884 resultados para FACE MASK


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The arterial pharmacokinetics of ketamine and norketamine enantiomers after racemic ketamine or S-ketamine i.v. administration were evaluated in seven gelding ponies in a crossover study (2-month interval). METHODS: Anaesthesia was induced with isoflurane in oxygen via a face-mask and then maintained at each pony's individual MAC. Racemic ketamine (2.2 mg kg(-1)) or S-ketamine (1.1 mg kg(-1)) was injected in the right jugular vein. Blood samples were collected from the right carotid artery before and at 1, 2, 4, 8, 16, 32, 64, and 128 min after ketamine administration. Ketamine and norketamine enantiomer plasma concentrations were determined by capillary electrophoresis. Individual R-ketamine and S-ketamine concentration vs time curves were analysed by non-linear least square regression two-compartment model analysis using PCNonlin. Plasma disposition curves for R-norketamine and S-norketamine were described by estimating AUC, C(max), and T(max). Pulse rate (PR), respiratory rate (R(f)), tidal volume (V(T)), minute volume ventilation (V(E)), end-tidal partial pressure of carbon dioxide (PE'(CO(2))), and mean arterial blood pressure (MAP) were also evaluated. RESULTS: The pharmacokinetic parameters of S- and R-ketamine administered in the racemic mixture or S-ketamine administered separately did not differ significantly. Statistically significant higher AUC and C(max) were found for S-norketamine compared with R-norketamine in the racemic group. Overall, R(f), V(E), PE'(CO(2)), and MAP were significantly higher in the racemic group, whereas PR was higher in the S-ketamine group. CONCLUSIONS: Norketamine enantiomers showed different pharmacokinetic profiles after single i.v. administration of racemic ketamine in ponies anaesthetised with isoflurane in oxygen (1 MAC). Cardiopulmonary variables require further investigation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Oxidative killing is the primary defense against surgical pathogens; risk of infection is inversely related to tissue oxygenation. Subcutaneous tissue oxygenation in obese patients is significantly less than in lean patients during general anesthesia. However, it remains unknown whether reduced intraoperative tissue oxygenation in obese patients results from obesity per se or from a combination of anesthesia and surgery. In a pilot study, we tested the hypothesis that tissue oxygenation is reduced in spontaneously breathing, unanesthetized obese volunteers. METHODS: Seven lean volunteers with a body mass index (BMI) of 22 +/- 2 kg/m(2) were compared to seven volunteers with a BMI of 46 +/- 4 kg/m(2). Volunteers were subjected to the following oxygen challenges: (1) room air; (2) 2 l/min oxygen via nasal prongs, (3) 6 l/min oxygen through a rebreathing face mask; (4) oxygen as needed to achieve an arterial oxygen pressure (arterial pO(2)) of 200 mmHg; and (5) oxygen as needed to achieve an arterial pO(2) of 300 mmHg. The oxygen challenges were randomized. Arterial pO(2) was measured with a continuous intraarterial blood gas analyzer (Paratrend 7); deltoid subcutaneous tissue oxygenation was measured with a polarographic microoxygen sensor (Licox). RESULTS: Subcutaneous tissue oxygenation was similar in lean and obese volunteers: (1) room air, 52 +/- 10 vs 58 +/- 8 mmHg; (2) 2 l/min, 77 +/- 25 vs 79 +/- 24 mmHg; (3) 6 l/min, 125 +/- 43 vs 121 +/- 25 mmHg; (4) arterial pO(2) = 200 mmHg, 115 +/- 42 vs 144 +/- 23 mmHg; (5) arterial pO(2) = 300 mmHg, 145 +/- 41 vs 154 +/- 32 mmHg. CONCLUSION: In this pilot study, we could not identify significant differences in deltoid subcutaneous tissue oxygen pressure between lean and morbidly obese volunteers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: It has been suggested that infants dynamically regulate their tidal flow and end-expiratory volume level. The interaction between muscle activity, flow and lung volume in spontaneously sleeping neonates is poorly studied, since it requires the assessment of transcutaneous electromyography of respiratory muscles (rEMG) in matched comparison to lung function measurements. METHODS: After determining feasibility and repeatability of rEMG in 20 spontaneously sleeping healthy neonates, we measured the relative impact of intercostal and diaphragmatic EMG activity in direct comparison to the resulting tidal flow and FRC. RESULTS: We found good feasibility, repeatability and correlation of timing indices between rEMG activity and flow. The rEMG amplitude was significantly dependent on the resistive load of the face mask. Diaphragm and intercostal muscle activity commenced prior to the onset of flow and remained active during the expiratory cycle. The relative contribution of intercostal and diaphragmatic activity to flow was variable and changed dynamically. CONCLUSION: Using matched rEMG, air flow and lung volume measurements, we have found good feasibility and repeatability of intercostal and diaphragm rEMG measurements and provide the first quantitative measures of the temporal relationship between muscle activity and flow in spontaneously sleeping healthy neonates. Lung mechanical function is dynamically regulated and adapts