47 resultados para EuroSCORE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To analyse our results of using a double arterial perfusion strategy to avoid lower body hypothermic circulatory arrest after extensive thoracic aortic surgery. METHODS We analysed the intra- and perioperative courses of 10 patients (median age 58 years, median logistic EuroSCORE 14.6) who underwent extensive thoracic aortic surgery with a double arterial perfusion strategy. The main goal of double arterial perfusion is to separate myocardial and supra-aortic from systemic perfusion. Aortic repair starts at the most distal level of the descending aorta, followed by reinsertion of the supra-aortic vessels, and ends with completion of the proximal anastomosis or by any kind of root repair as needed. RESULTS Seven of 10 patients had prior surgery of the thoracic aorta. Indications for surgery were post-dissection aneurysm in 4 patients, true aneurysm in 3, anastomotic aneurysms in 2 and Type B aortic dissection with pseudo-coarctation in 1. Surgical access was performed through median sternotomy with left hemi-clamshell extension in all cases. There was no in-hospital mortality, but perioperative neurological symptoms occurred in 2 patients. These 2 patients developed delayed stroke (after awaking) after an initial uneventful clinical course, and in 1 of them, neurological symptoms resolved completely during follow-up. The median follow-up was 7 (±13) months. There was no death and no need for additional redo surgery during this observational period. CONCLUSIONS Extensive surgery of the thoracic aorta using a double arterial perfusion technique in order to avoid lower body hypothermic circulatory arrest is an attractive option. Further refinements of this technique may enable the safe and effective simultaneous multisegmental treatment of thoracic aortic pathology in patients who would otherwise have to undergo a two-step surgical approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Peak levels of troponin T (TnT) reliably predict morbidity and mortality after cardiac surgery. However, the therapeutic window to manage CABG-related in-hospital complications may close before the peak is reached. We investigated whether early TnT levels correlate as well with complications after coronary artery bypass grafting (CABG) surgery. METHODS A 12 month consecutive series of patients undergoing elective isolated CABG procedures (mini-extra-corporeal circuit, Cardioplegic arrest) was analyzed. Logistic regression modeling was used to investigate whether TnT levels 6 to 8 hours after surgery were independently associated with in-hospital complications (either post-operative myocardial infarction, stroke, new-onset renal insufficiency, intensive care unit (ICU) readmission, prolonged ICU stay (>48 hours), prolonged need for vasopressors (>24 hours), resuscitation or death). RESULTS A total of 290 patients, including 36 patients with complications, was analyzed. Early TnT levels (odds ratio (OR): 6.8, 95% confidence interval (CI): 2.2-21.4, P=.001), logistic EuroSCORE (OR: 1.2, 95%CI: 1.0-1.3, P=.007) and the need for vasopressors during the first 6 postoperative hours (OR: 2.7, 95%CI: 1.0-7.1, P=.05) were independently associated with the risk of complications. With consideration of vasopressor use during the first 6 postoperative hours, the sum of specificity (0.958) and sensitivity (0.417) of TnT for subsequent complications was highest at a TnT cut-off value of 0.8 ng/mL. CONCLUSION Early TnT levels may be useful to guide ICU management of CABG patients. They predict clinically relevant complications within a potential therapeutic window, particularly in patients requiring vasopressors during the first postoperative hours, although with only moderate sensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS The aim of this prospective multinational registry is to assess and identify predictors of in-hospital outcome and complications of contemporary TAVI practice. METHODS AND RESULTS The Transcatheter Valve Treatment Sentinel Pilot Registry is a prospective independent consecutive collection of individual patient data entered into a web-based case record form (CRF) or transferred from compatible national registries. A total of 4,571 patients underwent TAVI between January 2011 and May 2012 in 137 centres of 10 European countries. Average age was 81.4±7.1 years with