambos os anos, os principais pontos que os alunos acham que devem ser melhorados são o “Número de pacientes nas aulas clínicas” e a “Aprendizagem da técnica de instrumentação mecanizada/obturação termoplástica”. As principais preocupações referidas, tanto por alunos de 4º como de 5º anos, foram a “Insegurança na prática clínica” e a “Dificuldade em encontrar ofertas profissionais”. Relativamente à qualidade dos seus TE existe um número significativo de alunos do 5º ano que já se auto-avaliam como “Bons” (33,6%), por comparação com os do 4º ano (21,2%), sendo a auto-avaliação de “Razoável” dominante em ambos os anos de formação. Conclusões: Conclui-se que na disciplina de Endodontia na FCS-UFP, são seguidas as Guidelines da European Society of Endodontology (ESE), sendo que estas indicam o protocolo mais correcto a seguir durante o Tratamento Endodôntico Não-Cirúrgico (TENC). Contudo, o reduzido número de actos clínicos e a consequente falta de prática faz com que os alunos se sintam pouco confiantes ao iniciar a sua actividade profissional.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this article is to describe a successful clinical protocol for prosthodontic rehabilitation of a patient with a skeletal Class III malocclusion using a fixed-detachable maxillary prosthesis supported by 6 implants and the MK1 attachment system. The patient was followed up for 8 years. A 46-year-old edentulous woman with a skeletal Class III malocclusion expressed dissatisfaction with her old existing maxillary denture from an esthetic point of view and frustration regarding its function. A fixed-detachable maxillary prosthesis using the MK1 attachment system was made. The patient was followed up clinically and radiographically for 8 years. No bone loss, fracture of prosthetic components, or fracture of the prosthesis was detected in that period. A fixed detachable maxillary prosthesis using the MK1 attachment system is a treatment option for patients with Class III malocclusions who opt not to undergo orthognathic surgery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of modern odontology is to reconstitute to the patient the comfort, the function, the aesthetic form, the phonetic capability, and normal health. However, the more the patient is toothless, the more this objective becomes difficult inside traditional dentistry. As a result of continuous research of materials and techniques, permissible success is now a reality, whitewashing many challenging clinical situations. Thus, the objective of the article was to present a clinical case where association of the universal cast to long abutment pillars and EsthetiCone were used for aesthetic whitewashing. A man presented to the clinic of the Faculty of Dentistry, Universidade Estadual Paulista. After clinical examination and radiographic evaluation evidenced the necessity of substitution of fixed prostheses (15-25), he was presented with disadaptation and a favorable aesthetic solution. Ahead of the evaluated picture and considering the extension of the toothless space made, it was opted more, to the accomplishment of surgery, the setting of 2 implantations in the region and 2 in each edentate side of the posterior portion of the jaw. On 6 implants and 2 teeth, 10 metal ceramic crowns had been confectioned: 4 of them being joined in the region of the 12 to the 22 and the other 6 as unit crowns in the region of the 13, the 14, the 15, the 23, the 24, and the 25. The carried-through treatment was capable to return the aesthetic form, the function, the phonetic capability, the comfort, and the health of the verbal socket.