967 resultados para Energy-output Linkages


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diet digestibility and rate of passage, eating and rumination behavior, dry matter intake (DMI), and lactation performance were compared in 6 Jersey and 6 Holstein multiparous cows. Cows were fed gestation diets according to body weight (BW) beginning 7 wk before expected calving and ad libitum amounts of a lactation diet postpartum. Diet digestibility and rate of passage were measured in 5-d periods at wk 5 prepartum and wk 6 and 14 of lactation. Eating and ruminating behavior was measured over 5-d periods at wk 5 and 2 prepartum and wk 2, 6, 10, and 14 of lactation. Milk yield and DMI were higher in Holsteins, but milk energy output per kilogram of metabolic BW (BW0.75) and intake capacity (DMI/kg of BW) did not differ between breeds. Holsteins spent longer ruminating per day compared with Jerseys, but daily eating time did not differ between breeds. Jerseys spent more time eating and ruminating per unit of ingested feed. The duration and number of meals consumed did not differ between breeds, but the meals consumed by Jerseys were distributed more evenly throughout each 24-h period, providing a more regular supply of feed to the rumen. Feed passed through the digestive tract more quickly in Jerseys compared with Holsteins, suggesting particle breakdown and rumen outflow were faster in Jerseys, but this may also reflect the relative size of their digestive tract. Neutral detergent fiber digestibility was greater in Jerseys, despite the shorter rumen retention time, but digestibility of dry matter, organic matter, starch, and N did not differ between breeds. Utilization of digested N for tissue retention was higher at wk 5 prepartum and lower at wk 14 of lactation in Jerseys. In contrast to numerous published studies, intake capacity of Jerseys was not higher than that of Holsteins, but in the present study, cows were selected on the basis of equal expected milk energy yield per kilogram of metabolic BW. Digestibility of neutral detergent fiber and rate of digesta passage were higher in Jerseys, probably as a consequence of increased mastication per unit of feed consumed in Jerseys and their smaller size.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study investigated possible relationships between measurements of the somatotrophic axis in pre-pubertal dairy calves and subsequent milk yields. Endogenous growth hormone (GH) release was measured through a fed and fasted period in fifty 6-month-old Holstein-Friesian heifers and they were then challenged with growth hormone-releasing factor (GRF) to assess their GH release pattern. Insulin-like growth factor-I (IGF-I), insulin and glucose concentrations were measured in relation to time of feeding. Cows were subsequently monitored through their first three lactations to record peak and 305-day milk yields. In the first lactation, milk energy output for the first 120 days of lactation was also calculated. The mean 305-day milk yield increased from 7417 +/- 191 kg in the first lactation (n = 37) to 8749 +/- 252 kg in the third (n = 25). There were no significant relationships between any measures of GH secretion and peak or 305-day yield in any lactation. A highly significant positive relationship was established between the GH peak measured 10 min post-GRF challenge and 120-day milk energy values in the first lactation. This relationship was, however, only present in the subpopulation of 12 cows culled after one or two lactations and was absent in the 25 animals remaining for the third lactation. There were no significant relationships between pre-pubertal IGF-I and fed or fasted insulin or glucose concentrations and any subsequent measurement of yield. The usefulness of GH secretagogue challenges in calves as a predictive test for future milk production is thus limited but may have some bearing on nutrient partitioning and longevity. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The diffusion of Concentrating Solar Power Systems (CSP) systems is currently taking place at a much slower pace than photovoltaic (PV) power systems. This is mainly because of the higher present cost of the solar thermal power plants, but also for the time that is needed in order to build them. Though economic attractiveness of different Concentrating technologies varies, still PV power dominates the market. The price of CSP is expected to drop significantly in the near future and wide spread installation of them will follow. The main aim of this project is the creation of different relevant case studies on solar thermal power generation and a comparison betwwen them. The purpose of this detailed comparison is the techno-economic appraisal of a number of CSP systems and the understanding of their behaviour under various boundary conditions. The CSP technologies which will be examined are the Parabolic Trough, the Molten Salt Power Tower, the Linear Fresnel Mirrors and the Dish Stirling. These systems will be appropriatly sized and simulated. All of the simulations aim in the optimization of the particular system. This includes two main issues. The first is the achievement of the lowest possible levelized cost of electricity and the second is the maximization of the annual energy output (kWh). The project also aims in the specification of these factors which affect more the results and more specifically, in what they contribute to the cost reduction or the power generation. Also, photovoltaic systems will be simulated under same boundary conditions to facolitate a comparison between the PV and the CSP systems. Last but not leats, there will be a determination of the system which performs better in each case study.