equal representation of the two sexes. Logistic EuroSCORE (20.2±13.3), access site (femoral approach: 74.2%), type of anaesthesia and duration of hospital stay (9.3±8.1 days) showed wide variations among the participating countries. In-hospital mortality (7.4%), stroke (1.8%), myocardial infarction (0.9%), major vascular complications (3.1%) were similar in the SAPIEN XT and CoreValve (p=0.15). Mortality was lower in transfemoral (5.9%) than in transapical (12.8%) and other access routes (9.7%; p<0.01). Advanced age, high logistic EuroSCORE, pre-procedural ≥grade 2 mitral regurgitation and deployment failure predicted higher mortality at multivariate analysis. CONCLUSIONS Increased operator experience and the refinement of valve types and delivery catheters may explain the lower rate of mortality, stroke and vascular complications than in historical studies and registries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Peri-procedural bleeding complications are feared adverse events in patients undergoing transcatheter aortic valve implantation (TAVI). Little is known about the implications of peri-procedural bleeding on clinical outcome. In a prospective single-center registry of consecutive patients undergoing TAVI, we investigated incidence, predictors and clinical consequences of life-threatening and major bleeding as defined by the Valve Academic Research Consortium. Among 389 consecutive patients undergoing TAVI by a transfemoral (79.2%), transapical (19.6%) or trans-subclavian (1.3%) approach between July 2007 and October 2011, life-threatening or major peri-procedural bleeding events occurred in 64 (16.4%) and 125 patients (32.1%), respectively. Patients with peri-procedural bleeding events had a higher logistic EuroSCORE, more advanced renal disease, and were more symptomatic as assessed by New York Heart Association functional class at baseline as compared to patients with no bleeding. Life-threatening bleeding was associated with a higher all-cause (17.2 vs. 5.6 vs. 3.0%, p < 0.001) and cardiovascular mortality (10.9 vs. 5.6 vs. 2.5%, p = 0.02) at 30 days compared to patients with major bleeding or no bleeding. Multivariate analysis identified transapical access (OR 2.6, 95% CI 1.4-4.8; p = 0.002), glomerular filtration rate <30 ml/min (OR 2.3, 95% CI 1.1-4.7, p = 0.031), and diabetes (OR 1.8, 95% CI 1.001-3.2, p = 0.049) as independent predictors of life-threatening, peri-procedural bleeding. Life-threatening bleeding complications in patients undergoing TAVI are associated with increased mortality. Renal impairment, diabetes, and transapical approach were identified as independent risk factors for life-threatening bleeding events.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To analyse the results after elective open total aortic arch replacement. METHODS We analysed 39 patients (median age 63 years, median logistic EuroSCORE 18.4) who underwent elective open total arch replacement between 2005 and 2012. RESULTS In-hospital mortality was 5.1% (n = 2) and perioperative neurological injury was 12.8% (n = 5). The indication for surgery was degenerative aneurysmal disease in 59% (n = 23) and late aneurysmal formation following previous surgery of type A aortic dissection in 35.9% (n = 14); 5.1% (n = 2) were due to anastomotical aneurysms after prior ascending repair. Fifty-nine percent (n = 23) of the patients had already undergone previous proximal thoracic aortic surgery. In 30.8% (n = 12) of them, a conventional elephant trunk was added to total arch replacement, in 28.2% (n = 11), root replacement was additionally performed. Median hypothermic circulatory arrest time was 42 min (21-54 min). Selective antegrade cerebral perfusion was used in 95% (n = 37) of patients. Median follow-up was 11 months [interquartile range (IQR) 1-20 months]. There was no late death and no need for reoperation during this period. CONCLUSIONS Open total aortic arch replacement shows very satisfying results. The number of patients undergoing total arch replacement as a redo procedure and as a part of a complex multisegmental aortic pathology is high. Future strategies will have to emphasize neurological protection in extensive simultaneous replacement of the aortic arch and adjacent segments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND There is great variability for the type of anaesthesia used during TAVI, with no clear consensus