on a breath to breath basis. So, non-invasive rEMG measurements alone or in combination with lung function might provide a more comprehensive picture of pulmonary mechanics in future studies. The data describing the timing of EMG and flow may be important for future studies of EMG triggered mechanical ventilation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Little is known about the physiological mechanisms subserving the experience of air hunger and the affective control of breathing in humans. Acute hunger for air after inhalation of CO2 was studied in nine healthy volunteers with positron emission tomography. Subjective breathlessness was manipulated while end-tidal CO2- was held constant. Subjects experienced a significantly greater sense of air hunger breathing through a face mask than through a mouthpiece. The statistical contrast between the two conditions delineated a distributed network of primarily limbic/paralimbic brain regions, including multiple foci in dorsal anterior and middle cingulate gyrus, insula/claustrum, amygdala/periamygdala, lingual and middle temporal gyrus, hypothalamus, pulvinar, and midbrain. This pattern of activations was confirmed by a correlational analysis with breathlessness ratings. The commonality of regions of mesencephalon, diencephalon and limbic/paralimbic areas involved in primal emotions engendered by the basic vegetative systems including hunger for air, thirst, hunger, pain, micturition, and sleep, is discussed with particular reference to the cingulate gyrus. A theory that the phylogenetic origin of consciousness came from primal emotions engendered by immediate threat to the existence of the organism is discussed along with an alternative hypothesis by Edelman that primary awareness emerged with processes of ongoing perceptual categorization giving rise to a scene [Edelman, G. M. (1992) Bright Air, Brilliant Fire (Penguin, London)].

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[Derricotte is wearing a leather helmet with a face mask, possibly first face mask on a UM helmet.]

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este estudo avaliou os efeitos esqueléticos da tração reversa da maxila utilizando imagens 2D (telerradiografia lateral) geradas a partir da tomografia de feixe cônico (imagens 3D). A amostra foi composta por 20 crianças (15 do gênero feminino, e 5 do masculino), com idade variando de 5,6 a 10,7 anos que apresentavam má-oclusão de Classe III de Angle. A tomografia foi realizada antes do tratamento (T1) e logo após o tratamento (T2). O tratamento foi realizado por meio da tração reversa da maxila utilizando-se o aparelho expansor Hyrax associado à máscara facial individualizada, com força de 600 a 800g de cada lado, durante 14 horas por dia. A correção da relação de caninos em Classe I ou com sua sobrecorreção em Classe II foi obtida após 4 a 8 meses de tratamento. Para verificar o erro sistemático e casual foi utilizado o teste t pareado e a fórmula de Dahlberg, respectivamente. O teste t pareado (p<0,05) mostrou diferença significante entre as medidas cefalométricas obtidas em T1 e T2. Na maxila houve aumento do SNA 2,2°, A-Nperp 1,47mm e em Co-A 2,58mm. Na mandíbula, SNB diminuiu -0,54° e P-Nperp, -1,45mm, enquanto Co-Gn aumentou 1,04mm. Houve melhora na relação maxilo-mandibular ANB 2,74° e Wits 4,23mm. As variáveis GoGn.SN, Gn.SN, FH.Md, Mx.Md, e AFAI aumentaram demonstrando que houve uma rotação da mandíbula no sentido horário. O plano palatino rotacionou no sentido anti-horário. Pode se concluir que o tratamento de tração reversa da maxila na idade precoce promoveu uma melhora na relação maxilo-mandibular devido a um avanço da maxila e um deslocamento da mandíbula para baixo e para trás.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background There is a potential risk of infection with blood-borne viruses if a doctor receives a blood splash to a mucous membrane. The quantification of facial contamination with blood has never been documented in the context of dermatological surgery. Objectives (i) To identify the number of facial blood splashes that occur during skin surgery and to identify the procedures that present higher risks for the operator and assistant. (ii) To assess the provision of eye protection and attitudes to its use in dermatological surgery in the U.K. Methods (i) Prospective, observational study in the skin surgery suite of a U.K. teaching hospital assessing 100 consecutive dermatological surgery procedures, plus 100 consecutive operations in which an assistant was present. Primary outcome: number of face-mask visors with at least one blood splash. Secondary outcomes: to identify if any of the following variables influenced the occurrence of a blood splash: grade of operator, site and type of procedure, and the use of electrocautery. (ii) A postal survey of all U.K.-based members of the British Society of Dermatological Surgery (BSDS) was conducted assessing facilities available and the attitudes of U.K.