922 resultados para FACIAL FRACTURES


Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIM: The aim of this study was to analyse the character of assault-related facial fractures in central Switzerland and to compare their prevalence with the data presented in similar reports from other countries. MATERIAL: The present study comprised 65 patients with assault-related maxillofacial fractures treated in the Department of Cranio-Maxillofacial Surgery, University Hospital of Bern between 2000 and 2002. METHODS: The mechanism, the causes of the injuries and the location of the fractures were analysed by reviewing emergency and hospital records. Concomitant injuries were also studied. RESULTS: The mean age of the patients was 33 years with the largest group being below 25 years. The male-to-female ratio was 56:9. The most common causes of assault-related injuries were fights, most frequently facial blows, accounting for 92.5% of all patients. Seventy-six per cent of the fractures occurred in the middle and upper facial skeleton with a predominance of 2:1 for the left side. In 39 patients (60%) surgery was necessary, with a mean hospital stay of 3.3 days. Thirty-five patients (54%) had concomitant injuries. Alcohol and drug abuse was found in 15 patients (23%). CONCLUSION: It seems that mostly young men suffer assault-related maxillofacial injuries. A contributing factor to the increased disposition for violence could be alcohol and drug abuse. Therefore, national prevention programmes for alcohol or drug abuse and addiction might have a positive effect on reducing the incidence of assault-related maxillofacial injuries.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo do estudo foi mensurar os gastos diretos do Sistema Único de Saúde (SUS) com internações por causas externas em São José dos Campos, São Paulo, Brasil. Foram estudadas as internações por lesões decorrentes de causas externas, respectivamente capítulos XIX e XX da CID-10, no primeiro semestre de 2003, no Hospital Municipal Dr. José de Carvalho Florence. Foram analisados os valores pagos através do SUS, após a verificação da qualidade dos dados nos prontuários de 976 internações. Os maiores gastos totais foram por internações decorrentes de acidentes de transporte e quedas. O maior gasto médio de internação foi por acidentes de transporte (R$ 614,63), seguido das agressões (R$ 594,90). As lesões que representaram maior gasto médio foram as fraturas de pescoço (R$ 1.191,42) e traumatismo intracraniano (R$ 1.000,44). As internações com maior custo-dia foram fraturas do crânio e dos ossos da face (R$ 166,72) e traumatismo intra-abdominal (R$ 148,26). Os resultados encontrados demonstraram que os acidentes de transporte, as quedas e as agressões são importantes fontes de gastos com internações por causas externas no município.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This retrospective study evaluated the epidemiology, treatment and complications of mandibular fracture associated, or not associated, with other facial fractures, when the influence of the surgeon`s skill and preference for ally rigid internal fixation (RIF) system devices was minimized. The files of 700 patients with facial trauma were available, and 126 files were chosen for review. Data were collected regarding gender, age, race, date of trauma, date of surgery, addictions, etiology, signs and symptoms, fracture area, complications, treatment performed, date of hospital discharge.. and medication. 126 patients suffered mandibular fractures associated, or not, with other maxillofacial fractures, and a total of 201 mandibular fractures were found. The incidence of mandibular fractures was more prevalent in males, in Caucasians and during the third decade of life. The most common site was the condyle, followed by the mandibular body. The therapy applied was effective in handling this type of fracture and the Success rates were comparable with other published data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Precise repositioning of a fractured zygoma is difficult. The traditional approach is through an eyebrow incision, but it can produce a scar that causes aesthetic and psychological problems for the patient. We describe the supratarsal fold approach to expose the frontozygomatic suture and to reduce small displacements of frontal sinus anterior wall; it gives good access and excellent aesthetic results. (C) 2007 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O trauma do seio frontal não é raro, correspondendo a 8% das fraturas faciais. Pode afetar a lâmina anterior e/ou posterior, com ou sem envolvimento do ducto nasofrontal. Tem alto potencial para complicações e seu manejo ainda é controvertido em algumas situações. OBJETIVO: Apresentar a epidemiologia, o diagnóstico e tratamento clínico e cirúrgico de 24 pacientes com fratura do seio frontal. MATERIAL E MÉTODOS: Estudo retrospectivo, não randomizado, de 24 pacientes com fratura de seio frontal operados no Hospital das Clínicas da Faculdade de Medicina de Botucatu, São Paulo, Brasil. RESULTADOS: Dos 24 pacientes, 16 tinham fraturas da lâmina externa e 8, da