897 resultados para Electromyography fatigue threshold


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Taste and smell detection threshold measurements are frequently time consuming especially when the method involves reversing the concentrations presented to replicate and improve accuracy of results. These multiple replications are likely to cause sensory and cognitive fatigue which may be more pronounced in elderly populations. A new rapid detection threshold methodology was developed that quickly located the likely position of each individuals sensory detection threshold then refined this by providing multiple concentrations around this point to determine their threshold. This study evaluates the reliability and validity of this method. Findings indicate that this new rapid detection threshold methodology was appropriate to identify differences in sensory detection thresholds between different populations and has positive benefits in providing a shorter assessment of detection thresholds. The results indicated that this method is appropriate at determining individual as well as group detection thresholds.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fatigue crack growth rate tests have been performed on Nimonic AP1, a powder formed Ni-base superalloy, in air and vacuum at room temperature. These show that threshold values are higher, and near-threshold (faceted) crack growth rates are lower, in vacuum than in air, although at high growth rates, in the “structure-insensitive” regime, R-ratio and a dilute environment have little effect. Changing the R-ratio from 0.1 to 0.5 in vacuum does not alter near-threshold crack growth rates very much, despite more extensive secondary cracking being noticeable at R= 0.5. In vacuum, rewelding occurs at contact points across the crack as ΔK falls. This leads to the production of extensive fracture surface damage and bulky fretting debris, and is thought to be a significant contributory factor to the observed increase in threshold values.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fatigue crack propagation and threshold data for two Ni-base alloys, Astroloy and Nimonic 901, are reported. At room temperature the effect which altering the load ratio (R-ratio) has on fatigue behaviour is strongly dependent on grain size. In the coarse grained microstructures crack growth rates increase and threshold values decrease markedly as R rises from 0. 1 to 0. 8, whereas only small changes in behaviour occur in fine grained material. In Astroloy, when strength level and gamma grain size are kept constant, there is very little effect of processing route and gamma prime distribution on room temperature threshold and crack propagation results. The dominant microstructural effect on this type of fatigue behaviour is the matrix ( gamma ) grain size itself.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fatigue crack growth properties of friction stir welded joints of 2024-T3 aluminium alloy have been studied under constant load amplitude (increasing-Delta K), with special emphasis on the residual stress (inverse weight function) effects on longitudinal and transverse crack growth rate predictions (Glinka`s method). In general, welded joints were more resistant to longitudinally growing fatigue cracks than the parent material at threshold Delta K values, when beneficial thermal residual stresses decelerated crack growth rate, while the opposite behaviour was observed next to K-C instability, basically due to monotonic fracture modes intercepting fatigue crack growth in weld microstructures. As a result, fatigue crack growth rate (FCGR) predictions were conservative at lower propagation rates and non-conservative for faster cracks. Regarding transverse cracks, intense compressive residual stresses rendered welded plates more fatigue resistant than neat parent plate. However, once the crack tip entered the more brittle weld region substantial acceleration of FCGR occurred due to operative monotonic tensile modes of fracture, leading to non-conservative crack growth rate predictions next to K-C instability. At threshold Delta K values non-conservative predictions values resulted from residual stress relaxation. Improvements on predicted FCGR values were strongly dependent on how the progressive plastic relaxation of the residual stress field was considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Little consensus exists in the literature regarding methods for determination of the onset of electromyographic (EMG) activity. The aim of this study was to compare the relative accuracy of a range of computer-based techniques with respect to EMG onset determined visually by an experienced examiner. Twenty-seven methods were compared which varied in terms of EMG processing (low pass filtering at 10, 50 and 500 Hz), threshold value (1, 2 and 3 SD beyond mean of baseline activity) and the number of samples for which the mean must exceed the defined threshold (20, 50 and 100 ms). Three hundred randomly selected trials of a postural task were evaluated using each technique. The visual determination of EMG onset was found to be highly repeatable between days. Linear regression equations were calculated for the values selected by each computer method which indicated that the onset values selected by the majority of the parameter combinations deviated significantly from the visually derived onset