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A common problem when planning large free field PV-plants is optimizing the ground occupation ratio while maintaining low shading losses. Due to the complexity of this task, several PV-plants have been built using various configurations. In order to compare the shading losses of different PV technologies and array designs, empirical performance data of five free field PV-plants operating in Germany was analyzed. The data collected comprised 140 winter days from October 2011 until March 2012. The relative shading losses were estimated by comparing the energy output of selected arrays in the front rows (shading-free) against that of shaded arrays in the back rows of the same plant. The results showed that landscape mounting with mc-Si PV-modules yielded significantly better results than portrait one. With CIGS modules, making cross-table strings using the lower modules was not beneficial as expected and had more losses than a one-string-per-table layout. Parallel substrings with CdTe showed relatively low losses. Among the two CdTe products analyzed, none showed a significantly better performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV and solar thermal collectors by producing heat and electricity simultaneously. In this paper, the electrical performance evaluation of a low concentrating PVT collector was done through two testing parts: power comparison and performance ratio testing. For the performance ratio testing, it is required to identify and measure the factors affecting the performance ratio on a low concentrating PVT collector. Factors such as PV cell configuration, collector acceptance angle, flow rate, tracking the sun, temperature dependence and diffuse to irradiance ratio. Solarus low concentrating PVT collector V12 was tested at Dalarna University in Sweden using the electrical equipment at the solar laboratory. The PV testing has showed differences between the two receivers. Back2 was producing 1.8 energy output more than Back1 throughout the day. Front1 and Front2 were almost the same output performance. Performance tests showed that the cell configuration for Receiver2 with cells grouping (6- 32-32-6) has proved to have a better performance ratio when to it comes to minimizing the shading effect leading to more output power throughout the day because of lowering the mismatch losses. Different factors were measured and presented in this thesis in chapter 5. With the current design, it has been obtained a peak power at STC of 107W per receiver. The solar cells have an electrical efficiency of approximately 19% while the maximum measured electrical efficiency for the collector was approximately 18 % per active cell area, in addition to a temperature coefficient of -0.53%/ ˚C. Finally a recommendation was done to help Solarus AB to know how much the electrical performance is affected during variable ambient condition and be able to use the results for analyzing and introducing new modification if needed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A tool for standardized calculation of solar collector performance has been developed in cooperation between SP Technical Research Institute of Sweden, DTU Denmark and SERC Dalarna University. The tool is designed to calculate the annual performance of solar collectors at representative locations in Europe. The collector parameters used as input in the tool are compiled from tests according to EN12975, without any intermediate conversions. The main target group for this tool is test institutes and certification bodies that are intended to use it for conversion of collector model parameters (derived from performance tests) into a more user friendly quantity: the annual energy output. The energy output presented in the tool is expressed as kWh per collector module. A simplified treatment of performance for PVT collectors is added based on the assumption that the thermal part of the PVT collector can be tested and modeled as a thermal collector, when the PV electric part is active with an MPP tracker in operation. The thermal collector parameters from this operation mode are used for the PVT calculations. © 2012 The Authors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this project is to verify whether anaerobic reactors applied to sewage treatment are energetically self-sufficient. This evaluation can be made by balancing the methane produced