coming from comparative studies or guidelines. We sought to detect regional differences in the anaesthetic management of patients undergoing transcatheter aortic valve implantation (TAVI) in Europe and to evaluate the relationship between type of anaesthesia and in-hospital and 1year outcome. METHODS Between January 2011 and May 2012 the Sentinel European TAVI Pilot Registry enrolled 2807 patients treated via a transfemoral approach using either local (LA-group, 1095 patients, 39%) or general anaesthesia (GA-group, 1712 patients, 61%). RESULTS A wide variation in LA use was evident amongst the 10 participating countries. The use of LA has increased over time (from a mean of 37.5% of procedures in the first year, to 57% in last 6months, p<0.01). MI, major stroke as well as in-hospital death rate (7.0% LA vs 5.3% GA, p=0.053) had a similar incidence between groups, confirmed in multivariate regression analysis after adjusting for confounders. Dividing our population in tertiles according to the Log-EuroSCORE we found similar mortality under LA, whilst mortality was higher in the highest risk tertile under GA. Survival at 1year, compared by Kaplan-Meier analysis, was similar between groups (log-rank: p=0.1505). CONCLUSIONS Selection of anaesthesia appears to be more influenced by national practice and operator preference than patient characteristics. In the absence of an observed difference in outcomes for either approach, there is no compelling argument to suggest that operators and centres should change their anaesthetic practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The use of transcatheter mitral valve repair (TMVR) has gained widespread acceptance in Europe, but data on immediate success, safety, and long-term echocardiographic follow-up in real-world patients are still limited. OBJECTIVES The aim of this multinational registry is to present a real-world overview of TMVR use in Europe. METHODS The Transcatheter Valve Treatment Sentinel Pilot Registry is a prospective, independent, consecutive collection of individual patient data. RESULTS A total of 628 patients (mean age 74.2 ± 9.7 years, 63.1% men) underwent TMVR between January 2011 and December 2012 in 25 centers in 8 European countries. The prevalent pathogenesis was functional mitral regurgitation (FMR) (n = 452 [72.0%]). The majority of patients (85.5%) were highly symptomatic (New York Heart Association functional class III or higher), with a high logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) (20.4 ± 16.7%). Acute procedural success was high (95.4%) and similar in FMR and degenerative mitral regurgitation (p = 0.662). One clip was implanted in 61.4% of patients. In-hospital mortality was low (2.9%), without significant differences between groups. The estimated 1-year mortality was 15.3%, which was similar for FMR and degenerative mitral regurgitation. The estimated 1-year rate of rehospitalization because of heart failure was 22.8%, significantly higher in the FMR group (25.8% vs. 12.0%, p[log-rank] = 0.009). Paired echocardiographic data from the 1-year follow-up, available for 368 consecutive patients in 15 centers, showed a persistent reduction in the degree of mitral regurgitation at 1 year (6.0% of patients with severe mitral regurgitation). CONCLUSIONS This independent, contemporary registry shows that TMVR is associated with high immediate success, low complication rates, and sustained 1-year reduction of the severity of mitral regurgitation and improvement of clinical symptoms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre 'real-world' patient population in highly experienced centres. METHODS AND RESULTS Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. CONCLUSION The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES To report the mid-term results of aortic root replacement using a self-assembled biological composite graft, consisting of a vascular tube graft and a stented tissue valve. METHODS Between January 2005 and December 2011, 201 consecutive patients [median age 66 (interquartile range, IQR, 55-77) years, 31 female patients (15.4%), median logistic EuroSCORE 10 (IQR 6.8-23.2)] underwent aortic root replacement using a stented tissue valve for the following indications: annulo-aortic ectasia or ascending aortic aneurysm with aortic valve disease in 162 (76.8%) patients, active infective endocarditis in 18 (9.0%) and