values. Several methods accurately selected the time of onset of EMG activity and are recommended for future use. Copyright (C) 1996 Elsevier Science Ireland Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Advances in surface electromyography (sEMG) techniques provide a clear indication that refinement of electrode location relative to innervation zones (IZ) is required in order to optimise the accuracy, relevance and repeatability of the sEMG signals. The aim of this study was to identify the IZ for the sternocleidomastoid and anterior scalene muscles to provide guidelines for electrode positioning for future clinical and research applications. Methods: Eleven volunteer subjects participated in this study. Myoelectric signals were detected from the sternal and clavicular heads of the stemocleidomastoid and the anterior scalene muscles bilaterally using a linear array of 8 electrodes during isometric cervical flexion contractions. The signals were reviewed and the IZ(s) were identified, marked on the subjects' skin and measurements were obtained relative to selected anatomical landmarks. Results: The position of the IZ lay consistently around the mid-point or in the superior portion of the muscles studied. Conclusions: Results suggest that electrodes should be positioned over the lower portion of the muscle and not the mid-point, which has been commonly used in previous studies. Recommendations for sensor placement on these muscles should assist investigators and clinicians to ensure improved validity in future sEMG applications. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study compares myoelectric manifestations of fatigue of the sternocleidomastoid (SCM) and anterior scalene (AS) muscles between 10 chronic neck pain subjects and 10 normal matched controls. Methods: Surface electromyography (sEMG) signals were recorded from the sternal bead of SCM and AS muscles bilaterally during submaximal isometric cervical flexion contractions at 25 and 50% of the maximum voluntary contraction (MVC). The mean frequency, average rectified value and conduction velocity of the sEMG signal were calculated to quantify myoelectric manifestations of muscle fatigue. Results: For both the SCM and AS muscles, the Mann-Whitney U test indicated that the initial value and slope of the mean frequency in neck pain patients were greater than in healthy subjects (P < 0.05). This was significant both at 25 and 50% of MVC. Conclusions: These results suggest: (a) a predominance of type-II fibres in the neck pain patients and/or (b) greater fatigability of the superficial cervical flexors in neck pain patients. These results are in agreement with previous muscle biopsy studies in subjects with neck pain, which identified transformation of slow-twitch type-I fibres to fast-twitch type-IIB fibres, as well as the clinical observation of reduced endurance in the cervical flexors in neck pain patients. (C) 2003 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to analyze the influence of position and pauses on muscle activity and fatigue during the task of ironing. Ten female participants performed the task of ironing in two different positions (standing and sitting) for 10 min each with a 1-min pause at the end of each task. Muscle activity and fatigue from the upper trapezium, anterior deltoid, and pectoralis major were analyzed using surface electromyography. The results showed that the positions had no significant influence on muscle activity; nevertheless, they had significant influence on muscular fatigue. In addition, the pauses were possibly beneficial in decreasing the muscle fatigue, but the results were not conclusive.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ergonomic interventions such as increased scheduled breaks or job rotation have been proposed to reduce upper limb muscle fatigue in repetitive low-load work. This review was performed to summarize and analyze the studies investigating the effect of job rotation and work-rest schemes, as well as, work pace, cycle time and duty cycle, on upper limb muscle fatigue. The effects of these work organization factors on subjective fatigue or discomfort were also analyzed. This review was based on relevant articles published in PubMed, Scopus and Web of Science. The studies included in this review were performed in humans and assessed muscle fatigue in upper limbs. 14 articles were included in the systematic review. Few studies were performed in a real work environment and the most common methods used to assess muscle fatigue were surface electromyography (EMG). No consistent results were found related to the effects of job rotation on muscle activity and subjective measurements of fatigue. Rest breaks had some positive effects, particularly in perceived discomfort. The increase in work pace reveals a higher muscular load in specific muscles. The duration of experiments and characteristics of participants appear to be the factors that most have influenced the results. Future research should be focused on the improvement of the experimental protocols and instrumentation, in order to the outcomes represent adequately the actual working conditions. Relevance to industry: Introducing more physical workload variation in low-load repetitive work is considered an effective ergonomic intervention against muscle fatigue and musculoskeletal disorders in industry. Results will be useful to