986 resultados para Equipamento


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nas últimas décadas, a prospecção por métodos eletromagnéticos vem-se constituindo numa técnica eficiente para prospecção mineral. O objetivo deste trabalho foi desenvolver um equipamento para prospecção eletromagnética quantitativa de corpos condutores, através do método dipolo-dipolo, podendo ainda ser usado em modelos reduzidos. Eletricamente, o sistema mede grandezas relacionadas ao acoplamento indutivo entre duas bobinas: transmissora e receptora. Elas são dispostas na superfície da terra, afastadas entre si, e a terra, desse modo, constitui o núcleo acoplador. Quando existem corpos condutores nas proximidades, estes são denunciados por alterações no comportamento do sinal induzido na bobina receptora. O equipamento compreende dois conjuntos: o transmissor e o receptor, além de acessórios. O transmissor gera um campo eletromagnético nas freqüências de 520 e 3.090 Hz, e um sinal de referência para o receptor, o qual é enviado através de um cabo. O receptor, inicialmente, separa o sinal induzido pelos campos secundários gerados por condutores, do campo normalmente recebido, quando a condutividade da subsuperfície é relativamente uniforme (campo primário). Em seguida, decompõe esse sinal em duas componentes ortogonais, uma em fase, e outra em quadratura com o campo primário. Através de duas escalas de precisão, as amplitudes dessas componentes são mostradas como percentagens do campo primário, com precisão de 1%. A sensibilidade do receptor é de 0,5 μV. O circuito eletrônico foi rigorosamente testado com preciso instrumental de laboratório. Em seguida, testou-se sua aplicação no Laboratório de Modelo Reduzido Eletromagnético do NCGG, refazendo-se experiências clássicas, encontradas na literatura especializada. No campo, foi experimentado próximo da cidade de Araci no Estado da Bahia, em áreas prospectadas pela "Rio Doce Geologia e Mineração S/A-DOCEGEO". Em ambos os casos, verificaram-se bons resultados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente invenção se refere a um equipamento emissor de laser ou LED (diodo emissor de luz) e a um processo utilizando o referido equipamento em conjunto com totossensibilizadores específicos. O referido processo, bem como o equipamento, são utilizados para realizar o controle biológico do microrganismo Pythium spp.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Processo e equipamento de determinacão de desgaste de resinas compostas. O primeiro compreendido pelas etapas de: revestir uma superfície fixa com a resina a ser analisada, definindo uma camada superficial de resina a ser submetida a pressão dinâmica...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the coverage of spray droplets on coffee plants as well as their deposition using a sprayer with and without adaptation of an auxiliary branch for tall plants. The experiment was conducted following a randomized block design with six treatments and four replications to evaluate the percentage of coverage for the spraying liquids in water sensitive paper fixed at four quadrants and two heights (lower and upper) of the plants, and the spray deposit with metallic marker (MnSO4) on sheets in the same positions of the water sensitive paper in two spray volumes (450 and 750 L h(-1)). The experiment was conducted in October 2011 in the town of Patroc nio-MG, and the experimental plots consisted of 30 plants of Catua IAC-99, with approximately 12 years of age and average height of 3.50 meters. The experiments were conducted following a randomized block design with six treatments and four replications to evaluate the coverage and deposition, in two spray volumes (450 and 750 L ha(-1)). Leaves were collected in four positions and also at the top four in the lower canopy. The results of the evaluations were analysed statistically by F test and for comparison of means by Tukey test at 5% probability. The auxiliary branch installed at the rear of the equipment is the most suitable when compared to use of equipment without this feature or installed in the front of the equipment. Furthermore, the application volume of 450 L ha(-1) results in coverages and deposits of spraying liquids equivalents to volume of 750 L ha(-1), considered sufficient according to the parameters evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Almost forty years computed tomography (CT) has been one of the most powerful tools in diagnostic imaging. However, this modality delivers relatively high doses to their patients. It is known that the inappropriate use and unnecessary radiation may be associated with a significant risk of cancer, especially in pediatric patients. Moreover, the quality assurance in CT, provided and required by Portaria 453/98 and the guide of the RE 1016/05, ensures that the images generated by computer tomography provide reliable diagnostic information with doses as low as reasonably achievable. This research aimed to make the quality control (QC) of CT equipment; establish a better relationship between dose and noise on the image to protocols of skull CT according to the study of optimization proposed in 2005 by Daros; and assess the dose distribution in different cranial organs for protocols of adult and pediatric use in the routine of the Department of Diagnostic Imaging of HCFMB-UNESP. The equipment used for testing QC, optimization and dosimetry was a third generation tomograph GE Sytec 3000i

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, there is a need for improvements in production processes for companies to be competitive, as it is an obligation of businesses, it is necessary to know about the production processes accurately, to learn where improvements in work and thus have large impacts results. The calculation of efficiency of production lines is necessary to know as much about the progress of production and for product costing, when the measurement is not suitable, it generates negative impacts on the company. Due to the impact generated by this parameter, the graduation work carry out the study of change in a method that does not include all requirements necessary, by another method known as Overall Equipment Effectiveness, and according to studies, covering various parameters, showing become more consistent. These values are contained in the pattern production which is used to fund the product, thereby also occur financial impacts. Thus the work will study the change along with the analysis of impacts caused by the change