through the anaerobic transformation stages (hydrolysis, acidogenesis, acetogenesis and methanogenesis) and the reactor energy consumption requirements. The original project included methanogenic activity tests, which could not be performed due to setbacks in the installation of an analytical instrument. Scientific articles about bench- and full-scale anaerobic reactors were investigated instead. An average substrate-to-methane conversion efficiency of 58,2±18,6% was found for the bench-scale reactors and higher efficiencies (89,2%) were found for the cases which had higher Organic Loading Rates (OLRs) values. The average energy output was 0,013 kWh/Lsewage, value unable to meet the energy needs for the reactor operation, considering equipments normally used such as temperature controller. This balance can become positive if few hypotheses are made, for example (i) to eliminate the use of temperature controller (ii) to alter the operation pattern from continuous to intermittent. Based on energy balance assessment of eight bench-scale reactors, it was observed that the implementation of a system for biogas utilization is not energetically feasible. However, interesting results were found for a full-scale sewage treatment plant, ETE Ouro Verde – Foz do Iguaçu, PR, Brazil. Even though its substrate-tomethane conversion efficiency was about 10% only, the energy balance was quite positive, with energy consumption of 68 kWh/month and energy production of 660 kWh/month. This analysis leads us to conclude that energy recovery from full-scale sewage treatment plants should be practiced by other plants

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to account the energy balance of six different farming systems: CMT (minimum tillage with transgenic corn); CMNT (minimum tillage with non-transgenic corn); PCT (conventional tillage with transgenic corn); PCNT (conventional tillage with non-transgenic corn); PDT (no-tillage system with transgenic corn) and PDNT (no-tillage system with non-transgenic corn). The study was carried out at the Experimental Farm Lageado FCA/Unesp, Botucatu - SP. The energy balance was performed by subtracting the total energy inputs by the total energy output. Energy efficiency was calculated by dividing the total energy output by the total energy inputs. The total values ​​of energy inputs and outputs were expressed in MJ.ha-1 (mega joules per hectare). To calculate the energy inputs were accounted the fuel consumption and lubricants, depreciation energy of machinery and implements, manpower and agricultural inputs. The energy outputs were calculated according to the maize yield. The result shows that the system PDT was the system that had better energy efficiency and the system that had the lowest efficiency was the PCT system. The system with lower energy demand was the PDT and the greatest demand was PCNT.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study, organic coffee production systems energy efficiency was estimate. So, an itinerary technical was built since the deployment phase up to the organic coffee production. The inputs used (labor, machine hours, pesticides, fertilizers, etc.) converted into energy units, quantified the energy input, while the production of organic coffee beans benefited was constituted the energy output. Data collection was based on an intentional and non-probabilistic sampling. Nine farmers were interviewed whose main source of income was the coffee production and had keep records of the culture data. The balances were positive, with an energy yield of 626.465MJ.ha-1, compared to an energy expenditure of 112.998MJ.ha-1 during the crop cycle. It is concluded that organic coffee production is energy efficient.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The ability to represent the transport and fate of an oil slick at the sea surface is a formidable task. By using an accurate numerical representation of oil evolution and movement in seawater, the possibility to asses and reduce the oil-spill pollution risk can be greatly improved. The blowing of the wind on the sea surface generates ocean waves, which give rise to transport of pollutants by wave-induced velocities that are known as Stokes’ Drift velocities. The Stokes’ Drift transport associated to a random gravity wave field is a function of the wave Energy Spectra that statistically fully describe it and that can be provided by a wave numerical model. Therefore, in order to perform an accurate numerical simulation of the oil motion in seawater, a coupling of the oil-spill model with a wave forecasting model is needed. In this Thesis work, the coupling of the MEDSLIK-II oil-spill numerical model with the SWAN wind-wave numerical model has been performed and tested. In order to improve the knowledge of the wind-wave model and its numerical performances, a preliminary sensitivity study to different SWAN model configuration has been carried out. The SWAN model results have been compared with the ISPRA directional buoys located at Venezia, Ancona and Monopoli and the best model settings have been detected. Then, high resolution currents provided by a relocatable model (SURF) have been used to force both the wave and the oil-spill models and its coupling with the SWAN model has been tested. The trajectories of four drifters have been simulated by using JONSWAP parametric spectra or SWAN directional-frequency energy output spectra and results have been compared with the real paths traveled by the drifters.