acute aortic dissection Stanford type A in 21 (10.4%). All patients underwent clinical and echocardiographic follow-up. We analysed survival and valve-related events. RESULTS The overall in-hospital mortality rate was 4.5%. One- and 5-year cardiac-related mortality rates were 3 and 6%, and overall survival was 95 ± 1.5 and 75 ± 3.6%, respectively. The rate of freedom from structural valve failure was 99% and 97 ± 0.4% at the 1- and 5-year follow-up, respectively. The incidence rates of prosthetic valve endocarditis were 3 and 4%, respectively. During a median follow-up of 28 (IQR 14-51) months, only 2 (1%) patients required valve-related redo surgery due to prosthetic valvular endocarditis and none suffered from thromboembolic events. One percent of patients showed structural valve deterioration without any clinical symptoms; none of the patients suffered greater than mild aortic regurgitation. CONCLUSIONS Aortic root replacement using a self-assembled biological composite graft is an interesting option. Haemodynamic results are excellent, with freedom from structured valve failure. Need for reoperation is extremely low, but long-term results are necessary to prove the durability of this concept.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Coronary artery bypass grafting (CABG) using extracorporeal circulation (ECC) is still the gold standard. However, alternative techniques have been developed to avoid ECC and its potential adverse effects. These encompass minimal extracorporeal circulation (MECC) or off-pump coronary artery bypass grafting (OPCAB). However, the prevailing potential benefits when comparing MECC and OPCABG are not yet clearly established. METHODS In this retrospective study we investigated the potential benefits of MECC and OPCABG in 697 patients undergoing CABG. Of these, 555 patients had been operated with MECC and 142 off-pump. The primary endpoint was Troponin T level as an indicator for myocardial damage. RESULTS Study groups were not significantly different in general. However, patients undergoing OPCABG were significantly older (65.01 years ± 9.5 vs. 69.39 years ± 9.5; p value <0.001) with a higher Logistic EuroSCORE I (4.92% ± 6.5 vs. 5.88% ± 6.8; p value = 0.017). Operating off pump significantly reduced the need for intra-operative blood products (0.7% vs. 8.6%; p-value <0.001) and the length of stay in the intensive care unit (ICU) (2.04 days ± 2.63 vs. 2.76 days ± 2.79; p value <0.001). Regarding other blood values a significant difference could not be found in the adjusted calculations. The combined secondary endpoint, major cardiac or cerebrovascular events (MACCE), was equal in both groups as well. CONCLUSIONS Coronary artery bypass grafting using MECC or OPCABG are two comparable techniques with advantages for OPCABG regarding the reduced need for intra-operative blood products and shorter length of stay in the ICU. However serological values and combined endpoint MACCE did not differ significantly in both groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The Perceval (Sorin Group, Milan, Italy) is a self-anchoring sutureless aortic valve prosthesis. We report the short- to midterm results of combined aortic valve replacement (AVR) with concomitant procedures in elderly patients undergoing operation as part of 3 consecutive prospective multicenter European studies. METHODS From April 2007 to February 2013, 243 patients (mean age, 79.7 ± 5.1 years; female patients, 61%; median EuroSCORE, 9%) underwent AVR with concomitant procedures. The concomitant procedures were coronary artery bypass grafting (CABG) (182 cases), septal myectomy (21 cases), CABG + other procedures (18 cases), and 22 other procedures. Primary and secondary end points included implant feasibility and safety (for mortality and morbidity) and efficacy (New York Heart Association [NYHA] class improvement and hemodynamic results) of the prosthesis at the different follow-up periods. Data were expressed as mean ± standard deviation. Kaplan-Meier analysis was performed for survival analysis. RESULTS Mean aortic cross-clamp and extracorporeal circulation (ECC) times were 50.7 ± 22.8 minutes and 78.9 ± 32.3 minutes, respectively. Thirty-day mortality was 2.1%. Mean postoperative gradient and effective orifice area were 10.1 ± 4.7 mm Hg and 1.5 ± 0.4 cm(2) and 8.9 ± 5.6 mm Hg and 1.6 ± 0.4 cm(2), respectively, at 1 year. There were