-based clinicians to the use of face masks during surgery. Results (i) In 33% of all surgical procedures there was at least one facial splash to the operator (range 1–75) and in 15% of procedures the assistant received at least one splash (range 1–11). Use of monopolar electrocautery was significantly less likely to result in splashes to the mask compared with bipolar electrocautery [odds ratio (OR) 0Æ04; 95% confidence interval (CI) 0Æ01–0Æ19]. Compared with the head/neck, operations on the body were significantly more likely to result in splashes to the mask (OR 6Æ52) (95% CI 1Æ7–25Æ07). The type of procedure and the status of the operator did not have a bearing on the likelihood of receiving a splash to the mask. (ii) From the survey, 33 of 159 (20Æ8%) of BSDS members had no face masks available and 54 of 159 (34Æ0%) did not wear any facial protection while operating. The majority (53Æ5%) thought they received a splash in £ 1% of procedures. Conclusions There is a substantial risk of a splash of blood coming into contact with the face during dermatological surgery for both the operator and assistant, regardless of the procedure. The risk of receiving a blood splash to the face may be substantially underestimated by U.K.-based dermatologists. The use of protective eyewear is advisable at all times, but particularly when using bipolar electrocautery, or when operating on high-risk individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are several ways of controlling the propagation of a contagious disease. For instance, to reduce the spreading of an airborne infection, individuals can be encouraged to remain in their homes and/or to wear face masks outside their domiciles. However, when a limited amount of masks is available, who should use them: the susceptible subjects, the infective persons or both populations? Here we employ susceptible-infective-recovered (SIR) models described in terms of ordinary differential equations and probabilistic cellular automata in order to investigate how the deletion of links in the random complex network representing the social contacts among individuals affects the dynamics of a contagious disease. The inspiration for this study comes from recent discussions about the impact of measures usually recommended by health public organizations for preventing the propagation of the swine influenza A (H1N1) virus. Our answer to this question can be valid for other eco-epidemiological systems. (C) 2010 Elsevier BM. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new technology is being proposed as a solution to the problem of unintentional facial detection and recognition in pictures in which the individuals appearing want to express their privacy preferences, through the use of different tags. The existing methods for face de-identification were mostly ad hoc solutions that only provided an absolute binary solution in a privacy context such as pixelation, or a bar mask. As the number and users of social networks are increasing, our preferences regarding our privacy may become more complex, leaving these absolute binary solutions as something obsolete. The proposed technology overcomes this problem by embedding information in a tag which will be placed close to the face without being disruptive. Through a decoding method the tag will provide the preferences that will be applied to the images in further stages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT The Non-invasive Ventilation represents an alternative from ventilatory support, being frequently used in the treatment of respiratory failure. There are many complications associated with this technique, related to the pressure / air flow and the application of interfaces, being this one the focus of the article. The most appropriate interface selection allows a successful technique; the interface must be based on anatomical characteristics of the patient, cutaneous integrity and ventilation requirements. The Nurse plays a key role selecting the appropriate interface; technical monitoring and prevention of complications. The objective of the study is identify sensitive results to nursing care in the prevention of pressure ulcers (PPU) of the face, in adult and elderly submitted to NIV. This research was through EBSCO (CINAHL (Plus with Full Text) and MEDLINE (Plus with Full Text), with selection of full text articles between 2003-01-01 and 31.12.2013. We used the method of PI[C]O and was selected 13 articles from a total of 353. It was identified a set of specific interventions that prevent the appearing of pressure ulcer (PU), and according to Doran (2011), promotes sensitivity to nursing care results. The nursing interventions in adults with NIV have a direct impact on health outcomes, with preventing and resolving complications, with contribution in terms of effective disease control, adherence to the treatment regimen and consequent increase in life quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: o objetivo deste trabalho foi classificar e determinar a prevalência dos indivíduos portadores de comprometimento vertical nas relações faciais, conforme a severidade da discrepância e, especialmente, dos portadores de Padrão Face Longa. MÉTODOS: a amostra constou de 5.020 sujeitos de nacionalidade brasileira, de ambos os sexos, com idades entre 10 anos e 16 anos e 11 meses, matriculados no Ensino Fundamental do município de Bauru-SP. O exame da morfologia facial constou da observação direta da