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper details an investigation into the appearance of hot-spots in two large grid-connected photovoltaics (PV) plants, which were detected after the visual inspection of trackers whose energy output was decreasing at anomalous rate. Detected hot-spots appeared not only in the solar cells but also in resistive solder bonds (RSB) between cells and contact ribbons. Both types cause similar irreversible damage to the PV modules, but the latter are the main responsible for the detected decrease in energy output, which was confirmed in an experimental testing campaign. The results of this investigation, for example, how hot-spots were detected or their impact on the output power of PV modules, may be of interest for the routine maintenance of large grid-connected PV plants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BIPV systems are small PV generation units spread out over the territory, and whose characteristics are very diverse. This makes difficult a cost-effective procedure for monitoring, fault detection, performance analyses, operation and maintenance. As a result, many problems affecting BIPV systems go undetected. In order to carry out effective automatic fault detection procedures, we need a performance indicator that is reliable and that can be applied on many PV systems at a very low cost. The existing approaches for analyzing the performance of PV systems are often based on the Performance Ratio (PR), whose accuracy depends on good solar irradiation data, which in turn can be very difficult to obtain or cost-prohibitive for the BIPV owner. We present an alternative fault detection procedure based on a performance indicator that can be constructed on the sole basis of the energy production data measured at the BIPV systems. This procedure does not require the input of operating conditions data, such as solar irradiation, air temperature, or wind speed. The performance indicator, called Performance to Peers (P2P), is constructed from spatial and temporal correlations between the energy output of neighboring and similar PV systems. This method was developed from the analysis of the energy production data of approximately 10,000 BIPV systems located in Europe. The results of our procedure are illustrated on the hourly, daily and monthly data monitored during one year at one BIPV system located in the South of Belgium. Our results confirm that it is possible to carry out automatic fault detection procedures without solar irradiation data. P2P proves to be more stable than PR most of the time, and thus constitutes a more reliable performance indicator for fault detection procedures. We also discuss the main limitations of this novel methodology, and we suggest several future lines of research that seem promising to improve on these procedures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Shading reduces the power output of a photovoltaic (PV) system. The design engineering of PV systems requires modeling and evaluating shading losses. Some PV systems are affected by complex shading scenes whose resulting PV energy losses are very difficult to evaluate with current modeling tools. Several specialized PV design and simulation software include the possibility to evaluate shading losses. They generally possess a Graphical User Interface (GUI) through which the user can draw a 3D shading scene, and then evaluate its corresponding PV energy losses. The complexity of the objects that these tools can handle is relatively limited. We have created a software solution, 3DPV, which allows evaluating the energy losses induced by complex 3D scenes on PV generators. The 3D objects can be imported from specialized 3D modeling software or from a 3D object library. The shadows cast by this 3D scene on the PV generator are then directly evaluated from the Graphics Processing Unit (GPU). Thanks to the recent development of GPUs for the video game industry, the shadows can be evaluated with a very high spatial resolution that reaches well beyond the PV cell level, in very short calculation times. A PV simulation model then translates the geometrical shading into PV energy output losses. 3DPV has been implemented using WebGL, which allows it to run directly from a Web browser, without requiring any local installation from the user. This also allows taken full benefits from the information already available from Internet, such as the 3D object libraries. This contribution describes, step by step, the method that allows 3DPV to evaluate the PV energy losses caused by complex shading. We then illustrate the results of this methodology to several application cases that are encountered in the world of PV systems design. Keywords: 3D, modeling, simulation, GPU, shading, losses, shadow mapping, solar, photovoltaic, PV, WebGL

