920 resultados para Electrostatic interpretation


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The exact description of the thermodynamics of solutions has been used to describe, without approximation, the distribution of all the components of an incompressible solution in a centrifuge cell at sedimentation equilibrium. Thermodynamic parameters describing the interactions between solute components of known molar mass can be obtained by direct analysis of the experimental data. Interpretation of the measured thermodynamic parameters in terms of molecular interactions requires that an arbitrary distinction be made between nonassociative forces, like hard-sphere volume-exclusion and mean-field electrostatic repulsion or attraction, and specific short-range forces of association that give rise to the formation of molecular aggregates. Provided the former can be accounted for adequately, the effects of the latter can be elucidated in the form of good estimates of the equilibrium constants for the reactions of aggregation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tissue Doppler may be used to quantify regional left ventricular function but is limited by segmental variation of longitudinal velocity from base to apex and free to septal walls. We sought to overcome this by developing a composite of longitudinal and radial velocities. Methods and Results. We examined 82 unselected patients undergoing a standard dobutamine echocardiogram. Longitudinal velocity was obtained in the basal and mid segments of each wall using tissue Doppler in the apical views. Radial velocities were derived in the same segments using an automated border detection system and centerline method with regional chords grouped according to segment location and temporally averaged. In 25 patients at low probability of coronary disease, the pattern of regional variation in longitudinal velocity (higher in the septum) was the opposite of radial velocity (higher in the free wall) and the combination was homogenous. In 57 patients undergoing angiography, velocity in abnormal segments was less than normal segments using longitudinal (6.0 +/- 3.6 vs 9.0 +/- 2.2 cm/s, P = .01) and radial velocity (6.0 +/- 4.0 vs 8.0 +/- 3.9 cm/s, P = .02). However, the composite velocity permitted better separation of abnormal and normal segments (13.3 +/- 5.6 vs 17.5 +/- 4.2 cm/s, P = .001). There was no significant difference between the accuracy of this quantitative approach and expert visual wall motion analysis (81% vs 84%, P = .56). Conclusion: Regional variation of uni-dimensional myocardial velocities necessitates site-specific normal ranges, probably because of different fiber directions. Combined analysis of longitudinal and radial velocities allows the derivation of a composite velocity, which is homogenous in all segments and may allow better separation of normal and abnormal myocardium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantification of stress echocardiography may overcome the training requirements and subjective nature of visual wall motion score (WMS) assessment, but quantitative approaches may be difficult to apply and require significant time for image processing. The integral of long-axis myocardial velocity is displacement, which may be represented as a color map over the left ventricular myocardium. This study was designed to explore the feasibility and accuracy of measuring long-axis myocardial displacement, derived from tissue Doppler, for the detection of coronary artery disease (CAD) during dobutamine stress echocardiography (DBE). One hundred thirty patients underwent standard DBE, including 30 patients at low risk of CAD, 30 patients with normal coronary angiography (both groups studied to define normal ranges of displacement), and 70 patients who underwent coronary angiography in whom the accuracy of normal ranges was tested. Regional myocardial displacement was obtained by analysis of color tissue Doppler apical images acquired at peak stress. Displacement was compared with WMS, and with the presence of CAD by angiography. The analysis time was 3.2 +/- 1.5 minutes per patient. Segmental displacement was correlated with wall motion (normal 7.4 +/- 3.2 mm, ischemia 5.8 +/- 4.2 mm, viability 4.6 +/- 3.0 mm, scar 4.5 +/- 3.5 mm, p <0.001). Reversal of normal base-apex displacement was an insensitive (19%) but specific (90%) marker of CAD. The sum of displacements within each vascular territory had a sensitivity and specificity of 89% and 79%, respectively, for prediction of significant CAD, compared with 86% and 78%, respectively, for WMS (p = NS). The displacements in the basal segments had a sensitivity and specificity of 83% and 78%, respectively (p = NS). Regional myocardial displacement during DBE is feasible and offers a fast and accurate method for the diagnosis of CAD. (C),2002 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To determine the degree of inter-institutional agreement in the assessment of dobutamine stress echocardiograms using modern stress echo cardiographic technology in combination with standardized data acquisition and assessment criteria. Method and Results Among six experienced institutions, 150 dobutamine stress echocardiograms (dobutamine up to 40 mug.kg(-1) min(-1) and atropine up to I mg) were performed on patients with suspected coronary artery disease using fundamental and harmonic imaging following a consistent digital acquisition protocol. Each dobutamine stress echocardiogram was assessed at every institution regarding endocardial visibility and left ventricular wall motion without knowledge of any other data using standardized reading criteria. No patients were excluded due to poor image quality or inadequate stress level. Coronary angiography was performed within 4 weeks. Coronary angiography demonstrated significant coronary artery disease (less than or equal to50% diameter stenosis) in 87 patients. Using harmonic imaging an average of 5.2+/-0.9 institutions agreed on dobutamine stress echocardiogram results as being normal or abnormal (mean kappa 0.55; 95% CI 0.50-0.60). Agreement was higher in patients with no (equal assessment of dobutamine stress echocardiogram results by 5.5 +/- 0.8 institutions) or three-vessel coronary artery disease (5.4 +/- 0.8 institutions) and lower in one- or two- vessel disease (5.0 +/- 0.9 and 5.2 +/- 1.0 institutions, respectively-, P=0.041). Disagreement on test results was greater in only minor wall motion abnormalities. Agreement on dobutamine stress echocardiogram results was lower using fundamental imaging (mean kappa 0.49; 95% CI 0.44-0.54; P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Brief Report presents a corollary to Uhlmann's theorem which provides a simple operational interpretation of the fidelity of mixed states.