identify the need of future research, which will eventually lead to the adoption of best industrial work practices according to the workers capabilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to analyze the influence of position and pauses on muscle activity and fatigue during the task of ironing. Ten female participants performed the task of ironing in two different positions (standing and sitting) for 10 min each with a 1-min pause at the end of each task. Muscle activity and fatigue from the upper trapezium, anterior deltoid, and pectoralis major were analyzed using surface electromyography. The results showed that the positions had no significant influence on muscle activity; nevertheless, they had significant influence on muscular fatigue. In addition, the pauses were possibly beneficial in decreasing the muscle fatigue, but the results were not conclusive.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the study was to test the hypothesis of the involvement of type II fibres in the V.O (2) slow component phenomenon by using two prior fatiguing protocols on the knee extensor muscles. Nine subjects performed three constant-load cycling exercises at a work rate corresponding to 80 % of their V.O (2) max: (i) preceded by a 20-min fatiguing protocol using electromyostimulation (EMS), (ii) preceded by a 20-min fatiguing protocol using voluntary contractions (VOL), and (iii) without fatiguing protocol (NFP). Voluntary and evoked neuromuscular properties of the knee extensor muscles were tested before (PRE) and after (POST) the two fatiguing protocols. Results show a significant reduction in voluntary force after both fatiguing protocols (-19.9 % and -11.8 %, in EMS and VOL, respectively p<0.01). After EMS, this decrease was greater than after VOL (p<0.05) and was combined with a slackening of muscle contractile properties which was absent after VOL (p<0.05). Regarding the effects on oxygen uptake kinetics, the appearance of the slow component was delayed after EMS and its amplitude was lower than those obtained in VOL and NFP conditions (0.48+/-0.07 vs. 0.75+/-0.09 and 0.69+/-0.08 L . min (-1), respectively; p<0.05). It can thus be concluded that exercises dedicated to preferentially fatiguing type II fibres may alter V.O (2) kinetics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This study investigated the isolated and combined effects of heat [temperate (22 °C/30 % rH) vs. hot (35 °C/40 % rH)] and hypoxia [sea level (FiO2 0.21) vs. moderate altitude (FiO2 0.15)] on exercise capacity and neuromuscular fatigue characteristics. METHODS: Eleven physically active subjects cycled to exhaustion at constant workload (66 % of the power output associated with their maximal oxygen uptake in temperate conditions) in four different environmental conditions [temperate/sea level (control), hot/sea level (hot), temperate/moderate altitude (hypoxia) and hot/moderate altitude (hot + hypoxia)]. Torque and electromyography (EMG) responses following electrical stimulation of the tibial nerve (plantar-flexion; soleus) were recorded before and 5 min after exercise. RESULTS: Time to exhaustion was reduced (P < 0.05) in hot (-35 ± 15 %) or hypoxia (-36 ± 14 %) compared to control (61 ± 28 min), while hot + hypoxia (-51 ± 20 %) further compromised exercise capacity (P < 0.05). However, the effect of temperature or altitude on end-exercise core temperature (P = 0.089 and P = 0.070, respectively) and rating of perceived exertion (P > 0.05) did not reach significance. Maximal voluntary contraction torque, voluntary activation (twitch interpolation) and peak twitch torque decreased from pre- to post-exercise (-9 ± 1, -4 ± 1 and -6 ± 1 % all trials compounded, respectively; P < 0.05), with no effect of the temperature or altitude. M-wave amplitude and root mean square activity were reduced (P < 0.05) in hot compared to temperate conditions, while normalized maximal EMG activity did not change. Altitude had no effect on any measured parameters. CONCLUSION: Moderate hypoxia in combination with heat stress reduces cycling time to exhaustion without modifying neuromuscular fatigue characteristics. Impaired oxygen delivery or increased cardiovascular strain, increasing relative exercise intensity, may have also contributed to earlier exercise cessation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The phenomenon of over-recovery consists of a participant’s maximal force levels returning to values above initial levels. The present study examined the presence and causes of over-recovery following local muscular fatigue. Fourteen males completed two fatigue protocols consisting of maximal isometric dorsiflexion contractions. Upon completion of the fatigue protocol participants’ force was monitored over a 15 minute recovery period. Dorsiflexion force and surface electromyography (sEMG) from the tibialis anterior and soleus were monitored concurrently. Following the two fatigue conditions (10 and 20% force decrement) force recovered to 100.5 and 99.5% of initial levels for each condition, respectively. Surface EMG root-mean-square amplitude and MPF exhibited changes consistent with a warm-up effect. It was concluded that over-recovery was not present in the tibialis anterior following a local muscular fatigue. However, the return in force to initial values, rather than a persistent decrement as normally observed, was mediated by the warm-up effect.