face, em normas frontal e lateral, sempre com os lábios em repouso, buscando identificar aqueles indivíduos que apresentassem comprometimento vertical nas relações faciais. Esses, uma vez identificados, foram classificados, considerando-se a severidade, em três subtipos: moderado, médio e grave. Para fins de determinação da prevalência dos portadores de Padrão Face Longa, apenas os classificados como dos subtipos médio e grave foram considerados. RESULTADOS: observou-se uma prevalência de 34,94% de comprometimento vertical nas relações faciais e 14,06% de Padrão Face Longa. CONCLUSÃO: os resultados obtidos no presente estudo permitiram concluir que a prevalência do comprometimento vertical nas relações faciais e do Padrão Face Longa foi maior do que a presumida com base na literatura.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: definir valores cefalométricos esqueléticos e dentários para adolescentes brasileiros com Padrão Face Longa. MÉTODOS: a amostra foi constituída de telerradiografias em norma lateral de 30 pacientes com Face Longa, sendo 17 do sexo feminino e 13 do masculino; e 30 pacientes face Padrão I, 15 do sexo masculino e 15 do feminino, no estágio de dentadura permanente durante a adolescência. As características do Padrão Face Longa foram definidas clinicamente, pela análise facial. As seguintes grandezas cefalométricas foram avaliadas: (1) Comportamento sagital das bases apicais (SNA, SNB, ANB, NAP, Co-A, Co-Gn); (2) Comportamento vertical das bases apicais (SN.PP, SN.PM, ângulo goníaco, AFAT, AFAI, AFAM, AFP, AFATperp, AFAIperp); (3) Comportamento dentoalveolar (1-PP, 6-PP, 1-PM, 6-PM, 1.PP, IMPA); e (4) Proporção entre as alturas faciais (AFAIPerp/AFATPerp, AFAI/AFAT, AFAM/AFAI). RESULTADOS E CONCLUSÕES: o erro vertical na Face Longa concentra-se no terço inferior. A maxila apresenta uma maior altura dentoalveolar e a mandíbula, com morfologia mais vertical, mostra maior rotação no sentido horário. Essas características morfológicas e espaciais acarretam alterações sagitais e verticais no esqueleto e alterações verticais dentoalveolares. No sentido sagital, os ângulos de convexidade facial estão aumentados. No sentido vertical, as alturas faciais anteriores total e inferior estão aumentadas. O componente dentoalveolar está mais longo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motivated by a recently proposed biologically inspired face recognition approach, we investigated the relation between human behavior and a computational model based on Fourier-Bessel (FB) spatial patterns. We measured human recognition performance of FB filtered face images using an 8-alternative forced-choice method. Test stimuli were generated by converting the images from the spatial to the FB domain, filtering the resulting coefficients with a band-pass filter, and finally taking the inverse FB transformation of the filtered coefficients. The performance of the computational models was tested using a simulation of the psychophysical experiment. In the FB model, face images were first filtered by simulated V1- type neurons and later analyzed globally for their content of FB components. In general, there was a higher human contrast sensitivity to radially than to angularly filtered images, but both functions peaked at the 11.3-16 frequency interval. The FB-based model presented similar behavior with regard to peak position and relative sensitivity, but had a wider frequency band width and a narrower response range. The response pattern of two alternative models, based on local FB analysis and on raw luminance, strongly diverged from the human behavior patterns. These results suggest that human performance can be constrained by the type of information conveyed by polar patterns, and consequently that humans might use FB-like spatial patterns in face processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional discretizations used in numerical analyses of tunnel construction normally include excavation step lengths much shorter than tunnel cross-section dimensions. Simulations have usually worked around this problem by using excavation steps that are much larger than the actual physical steps used in a real tunnel excavation. In contrast, the analyses performed in this study were based on finely discretized meshes capable of reproducing the excavation lengths actually used in tunnels, and the results obtained for internal forces are up to 100% greater than those found in other analyses available in the literature. Whereas most reports conclude that internal forces depend on support delay length alone, this study shows that geometric path dependency (reflected by excavation round length) is very strong, even considering linear elasticity. Moreover, many other solutions found in the literature have also neglected the importance of the relative stiffness between the ground mass and support structure, probably owing to the relatively coarse meshes used in these studies. The analyses presented here show that relative stiffness may account for internal force discrepancies in the order of 60%. A dimensionless expression that takes all these parameters into account is presented as a good approximation for the load transfer mechanism at the tunnel face.