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of exchange of substances between blood and tissue has been a long-lasting challenge to physiologists, and considerable theoretical and experimental accomplishments were achieved before the development of the positron emission tomography (PET). Today, when modeling data from modern PET scanners, little use is made of earlier microvascular research in the compartmental models, which have become the standard model by which the vast majority of dynamic PET data are analysed. However, modern PET scanners provide data with a sufficient temporal resolution and good counting statistics to allow estimation of parameters in models with more physiological realism. We explore the standard compartmental model and find that incorporation of blood flow leads to paradoxes, such as kinetic rate constants being time-dependent, and tracers being cleared from a capillary faster than they can be supplied by blood flow. The inability of the standard model to incorporate blood flow consequently raises a need for models that include more physiology, and we develop microvascular models which remove the inconsistencies. The microvascular models can be regarded as a revision of the input function. Whereas the standard model uses the organ inlet concentration as the concentration throughout the vascular compartment, we consider models that make use of spatial averaging of the concentrations in the capillary volume, which is what the PET scanner actually registers. The microvascular models are developed for both single- and multi-capillary systems and include effects of non-exchanging vessels. They are suitable for analysing dynamic PET data from any capillary bed using either intravascular or diffusible tracers, in terms of physiological parameters which include regional blood flow. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Published mobility measurements obtained by capillary zone electrophoresis of human growth hormone peptides are described reasonably well by the classical theoretical relationships for electrophoretic migration. This conformity between theory and experiment has rendered possible a more critical assessment of a commonly employed empirical relationship between mobility (u), net charge (z) and molecular mass (M) of peptides in capillary electrophoresis. The assumed linear dependence between u and z/M-2/3 is shown to be an approximate description of a shallow curvilinear dependence convex to the abscissa. An improved procedure for the calculation of peptide charge (valence) is also described. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distance learners are self-directed learners traditionally taught via study books, collections of readings, and exercises to test understanding of learning packages. Despite advances in e-Learning environments and computer-based teaching interfaces, distance learners still lack opportunities to participate in exercises and debates available to classroom learners, particularly through non-text based learning techniques. Effective distance teaching requires flexible learning opportunities. Using arguments developed in interpretation literature, we argue that effective distance learning must also be Entertaining, Relevant, Organised, Thematic, Involving and Creative—E.R.O.T.I.C. (after Ham, 1992). We discuss an experiment undertaken with distance learners at The University of Queensland Gatton Campus, where we initiated an E.R.O.T.I.C. external teaching package aimed at engaging distance learners but using multimedia, including but not limited to text-based learning tools. Student responses to non-text media were positive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acetohydroxyacid synthase (AHAS, EC 4.1.3.18) catalyses the first step in branched-chain amino acid biosynthesis and is the target for sulfonylurea and imidazolinone herbicides, which act as potent and specific inhibitors. Mutants of the enzyme have been identified that are resistant to particular herbicides. However, the selectivity of these mutants towards various sulfonylureas and imidazolinones has not been determined systematically. Now that the structure of the yeast enzyme is known, both in the absence and presence of a bound herbicide, a detailed understanding of the molecular interactions between the enzyme and its inhibitors becomes possible. Here we construct 10 active mutants of yeast AHAS, purify the enzymes and determine their sensitivity to six sulfonylureas and three imidazolinones. An additional three active mutants were constructed with a view to increasing imidazolinone sensitivity. These three variants were purified and tested for their sensitivity to the imidazolinones only. Substantial differences are observed in the sensitivity of the 13 mutants to the various inhibitors and these differences are interpreted in terms of the structure of the herbicide-binding site on the enzyme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When the electrostatic spraying is used correctly, it provides advantages over conventional systems, however many factors can affect the system efficiency. Therefore, the objective of this study was to evaluate the charge/mass ratio (Q/M) at different spraying distances (0, 1, 2, 3, 4 and 5 m), and the liquid deposition efficiency on the target. Evaluating the Q/M ratio the Faraday cage method was used and to evaluate the liquid deposition efficiency the artificial targets were positioned longitudinally and transversely to the spray jet. It was found that the spraying distance affects the Q/M ratio, consequently, the liquid deposition efficiency. For the closest distance to the target the Q/M ratio was 4.11 mC kg-1, and at distances of 1, 2, 3, 4 and 5 m, the ratio decreased to 1.38, 0.64, 0.31, 0.17 and 0.005 mC kg-1, respectively. For the liquid deposition, the electrostatic system was affected by the target orientation and spraying distance. The target transversely to the jet of liquid did not improve the liquid deposition, but longitudinally increased the deposition up to 3 meters of distance.