lâmina interna e externa. em 2 casos havia lesão do ducto nasofrontal. Vinte (83,4%) pacientes tiveram fraturas faciais associadas e em 13 (54,2%) foram observadas complicações intracranianas. A incisão em asa de borboleta, abaixo da sobrancelha, foi empregada na maioria dos casos cirúrgicos com bom resultado estético. Fixação dos fragmentos ósseos com diferentes materiais (fio de aço, mononylon, miniplacas de titânio) e, se necessário, reconstrução da tábua anterior com material aloplástico ou osso parietal. CONCLUSÃO: A causa principal das fraturas do seio frontal é acidente com veículos. O tratamento depende de sua complexidade, pois comumente há lesões cranioencefálicas associadas. As técnicas cirúrgicas utilizadas são as incisões, retalho bicoronal ou na sobrancelha, infra-orbital (em asa de borboleta), associadas à cirurgia endoscópica em casos de infecção fístula liquórica e complicações orbitárias.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Panfacial fractures usually refer to simultaneous facial fractures, which affect the upper, middle, and lower thirds of the face. The management of panfacial fracture is complex because of the lack of reliable landmarks. Literature has shown many approaches for management of panfacial fractures. Every segment of bone has a precise function in the repair. Therefore, the bottom-up and outside-in sequence is the most widely used approach in the management of panfacial fractures. These facial fractures present remarkable challenges for both experienced and inexperienced surgeons. This article aimed to report a case of a panfacial fracture (mandibular condylar and symphysis fractures associated with an atypical Le Fort III fracture) in a 48-year-old man. The patient was successfully treated using bottom-up and outside-in sequence by accessing all facial injuries. Postoperatively, radiograph examination revealed good reduction and fixation of titanium plates, and physical examination revealed good functional and esthetic outcomes. Copyright © 2013 by Mutaz B. Habal, MD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The mandibular injuries account for about 20% to 50% of cases of facial fractures. Some consider the jaw the second most commonly fractured bone of the skull, and is the only mobile bone of the facial framework, which results in decreased stability compared to the trauma. When one takes into account the degree of airway obstruction in patients with facial fractures, the problem becomes much more serious since it is one of the most troubling complications of trauma. Objective: the relevance of the topic is aimed to report a case of a patient victim of mandibular fracture associated with trauma to the trachea. Case report: Case report: Patient 24 years old patient with tracheal trauma concomitant mandibular fracture surgically treated in conjunction with the thoracic surgeon. After 5 months postoperatively, the patient is in good condition general, no complaints. Final comments: This form is observed that the key to proper treatment of tracheal trauma associated with facial fractures is the knowledge of the type of injury, and an accurate diagnosis multidisciplinary.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Bars and steel wires are the most commonly used methods to achieve maxillomandibular fixation, although there are numerous alternatives described for this same purpose. In cases of edentulous candidates for the conservative treatment of facial fractures, none of the conventional methods can be instituted for maxillomandibular fixation. Fixation in such cases is achieved with the aid of the total dentures of the patient or the confection of splints, but these methods lead to eating and oral hygiene problems. This article reports the case of an edentulous patient with a comminuted mandible fracture treated with a rarely described technique in which intermaxillary fixation was achieved with titanium miniplates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to compare the bone repair along a mandibular body osteotomy stabilized with 2.0 mm absorbable and metallic systems. 12 male, adult mongrel dogs were divided into two groups (metallic and absorbable) and subjected to unilateral osteotomy between the mandibular third and fourth premolars, which was stabilized by applying two 4-hole plates. At 2 and 18 weeks, three dogs from each group were killed and the osteotomy sites were removed and divided equally into three parts: the upper part was labelled the tension third (TT), the lower part the compression third (CT), and the part between the TT and CT the intermediary third (IT). Regardless of the treatment system, union between the fragments was observed at 18 weeks and the CT showed more advanced stages of bone repair than the TT. Histometric analysis did not reveal any significant differences among the 3 parts or systems in the distance between bone fragments at 2 weeks. Although at 18 weeks the proportions of newly formed bone did not differ among TT, IT and CT, significantly enhanced bone formation was observed in all sections for the metallic group. The patterns of repair were distinct