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Desde el siglo VIII hasta prácticamente el siglo XX, los molinos de marea han sido una fuente de desarrollo de las zonas en las que estaban implantados. En toda la costa atlántica de Europa, y posteriormente en América, se desarrollaron estos ingenios conectados por su naturaleza con los puertos. En ellos se procesaban materia prima que tenía su origen o destino en dichos puertos. La aparición de otras fuentes de energía más económicas y eficaces supuso la decadencia paulatina de estos ingenios, hasta la práctica desaparición de un buen número de ellos. En los últimos años, tanto instituciones privadas como públicas, especialmente ayuntamientos han mostrado un interés en conservar estos ingenios ya sea como edificación singular en el que se desarrollen distintos negocios, o como museos o “centros de interpretación” en los que se explica el funcionamiento del molino y su relación con la comarca de influencia. Este nuevo interés por el tema, unido a la necesidad de buscar nuevas fuentes de energías renovables para dar cumplimento a las condiciones del Tratado de Kyoto motivan la necesidad de un estudio de la aplicación de la energía minihidráulica a los antiguos molinos. En el presente documento se ha procedido en primer lugar a describir la historia de los molinos de marea y a continuación a localizarlos en cada provincia para identificar los posibles puntos de producción de energía. Seguidamente se procedió a identificar los diferentes tipos de turbinas aplicables a estos casos, de los que se han elegido dos de ellos, uno de ellos consolidado y el otro en fase experimental, para determinar y analizar la tendencia de determinadas magnitudes financieras en función de la carrera de marea. Las conclusiones resultantes de este análisis han sido que el sistema de funcionamiento mediante el flujo de la marea es menos productivo que mediante reflujo y que la altura de marea en las costas españolas limita considerablemente la rentabilidad de la inversión. Esta circunstancia obliga a hacer un estudio de viabilidad muy detallado de cada uno de los casos. Las investigaciones futuras en este campo se deben encaminar hacia el desarrollo de un nuevo tipo de miniturbina con una mayor regulación para obtener un mayor rendimiento, teniendo en cuenta, además, que el estuario de un molino de marea puede ser además un excelente banco de pruebas. Por otro lado, la posible producción de energía puede ser un elemento a estudiar dentro de un sistema de generación distribuida en el ámbito de una smart-city. From the eighth century until practically the twentieth century, the tide mills have been a source of development of the areas in which they were implanted. Across the Atlantic coast of Europe, and subsequently in America, these devices were developed and connected by its nature with the nearby ports. In these places the raw material, with its origin and destination from these ports, were processed. The emergence of other sources of energy more economic and efficient caused the gradual decline of these devices which led to the disappearance of a large number of them. In recent years, both private and public institutions, especially municipalities, have shown interest in preserving these devices as singular buildings, or as museums or "visitor centers" where the process of milling is explained and also its relationship with the region of influence. This renewed interest in the subject, coupled with the need of finding new sources of renewable energy in order to comply with the conditions of the Kyoto Treaty, has created the need for a study of the possible implementation of small hydro power in the old mills. In the present document, first we have proceeded to describe the history of the tide mills and afterwards we have located them in the Spanish provinces to identify the possible locations of energy generation. In the next step, we proceeded to identify the different types of turbines suitable to these cases, and we have been selected two of them. The first one is consolidated and the second one is in an experimental phase. With these pair of turbines we have determined and analyzed the outcome of certain financial data depending on the tidal range. The conclusions drawn from this analysis are that operating the system by the flow tide is less productive than by ebb tide. The limited height of tide in the Spanish coast considerably limits the return on investment. This outcome forces potential investors to make a very detailed analysis of each case study. Future researches in this field should be guided towards the development of a new type of mini turbine with more regulation for a higher performance, taking into account also that the basin of a tidal mill can also be an excellent test place. Furthermore, the potential energy output can be a factor to consider in a distributed generation system within a smart city.