early explantations, 4 of which resulted from paravalvular leaks. One additional valve explantation resulted from aortic root bleeding, probably caused by excessively extensive decalcification. In the late period, there was 1 mild paravalvular leak and no intravalvular insufficiency. No migration, dislodgement, or degeneration of the valve occurred during follow-up. Median follow-up was 444 days. CONCLUSIONS These trials confirm the safety and efficacy of the Perceval sutureless aortic valve, especially in elderly patients requiring AVR + concomitant procedures. In this patient group, sutureless valves may be advantageous compared to transcatheter valve implantations as concomitant procedures other than percutaneous coronary artery angioplasty are not always possible in the latter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The aim of the Cavalier trial was to evaluate the safety and performance of the Perceval sutureless aortic valve in patients undergoing aortic valve replacement (AVR). We report the 30-day clinical and haemodynamic outcomes from the largest study cohort with a sutureless valve. METHODS From February 2010 to September 2013, 658 consecutive patients (mean age 77.8 years; 64.4% females; mean logistic EuroSCORE 10.2%) underwent AVR in 25 European Centres. Isolated AVRs were performed in 451 (68.5%) patients with a less invasive approach in 219 (33.3%) cases. Of the total, 40.0% were octogenarians. Congenital bicuspid aortic valve was considered an exclusion criterion. RESULTS Implantation was successful in 628 patients (95.4%). In isolated AVR through sternotomy, the mean cross-clamp time and the cardiopulmonary bypass (CPB) time were 32.6 and 53.7 min, and with the less invasive approach 38.8 and 64.5 min, respectively. The 30-day overall and valve-related mortality rates were 3.7 and 0.5%, respectively. Valve explants, stroke and endocarditis occurred in 0.6, 2.1 and in 0.1% of cases, respectively. Preoperative mean and peak pressure gradients decreased from 44.8 and 73.24 mmHg to 10.24 and 19.27 mmHg at discharge, respectively. The mean effective orifice area improved from 0.72 to 1.46 cm(2). CONCLUSIONS The current 30-day results show that the Perceval valve is safe (favourable haemodynamic effect and low complication rate), and can be implanted with a fast and reproducible technique after a short learning period. Short cross-clamp and CPB times were achieved in both isolated and combined procedures. The Perceval valve represents a promising alternative to biological AVR, especially with a less invasive approach and in older patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This report summarizes the 5-year clinical and haemodynamic data from three prospective, European multicentre trials with the Perceval sutureless aortic valve. METHODS From April 2007 to August 2012, 731 consecutive patients (mean age: 78.5 years; 68.1% females; mean logistic EuroSCORE 10.9%) underwent AVR with the Perceval valve in 25 European centres. Isolated AVR was performed in 498 (68.1%) patients. A minimally invasive approach was performed in 189 (25.9%) cases. The cumulative follow-up was 729 patients-years. RESULTS In isolated AVR, mean cross-clamp and cardiopulmonary bypass times were 30.8 and 50.8 min in full sternotomy, and 37.6 and 64.4 min in the minimally invasive approach, respectively. Early cardiac-related deaths occurred in 1.9%. Overall survival rates at 1 and 5 years were 92.1 and 74.7%, respectively. Major paravalvular leak occurred in 1.4% and 1% at early and late follow-up, respectively. Significant improvement in clinical status was observed postoperatively in the majority of patients. Mean and peak gradients decreased from 42.9 and 74.0 mmHg preoperatively, to 7.8 and 16 mmHg at the 3-year follow-up. LV mass decreased from 254.5 to 177.4 g at 3 years. CONCLUSIONS This European multicentre experience, with the largest cohort of patients with sutureless valves to date, shows excellent clinical and haemodynamic results that remain stable even up to the 5-year follow-up. Even in this elderly patient cohort with 40% octogenarians, both early and late mortality rates were very low. There were no valve migrations, structural valve degeneration or valve thrombosis in the follow-up. The sutureless technique is a promising alternative to biological aortic valve replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).