between treatments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There has been a significant increase in the number of facial fractures stemming from sport activities in recent years, with the nasal bone one of the most affected structures. Researchers recommend the use of a nose protector, but there is no standardization regarding the material employed. Clinical experience has demonstrated that a combination of a flexible and rigid layer of ethylene vinyl acetate (EVA) offers both comfort and safety to practitioners of sports. The aim of the present study was the investigation into the stresses generated by the impact of a rigid body on the nasal bone on models with and without an EVA protector. For such, finite element analysis was employed. A craniofacial model was constructed from images obtained through computed tomography. The nose protector was modeled with two layers of EVA (1 mm of rigid EVA over 2 mm of flexible EVA), following the geometry of the soft tissue. Finite element analysis was performed using the LS Dyna program. The bone and rigid EVA were represented as elastic linear material, whereas the soft tissues and flexible EVA were represented as hyperelastic material. The impact from a rigid sphere on the frontal region of the face was simulated with a constant velocity of 20 m s-1 for 9.1 mu s. The model without the protector served as the control. The distribution of maximal stress of the facial bones was recorded. The maximal stress on the nasal bone surpassed the breaking limit of 0.130.34 MPa on the model without a protector, while remaining below this limit on the model with the protector. Thus, the nose protector made from both flexible and rigid EVA proved effective at protecting the nasal bones under high-impact conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: The literature shows that hardware removal rates after the fixation of maxillofacial fractures with miniplates are not insignificant. The aim of the present survey was to clarify the policies of Finnish oral and maxillofacial consultants for the removal of titanium miniplates after the treatment of facial fractures in adults. Additional aims were to clarify the factors influencing plate removal policy in general, and the reasons for routine plate removal in particular. MATERIALS AND METHODS: Twenty-six consultant oral and maxillofacial surgeons responded to a questionnaire about miniplate removal policy after treating 5 types of simple, noncomminuted fractures. RESULTS: Overall, routine plate removal was uncommon. However, 12 consultants (46.2%) routinely removed the plate after treating mandibular angle fractures, and simultaneously extracted the third molar because of an increased risk of infection. Most respondents (88.5%) stated that clinical experience guided their plate-removal policy. A policy of routine plate removal was most infrequent among the consultants who had the most experience. CONCLUSIONS: The literature provides no definitive answer to the question of whether routine removal of miniplates could or should be indicated, and in what situations. Considering the fairly significant frequency of plate-related complications in general and infection-related complications in particular, long-term follow-up after treatment is indicated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To clarify the patterns of frontobasal and frontosinal fractures in children and teenagers and to analyze whether the patterns relate to developmental stage of the facial skeleton.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To perform a comparative evaluation of the mechanical resistance of simulated fractures of the mandibular body which were repaired using different fixation techniques with two different brands of 2.0 mm locking fixation systems. Four aluminum hemimandibles with linear sectioning simulating a mandibular body fracture were used as the substrates and were fixed using the two techniques and two different brands of fixation plate. These were divided into four groups: groups I and II were fixed with one four-hole plate, with four 6 mm screws in the tension zone and one four-hole plate, with four 10 mm screws in the compression zone; and groups III and IV were fixed with one four-hole plate with four 6 mm screws in the neutral zone. Fixation plates manufactured by Tóride were used for groups I and III, and by Traumec for groups II and IV. The hemimandibles were submitted to vertical, linear load testing in an Instron 4411 servohydraulic mechanical testing unit, and the load/displacement (3 mm, 5 mm and 7 mm) and the peak loads were measured. Means and standard deviations were evaluated applying variance analysis with a significance level of 5%. The only significant difference between the brands was seen at displacements of 7 mm. Comparing the techniques, groups I and II showed higher mechanical strength than groups III and IV, as expected. For the treatment of mandibular linear body fracture, two locking plates, one in the tension zone and another in the compression zone, have a greater mechanical strength than a single locking plate in the neutral zone.